In 2011 JCAHO in standard E.C.6.20; states that all medical equipment is maintained, tested and inspected (2).

Similar documents
SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

The Principles, The Process, and The Results:

ProFormanceTM Cleaning Verification Products

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

Washer Test Kits User Guide

STERITITE INSTRUCTIONS FOR USE

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

PINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS

Environmental Cleaning Tool Kit

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

DRAFT. Module 4. Decontamination & Environmental Cleaning

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

FLASH PAK STERILIZATION CONTAINER SYSTEM

Discharge and Transfer Cleaning - Isolation

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

Applicable To Employees of the Gundersen St. Joseph s Hospital laboratories and Gundersen Tri-County Hospital laboratories.

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

Discharge and Transfer Cleaning

Lower Your Costs. Expand Your Flexibility.

Cleaning & Sterilization

Mini Guide to hygienic laundry practices. based on the RABC system/en 14065

Dietary Department, Infection Control

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

An overview of sterilizer equipment standards current and planned. Richard Bancroft Science & Technical Director STERIS

Cleaning Verification

SOP SF SOP for LN2 Freezers

Purpose. Team Roles and Responsibilities. System Requirements. Instrument Processing Training

This policy has been adopted by UNC Health Care for its use in infection control. It is provided to you as information only. Infection Control Manual

STANDARD OPERATING PROCEDURE

AMSCO Washer/ Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare.

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

Property Health and Safety Compliance at Housing and Education Centres

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

PICNet CONFERENCE 2013

UV Irreversible Indicators Product Code: UVI-001

SCIF SOP for BSL 2 samples on Aria3

When you sterilize an instrument set, you know what the standards are.

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

Technical Data Monograph. AMSCO 3052 Single-Chamber Washer/Disinfector AMSCO 5052 Single-Chamber Washer/Disinfector

Lower Your Costs. Expand Your Flexibility.

Central Sterile Services Department will receive, decontaminate, process, store and/or dispense sterile and non-sterile to departments requesting.

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Corporate. Laundry SOP. Document Control Summary

Hygea Hygea Hygea

Solution: Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects? OR PACKAGE

GETINGE 9100-series CART & UTENSIL WASHER-DISINFECTOR. Always with you

AMSCO Washer-Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare

Washer disinfectors. MLC Series. for transfer trolleys, sterile containers and bulky items

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

Cascade Contour Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Laser Safety, Utilization and Credentialing Policy

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Instructions for use. Tango & Tango XL , Shower-toilet chair

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental

RELIANCE VISION SINGLE-CHAMBER WASHER/DISINFECTOR

H M H M H M H M H M H M H M B A R R I E R W A S H E R E X T R A C T O R S

A Clean Kitchen is a Food Safe Kitchen

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Support for staff involved in the use of steam cleaning machines. C21/HCQAI Criterion 2 Outcome 8 & 10

Rescues individuals in danger from fire, vehicle accidents, industrial accidents and other situation requiring extraction.

Aesculap Implant Systems

Using Flat Mopping Systems in Hospitals

36.0 Sterile Supply Unit (SSU)

Contents. Ultrawave baths are manufactured in the UK and conform to exacting international standards.

Getinge WD14 Tablo Tabletop washer-disinfector. Fast and with high-throughput

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures. Policy Name: Staff Dining Health and Safety Regulations/Inspections

GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR. Always with you

Operator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M

National Maternity Hospital. Founded in 1894

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Institute of Decontamination Sciences Blackburn House, Redhouse Road, Seafield, Bathgate, West Lothian EH47 7AQ

Lifeline. Lifeline. Save lives together!

Getinge WD14 Tablo Tabletop washer-disinfector

AGC Sputter Coating Glass Processing Guidelines

NUMBER: R&C-ARF-4.0 ISSUED: REV. A: REV. B: REV. C: REV. D: REV. E: 2.1. Frequency of Contact and Non-Contact Bedding Changes:

CELITRON COMPACT SOLUTION FOR BIOHAZARD WASTE DISPOSAL Integrated Sterilizer and Shredder (ISS)

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

THE BASICS OF DECONTAMINATION

HEALTHCARE SAFETY INSPECTION

Special Precautions Isolation Plan Environmental Services

Instructions for Use Spinal Punches IFU

CER-1 & CER-2 Installation & Testing Instructions

highest performance on smallest footprint WD 200: Single-chamber washer-disinfector in compliance with EN ISO 15883

