Seradens Super Seradens Super Plus

Similar documents
24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Circulation Pump Optima

2-Pass CGS2 series kw Low Temperature Boiler. Gas and Liquid Fuel Steel Boiler

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

1 VICTRIX ZEUS Superior kw I features

VICTRIX Superior kw Export VICTRIX Superior kw X Export

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

SPECIFICATIONS - NIKE

ENERGY TOP. Condensing boiler solutions

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

WOLF GAS CONDENSING BOILERS COMFORTLINE

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Power X High Power Condensing Wall-Hung Boilers

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Power X High Power Condensing Wall-Hung Boilers

white blue cobalt bordeaux light oak (rovere)

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

The mechatronics of EVE 05

Ciao Green Condensing Wall-Hung Boilers

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

HIGH OUTPUT. Skin design RANGE

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

The iqe Boiler Range. Combination and System T Boilers.

C Tahiti. condensing

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

Exclusive Green E Condensing Wall-Hung Boilers

FAMILY PRO SIMPLY THE BEST

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

DOMESTIC HOT WATER Follow operational sequence

Bluehelix Tech Wall-hung premix condensing boilers, only heating or instant combi operation

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

2530C / 3035C / 3540C. Condensing ErP Boilers. Enerwa EnerwaPlus

New Zealand Sales Hotline: Sales Fax:

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

RIELLO 40 GS/M SERIES

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

Ideasandformsinevolution

Residential Heating Boilers

CITY OPEN - CITY BOX from 25 to 35 kw

ACCUMULATION OF EUROPEAN CLASS

Condensing, pre-mixed, wall-hung gas boilers with water tank

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

User Manual for model

THE PERFECT CONDENSATION

TopGas Wall Hung Condensing Gas Boiler

TAHITI CONDENSING KR 55 - KR 85

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Mynute Green Condensing Wall-Hung Boilers

FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE BOILERS

Gas-Fired Condensing Boilers A Green Start to Space & Water Heating

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

Baxi 600, 400 & 200 boilers. Range guide

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

INDEPENDENT COMBINATION & SYSTEM BOILERS.

MINORCA KC - KR - KRB 24

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

HEAT ONLY & COMBI BOILER

PCH/new Series. High performance, total flexibility

MySMART Condensing Wall-Hung Boilers

Easicom 2. Quality, Reliability, Flexibility

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

FINNED WATER-TUBE POOL HEATERS

gas condensing combi boiler

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

3 Pass CGS3 Series kw Low Temperature Boiler. Gas and Liquid Fuel Steel Boiler

10 : 1 Turndown Ratio

FCX FUEL OIL CONDENSING BOILER RANGE

Crossover. Hybrid Water Heater. High Efficiency. Advanced Heating & Hot Water Systems.

THE PERFECT CONDENSATION

Domestic heating solutions

Greenstar The World's Best Selling Condensing Boiler System

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

Super high efficiency heating and hot water boilers for every type of home and commercial property.

Transcription:

Premix Full Condensing Combi Boilers Seradens Super Seradens Super Plus 20-28 - 36 kw THE FIRST CONDENSING TECHNOLOGY BOTH IN HEATING AND DOMESTIC HOT WATER IN TURKEY

Smaller, more elegant and efficient New Seradens Elegant and modern design Stainless steel exchanger with long service life and high resistance against condensate water Capacities of 20, 28 and 36 kw ( at 50/30 C) Ideal gas-air mixture, high efficiency, low noise level, low flue gas temperature and low emission rate thanks to the premix system, environmentally friendly product High efficiency proved by the very low flue gas temperature (flue gas temperature reduced up to 40 C) Minimum stop and start operations, maximum fuel saving with the very extensive heating modulation range that goes from 17% to 100% Capability to make use of solar energy in the heating of domestic hot water with the solar energy connection set (using optional solar connection set and an additional hot water tank) Pre-heating function for domestic hot water Higher pump head Plain and simple lines

