Data-logger and alarm

Similar documents
EL-USB-1-LCD Temperature Data Logger with LCD

EasyLog Data Logger Series

EasyLog Data Logger Series

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-USB-1-LCD Temperature Data Logger with LCD

Danfoss gas detection units

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

Danfoss gas detection unit Type GD Heavy Duty

Specifications Minimum Typical Maximum Unit

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

Danfoss gas detection units

portable gas analyser

EL-OEM-3 OEM Packaged Voltage Data Logger

HOBO U14 Data Logger User Manual

Introduction. OM-THA2

EL-USB-TC Thermocouple Data Logger with USB Interface

portable gas analyser

STARS SHOULD BE WELL LIT.

ELMTEC. Kattreppeln Königslutter / /

PRODUCT SPECIFICATION

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Platinum Touch/Rotem One Touch

gas monitoring system

LogTag Recorders Ltd TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

IMR IX176 Portable Gas Detector User Manual

EL-OEM-3 OEM Packaged Voltage Data Logger

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

10A Micro-Ohmmeter Model 6250

Dräger Pac 8500 Single-Gas Detector

UTRED day Logger with display

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

GB Art. Nr

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Dräger Pac 6000 Single-Gas Detector

Dräger X-am 7000 Multi-Gas Detection


Speed and Frequency Seite 1 von 7

CLIMATRON GROWTH CABINETS

Automatic Isokinetic Sampler ST5

Constant climate chambers

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

SMS GSM Alarm Messenger

Using the Model 1500 Portable Chilled Mirror Hygrometer

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

Temperature Monitoring System. Specifications

THX-DL Data Logger USER & INSTALLATION MANUAL V

LogTag TICT - is0 Tag

Multifunction IAQ Monitor

Constant climate chambers

Dräger Pac 8000 Single-Gas Detection Device

XWA11V. Walk-In Temp / Door /Alarm / Light Module

Gas Controller Module GC-06

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Constant climate chambers

USER MANUAL USB Multi-Function Datalogger Model RHT35

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Monitoring system. testo 160 Monitoring system for the monitoring of temperature, humidity, light intensity, UV radiation and CO 2. concentration.

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Carbon Monoxide CO Transmitter ADT-X3-1110

onlinecomponents.com

ECOLOG Data Sheets Status May 2015

10A Micro-Ohmmeter Model 6250

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

QuadraTouch Pro Software Manual Dryer Control System

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

GreenCon On/Off Room Thermostat

TOOLS AND INSTRUMENTS

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

WHO PQS-Code E006/020. Fridge-tag 2 Storage temperature monitor with USB port

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

LOAD LIMITER S CONTROL

Refrigerator/Freezer Thermometer

Measuring Recording Online Monitoring Regulation Alarming

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

RADIO CONTROL SYSTEMS

WHO PQS-Code E006/016. Q-tag CLm doc USB Multi- Limit Temperature Indicator

TER Active Room Temperature Sensor (Controller),

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Constant climate chamber with humidity

Operation manual. Rooftop Packaged Unit

Laboratory Refrigerator/Deep Freezer TC 802

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

2014, TempSen Electronics Company

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Monitoring Solutions

Refrigerator/Freezer Thermometer

Stand Alone DYNAGARD SP Operation Manual

Constant climate chambers

Visit us at testo 835 Infrared and contact thermometer

FLOW CONTROLLER TYPE S/601

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Transcription:

Data-logger and alarm

has a user friendly program Actual size: 200x110mm The main feature of the is the color display screen (4.3 ) with WQVGA 480x272 dots resolution with led backlighting. The user interface is easy and friendly. The easy touch screen systems gives both the typical easy to use approach of a touch screen system and the strength and mechanical protection of a polycarbonate IP65 keyboard. The various screenshots and some settings too are displayed according to the in Configuration. settings 2

records the following data: 1= Environment temperature * 2= Environment humidity * 3= Environment CO2 * 4= Environment NH3 * 5= Outdoor temperature * 6= Environment static pressure 7= Auxiliary 1 temperature 8= Auxiliary 2 temperature The above data are recorded daily for the entire duration of cycle (512 days max). Data are sampled with 15 min frequency and stored in the system memory. * with complies with 2007/43/CE Animal Welfare directives. Environmental parameters alarm Besides the data-logger function (temp, %Rh, CO2, NH3, environment static pressure) the alarm set which is triggered anytime the threshold value is reached. Besides the General Alarm (onboard ), when using the HDY6 extension, you also have a contact for each single alarm so a quick action can be taken on the ventilation system to push the controlled parameter back to the required limits according to the animal wellness target. Data transfer Communication with external world is by USB pen drive. By Xlog Dialogue program you can monitor on your PC all the data exported thru the USB keys. 3

Controlled parameters 4

Zoom on Indoor temperature (same structure applies to the other parameters) Temperature details - Current temperature - Average value in the last 48 hours - Min/Max values during current day. Daily temperature archive For all days of cycle: - Average value in the last 48 hours - Min/Max values during current day of cycle. Temperature diagram - Min/Average/Max values referred to the last 60 days of cycle. Temperature hourly archive For every day of cycle: - 96 recordings per day. Temperature diagram - Value of temperature recorded every 15 minutes for every day of cycle. 5

Zoom on alarms 6

Layout components Xlog computer HXNE N.8 Analogs Inputs unit HDY6 N.6 Relays Output unit HA20 Power-pack for probe SX Temperature probe RHR Humidity probe CO2E C02 probe NH3M NHE probe DP59/W Negative pressure controller 7

Component list This is a typical example of the components need to control: The component list will then be: Environment temperature Environment humidity Environment CO2 Outdoor temperature N.1 Xlog (central unit) N.1 HXNE (inputs extension) N.2 SX (1 environmental temperature probe + 1 outdoor temperature probe) N.1 RHR + HA20 (humidity probe + power-pack) N.1 CO2E + HA20 (CO2 probe + power-pack) N.1 USBP (USB IP55 external plug) *1 N.1 HDY6 (Relay outputs extension) *2 Model Price Euro Description Xlog 630,00 Central uni t HXNE 171,00 Inputs extension SX 8,60 Temperature probe RHR 320,00 Humidity probe 0...100% CO2E 560,00 CO2 probe 0...10.000ppm HA20 42,00 Power-pack for probe * 1 USBP 34,00 USB IP65 external plug * 2 HDY6 85,00 Relay outputs extension * 3 DP59/W 290,00 Negative pressure controlle r * 4 NH3M - - - NH3 probe 0.0...100.0pp m *1 comes with a USB plug which is located inside its box. As option we can also deliver (USBP) a professional IP65 waterproof USB plug to be installed on the box itself so USB port can be reached without opening the box. *2 Besides the data-logger function (temp, %Rh, CO2, NH3, ambient negative pressure) the alarm set which is triggered anytime the threshold value is reached. Besides the General Alarm (onboard ), when using the HDY6 extension, you also have a contact for each single alarm so a quick action can be taken on the ventilation system to push the controlled parameter back to the required limits according to the animal wellness target. *3 By the DP59/W depressiometer you can trigger an alarm anytime the system goes below a preset value of depression. This typically happens when ventilation does not work properly. This alarm enables a fast reaction to avoid bird suffocation. *4 NH3 Ammonia. The avalaible sensors are of electrochemical type and their duration and accuracy can vary greatly according to ammonia concentration. This sensor is not supplied by us. 8

Brochure EN 281014