CLEANING INSTRUCTIONS

Burn Injury Investigation Report Preparing a Live Fire Prop for Use Miami-Dade County Fire Rescue Department, November 18, 2011

PRO JET RANGE FOR A PRODUCTIVE, CLEAN & HEALTHY WORK ENVIRONMENT

Technical Data Monograph. The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012

GUIDELINES FOR TEMPORARY FOOD SERVICE PREMISES

Tru-D Rapid Room Disinfection

GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

OHIO UNIVERSITY RADIATION SAFETY REVIEW

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Large Steam Sterilizers. CELITRON COMPACT SOLUTION FOR BIOHAZARD WASTE DISPOSAL Integrated Sterilizer and Shredder (ISS)

Transcription:

SUBJECT: Routine monitoring of the Medical Cart Washer DEPARTMENT: Central Service APPROVED BY: EFFECTIVE: REVISED: 2/2012 PURPOSE: To ensure a properly functioning medical cart washer POLICY: Routine monitoring of Medical Cart Washer RATIONALE: "A problem analysis should be completed for any problem with any aspect of decontamination that can pose a risk to personnel or patients. The problem analysis should define and resolve the problem and the system should be monitored to ensure that the problem has been corrected"(1). ST 79; 2009A section 7.5.3.3 states this on weekly testing Mechanical cleaning equipment should be tested upon installation, weekly (preferably daily) during routine use, and after major repairs. A major repair is a repair that is outside the scope of routine preventive maintenance and that significantly affects the performance of the equipment. Examples include replacement of the water pump(s), detergent delivery system, heating system, water delivery system, water treatment system, or computer control or an upgrade to software (1) In 2011 JCAHO in standard E.C.6.20; states that all medical equipment is maintained, tested and inspected (2). The medical cart washer is considered a piece of medical equipment and medical cart washers need to be properly functioning to provide the best patient care as possible and help in reducing hospital acquired infections (4,5). Cart washers are important tools in the overall efforts to reduce cross contamination. Often they are used to clean not just surgical case carts, but also basins, IV poles, instrument containers, wheel chairs and other supply and patient transport equipment (3). The CartWashCheck is the first test designed to challenge the mechanical efficiency of the medical cart washer. Because there are various models of cart washers, cycle selection can be limited. Each department needs to understand the various cycles they have to use and select the proper cycle for the item that is going to be processed. Because of the vast number of cart washers and 1

cycle selections temperature ranges can be different. That is why it is important that all staff are trained on a regular basis on how the equipment (cart washer is used) and understand that temperatures could be different for the various cycles selected. The pass and fail concerning temperature is different for the various cycles. The range of temperatures is usually between 120-180 F depending on the cycle selected. So passing and failing a temperature is dependent on the cycle selected and staff need to know the correct temperature for each cycle selected.. These convenient test strips can be quickly and easily adhered to any metal surface with the peel off adhesive that leaves no residue. Place these test on surfaces which are furthest from the medical cart washer jets or in area where you suspect coverage is most difficult. The special hydrochromic ink will change color only if moistened by water (black to white). This demonstrates that water is reaching the area tested and indicates proper mechanical action by the medical cart washer. Further, to ensure that your washer is achieving your target temperature setting, the CartWashCheck also includes an irreversible thermometer. The thermochromatic (heat sensitive) indicator above the hydrophilic ink will register temperature levels of 120oF, 150oF, and 180oF, documenting the temperature reached during the cycle. The use of the CartWashCheck is an excellent tool to use for training of new employees as well as establishing a Quality Improvement Program. It can be used for checking whether the medical cart washer is working properly and the staff is loading items to be cleaned into the washer correctly. The frequency of testing/ monitoring needs to be determined by each department. PROCEDURE: 1. The CartWashCheck is a test designed to challenge the mechanical efficiency of the medical cart washer. These convenient test strips can be quickly and easily adhered to any metal surface with the peel off adhesive that leaves no residue. 2. Note an inactive strip is black/dark blue in color before being exposed to any mechanical cart washing process. 3. The frequency of testing of at least weekly and after any maintenance on the equipment is the suggested time frame. 4. Peal the back of the CartWashCheck strip and remove the protective layer to expose the adhesive (sticky side) of the CartWashCheck strip. 5. Place at least one CartWashCheck test strip on the surface being tested which is the furthest from the medical cart washer jets or in areas where you suspect coverage is most difficult (you can place more than one CartWashCheck strip in other locations if desired). See Figure 1 6. Follow manufactures instructions for proper loading of the item tested (cleaned) into the medical cart washer. Follow those instructions. 7. Operate (select) the proper cycle for the item being (cleaned) tests (example cart program). Follow manufactures instructions. 8. After the cycle follow manufactures instructions for proper unloading of the item cleaned in the medical cart washer (surface may be hot; be careful). Read the CartWashCheck 2