Premix Full Condensing Combi Boilers Bigger expansion tank Capability to operate under lower flow rate Higher heating modulation range More hot water Higher heating efficiency Maximum domestic hot water efficiency (in Seradens Super Plus models) Less fuel consumption White illuminated LCD display Digital manometer Ease of demonstration and explanation in showrooms with the demo mode Opentherm remote control connection Complies with EN 15502 norm (gas fired boilers with a rated heat load under 1,000 kw) Compatible for natural gas and LPG Certified for EMC (Electro Magnetic Compatibility) and LVD (Low Voltage Directive) from a certification body Her açıdan mükemmel, iddialı, kuvvetli ve öncü Perfect, assertive, strong and pioneer in all aspects eco mod allows practical and economic setting of both heating and domestic hot water Efficiency over a 100% with condensing techno logy both in heating and domestic hot water for the first time in Turkey

Operating mode setting button (Summer / Winter / Heating Only / Off / Reset) Control Panel Domestic hot water temperature increase button 1 3 5 Heating water temperature increase button 2 7 4 6 Info menu entry button LCD display for Domestic hot water temperature, error temperature decrease button codes and operating mode Heating water temperature decrease button

Seradens Super Operating Diagram 14 11 10 15 2 1 4 26 5 3 6 7 25 17 24 22 9 21 13 16 8 23 CW YS HF KG WO KS G WI SS KD HR 12 20 18 19 1- Main exchanger 2- Premix burner unit (gas manifold + burner) 3- Condensation drainage pipe 4- Ionization and ignition electrode 5- Fan 6- Venturi 7- Electronic gas valve 8-3 bar safety valve 9- Automatic air vent 10- Limit thermostat 11- Heating flow temperature sensor 12- Circulation pump 13- Pressure sensor 14- Flue fuse 15- Expansion tank 16- DHW temperature sensor 17- Siphon 18- Drainage tap 19- Flow limiter 20- Electronic flow sensor 21- DHW plate exchanger 22-3 way valve motor 23- Water filling tap 24- Gas inlet pipe 25- Heating flow pipe 26- Heating return pipe

Operating mode setting button (Summer / Winter / Heating Only / Off / Reset) Domestic hot water temperature increase button Control Panel Heating water temperature increase button Info menu entry button 1 3 5 2 4 7 6 8 Domestic hot water temperature decrease button LCD display for temperature, error codes and operating mode Heating water temperature decrease button eco (economy) mode on-off button (upper limit as 50 C for radiator system and 38 C for underfloor heating system, fixed 45 C for domestic hot water)

Seradens Super Plus Operating Diagram 14 11 10 15 2 4 1 26 5 7 25 24 3 6 28 27 17 22 9 21 13 16 8 23 CW YS HF KG WO KS G WI SS HR KD 12 20 18 19 1- Main exchanger 2- Premix burner unit (gas manifold + burner) 3- Condensation drainage pipe 4- Ionization and ignition electrode 5- Fan 6- Venturi 7- Electronic gas valve 8-3 bar safety valve 9- Automatic air vent 10- Limit thermostat 11- Heating flow temperature sensor 12- Circulation pump 13- Pressure sensor 14- Flue fuse 15- Expansion tank 16- DHW temperature sensor 17- Siphon 18- Drainage tap 19- Flow limiter 20- Electronic flow sensor 21- DHW plate exchanger 22-3 way valve motor 23- Water filling tap 24- Gas inlet pipe 25- Heating flow pipe 26- Heating return pipe 27- DHW water pre-heating inlet pipe 28- DHW water pre-heating outlet pipe

