P/N _F NSF Certified June 2010

Similar documents
FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

FG-L Technical Data Sheet

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

PWEE Technical Data Sheet

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

RLNIE with INNOVATOR II

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

RL with INNOVATOR II No Heat Doors

RM with INNOVATOR Doors

RMN with INNOVATOR Doors Technical Data Sheet

RLT with INNOVATOR Doors

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

Engineering Plan Views

Nosing Heater. Return Grill Heater

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

LifeLine Premier RLNIE

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

LWU Technical Data Sheet

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

RL with INNOVATOR Doors

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

NFW, NCW, NFWG, NCWG, NFWE, NCWE

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

Installation & Service Manual

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

Installation & Service Manual

Installation & Service Manual

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

Medium Temperature Bulk Produce and Bakery Merchandisers

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

BCH Medium Temperature Merchandisers

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

MD Medium Temperature Self Contained Open Vertical Merchandisers

Reach-in Merchandisers

MD Medium Temperature Self Contained Open Vertical Merchandisers

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

F-6 Multi-deck Frozen Food Wall Merchandisers

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

Installation & Service Manual

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

RFLNS, RFMNS & RFLTM Freedom Line

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

Service Merchandisers

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

Service Merchandisers

RFLN & RFMN Freedom Line

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

SERIES NAV S Display Merchandisers

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

Glass Doors, Hinged Bottom Mounts

Self-Contained MERCHANDISERS. February

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

Ultra Low Front Rear Load Medium Temperature

Low Temperature. Installation & Operation Manual. Keep in store for future reference. Single Deck Wall & Island Merchandisers P/N F

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

EcoVision Door Manual

Self-Contained MERCHANDISERS. October

SM / SN Medium and Low Temperature Spot Merchandisers

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

Installation & Service Manual

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

LTH Low Temperature Merchandisers

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

Transcription:

G C A F E FN Technical Data Sheet P/N 0465898_F NSF Certified June 2010 B D We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item Part # Description Wiring Item # FAN ASSEMBLIES, AND THERMOSTATS A. 4W Standard Fan Assembly (1) 0392457 Fan Motor, Evaporator (MO.4410101) 0464847 Fan Blade (FB.4780649) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator (MO.4410544) 0464847 Fan Blade (FB.4780649) B. Optional Adjustable Refrigeration Thermostat (2) C. 0398557 Defrost Termination Thermostat (3) (Electric Defrost only) (CT.4440611) D. 0481370 Heater Switch (4) (Koolgas Defrost only) (CT.4440738) Item Part # Description Wiring Item # HEATERS E. 208V Evaporator Defrost Heaters (5) 0481864 4 ft case (HE.4850637) 0444057 6 ft case (HE.4850620) 0462159 8 ft case (HE.4850603) 0444058 12 ft case (HE.4850571) F. 208V Drip Pan Defrost Heaters, Electric (6) 0481865 4 ft case (HE.4850638) 0444300 6 ft case (HE.4850609) 0462160 8 ft case (HE.4850636) 0444296 12 ft case (HE.4850572) 120V Drip Pan Defrost Heaters, Koolgas (7) 0488967 4 ft case (HE.4850641) 0465906 6 ft case (HE.4850628) 0465907 8 ft case (HE.4850622) 0465908 12 ft case (HE.4850623) G. Nosing Anti-sweat Heaters (8) 0495009 4 ft case (HE.4880687) 0495006 6 ft case (HE.4850684) 0495007 8 ft case (HE.4850685) 0495008 12 ft case (HE.4850686) Note: Revision F adds 4 ft model 2009 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM P/N0465898F

