Sunrise the beginning of a brand new day

Similar documents
UMWELTSIMULATION TEMPERATUR VARIO. Walk-in chambers in modular design for multifunctional applications in different industrial fields

TEMPERATURE SHOCK TEST CHAMBERS

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 STABILITY

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

Reproducible Climate...

FITOCLIMA 600 & 1200 PHARMA

Vibration. test chambers. acstestchambers.com. powered by

FitoClima 600 PDH. Climatic Chamber specially developed for reaching low humidity levels DC013EN/03

Thermal Shock Chambers. acstestchambers.com

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

Constant climate chambers

Constant climate chamber with humidity

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Constant climate chambers

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

Internet. Climate rating definitions. Customer service.

Constant climate chambers

Multi-Lab REFRIGERATORS Frigidere medicale

LAUDA Additional devices Immersion coolers, through-flow coolers, circulation heat exchangers

Environmental Chambers

Constant climate chamber with ICH-compliant illumination

A660 Air Conditioning Laboratory Unit

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

EC 160 CO 2. Incubator

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

MADE IN ITALY SERVICE INNOVATION QUALITY RELIABILITY

Bench Top Cooling Tower H893

Dry Corrosion. Test Cabinets. acstestchambers.com

Dry Corrosion. Test Cabinets. acstestchambers.com

FITOCLIMA 600 & 1200 BIO

Constant climate chambers

Constant climate chambers

Environmental Chambers

Laboratory refrigerators

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Drying ovens, incubators, cooled incubators

Technical Description. Climate Test Cabinet with increased change rates. Stress Screening System Weiss. Mat. No.: Type

Remote Conditioners. RC-Series. ZPRC Series

WR-KWAP (Platelet incubator/agitator) HPL

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

Refrigerated Incubators / Environmental Testing Chambers

Benefit Cabinets. Performance. Efficiency

Benefit Cabinets. Performance. Efficiency

Steam sterilizer AHS-75-DRY

DOUBLE DOOR FREEZER.

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

ComfortSense 7500 Thermostat. User Guide

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

ULTRA.GUARD ultra low temperature freezer

laboratory & sterilization technology

Chromatographic Air circulated Refrigerator, two-door TC 603

Compact design for personal use Ready to network with your computer.

Huminator II. Precision Humidity Generator. ww.testo.in

HALT & HASS Systems.

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

FitoClima / FitoTerm SOL chambers

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

KMF Environmental test chamber for constant climate

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Floor model Freeze Dryer

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Compact Ultra Low Temperature Chamber

laboratory & sterilization technology

Medical Refrigerators

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

CLIMATRON GROWTH CABINETS

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Plant growth chambers

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Remote Conditioners. RC-Series. ZPRC Series

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

Freeze-Drying Solutions

NC SERIES. Bench Top Steam Sterilizers

Your Health, our Technology AWD655. Instrument Washer Disinfector

Environmental simulation chamber for complex alternating climate profiles

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

LAUDA ECO. Precise, economical, flexible

Power Flame Incorporated

Air & Water Heat Pump R832

REFRIGERATOR M E D I C A L.

ThermoControl 0 C - 10 C - 20 C - 30 C

Photo Stability Chamber

STERIDENT, STERIMAT, STERIMAT PLUS

ComfortSense 7500 Commercial Thermostat. User Guide

PR / MP I Laboratory / Medicine

Stability Testing according to GMP & FDA

DEKO 25 washer-disinfector

Transcription:

Sunrise the beginning of a brand new day Choosing a new chamber should be easy you already know what you want. Angelantoni Industrie is now offering the most complete standard line of chambers available through a single manufacturer. What is new for us are the features and innovations. What is new for you is being able to find exactly what you want, quickly and easily. New and Improved Features - Completely new door system for ease of access and confident closing - New steam generator system for humidity systems - New touchscreen control panel - Our highest reliability ever Models and Styles BASIC series: (both climatic and T only), -40 C with single stage compressor or -70 C with cascade refrigeration, standard temperature change rate BENCH-TOP version: 16 or 60 liters (T only) and 160 liters (both climatic and T only) E series: Energy saving version (climatic), for lower testing performances: T range -20/+180 C, change rates of less than 2 C per minute ES series: Environmental screening version (both climatic and T only) with higher testing performances: -40 C with single stage compressor or -70 C with cascade refrigeration, temperature change rates of up to 5 C per minute ESS series: Speedy version (both climatic and T only): -70 C with cascade refrigeration, temperature change rates of up to 15 C per minute DEWPPY series: (climatic) with a different RH control, based on a bath thermoregulated at dew point for more precise humidity regulation V series: (climatic) biomedical version: two models (700-1500 l) for tests at steady state conditions with very no need for fast T change rates Size in liters Basic 16 60 160 250 300 340 500 600 700 1000 1200 1400 1500 1600 2000* Benchtop E ES ESS Dewppy V * 2000 l chambers are available also with 2000 mm dim. in height or width = Climatic models for Temperature and Relative humidity tests = Thermostatic models for only Temperature tests page 2

