Fixed Gas Detection System/Meridian CERTIFICATION

Similar documents
Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

EU DECLARATION OF CONFORMITY

TYPE APPROVAL CERTIFICATE

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Intrinsically Safe Solutions

Dräger Polytron 5700 IR Detection of flammable gases and vapours

official distributor of Newson Gale Ltd.

OLC(T) 100 FIXED GAS DETECTOR

Dräger Polytron 8310 IR Detection of flammable gases and vapour

3M Oldham OLCT 100. Description. Fixed Gas Detector

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Certificate of Compliance

Dräger Polytron 8700 IR Detection of flammable gases and vapors

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.

INSTRUCTION MANUAL (ATEX / IECEx)

Inductive slot sensor

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Certificate of Compliance

IECEx Certificate of Conformity

S5000 Gas Monitor. GMS5000.com

SEC 2000 Millenium Infrared Gas Detector

VQ500 Series Combustible Gas Detector Elements

4) Intrinsic Safety Certification

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

Transmitters/Sensors. OLCT Series

Certification Supplement Manual

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Quick Start Guide. XNX Universal Transmitter

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

SENSOR O2 O2-A

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

SET Installation and Operating Instructions. Level switch for one sensor

Dräger Flame 2100 Flame Detection

Ar-Mite TM Low Flow Armored Flowmeter

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Dräger Polytron 8700 IR Detection of flammable gases and vapors

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Quick Start Guide For the

Safe Operation Manual. Honeywell IQ Force Gas Detector

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Certificate of Compliance

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

IECEx Certificate of Conformity

Dräger Flame 2500 Flame Detection

IECEx Certificate of Conformity

Guide for hazardous areas

Dräger X-am 7000 Multi-Gas Detection

Models TX-KE and TX-KP Toxic Gas Transmitters

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

SET-2000 Oil/Sludge 12 VDC

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Approvals, Certificates and Conditions

Earth-Rite II PLUS Static Earthing System

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

ULTIMA X5000. MSAX5000.com

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Dräger Polytron 5720 IR Toxic Gas Detection

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

Dräger Flame 2500 (IR3) Flame Detection

Certificate of Compliance

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Integrated Solutions Low Voltage Systems

Manual Power relay SR853

INSTRUCTION & SERVICE MANUAL

IR1 Single Gas Series Datasheet

Dräger Polytron 8720 IR Detection of carbon dioxide

Explosion-proof Immersion Heater Type D-8660

Technical Data. General specifications. Rated operating distance s n 5 mm

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2100 (UV) Flame Detection

DB5 Intrinsically Safe Sounder Type DB-5

Dräger Flame 2700 (Multi-IR) Flame Detection

Electrical Installations Design, Selection, Erection and Inspection

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

IECEx Certificate of Conform ity

Annubar Flowmeter Series

OPTIBAR P 1010/2010 C Supplementary instructions

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Polytron 5720 IR Detection of carbon dioxide

Explosion Proof Manual Call Points Series MCP

Instructions. Explosion Proof Smoke Detector U Rev: 9/

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Transcription:

The marking shall include 2 Wire Aluminum Transmitter 3/4 Wire Aluminum Transmitter 2 Wire Stainless Steel Transmitter (PN: 096-3521) (PN: 096-3522) (PN: 096-3525) Ex db [ia Ga] IIC T4 Gb Ex db [ia Ga] IIC T4 Gb Ex db [ia Ma] I Mb Ex tb [ia Da] IIIC T85 C Db Ex tb [ia Da] IIIC T85 C Db Ex db [ia Ga] IIC T4 Gb Ex tb [ia Da] IIIC T85 C Db 3/4 Wire Stainless Steel Transmitters Aluminum Junction Box Stainless Steel Junction Box (PN: 096-3526) (PN: 096-3475) (PN: 096-3520) Ex db [ia Ma] I Mb Ex ia IIC T4 Ga Ex ia I Ma Ex db [ia Ga] IIC T4 Gb Ex ia IIIC T80 C Da Ex ia IIC T4 Ga Ex tb [ia Da] IIIC T85 C Db Ex ia IIIC T80 C Da 2 Wire Detector Head (PN: 096-3484-03 and 096-3484-04) Direct/Integral Connection to Transmitter with E-Chem type sensor only Remote Connection to Transmitter with E-Chem type sensor only Ex db ia I Mb Ex ia I Ma Ex db ia IIC T4 Gb Ex ia IIC T4 Ga Ex ia IIIC T80 C Da Ex ia IIIC T80 C Da 3/4 Wire Detector Head (PN: 096-3484-01 and 096-3484-02) Direct/Integral Connection to Transmitter with any type sensor Remote Connection to Transmitter without IR type sensor Ex db ia I Mb Ex ia I Ma Ex db ia IIC T4 Gb Ex ia IIC T4 Ga Ex ia IIIC T185 C Da Ex ia IIIC T185 C Da Sensors Types All E-Chem Type Sensors (PN: 096-3473-01 thru 096-3474-54) Cat Bead and MOS Type Sensors (PN: 096-3473-55 and 096-3473-57) IR Type Sensors (PN: 096-3473-56 and 096-3473-58) Ex ia I Ma Ex ia I Ma Ex ia I Mb Ex ia IIC T4 Ga Ex ia IIC T4 Ga Ex db ia IIC T4 Gb Ex ia IIIC T80 C Da Ex ia IIIC T185 C Da Ex ia IIIC T110 C Da 3/4 Wire Transmitters PN: 096-3522 and 096-3526, and 3/4 Wire Detector Head PN: 096-3484-01 and 096-3484-02, and Sensor PN: 096-3473-55 and 096-3473-56 shall be marked: Performance assessed per IEC 60079-29-1 when fitted with combustible sensor or equivalent. The system consists of a transmitter, optional cable gland, optional junction box, detector head, and sensors. There is a 2 wire and 3/4 wire version of the system. The 2 wire system is only allowed to have a single E- Chem sensor (PN 096-3473-01 to 096-3473-54) connected. The 3/4 wire system is allowed to have up to three sensors connected in any combination noted in the table below: Date: 6 March 2015 Page 1 of 5

