Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Similar documents
Micropower Omnipolar Digital Hall-Effect Sensor ICs

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

FEATURES AND BENEFITS

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

HIH-5030/5031 Series Low Voltage Humidity Sensors

FSS-SMT Series. Low Profile Force Sensor

V-Basic Standard V15 Series

HIH-4000 Series Humidity Sensors

Linear Current Sensors

HOA6480 Series Barcode Sensor Infrared Products

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

HIH-4602-L Series Humidity Sensors


Potential Applications

Issue B. Bipolar Hall-Effect Digital Position Sensor ICs: SS41, SS41-L, SS41-T2, SS41-T3, SS41-S, SS41-SP. Sensing and Internet of Things

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

HFX Fiber Optic Component 50 Mbps, 650 nm LED

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

MICRO SWITCH GSX Series

MICRO SWITCH GLL Series

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

High Temperature Industrial VRS Magnetic Speed Sensors

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-T3 SS460S-LP

MICRO SWITCH V15W Series Watertight Miniature Switches

PRODUCT TRAINING MODULE: Linear Hall-effect Sensor ICs SS39ET, SS49E, SS59ET Series

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

Installation Instructions for the 600 Series Optical Encoders

Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

General Purpose Industrial VRS Magnetic Speed Sensors

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

HIH-4030/31 Series Humidity Sensors

HIH-4602 A & C Series.

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Installation Instructions for the

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Magnetoresistive Sensor ICs 2SS52M Series Issue 2. Datasheet. Sensing and Productivity Solutions

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

Airflow Sensors Line Guide

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

HIH-4010/4020/4021 Series Humidity Sensors

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Interactive Catalog Replaces Catalog Pages

Airflow Sensors Line Guide

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Wireless Panel-Mount Monitor

Interactive Catalog Replaces Catalog Pages

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

WARNING MISUSE OF DOCUMENTATION

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Installation Instructions for the

MICRO SWITCH NT Series

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

MICRO SWITCH NT Series

AMR 4-Pin Quadrature Sensor Integrated Circuit

Sensing and Control. Figure 1. SMART Position Sensor, 100 and 180 Arc Configurations

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

MICRO SWITCH BX/BX2 Series

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

Intrinsically Safe Transmitters, Option Code 2n

LCZ Series Hall-effect Zero Speed Sensors

CONDUCTIVITY SPECIFICATIONS TEMPERATURE SPECIFICATIONS. PDFINFO p a g e

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

MICRO SWITCH Basic Switches Line Guide

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Force Sensors Line Guide

TruStability Board Mount Pressure Sensors

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Quadrature Speed and Direction Sensors

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

Selecting Honeywell Board Mount Pressure Sensors

Guide to Hazardous Location Approvals:

MICRO SWITCH BAF/DTF Series

Sensor Evaluation Kit, SEK001

Transcription:

DESCRIPTION The SS39ET/SS49E/SS59ET Series Low-cost Linear Halleffect sensors are small, versatile devices that are operated by the magnetic field from a permanent magnet or an electromagnet. The linear sourcing output voltage is set by the supply voltage and varies in proportion to the strength of the magnetic field. Low voltage capability as low as 2.7 Vdc and reduced current consumption of only 6 ma typically at 5 Vdc help make this product energy efficient. The integrated circuitry features low noise output, which makes it unnecessary to use external filtering. It also includes thin film resistors to provide increased temperature stability and accuracy. These linear Hall-effect sensors have an operating temperature range of -40 C to 100 C [-40 F to 212 F], appropriate for commercial, consumer, and industrial environments. VALUE PROPOSITION Designed and manufactured for cost competitiveness All packages can be supplied on tape for automated, lower-cost assembly SS39ET s small footprint takes up less space on the PC board, typically allowing for more components Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range FEATURES AND BENEFITS Miniature and subminiature construction: Designed for compact designs with tight space requirements Energy efficient: Low current consumption of 6 ma at 5 Vdc Easy PC board interface: Single current sourcing output for common electronic circuits Circuit design flexibility: Voltage range of 2.7 Vdc to 6.5 Vdc Low noise output: Virtually eliminates the need for filtering Stable output: Thin film resistors improve accuracy Wide range of environments: Temperature range of -40 C to 100 C [-40 F to 212 F] Application flexibility: Responds to either positive or negative Gauss POTENTIAL APPLICATIONS Industrial: Basic current sensing for motor load monitoring, detection Anti-tampering magnetic field sensor in smart remote utility meters Pump control in heavy-duty equipment and household appliances Simple linear or angular displacement sensing Handlebar/throttle position sensing in e-bikes and scooters Current sensing in appliances Speed adjustment trigger in tools and appliances Magnetic code reading in safes, security and building access control systems Medical: Position sensing in infusion pumps

