TECHNICAL DATA SHEET WORKING SPECIFICATION. Mains Power Supply: Wall Mounting. Online Connectivity. Operating Voltage. Data Feedback.

Similar documents
CONTROL CENTRE FOR CENTRALISED LUBRICATION SYSTEM WITH PROGRESSIVE FEEDER AND SPRAY NOZZLES CCL Alpha Spray

CONTROL CENTRE FOR CENTRALISED LUBRICATION SYSTEM WITH PROGRESSIVE FEEDER CCL Alpha

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:

Unique Washroom Solutions

10. Water Dispensers

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Test Kits and Test Equipment

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

- website: Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire WR9 0QH, UK

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation

Dispensing slide Removing and installation of Jura C/E/F/-Serie and similar models. For Jura parts and repairs contact

APP Environmental Services P/L.

Installation Instructions EFS Hand Washing Station

SENSELEC INFRA-RED CONTROLS

OPERATION AND INSTALLATION MANUAL

Designed in the UK. Rapide. User Guide V-024E. Performance is everything. vax.co.uk

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

LEAKSTOPPER RANGE Multizone water leak detection systems

AUTOMATIC TAPS. Infrared Taps. The perfect hygiene and water saving enhancement

Owner s Manual FS-10/FreshSpa

EHT10 Electric Hot Water Tap

Geberit Assisted Toilet Pre-Installation Instructions

Symphony Plus Pressurized Water Sanitizing Kit P/N

D3000. Installation & Setup Guide

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

DEMA 830 Laundry Master TM Installation Instructions

Installation & User Guide

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

Installation & User Guide

PINNACLE WAREWASH CONTROL By DEMA DP-812-DL-1T DP-813-DLL-1T DP-812-LL-1T DP-813-LLL-1T Introduction

Camera Housing Washer Units 5 and 25 Litre

RainHarvesting Systems Brochure 2011

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

Rapide Deluxe PT. User Guide V-026PTS. Performance is everything. vax.co.uk

DEKO 190 Ward washer-disinfector

Plumbing Guidelines 2012 IBC/ANSI A

HATCHERY APPLIANCIES. Hatchery appliances. Hatching Trays. Hatching Bottles. Egg Storage Container. Incubation Cabinet. Egg Sorting Machine

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

LEAKSTOPPER 1 Single zone water leak detection system

Weatherproof 14" x 12" x 7" Enclosure with 110 VAC Mounting Plate, Cooling Fan and Heater. Model: NB HF. Applications and Features

The. Range. Clover s colour-coded system for the easy training of cleaning staff C H E M I C A L S.

Hand Dryer Installation & User Manual

Accessible Toilet Alarm

BRITA Vivreau Vi Dispenser

Laundry. a wide range of automatic peristaltic dosing systems. innovation > technology > future

AUTOMATIC BEDPAN AND URINAL WASHERS MODEL LP/IN90-S/D.T.A SELF-PRODUCED STEAM DISINFECTION

AGP. (All Grade Pellet) Troubleshooting Guide Document Copyright 2017 Travis Industries Certified Factory Training Program

Installing the Turbo Floor Model System

Action shower Fog Rain

innovation > technology > future

SPRITE Warewash Dispensing System

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

How to care for your water storage tank

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Sprite III Warewash Dispensing System

Quality Washroom Products

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

VADA - Rain2Main Automatic Rainwater Controller

SERVICE REQUIREMENTS

Stainless Steel Sanitaryware

We ve Got Panels Under Control.

Installation & Operating Instructions

chlorination evolved FEEDERS New Design HIgh Efficiency Made in the U.S.A.

Spare Parts List. Universal Utensil Washer FV V / 460V / 60HZ 3P / MIKE 2

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

GREEN LOO DRY COMPOSTING TOILET MANUAL. for the. GT 120 Family and GT 330

Warewash Systems. innovation > technology > future

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

PWC 7000 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model Copyright 2012 Vertex Water Products

Comfort Odour free Easy handling. Waterless. Environmentally friendly. Feels like home. Comfort wherever you are.

Geberit AquaClean 8000plus. Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio

Vernacare. Vernacare

ABOUT BRIGHTWELL DISPENSERS

The Aquabar 2. Table of Contents

Installation & User Guide

BRITA Vivreau Vi Dispenser

Carpet washer. Vax careline V-135B. Vax model number:

Rhima Deko 190 Washer-disinfector for human waste containers

Nexus FS Filtration Installation Guide. September 19, 2011

WASHROOM & PLUMBING SOLUTIONS

Specification for On-Line UPS Battery Monitoring and Data Management System

MKTF CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual

DR30 MAX Warewash Chemical Dispenser Dispensing technology by Seko UK

Panamatic. Midi & Mini. Installation instructions.

Harrier + Smart Controller & Chemical Management System

4 wire conventional alarm system

Wireless Water Detection Sensors General Description Features of Monnit ALTA Sensors Water Detection Principle of Operation

MIX Boiler & Font Range Service Manual

BX444-Mc Gas Detector

AF2 COMPACT line. Washer disinfector for human waste containers. Your Health, our Technology

CCS-100. Installation Manual

DEMA 844 Laundry Master Laundry Chemical Dispensing

ES SERIES SURGICAL SCRUB SINKS

CONTENTS. Frequently asked questions: Usage Care and maintenance Safety Technical and installation. Settings

SECURIT 700L PLUS ENGINEERING MANUAL

Carpet washer. vax.co.uk. W91-RS-B Series W90-RS-B Series. Vax Careline: (UK) (ROI) Vax model number: Version 1.