MERIDIAN ¾ Wire Transmitter allowed Sensor Combinations (USE ONLY WITH IS BARRIER ASSEMBLY 096-3448) Sensor #1 Sensor # 2 Sensor # 3 O 2 (096-3473-19) Combustible Cat Bead (096-3473-55) MOS (069-3473-57) IR CO 2 (096-3473-58) Combustible IR (096-3473-56 = WARNING DO NOT USE THESE COMBINATIONS UNDER ANY CIRCUMSTANCES. THEY ARE NOT INTRINSICALLY SAFE AND CAN CAUSE EXPLOSION. *ECHEM SENSOR PART NUMBERS 096-3473-01 THRU 096-3473-18, 096-3473-20 THRU 096-3473-54 AND SENSOR SIMULATOR 096-3395 **OXYGEN SENSOR PART NUMBER 096-3473-19 Transmitter The transmitter is a flame-proof device that houses the power supply, display, optional communications, and the intrinsic safety barriers that limit the energy to the detector head/sensors. The different models of the transmitter are outlined below: Part Number 096-3521 2 Wire Transmitter Aluminum Housing 096-3522 3/4 Wire Transmitter Aluminum Housing 096-3525 2 Wire Transmitter Stainless Steel Housing 096-3526 3/4 Wire Transmitter Stainless Steel Housing Junction Box The Junction Box is an optional component that can be used in a remote connection of a single sensor in a 2 wire or 3/4 wire system. It is also used in 3/4 wire system when more than one sensor is to be used. All power in the Junction box is intrinsically safe and is limited from the IS barriers located in the transmitter. There are two different versions of the junction box. The only difference between the models is the housing. Below are the model numbers and descriptions. Part Number 096-3475 Junction Box Aluminum Housing 096-3520 Junction Box Stainless Steel Housing Date: 6 March 2015 Page 2 of 5

Detector Head The detector head is the housing/interface for all the sensor modules. The detector may be installed directly to the transmitter. In this situation, the detector head incorporates a flame-proof cable gland and no further seal or stopping box is required, it may also be located remotely from the transmitter. There are fundamentally two versions of the Detector Head. There is a 2 wire version and a 3/4 wire version. In addition, each of these detector heads is allowed to use either the stainless steel (PN 096-3437-2) or non-metallic (PN 096-3437-1) end caps. Below are the model numbers and descriptions. 096-3484-01 3/4 Wire Detector Head with non-metallic end cap (PN 096-3437-1) 096-3484-02 3/4 Wire Detector Head with stainless steel end cap (PN 096-3437-2) 096-3484-03 2 Wire Detector Head with non-metallic end cap (PN 096-3437-1) 096-3484-04 2 Wire Detector Head with stainless steel end cap (PN 096-3437-2) Sensors All the sensors are required to be installed inside the detector head. Any of the sensors noted below will connect to the detector head. E-Chem These sensors are typical electro-chemical type sensors used to sense both toxic gases and oxygen. These may be used with either the 2 wire or 3/4 wire systems. MOS This sensor may only be used with the 3/4 wire system. This sensor utilizes a H2S sensor (Synkera, PN 727-1). Cat Bead This sensor may only be used with the 3/4 wire system. This sensor utilizes a LEL combustible gas sensor (SGX, PN VQ548ZD). IR Combustible This sensor may only be used with the 3/4 wire system. The sensor utilizes an IR sensor (SGX, PN IR12GJS). IR CO2 This sensor may only be used with the 3/4 wire system. The sensor utilizes an IR sensor (SGX, PN IR11 GJS). 096-3473-01 thru 096-3474-54 (54 in total) E-Chem Sensor 096-3473-55 Cat Bead Sensor 096-3473-56 IR Combustible Sensor 096-3473-57 MOS Sensor 096-3473-58 IR CO 2 Sensor Date: 6 March 2015 Page 3 of 5