Sunrise at a glance! 1. Heated inspection window: a fully transparent double heating film allows the test compartment to be easily and clearly inspected and prevents condensation from forming on the glass. 2 Double ceiling: prevents any condensation drop from falling onto the specimen. 3 Axial fan: it allows a better distribution of air and helps specimens adapt to temperature variations. 4 Wheels: they allow the chamber to be easily moved 5 Rounded corners: they allow a better drainage of condensation drops and easier cleaning. 6 Water tank: for the humidification system, it is accessible by simply opening the lower door of the chamber. 7 Double floor: it improves the distribution of air inside the chamber. 8 Locking system: new mechanical closings Control system: consists of a PLC and "KeyKratos Plus Limited" user interface placed on the door. In 6 languages (Italian, English, French, German, Spanish, Dutch), it allows a perfect interaction between the equipment and the user. Dehumidifier: operates down to 20 C dew point. Interfaces: RS232 or RS485 (on request) Options: No. 4 analogic inputs + no. 4 inputs for PT100 probes + no. 8 auxiliary contacts Digital min./max. thermostat: in case of malfunctioning, the chamber stops running Humidity: open/close circuit for humidification water complete with mechanical filter. Humidification system: - new humidifier with a self contained heater and dedicated controlling S/W for a better reliability. - the water tank can be fed through normal running water thanks to the embedded softener (except for 160 l models) or through manual filling - water recycling can be activated by a button on the control panel page 3

Sunrise overview Control and management system: controlled by PLC and "KeyKratos Plus Limited" user interface placed on the door. Easy use by touch screen with related pop up screen where necessary. User friendly data input during editing, check and administration of cycle. Memory capacity to 1000 cycles with 350 segments (on compact flash). Messages on scheduled maintenance activities. Chamber lining: stainless steel with vapour-proof welding (all models). Drip cap: invisibly placed under the door, it is extremely efficient. Portholes: 80 mm dia. available on all models, 150 mm dia. not available for 16 l model Noise reduction system: installed in the machine compartment, it reduces the chamber noise. Further noise reduction may be provided upon request (with water condensation). Double ceiling and double floor: they allow a better air distribution inside the chamber avoiding condensation or dripping over the specimen. Air treatment system: it ensures a precise control of the climatic parameters inside the chamber with minimal thermal inertia; an axial fan allows rapid temperature variations of both air and specimen. Basic Configuration Inspection window: multiple-crystal, with double heated transparent film, 450x450 mm size (smaller sizes for bench-top models) Self feeding system (town water through chamber embedded softener) not available for 160 l models Wheels: self-pivoting wheels. Serial interface: RS232 (or RS485 on request). RS422 for star or multidrop connection to the remote control system (distances up to 15 and 1000 metres respectively). Port hole: 80 mm diameter, fitted with rubber cap. It allows internal-external electrical, mechanical or hydraulic connections. Thermostat: max./min. digital thermostat with independent probe UPS connection: (the UPS is an optional accessory) it is used for the supply of the microprocessor unit in order to guarantee data storage and acquisition even in case of power failure. No. 1 internal grid shelf Air condenser T & RH analogic retransmission no. 1 auxiliary contact Refrigeration system: simple and reliable, it ensures optimum thermodynamic performances at any temperature. Network connection: several chambers may be connected to a master PC for both local and remote centralised supervision, storage of test cycles and data logging. Structure: the equipment modularity allows easy servicing and upgrades. Ergonomics: it allows easy access to the chamber wherever placed; the control interface is mounted on the front panel; the water tank is easily filled from the lower front panel. Humidification system (climatic version): The new humidifier with a self contained heater and dedicated controlling S/W offers two great advantages: correct functioning without the need of distilled or demineralised water; the use of dry vapour in order to avoid condensation on the specimens and to reproduce real environmental conditions. Humidity control (climatic version): the principle of the Assman psychometer (dry bulb - wet bulb) was applied to allow the microprocessor to correctly determine relative humidity and setting parameters. Options WinKratos software: installed on local or remote PC (to be supplied upon request) and running under Windows 2000, XP (license included) Multichamber remote control: multichamber WinKratos software installed on a PC (to be supplied upon request) and connection kit for controlling several chambers (up to 16) from the same PC station. Noise reduction system: water-condensed, it allows a 2 4 db (a) reduction of the chamber noise. UV lamp: to be used for ageing tests on painted surfaces, plastic materials, rubber, etc. Correct functioning is within 0 and +40 C. Handling port hole: 150 mm of diameter, it is positioned on the door under the inspection window. It allows the handling of specimens inside the chamber (available for models from 600 litres up). Internal shelves: AISI 304 stainless steel, adjustable in height, grid shelves to be added to the one supplied. Set of no.4 analogic inputs 0 10V for user s data acquisition (no. 1 set max) Set of no. 4 PT100 inputs (no. 1 set max) Set of no. 8 auxiliary contacts (no. 1 set max) 250 l Set of no. 2 auxiliary contacts (no. 1 set max) bench-top models Uninterrutible Power Supply (UPS) for PLC page 4