Engineering Plan Views Low / Medium Temperature 07-2009 PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 Dimensions shown as inches & (mm). FN / FNG 25 3 /8 (645) Electrical Field Connection 41 1 /2 (1054) Electrical Stub Up Area 6 x 6 (152 x 152) Waste Outlet Wireway 26 1 /2 (673) NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD. A B D 43 7 /8 (1114) 4 1 /4 (108) 4 3 /4 (120) Splashguard C FRONT 41 1 /2 (1054) Splashguard Refrigeration Outlet Waste Outlet 11 3 /4 (299) 4 1 /2 (115) 8 (203) 27 5 /8 (701) 12 1 /8 (307) 33 (839) 31 5 /8 (802) 34 3 /4 (884) 43 3 /8 (1101) 4 ft 6 ft 8 ft 12 ft General (A) Case Length (without ends or partitions) 48 1 /4 (1226) 73 3 /4 (1873) 96 3 /8 (2448) 144 1 /2 (3670) (Each end and insulated partition adds 2 in. (51 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 43 3 /8 (1101) 43 3 /8 (1101) 43 3 /8 (1101) 43 3 /8 (1101) Back of case to front of splashguard 34 3 /4 (884) 34 3 /4 (884) 34 3 /4 (884) 34 3 /4 (884) Back of case to O/S edge of front leg 31 5 /8 (802) 31 5 /8 (802) 31 5 /8 (802) 31 5 /8 (802) Distance between edges of external legs and center legs NA 30 1 /4 (768) 41 1 /2 (1054) 41 1 /2 (1054) Distance between edges of center legs NA NA NA 43 7 /8 (1114) Distance between front legs and splashguard 3 1 /8 (82) 3 1 /8 (82) 3 1 /8 (82) 3 1 /8 (82) Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of stub up area 36 1 /8 (9018) 61 5 /8 (1565) 84 1 /4 (2141) 132 3 /8 (3363) Back of case to center of stub up area 25 3 /8 (645) 25 3 /8 (645) 25 3 /8 (645) 25 3 /8 (645) Length of electrical wireway Wireway 26 1 /2 (673) 26 1 /2 (673) 26 1 /2 (673) 26 1 /2 (673) (C) RH End of case to LH end of wireway 40 1 /2 (1029) 67 1 /2 (1715) 90 1 /8 (2289) 138 1 /4 (3511) Waste Outlets (One each end) (D) RH End of case to the center of LH waste outlet 36 1 /8 (918) 61 5 /8 (1565) 84 1 /4 (2141) 132 3 /8 (3363) RH End of case to the center of RH waste outlet 12 1 /8 (307) 12 1 /8 (307) 12 1 /8 (307) 12 1 /8 (307) Back O/S of case to center of waste outlets 33 (839) 33 (839) 33 (839) 33 (839) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) Refrigeration Outlet Back of case to center of refrigeration outlet 27 5 /8 (701) 27 5 /8 (701) 27 5 /8 (701) 27 5 /8 (701) RH end of case to center of refrigeration outlet 8 (203) 15 (381) 8 (203) 8 (203) 2 of 7 FN Technical Data Sheet HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Narrow Island Display with Solid Walls FN 35 7 /8 (910) Dimensions shown as inches & (mm). Impact Excel FN Low / Medium Temperature REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 F and 55% R.H. MED FF IC Discharge Air ( F) +24 12 22 Evaporator( F) +19 20 30 Unit Sizing ( F) +17 23 33 Btu/hr/ft MED FF IC Parallel 280 390 400 Conventional 290 405 415 Optional energy efficient motors reduce the refrigeration load by 9 Btu/hr/ft. 26 3 /8 (669) Case-to-Case Connection Refrigeration Outlet 3 1 /8 (79) 15 1 /4 (388) FAN 33 3 /8 (848) COIL 27 5 /8 (701) 19 7 /8 (503) 31 5 /8 (802) 33 (839) 34 3 /4 (884) 5 1 /2 (140) DEFROST DATA MED FF IC Frequency (hr) 24 24 24 Defrost Water (lb/ft/day) 0.8 0.75 0.6 (± 15% based on case configuration and product loading). ELECTRIC MED FF IC Temp Term ( F) 48 48 48 Failsafe (minutes) 60 60 60 GAS Duration (minutes) NA 15 18 OFFTIME Not Recommended Standard Defrost Thermostat Close on rise: close 48 F open 33 F 43 3 /8 (1101) CONVENTIONAL CONTROLS Low Pressure Backup Control CI/CO * MED +12 F / +2 F FF 17 F / 29 F IC 27 F / 39 F NSF Certification This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. Indoor Unit Only, Pressure Defrost Termination* Not Recommended *Use a Temperature Pressure Chart to determine PSIG conversions. Estimated Charge ** FN 4 ft 1.0 lb 16 oz 0.5 kg 6 ft 1.5 lb 24 oz 0.7 kg 8 ft 2.0 lb 32 oz 0.9 kg 12 ft 3.0 lb 48 oz 1.4 kg **This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. P/N 0465898_F HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 7