Accessories Cable Gland This cable gland is used on the transmitter when a remote installation is required. 096-3483 Cable Gland Sensor Simulator The sensor simulator may be used with either the 2 wire or 3/4 wire system. This device is intended to be used to perform maintenance functions with the system only. 096-3395 Sensor Simulator Certified Ex Components Manufacturer Approval Details Certificate Comments Transmitter (Stainless Steel IECEX KDB 13.0006U Transmitter (Aluminum Junction Box (Stalnless Steel Junction Box (Aluminum IR Sensor Kernel (Combustible) Limatherm XD-S120win Ex d I Mb Ex d IIC Gb Limatherm XD-120win Ex d IIC Gb IP68 International Metal Engineering (IME) 7092 Ex d IIC Gb Limatherm XD-JBBS Ex d IIC Gb Ex tb IIIC Db IECEx FTZU 11.0012U IECEX SIR 08.0025U IECEX FTZU 09.0028U SGX IR12GJS Ex d IIC Gb IECEX SIR 04.0031U IR Sensor Kernel (CO2) SGX IR11GJS Ex d IIC Gb IECEX SIR 04.0031U -50 C Ta 85 C (with VMQ D-Rlng) -40 C Ta 85 C -40 C Ta 85 C -40 C Ta 100 C -40 C Ta 75 C Lamp Circuit: Ui = 7.2 Volts, Detector Circuit: Ui = 10 Volts, Lamp & Detector: Pi = 1.5Watts -40 C Ta 75 C Lamp Circuit: Ui = 7.2 Volts, Detector Circuit: Ui = 10 Volts, Lamp & Detector: Pi = 1.5Watts Date: 6 March 2015 Page 4 of 5

Conditions of Certification i. All openings to the transmitter and junction box must sealed using suitable flame-proof, type d stopping boxes or type d glands with a minimum IP rating of. ii. Transmitter must be bonded to ground both internally and externally with suitably sized conductors (IEC 60079-0, cl. 15.3) iii. The 2 wire system may only be used with a single electrochemical sensor and must be installed in accordance with control drawing 096-3507-B. iv. The 3/4 Wire system may be used with one to three sensors and must be installed in accordance with control drawing 096-3506-B. v. Sensors may only be installed or removed when the area is clean and dry. vi. All wiring used must be specified in accordance with the following conditions: For Installations Ta < 60 C: Temperature rating of wire must be equal to or greater than 105ºC. For Installations Ta 60 C: Temperature rating of wire must be equal to or greater than 120ºC. For Input Power and Relay: Use field wire 18 AWG (1.0 mm 2 ) min For Communications: Use field wire 24 AWG (0.2 mm 2 ) min vii. The equipment shall be regularly cleaned to ensure there is no dust accumulated on the surface in excess of 5mm. Accessories: viii. The sensor simulator is only for temporary use under direct supervisions with the following conditions: Only to be used in clean and dry environments It must be protected from impact Conditions Of Manufacture i. The intrinsic safety barriers are required to be 100% tested to verify proper operation and the nominal resistance of the fuse verified. ii. Each batch of Potentiometers (Honeywell, PN 392JB5K) must be tested to verify the following: Inductance 60.0mH iii. Each batch of MOS Sensors (Synkera, PN 727-1) must be tested to verify the following: Inductance: 2.0µH (Pins 1 to 3) Capacitance: 0.5µFcombined (Pin 1 to 4, Pin 2 to 3, and Pin 2 to 4) iv. Each batch of CAT Bead Sensors (SGX, PN VQ548ZD) must be tested to verify the following: Detector Inductance: 1.0µH Comparator Inductance: 1.0µH v. The aluminum transmitter housing (Limatherm, PN XD-120win) shall be subject to 100% routine overpressure testing to a minimum pressure of 15.12 Bar in accordance with IEC60079-1, CI. 15.1.3. As result, there shall be no leakage through the walls of the enclosure, damage, or deformation to the joints or housing. Date: 6 March 2015 Page 5 of 5