Table 1. Operating Characteristics (V S = 5.0 V, TA = -40 C to 85 C [-40 F to 185 F], except where noted) Characteristic Condition Min. Typ. Max. Unit Output type linear, sourcing Magnetics type analog Supply voltage 2.7 6.5 Vdc Supply current 25 C [77 F] 6 10 ma Output voltage 1.0 1.4 1.75 mv/gauss Output current V s > 3.0 V 1.0 1.5 ma Null 0 Gauss, 25 C 2.25 2.50 2.75 Vdc Output voltage span 1.05 to (V s - 1.05) 0.95 to (V s - 0.95) Vdc Magnetic range ±650 ±1000 Gauss Sensitivity 25 C 1.0 1.4 1.75 mv/gauss Operating temperature -40 [-40] 100 [212] C [ F] Temperature error Null drift -0.10 0.10 Sensitivity drift 25 C -0.15 0.05 %/ C <25 C -0.04 0.185 Linearity -0.7 % of span Response time 3 µs Table 2. Absolute Maximum Ratings Characteristic Parameter Supply voltage (V s) -0.5 Vdc to 8.0 Vdc Output current 10 ma Storage temperature -55 C to 165 C [-67 F to 329 F] Figure 1. Current Sourcing Output Block Diagram Figure 2. Transfer Characteristics (V S = 5.0 Vdc) NOTICE Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the device necessarily operate at absolute maximum ratings.

Figure 3. Null Shift versus Temperature Figure 4. Sensitivity Shift versus Temperature Figure 5. Typical Frequency Response Figure 6. Supply Current versus Temperature

2, 80 [0. 110] 1, 60 [0. 063] 2,90 [0.114] 3 GND (-) NOMINAL IC CENTER 1 VCC (+) 0,95 [0.037] 1,90 [0.075] 2 OUTPUT 3X 0,50 [0.20] NOMINAL TO IC SENSING SURFACE 0,413 [0.016] 1,20 1,45 [0.047] [0.057] 0,77 [0.030] 0,787 [0.031] N S 0,60 [0.024]

XXX + 0 4,1 1,6 0,64 [0.025] 0,38 14,99 [0.59] 3,0 [0.12] 0,3 0,76 [0.03] HALL ELEMENT CENTER N S XXX + 0 4,1 0,64 [0.025] 0,38 18,669 [0.735] 3,0 [0.12] HALL ELEMENT CENTER 1,6 0,3 0,76 [0.03] N S XXX + 0 4,1 1,6 0,64 [0.025] 0,38 14,99 [0.59] 3,0 [0.12] 0,3 0,76 [0.03] 4 HALL ELEMENT CENTER N S

ADHESIVE TAPE ADHESIVE TAPE 22,3 [0.88] 6,0 [0.23] 9,0 [0.35] 18,0 [0.71] 22,3 [0.88] 6,0 [0.23] 9,0 [0.35] 18,0 [0.71] 6,3 [0.25] 12,7 [0.50] Ø 3,99 6,3 [0.25] 12,7 [0.50] Ø 3,99 0,1 [0.01] 0,96 TYP TO HALL EFFECT [0.38] SENSING SURFACE R 0,25 MAX [0.01] 0,13 MAX FLASH [0.005] 4,4 [0.17] 2,4 [0.09] 4,2 CATALOG LISTING DATE CODE 0,05 [0.002] 10 TYP + - 2X 1,5 0 0,13 MAX GATE VESTAGE [0.005] 3X 0,4 [0.02] N S 4,5 [0.18] 2,4 MAX [0.9] 0,4 MAX [0.02] 8,0 [0.31] 4,0 2,0 [0.08] Ø 1,5 5,8 [0.230] TOP COVER TAPE 0,7 [0.004] 5,5 [0.22] 12,0 [0.47] 2,0 [0.08] 8,0 [0.315] 5,0 [0.20] 4,6 [0.18] Ø 13,0 [0.51] 3X 1,5 Ø 33,0 [1.30] 18,4 [0.72] 12,2 [0.48] 50,0 [1.97] Ø 178,0 [7.01]

WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com/sensing 005850-2-EN February 2012 2012 Honeywell International Inc. All rights reserved.