Control system and user s interface KeyKratos Plus Limited: Hardware 4096 colours with STN tecnology. Faster control 2 types of memory support for storing cycles, recordings, and alarms: Compact Flash, Internal memory Software Touch menu with related pop up screens where necessary Memory capacity to 1000 cycles with 350 segments (on compact flash) User friendly data input during editing, check and administration of cycle. Delayed start of the tests (hh:mm:ss) Messages on scheduled maintenance activities system is available in 6 languages: ITALIAN, ENGLISH, GERMAN, SPANISH, FRENCH, DUTCH PC Winkratos software: WINKRATOS S/W package (running under Windows 2000, XP, VISTA) offers a powerful and flexible control and management system. It allows the user to: create test programs refer to and modify previously created test programs delete all test programs that are no longer necessary print any test program in text format. Main features Connection to PLC through RS232 (RS422 if the PC must be connected to more than one chamber (up to 16, using multi-serial cards). Colour printing on any Windows 2000, XP, VISTA compatible printer. Multiple access password levels. Graphic functions Fully-configurable layout of acquired measures charts. Display of several charts on the monitor. Several colours to be chosen at one s choice for the display of different parameters curves. Enable/disable of chart display and grids. Real-time update of acquired measures charts. Acquisition functions Real-time measurement of test parameters by means of graphic cursors. Max. flexibility for cycles to be set. Storage of occurred events such as alarms, commands, etc. WINKRATOS may be installed on PCs supplied by ACS or belonging to the customer and may be connected to any NEW!!! Ability to add notes on the graphs Delayed start of the tests Optimized view of synoptic graphs Two editing modes: entry-level and advanced page 5