Main Components Electronic Card Main Exchanger Seradens Super and Seradens Super Plus series combi boilers use state-of-the-art electronic board by Nordgas. Electronic board allows displaying of operating modes and temperatures, ambient temperature, warnings and error messages on the elegant, white LDC display. Monitors the boiler continuously for safe, comfortable and high efficiency operation. Compatible both for radiator and underfloor heating systems with standard (30-85 C) / reduced (30-45 C) heating temperatures User info menu Service info menu Seradens Super Plus models have eco mode Demo mode Continuous flame modulation during heating and domestic hot water cycles Automatic flame control system Initial power increase time (ramp time) setting for heating cycle Pre-heating function for domestic hot water Activation delay period setting for heating cycle Heating anti-freeze function Domestic hot water anti-freeze function Circulation pump anti-locking function 3-way diverting valve anti-locking function Pump overrun feature for heating cycle Pump overrun feature for domestic hot water cycle Heating circuit low water pressure safety Heating circuit high water pressure safety (two stages) Fault reporting with error codes (self-diagnostic) Remote controller communication channel (opentherm protocol) Outside temperature compensation function (with using optional outside sensor) Selection of gas type Chimney sweeper function Parameters programming function Sermeta brand. With smooth oval pipes, made of long service lifed stainless steel resistant against condensate water. Highly efficient, durable, resistant against shocks. Seradens Super Plus models have additional exchanger coils for condensation in domestic hot water generation. Efficiency is increased even more with less radiation losses thanks to the cold burner door on the front cover side. Provides maximum safety for you and your boiler with the integrated flue and safety fuses. Exchanger s burner is the patented, very quiet Bluejet burner with a long service life developed by Sermeta. CO and NOx emissions caused by burning are reduced to minimum level. Quick maintenance is possible with easy access to combustion chamber by removing a few nuts. Seradens Super Exchanger Seradens Super Plus Exchanger Fan-Venturi-Gas Valve Assembly Required amount of gas-air mixture is provided as per the boiler capacity with the EBM made modulated fan integrated in the assembly. Fan speed is increased or decreased as per capacity. Thus, low noise level is maintained besides preventing low efficiency caused by excess air. Gas valve provides the gas flow required for combustion safely as per the modulating fan that changes according to the capacity With the venturi, ideal gas-air mixture rate of 1:10 is provided in a fixed fashion throughout whole capacity range. This is the most important point that ensures efficient and clean burning.

Seradens Super and Seradens Super Plus models have the same flow blocks, but different return blocks. Flow and return hdyraulic blocks made of brass are much more durable and have a longer service life than plastic blocks. Service interventions, removal and installation operations are performed more easily and safely. Circulation pumps with three stages and automatic air vent have pump heads of Hydraulic Circuit 4.8-4.4-4.7 mwc respectively for capacities of 20, 28 and 36 kw. Thus, pump shall suffice for houses with two or three floors. 20, 28 and 36 kw models use three different types of domestic hot water plate exchangers selected for comfortable and abundant domestic hot water usage. For example, 28 and 36 kw models produce 17, 18 and 21 l/min domestic hot water which cannot be achieved by many boilers. Amount of hot water produced with high flow rate cancels the requirement for using hot water tanks in may projects Thus, first investment cost is reduced besides saving from fuel that shall be used for keeping hot water tank warm continuously. Automatic bypass that takes place through the plate exchanger allows continued circulation even if all radiator valves are closed. Seradens Super Capacity kw Flow Rate (m 3 /h) Pump Head (mwc) 3-Way Valve Motor 3 4 Electronic Flow Sensor Pressure Sensor 8 9 Pump 20 0,86 4,8 28 1,20 4,4 36 1,50 4,7 6 5 20-28 kw 1 Flow Block 7 5 DHW Temperature Sensor Filling Tap 10 Plate Exchanger 2 11 Flow Limiter Return block Pump Head (m) 4 3 2 1 I II 0 0 0,5 1 1,5 2 2,5 Flow Rate (m 3 /h) III 6 3 Bar Safety Valve 7 6 36 kw Seradens Super Plus 3-Way Valve Motor 3 Electronic Flow Sensor 8 9 Pump Pump Head (m) 5 4 3 2 1 I II III 4 Pressure Sensor 0 0 0,5 1 1,5 2 2,5 Flow Rate (m 3 /h) 13 DHW Pre-heating Return 2 Return block 11 Flow limiter 7 5 DHW 1 Temperature Flow Block 7 Sensor 3 Bar Safety Valve Filling Tap 12 DHW Pre-heating Flow 10 Plate Exchanger Expansion Tank Expansions tanks with a capacity of 8 litre used for 20 and 28 kw models and 10 litre used for 36 kw models allow expansion of very large installations, no problem occurs.