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer. Vax Careline: AU: NZ: VCWRS700

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Transcription:

TECHNICAL DATA SHEET WORKING SPECIFICATION Mains Power Supply: Wall Mounting Operating Voltage Online Connectivity Maximum Load Data Feedback 100-240V AC / 50-60Hz 12V DC Snap fit, quick release wall bracket included WiFi, LoRaWAN, GSM 300mA @ 12VDC Average consumption, Predicted replenishment, Live consumable level feedback, Remote access to settings, Peak time analysis, Activation count, Email alerts, Toilet paper monitoring Working Temperature Online Security Protocols 600mA @ 12VDC Working Load 5-55 C Weight 0.7Kg Local access + key combination required to launch portal, SSL encryption, SHA256 hash encryption Warranty Contract Dependant (2 year - unlimited) Sensor Float Switch or Flow Switch enabled for cisterns and solenoid operated urinals 35mm 120mm Approvals CE Dose Size 0.5-10ml per activation Pump to cistern - 3m Max, Pump to reservoir - 8m Max 140mm Installation Distances

INSTALLATION REQUIREMENTS & IMPORTANT INFORMATION Blue Reservoir Position Please see the below diagram that shows appropriate mounting positions. Set up of Blue Dispenser The Blue Dispenser is delivered ready to use, if you wish to change any of the settings you can do so via the UI on the dispenser. Recommended Blue To be used with Rapid Washrooms Blue only. Warranty void if other Blue is used. Power Recommended to be hard-wired to spur by qualified professional. Blue Dispenser should be mounted no further than 500mm away from the cistern. Dosing Nozzle should be mounted so that it is above the water level of the cistern when full. Float Switch should be mounted so that there is enough space for the float switch to open fully and close with no obstructions. The water level should rise above it when the cistern is full and drop completely below the switch when empty. Reservoirs should be placed no more than 5m away from the Blue Dispenser. Total length of Power Lead is 3.5m. Power point must be reachable.

CISTERN REQUIREMENTS & IMPORTANT INFORMATION Cistern wall thickness must be between 1mm - 5mm 16mm hole required for mounting the Blue Dosing Nozzle. 22mm hole required for mounting the Float Switch.

INSTALLATION SCENARIOS Cistern positioned in a void behind the toilet with a 5L reservoir. This installation is suitable for cisterns that are mounted in a cavity that is separate to the toilet, where there is no public access. A 5L bottle reservoir can be used to feed a maximum of one system. If you require a reservoir to feed more than one system please see the installation for a 32L centralised reservoir. Toilet Cistern Wall 5L Reservoir

INSTALLATION SCENARIOS Cistern positioned in a void behind the toilet with a 32L reservoir. This installation is suitable for cisterns that are mounted in a cavity that is separated from the toilet, where there is no public access. A 32L reservoir can be used to feed one system. The reservoir tank has a screw in lid with a latch and padlock to prevent tampering. If you require a reservoir to feed more than one system please see the installation for a 32L centralised reservoir on the next page. Toilet Cistern Wall 32L Reservoir

INSTALLATION SCENARIOS Multiple cisterns positioned in a void behind the toilet with a 32L reservoir. This installation is suitable for multiple cisterns that are mounted in the same cavity separate to the toilets, where there is no public access. The distance between furthest blue dispenser to the reservoir must not exceed 5m. A 32L centralised reservoir can be used to feed a minimum of one system and maximum of 5 systems. The reservoir tank has a screw in lid with a latch and padlock to prevent tampering. The distance between furthest blue dispenser to the reservoir must not exceed 5m. Toilet Cistern 32L Reservoir

URINAL INSTALLATION REQUIREMENTS & IMPORTANT INFORMATION Single urinals connected to either a 32L or 5L reservoir. A 32L or 5L reservoir can be used with urinal installation. The Blue Dosing Assembly (see below) is supplied with push-fit connectors that fit 12mm diameter tube. A 32L reservoir can be used to feed one system as shown below. The reservoir tank has a screw in lid with a latch and padlock to prevent tampering. If you require a reservoir to feed more than one system please see the installation for a 32L centralised reservoir on the next page. Blue Dosing Assembly Urinal sensor (not supplied) Urinal (not supplied). Blue Dispenser should be mounted no further than 500mm away from the cistern. Reservoirs should be placed no more than 5m away from the Blue Dispenser. 12mm tube (not supplied). Flush controlling solenoid (not supplied) Water inlet plumbing (not supplied). 32L Reservoir / 5L Bottle Reservoir can be used to feed a single urinal. Total length of Power Lead is 3.5m. Power point must be reachable.

TECHNICAL DATA SHEET URINAL INSTALLATION REQUIREMENTS & IMPORTANT INFORMATION Multiple urinals connected to either a 32L reservoir. A maximum of 5 urinals can be fitted to a 32L reservoir. The Blue Dosing Assembly (see below) is supplied with push-fit connectors that fit 12mm diameter tube. The Blue Dispenser situated furthest from the reservoir must not exceed a distance of 5 metres from the reservoir. It is maximum product life it is best to position the reservoir centrally between all urinals. The distance between furthest blue dispenser to the reservoir must not exceed 5m. Urinal 32L Reservoir Water Inlet