SUNRISE chamber. BASIC SERIES MODEL* SU250 (C) SU340 (C) SU600 (C) SU1200 (C) SU1600 (C) SU2000 (C) Useful capacity (litres) 224 336 557 1152 1535 2040 Int. dim. mm (WxDxH) 600x535x700 600x800x700 850x733x895 1000x1130x1020 1000x1505x1020 1000x2000x1020 Ext. dim. mm (WxDxH) 850x1460x1602 850x1725x1602 1100x1705x1997 1250x2160x2123 1250x2534x2143 1250x3035x2143 Temperature range 40 C/+180 C 40 C/+180 C 40 C/+180 C 40 C/+180 C 40 C/+180 C 40 C/+180 C C version 75 C/+180 C 75 C/+180 C 75 C/+180 C 75 C/+180 C 75 C/+180 C 75 C/+180 C Precision over time (T) ±0,25 ±0,3 C ±0,25 ±0,3 C ±0,25 ±0,3 C ±0,25 ±0,3 C ±0,25 ±0,3 C ±0,25 ±0,3 C Heating Temperature Rate1 ( 40/+180 C) 5 C/min 4,5 C/min 4,5 C/min 4 C/min 3 C/min 2,5 C/min C version ( 70/+180 C) 5 C/min 4,5 C/min 4,5 C/min 4 C/min 3 C/min 2,5 C/min Cooling Temperature Rate 1 (+180/ 40 C) 3,5 C/min 3 C/min 4 C/min 4 C/min 3 C/min 2,5 C/min C version (+180/ 70 C) 2,5 C/min 2 C/min 4 C/min 3 C/min 2,5 C/min 2 C/min R.H. range (τ = 20 2 /+94 C) 10% 98% 10% 98% 10% 98% 10% 98% 10% 98% 10% 98% R.H. precision ±1% ±3% ±1% ±3% ±1% ±3% ±1% ±3% ±1% ±3% ±1% ±3% Int. dissipation T= 25 C 400W 400W 1000W 1300W 1300W 500W C version: T= 55 C 600W 500W 1200W 1500W 1500W 550W Noise dba3 59 59 64 65 65 65 C version 63 63 66 68 68 68 * For temperature only versions(without R.H. control) add the suffix T. 2 Non continuous tests; +2/+94 C for continuous tests 3 Measured at 1 metre from the front in free environment BENCH-TOP version The Sunrise bench-top is the smaller size of the Sunrise series. They have the same excellent performance of the larger chambers and maintain the same electrical and SW interface in order to integrate easily with other ACS chambers through the WinKratos SW and remote PC.They are intended for Environmental Testing of small specimens and can be positioned on the laboratory bench or on optional dedicated trolley. The chambers are mainly dedicated for temperature tests with the possibility to choose two temperature ranges ( 40 C or 70 C up to +180 C). The biggest model can be equipped with humidity control system. They can be easily installed in any laboratory thanks to the light weight of the equipment, low noise and the possibility to plug it in the 230V single phase socket. MODEL SU16 T SU60 T (C) SU160 T (C)* Useful Capacity (l) 16 59,5 178 External Dimension (WxDxH) mm 465x500x670 630x910X1160 840x1130x1420 Internal Useful Dimension (WxDxH) mm 310x230x206 350x340x500 560x564x560 Temperature Range -40 C/+130 C -40 C/+180 C -40 C/+180 C C Version -70 C/+180 C -70 C/+180 C Precision over time (T) ±0.25 ±0.25 ±0.25 R.H. Range in 10 C<T<80 C min Dew point = 5 C - - 20% 95% Heating Temperature Rate 1 (-40/+180 C) 4.5 C/min (-40 C to+130 C) 3 C/min 2.5 C/min C Version (-70/+180 C) 3 C/min 2.5 C/min Cooling Temperature Rate 1 (+180/-40 C) 4.5 C/min (+130 C to-35 C) 3 C/min 1 C/min C Version (+180/-70 C) 3 C/min 1.5 C/min Maximum Internal Dissipation (W) at T=-25 210 (at +20 C) 100 100 C Version at T=-55 C 100 100 Noise Level dba 2 55 60 60 C Version 60 60 * available also with humidity control 2 Measured at 1 metre from the front in free environment page 6