Flue Sets and Various Flue Set Accesories for Your Need Ø 60/100 Horizontal Concentric Flue Set Ø 80/125 Horizontal Concentric Flue Set Reduced from Ø80 to Ø60 in inner elbow vertical connection. Condensation water is not collected and does not drip No reduction in between. Condensation water is not collected and does not drip Provided as standard with the appliance for SRS/SSP 20 and 28 types If requested, can be changed with another set on order Maximum linear flue set length: SRS/SSP 20: 6 m. SRS/SSP 28: 5 m. Linear length of additional elbows: 90 elbow: 0.8 m. 45 elbow: 0.5 m. Provided as standard with the appliance for SRS/SSP 36 type If requested, can be changed with another set on order Maximum linear flue set length: SRS/SSP 36: 8 m. Linear length of additional elbows: 90 elbow: 0.8 m. 45 elbow: 0.5 m. Ø60/100 Vertical Concentric Flue Set Ø80/125 Vertical Concentric Flue Set Ø80+80 Twin Flue Set If requested, can be changed with standard set on order Maximum linear flue set length: SRS/SSP 20: 6 m. SRS/SSP 28: 5 m. Linear length of additional elbows: 90 elbow: 0.8 m. 45 elbow: 0.5 m. If requested, can be changed with standard set on order Maximum linear flue set length: SRS/SSP 36: 8m. Linear length of additional elbows: 90 elbow: 0.8 m. 45 elbow: 0.5 m. If requested, can be changed with standard set on order Maximum linear flue set length: SRS/SSP 20/28/36: 50 m. Linear length of additional elbows: 90 elbow: 1.5 m. 45 elbow: 1.2 m.

Flue Connection Types C33x C33x C13x B23 C43x C53x B33 C83x C43x C53 C13x B33 C93x C83x Flue Type B23 B33 C13(x) C33(x) C43(x) C53(x) C63(x) C83(x) C93(x) Description Flue gas pipe through the chimney, combustion air directly from the location through the device (open type). Flue gas pipe through the chimney, combustion air from the location, with horizontal concentric connection (open type). Horizontal combustion air intake and flue gas discharge through side face or from the roof. Outlets are close to each other, at the same pressure area. Combustion air intake and flue gas discharge with vertical outlet. Outlets are close to each other, at the same pressure area. Combustion air and flue gas connections connected to multiple air-flue gas chimney system. Combustion air intake and flue gas discharge with different lines. Outlets are at different pressure areas. Connection design as per appliances where combustion air intake and flue gas discharge cannot be measured. Flue gas installation is independent or with multiple connections (under pressure) and intake of independent combustion air from external environment. Similar to C33 type combustion air intake and discharge of flue gas from the roof. Outlets are close to each other, at the same pressure area. Combustion air intake is through the building shaft on the roof partially or as a whole.

Automatic Control Devices for Superior Comfort and Extra Economy Room Thermostat Wired and Wireless Weekly Programmable Room Thermostat Operates the combi boiler according to the required room temperature. Operates the combi boiler according to the required room temperature in the required weekly schedules. Phone Control Interface Devices Outside Temperature Sensor These allow remote controlling of combi boilers in a simple way, such as on or off. There are two models that can work with fixed lines or GSM lines. Operates the combi boiler automatically according to the weather conditions. May be used together with room thermostats or individually. Smart Thermostat Set With your smart thermostat, you may control your combi boiler from your smart phone or tablet wherever you are in the world. You may access and change the current temperature settings or timing schedules. *Devices are optional.