Impact Excel FN Low / Medium Temperature Electrical Data 4 ft 6 ft 8 ft 12 ft Number of Fans 4W Evaporator 1 1 2 2 Amperes Watts 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft Evaporator Fans 120V 60Hz Standard 0.31 0.31 0.62 0.62 24 24 48 48 120V 50Hz Standard 0.38 0.38 0.76 0.76 27 27 54 54 230V 60Hz Export 0.15 0.15 0.30 0.30 24 24 48 48 230V 50Hz Export 0.18 0.18 0.36 0.36 27 27 54 54 120V 60Hz Energy Efficient 0.12 0.12 0.24 0.24 8 8 16 16 230V 60Hz Energy Efficient 0.06 0.06 0.12 0.12 8 8 16 16 Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Standard 0.33 0.50 0.67 1.00 40 60 80 120 230V 50/60Hz Export 0.18 0.26 0.35 0.52 40 60 80 120 Minimum Circuit Ampacity 120V 60Hz Standard 0.84 1.01 1.49 1.82 120V 50Hz Standard 0.76 1.08 1.63 1.96 230V 60Hz Export 0.68 0.61 0.85 1.02 230V 50Hz Export 0.56 0.64 0.91 1.08 120V 60Hz Energy Efficient 0.65 0.82 1.11 1.44 230V 60Hz Energy Efficient 0.44 0.52 0.67 0.84 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 208V Electric Defrost 4.4 6.54 7.69 11.54 910 1360 1600 2400 230V Export Electric Defrost 3.8 5.91 6.96 10.43 800 1360 1600 2400 120V Koolgas Defrost 0.92 1.33 1.67 3.33 110 160 200 400 Standard Lighting None 4 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. FN Technical Data Sheet

Impact Excel FN Low / Medium Temperature Product Data Recommended Usable Cube 1 (Cu Ft/Ft) 3.54 ft 3 /ft (0.33 m 3 /m) ARI Total Display Area 2 (Sq Ft/Ft) 2.61 ft 2 /ft (0.80 m 2 /m) Shelf Area 3 (Sq Ft/Ft) 2.78 ft 2 /ft (0.85 m 2 /m) 1 ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using ARI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is NONE. ESTIMATED SHIPPING WEIGHT 5 Case Solid End 4 ft 6 ft 8 ft 12 ft (each) lb (kg) 600 (272) 800 (363) 1000 (454) 1200 (544) 50 (23) 5 Actual weights will vary according to optional kits included. P/N 0465898_F HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 7

Electric Defrost Standard 4 Ft 1 Fan 6 Ft 1 Fan 8 Ft 2 Fans 12 Ft 2 Fans 120V POWER BROWN BAND 1 120V NEUTRAL BROWN BAND 8 Fans Nosing Anti-sweat Heater Refrigeration Thermostat (Optional) 2 Light Blue To } Condensing Unit Defrost Termination Thermostat 3 Dark Blue } To Condensing Unit L1 208 V Power From Defrost Contactors L2 Red 6 Drip Pan Heater 5 Red Electric Defrost Heaters WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Numbers = Parts List Item Numbers. 6 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. FN Technical Data Sheet

Gas Defrost Optional 120V Drip Pan Heater Koolgas Only Yellow Yellow Dark Blue 7 4 Heater Switch Dark Blue 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Numbers = Parts List Item Numbers. P/N 0465898_F HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 7