ENERGY SAVING SERIES Sunrise E series have basic environmental performances and require simple utilities connection. They are intended for general applications when high environmental performances are not required. An ideal tool for tropical tests on pharmaceutic products (stability tests), plastic, rubber, paper, semiconductor (85/85). MODEL SU250 E SU340 E SU600 E SU1200 E SU1600 E Useful capacity (litres) 224 336 557 1152 1535 Int. dim. mm (WxDxH) 600x535x700 600x800x700 850x733x895 1000x1130x1020 1000x1505x1020 Ext. dim. mm (WxDxH) 850x1460x1602 850x1725x1602 1100x1705x1997 1250x2160x2123 1250x2534x2143 Temperature range 20 C/+180 C 20 C/+180 C 20 C/+180 C 10 C/+150 C 10 C/+150 C Precision over time (T) ±0,25 ±0,3 C ±0,25 ±0,3 C ±0,25 ±0,3 C ±0,25 ±0,3 C ±0,25 ±0,3 C Heating Temperature Rate 1 (0/+100 C) 1,7 C/min 1,4 C/min 1 C/min 1 C/min 0,7 C/min Cooling Temperature Rate 1 (+100/0 C) 1,7 C/min 1,4 C/min 1 C/min 0,5 C/min 0,3 C/min R.H. range (τ = +2/+84 C) 10% 95% 10% 95% 10% 95% 10% 95% 10% 95% R.H. precision ±1% ±3% ±1% ±3% ±1% ±3% ±1% ±3% ±1% ±3% Int. dissipation T= 0 C 500W 500W 500W 500W 500W Noise dba 2 59 59 59 59 59 2 Measured at 1 metre from the front in free environment ENVIRONMENTAL SCREENING SERIES The Sunrise ES series have superior environmental performances. They are intended for Environmental Stress Screening (ESS) or generally in the reliability growth processes where a 5 C/min is a must. The chambers are equipped with water condenser (remote air condenser as option). MODEL* SU250 ES (C) SU340 ES (C) SU600 ES (C) SU1200 ES (C) SU1600 ES (C) Useful capacity (litres) 224 336 557 1152 1535 Int. dim. mm (WxDxH) 600x535x700 600x800x700 850x733x895 1000x1130x1020 1000x1505x1020 Ext. dim. mm (WxDxH) 850x1460x1602 850x1725x1602 1100x1705x1997 1250x2160x2123 1250x2534x2143 Temperature range 40 C/+180 C 40 C/+180 C 40 C/+180 C 40 C/+180 C 40 C/+180 C C version 75 C/+180 C 75 C/+180 C 75 C/+180 C 75 C/+180 C 75 C/+180 C Precision over time (T) ±0,5 ±1 C ±0,5 ±1 C ±0,5 ±1 C ±0,5 ±1 C ±0,5 ±1 C Heating Temperature Rate 1 ( 40/+180 C) 10 C/min 10 C/min 6,1 C/min 7 C/min 5 C/min C version ( 70/+180 C) 11,5 C/min 10 C/min 7 C/min 6,5 C/min 5,5 C/min Cooling Temperature Rate 1 (+180/ 40 C) 6,1 C/min 5,5 C/min 4 C/min 5 C/min 3,5 C/min C version (+180/ 70 C) 6,6 C/min 5,5 C/min 6 C/min 5,5 C/min 3,5 C/min R.H. range (τ = 20 2 /+94 C) 10% 98% 10% 98% 10% 98% 10% 98% 10% 98% R.H. precision ±2% ±5% ±2% ±5% ±2% ±5% ±2% ±5% ±2% ±5% Int. dissipation T= 25 C 1600W 1300W 2500W 3500W 2600W C version: T= 55 C 2000W 1500W 3500W 4500W 3000W Noise dba 3 60 60 66 67 67 C version 65 65 68 70 70 * For temperature only versions(without R.H. control) add the suffix T before ES. 2 Non continuous tests; +2/+94 C for continuous tests 3 Measured at 1 metre from the front in free environment page 7

SPEEDY SERIES - The right chambers for the real Stress Screening The speedy is a chamber series that can perform stress screening tests according to the main Standards in this field. So those chambers can maintain what they promise without any trouble, thanks to powerful cooling units and ventilation systems that allow to stress the specimen as per the values measured on air. This is a must to ensure a correct stress screening and to avoid big difference between temperatures measured on air and on the specimen, that makes useless the test. ESS has been developed to help manufacturers detecting product defects and production flaws. Screening can force infancy board and component failures that would otherwise occur after final assembly and product delivery, and potentially during the warranty period. Two versions are available, according to the Temperature Rate of Change (10 C/min and 15 C/min) GOALS: To remove all type of defects Not doing damage to otherwise good material Corrective actions on design and production Increase reliability ESS Improves Product quality Product reliability Production throughput Profit margins Customer satisfaction costs ESS Reduces Fields defect Warranty costs Time to market Infancy failures on field Manufacturing MODEL * SU250 TC ESS SU500 TC ESS SU1000 TC ESS SU1400 TC ESS Useful capacity (litres) 252 441 1030 1326 Int. dim. mm (WxDxH) 600x600x700 850x582x892 1000x1010x1020 1000x1300x1020 Ext. dim. mm (WxDxH) 850x1974x1592 1100x1955x2030 1250x2409x2147 1250x2784x2147 Temperature range -70 C/+180 C -70 C/+180 C -70 C/+180 C -70 C/+180 C Precision over time (T) ±0.5 ±1.0 C ±0.5 ±1.0 C ±0.5 ±1.0 C ±0.5 ±1.0 C Heating Temperature Rate 1 10 C or 15 C/min 10 C or 15 C/min 10 C or 15 C/min 10 C or 15 C/min Cooling Temperature Rate 1 10 C or 15 C/min 10 C or 15 C/min 10 C or 15 C/min 10 C or 15 C/min Maximum Internal Dissipation (W) at T= -55 C 10 C/min = 4000 10 C/min = 5500 10 C/min = 7000 10 C/min = 7500 15 C/min = 4500 15 C/min = 6000 15 C/min = 7500 15 C/min = 8000 Noise Level dba 2 70 75 80 80 * All models are available also with humidity control 2 Measured at 1 metre from the front in free environment page 8