Solar Connection Set (Accessory) Combi Boiler It is possible to obtain DHW much more economically using solar energy with the Seradens Super or Seradens Super Plus combi boilers. In order to achieve this, just collect the solar collector and hot water tank to the solar connection set procured as an accessory as shown the diagram on the left. No electronic control system is required. The diverting valve on the solar connection set directs the water in the tank to the mixing valve directly if the water temperature in the tank is over 48 C. Thermostatic mixing valve mixes this water with cold water and sends DHW at a fixed temperature of 38 C to the taps and prevents accidents that may be caused by high temperature. If the water temperature in the tank is lower than 48 C, diverting valve directs the DHW to the combi boiler to heat it by the combi boiler. DHW coming out of the combi boiler reaches the taps by passing through the thermostatic valve again so that its temperature is set. Thermostatic valve can be adjusted from 30 to 56 C. Solar Collector Valvular Mixing- Diverting Group Hot Water Tank Cold Water Inlet Solar Connection Set

THE DIFFERENCE OF PREMIX CONDENSING TECHNOLOGY The temperature of flue gas generated by the combustion for conventional (non-condensing) combi boilers with copper or titanium exchanger is about 120 to 150 C regardless of the operating temperature of the boiler. With this high temperature, energy and fuel cost on the water vapor inside the flue gas just flies away, too. However, for premix, i.e. full condensing combi boiler with gas-air pre-mixing feature, flue gas temperature are lowered under 55 C while generating flow water temperature at about 50 C and lower thanks to the exchangers with much wider heat transfer surface. For flue gas temperatures under 55 C, the water vapour inside the flue gas condenses, i.e. transforms to liquid from gas form. Thus, energy is captured before going out of the flue, and transferred to the water inside the exchanger. This is called concealed heat energy. By regeneration of energy inside the water vapour, it is possible to save up to 30% from fuel costs. As the condensate water is acidic, main exhangers to premix full condensing combi boilers shall be made of stainless steel or aluminium alloy resistant to acidic condensate water. Alarko Seradens Super and Seradens Super Plus condensing combi boilers use stainless steel main exchanger with very high resistance against condensate water. Combustion is always performed ideally with the premix system, i.e. premixing of gas and air at the ideal ratio of 1:10 before the combustion. This is ensured by the modulating fan which adjusts its speed as per the capacity requirement and the venturi which mixes the gas taken by the drawing of the fan from the modulating gas valve and air in the ideal ratio. Premix condensing boilers do not perform condensing while generating domestic hot water. However, in Seradens Super Plus double condensing combi boiler models, the domestic hot water entering the boiler is passed through the full condensing stainless steel exchanger coils integrated in addition to the main exchanger, and thus both pre-heating and condensing are achieved. Flue gas temperatures are reduced up to 18 C while generating domestic hot water for these models. This proves how efficiently the appliance operates. However, gas and air mixture cannot be performed at ideal ratios in conventional (non-condensing) combi boilers. Because, the fan providing the air has only one stage. Even if gas is drawn less or more as per the capacity requirement from the modulating gas valve, fan always blows the air at maximum capacity. Therefore, efficiency is lower a great deal for these type of boiler as the air is provided more than normal especially while working in lower capacities. Fuel costs are increased. Noise levels are higher. As copper exchangers that are not resistant to condensate water are used for boilers with recuparators, i.e. boilers with an additional small exhanger to the main exchanger of the boiler, also known as boilers with three exchangers, condensation does not occur on the main exchanger. Flue gas is put through the combi boiler return water in the additional exhanger, and thus a small amount of condensation occurs. However, as modulating fan, venturi and premix burner are not available in boilers with three exchangers, flue gas temperature, harmful flue gas emissions and noise level are much higher than premix condensing boiler, and efficiency is much lower. These types of boilers can achieve 102-103% efficiency level. Theoretical efficiency that can be achieved for premix full condensing boilers is 111%. Seradens Super and Seradens Super Plus boilers have the highest efficiency in the condensing boiler technology with their efficiency up to 109.2%. Flue gas temperatures are between 40 and 67 C at this time. Efficiency increase up to 111%