test strip and document all results. You are looking for color change from black/dark blue to white and then read the temperature on the irreversible temperature gauge.the thermochromatic (heat sensitive) indicator above the hydrophilic ink will register temperature levels of 120oF, 150oF, and 180oF, documenting the temperature reached during the cycle. 9. Remember that an inactive CartWashCheck strip is black/dark blue in color before being exposed to any medical cart washing process and no temperature recorded. 10. The special hydrochromic ink will change color only if moistened by water (from black/dark blue to white). This demonstrates that water is reaching the area tested and can indicate proper mechanical action by the water. 11. The CartWashCheck reports the temperature level reached during the cycle 12. A properly exposed CartWashCheck will turn white and record a temperature of at least 120 F (black bar line). 13. A white only color test strip shows only exposure to water in that area tested and no exposure to temperatures above 120ºF. 14. After reading and documenting the results you can peel off the CartWashCheck test strip and dispose of in your trash.there is no hazardous material on the CartWashCheck test strip. 15. If proper temperature or proper water exposure are not achieved please bring results to the attention of the proper person in the department for action. Maintenance on Equipment: Staff should perform all maintenance outline in the manufacture manual such as cleaning screens, checking water jets on the schedule provided by the manufacture to help ensure a properly performing medical cart washer Staff should record all observations such as: condition of the inside of the chamber(biofilm build up, other observations..) After any maintenance on the equipment, perform a test using CartWashCheck to ensure that the equipment is at the minimum temperature (120ºF) and water is reaching difficult hard to reach areas of the medical cart washer. Follow the weekly test process. Have the maintenance person wait until the test results are complete before leaving. RESPONSIBILITY: Central Service personnel are responsible for the proper use, result interpretation, and documentation of the CartWashCheck test strip on the medical cart washer NOTE : Transportation and Storage Conditions: Keep Below 100oF & Avoid Exposure to Moisture. 3

The CartWashCheckTM is the first test designed to challenge the mechanical efficiency of the cart washer. These convenient tests can be quickly and easily adhered to any metal surface with the peel off adhesive that leaves no residue. Unexposed CartWashCheck Figure 1 Place these tests on surfaces which are furthest from the washer jets or in areas where you suspect coverage are most difficult. The special hydrophilic ink will change color (from black to white) only if moistened by water. This demonstrates that water is reaching the area tested and indicates proper mechanical action by the washer. White Means Water Reached the Test To ensure that your washer is achieving your target temperature setting, the CartWashCheck also includes an irreversible thermometer. The thermochromatic (heat sensitive) indicator above the hydrophilic ink will register temperature levels of 120oF, 150oF, and 180oF, documenting the temperature reached during the cycle. The Temperature Gauge Means the Surface Reached at Least the Corresponding Temp. 4

CartWashCheck Test Log Make/ Model of the Medical Cart Washer # Date Tested Testers Initials Item Tested 1/1/11 SMK Cart Cycle 1/3/11 SMK Cart Cycle Cycle Selection Case Cart Case Cart Temperature Result Water Exposure Result Action Taken 120 F White Fail, did not reach correct Temp. 180 F White Pass Other Call Repair Company to test temperature Obsrevations: *Record all results: correct result should be white background and a minimum of 120ºF; on CartWashCheck. Please note that 120 F might not be the temperature required at each facility consult your managemtn and manufacture of the equipment for correct temperature for the cycle selected 5

Footnotes 1. ANSI/AAMI ST 79 2009A 2. http://www.jointcommission.org 3. 3/ 2009 ; Managing Infection Control; Kovach, Understanding Your Cart Washer 4. Publication ID # M2044.000808.RevA @2000 by STERIS Corporation 5. http://midbrookmedical.com/washers.html 6