DEWPPY SERIES The Dewppy chamber differs from the other series by its humidification system. The control of the relative humidity is done by means of a bath thermoregulated at dew point. These chambers mainly satisfy the needs for severe climatic tests where a high stability and precision of Relative Humidity and Temperature parameters are required. MODEL SU300 DEWPPY (C) SU500 DEWPPY (C) SU1000 DEWPPY (C) Useful capacity (litres) 281 504 1052 Int. dim. mm (WxDxH) 600x676x700 850x665x895 1000x1034x1020 Ext. dim. mm (WxDxH) 850x1725x1566 1100x1705x1961 1250x2160x2086 Temperature range 40 C/+180 C 40 C/+180 C 40 C/+180 C C version 75 C/+180 C 75 C/+180 C 75 C/+180 C Precision over time (T) for thermostatic tests: ±0,25...±0,3 C ±0,25...±0,3 C ±0,25...±0,3 C for climatic tests: ±0,1...±0,2 C ±0,1...±0,2 C ±0,1...±0,2 C Heating Temperature Rate 1 ( 40/+180 C) 4,5 C/min 4,5 C/min 4 C/min C version ( 70/+180 C) 4,5 C/min 4,5 C/min 4 C/min Cooling Temperature Rate 1 (+180/ 40 C) 3 C/min 4 C/min 4 C/min C version (+180/ 70 C) 2 C/min 4 C/min 3 C/min R.H. range (τ = +4/+94 C) 10% 98% 10% 98% 10% 98% R.H. precision ±1%...±2% ±1%...±2% ±1%...±2% Int. dissipation T= 25 C 400W 1000W 1300W C version: T= 55 C 500W 1200W 1500W Noise dba 2 59 64 65 C version 63 66 68 2 Measured at 1 metre from the front in free environment V SERIES BIO-CHAMBERS Control system By two (2) electronic controllers with digital display (one for temperature complete with a PT 100 probe and one for humidity complete with capacitive probe) based on P.I.D. regulation system. Alarm for: open door, maximum pressure and maximum internal temperature. If requested, the regulation can be carried out by the PLC electronic programmer for humidity and temperature cycle operation Purpose Sunrise700 V and 1500 V are primarily used for stability tests in the chemical-pharmaceutical sector. The small external dimensions, easy use, reduced consumption of energy and high reliability of the chambers are the main characteristics for use in research laboratories. All the models proposed comply with ICH regulations. Chamber configuration Back doors are provided with external lock and key. Internal double doors with toughened glass. Internal chamber in stainless steel AISI 304 with internal round off corners for easy cleaning and disinfection. Height adjustable plasticized steel internal shelves. Air treatment system Copper tube battery evaporator, smooth tube for excellent dehumidification, low pressure steam generator (demineralised water at Customer care), electrical heaters and centrifugal blower for air circulation. Refrigeration unit Completely sealed, with silent hermetic compressors using ecologically friendly refrigerants. The air condenser is installed in the machine compartment. MODEL SU700 V SU1500 V Useful Capacity (l) 600 1400 Internal Useful Dimension (WxDxH) mm 590X675X1500 1330X675X1500 External Dimension (WxDxH) mm 740X815X2030 1480X815X1998 Temperature Range ( C) -20 +70 * -10 +70* Precision over time (T) ±0.5 C ±0.5 C Heating Temperature Rate 1 1 C/min 0.5 C/min Cooling Temperature Rate 1 1 C/min 0.5 C/min R.H. Range [10 C<T<55 C] 20 95% 20 95% R.H. Accuracy in time ±3% ±3% Noise Level dba 2 58 58 * under +10 C continuous tests cannot be carried out for more than 24 h 2 Measured at 1 metre from the front in free environment page 9

page 10