Premix burner used in full condensing combi boilers burn the gas-air mixture supplied as mixed in the ideal ratio with a very small flame size. Low flame size both ensures lower noise levels and reduces the harmful flue gas emissions caused by combustion to the minimum level. Does not cause air pollution. Protects the nature. Conventional (Non-Condensing) Combi Boiler Convection loss 8% Total 92% efficiency Gas 111% 11% Unused condensing heat Air Efficiency: 90 to 92% (approx.) Flue gas temperature: 120 to 150 C Risk of intoxication for open chamber flue types High flue gas emission (non-environmentally-friendly) Low combustion efficiency due to fixed natural gas - air mixture ratio Total efficiency 109,2% Seradens Super / Super Plus Premix Condensing Combi Boiler Convection loss 0,8% Used condensing heat 11,3% Efficiency 97,9% Gas 111% 1% Unused condensing heat Air Efficiency: 105.9-109.2% Flue gas temperature: 40-67 C (at 50 / 30ºC operating range) Hermetic - no flue gas intoxications Low flue gas emission (environmentally-friendly) High combustion efficiency due to premix ideal natural gas - air mixture Condensation of flue gas caused by low flow water temperature

Dimensions H H Technical Specifications D W SERADENS SUPER W D SERADENS SUPER PLUS MODEL UNIT SRS 20 SRS 28 SRS 36 SSP 20 SSP 28 SSP 36 CE Certificate No. no 1312CR6123 1312CR6123 1312CR6123 1312CR6123 1312CR6123 1312CR6123 Flue Connection Types B23 - B33 - C13 - C13(x) - C33 - C33(x) - C43 - C43(x) - C53 - C53(x) - C63 - C63(x) - C83 - C83(x) - C93 - C93(x) Device Category II2H3B/P II2H3B/P II2H3B/P II2H3B/P II2H3B/P II2H3B/P DHW Load Max. kw 21 29.3 37.7 20.6 27.6 34.7 Heating Load Min. (50/30 C) kw 3.9 (G20) - 5.5 (G30) 5.5 (G20) - 8.15 (G30) 5.7 (G20) - 8.89 (G30) 3.92 (G20) 4.44 (G30) 5.57 (G20) 7.36 (G30) 5.79 (G20) 7.84 (G30) Heating Power Min. (50/30 C) kw 4.0 (G20) - 3.74 (G30) 5.7 (G20) - 5.19 (G30) 6.0 (G20) 6.78 (G30) 4.01 (G20) - 3.04 (G30) 5.97 (G20) - 5.59 (G30) 6.17 (G20) 5.92 (G30) Heating Load Max. (50/30 C) kw 18.5 26.0 32.8 18.54 26.11 32.86 Heating Power Max. (50/30 C) kw 20.1 27.9 35.3 20.18 27.90 35.72 Efficiency at 100% Load (50/30 C) % 109.2 107.3 107.6 108.8 108.7 108.7 Efficiency at 30% Load (50/30 C) % 106,8 106,3 105,9 108,7 107,2 107,7 Heating Modulation Range (50/30 C-G20) % 19.9-100 20.4-100 17.0-100 19.9-100 21.4-100 17.3-100 Heating Power Max. (80/60 C) kw 18.1 25.5 32.2 18.15 25.86 33 Heating Power Min. (80/60 C) kw 3.7 (G20) 2.92 (G30) 5.3 (G20) 5.19 (G30) 5.5 (G20) 5.98 (G30) 3.52 (G20) 2.67 (G30) 5.33 (G20) 5.05 (G30) 5.47 (G20) 5.48 (G30) Efficiency at 100% Load (80/60 C) % 97.9 97.9 98.03 97.82 98.82 99.23 Flue Gas Temperature (50/30 C,min-max) C 49.5-59 44-66.6 55-63 44-49 40-49 43-49 Flue Gas Temperature (80/60 C,max) C 82 82 82 64 68 65.5 Sound Level db (A) 39-42 39-42 39-42 39-42 39-42 39-42 Heating Circuit Heating Temperature Setting Range (min. - max.) C 30-85 / 30-45 30-85 / 30-45 30-85 / 30-45 30-85 / 30-45 30-85 / 30-45 30-85 / 30-45 Max. Heating Operating Temperature C 95±4 95±4 95±4 95±4 95±4 95±4 Expansion Tank Capacity liter 8 8 10 8 8 10 Max. Operating Pressure (Heating) bar 2.8 2.8 2.8 2.8 2.8 2.8 Min. Operating Pressure (Heating) bar 0.5 0.5 0.5 0.5 0.5 0.5 DHW Circuit (Automatic bypass feature) DHW Temperature Setting Range (min. - max.) C 30-60 30-60 30-60 30-60 30-60 30-60 Max. Hot Water Operating Pressure bar 10 10 10 10 10 10 Min. Hot Water Operating Pressure bar 0.5 0.5 0.5 0.5 0.5 0.5 Hot Water Flow Rate at ΔT 30 K liter/minute 10 14 18 12 17 21 Dimensions Width mm 437 437 437 437 437 437 Height mm 640 640 640 640 640 640 Depth mm 296 296 296 302 366 366 Weight (net) kg 29 30 32 33 35 36 Hydraulic Connections Heating Flow Ø 3/4 3/4 3/4 3/4 3/4 3/4 Heating Return Ø 3/4 3/4 3/4 3/4 3/4 3/4 Cold Water Inlet Ø 1/2 1/2 1/2 1/2 1/2 1/2 DHW Outlet Ø 1/2 1/2 1/2 1/2 1/2 1/2 Gas Inlet Ø 1/2 1/2 1/2 1/2 1/2 1/2 Flue Systems Horizontal - Concentric Flue System Ø mm 60/100 60/100 80/125 60/100 60/100 80/125 Max. Flue Length m 6 5 8 6 5 8 Twin Flue System Ø mm 80+80 80+80 80+80 80+80 80+80 80+80 Max. Flue Length (from terminal to terminal) m 50 50 50 50 50 50 Vertical Concentric Flue System Ø mm 60/100 60/100 80/125 60/100 60/100 80/125 Max. Flue Length m 6 5 8 6 5 8 Gas Supply Natural Gas G20 Inlet Pressure mbar 20 20 20 20 20 20 Gas Consumption m³/h 2 2.8 3.57 2 2.82 3.55 LPG G30 Inlet Pressure mbar 30 30 30 30 30 30 Gas Consumption kg/h 1.28 1.85 2.36 1.19 1.83 2.27 Power Supply Electrical Connection V/Hz 230/50 230/50 230/50 230/50 230/50 230/50 Power Consumption W 113 121 123 125 134 140 Protection Class IP X4D X4D X4D X4D X4D X4D Manufacturer reserves the right to change any product specifications without notice. ALARKO CARRIER SANAYİ VE TİCARET A.Ș. GOSB-Gebze Organize Sanayi Bölgesi Șahabettin Bilgisu Cad. 41480 Gebze-Kocaeli/TURKEY Phone : (90)(262) 648 60 00 PBX Telefax : (90)(262) 648 61 01 web : www.alarko-carrier.com.tr e-mail : info@alarko-carrier.com.tr A.1.4.11i 080916 MiNERAL