English. Instruction and operation manual S 530. Leak detector for pneumatic systems

Similar documents
English. Instruction and operation manual S 530. Leak detector for pneumatic systems

EN-ENGLISH INSTRUCTION MANUAL. METPOINT LKD 300 Leak Detector (LD109) For leak detection in pneumatic systems.

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

VISION H. Instruction manual

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Instruction manual EN

100 Ft. LASER DISTANCE METER

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Digital Display DS 52 in wall housing. Order no

Tru Pointe Ultra Ultrasonic Leak Detector

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Model R9100. REED Instruments Instruction Manual. Ultrasonic Leak Detectortor

Laser Distance Sensor Type M Analog-Output

Self-Leveling Five-Beam Laser Pointer Model No Instruction Manual

POWER METER INSTRUCTION MANUAL

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

User manual UV Flash Dry C1

Instructions For Use ENG. LED Magnifier Lamp

CR9986. Please read this manual before use. Dual Alarm CD Clock Radio 5/19/2005, 8:28 AM. Sound for Generations ROBERTS. CR9986 Rev 1.

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

Dual Laser InfraRed (IR) Thermometer

High Temperature InfraRed Thermometer with Laser Pointer

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

MicrOTDR. Optical Fault Locator. User Manual

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Laser Use Registration & Application (L.U.R.)

HV2R ROTARY LASER INSTRUCTION MANUAL

Buzzer Unit. TAN-5000 Series. Operating Manual

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

Users Manual. Visit us at

BIG DISPLAY ALARM CLOCK USER MANUAL

GMH 285 / GMH 285-BNC

Owner s Manual Window Air Conditioner

I/R Thermometer Gun 12:1

AS 500. Instructions for Use. Version 1.0. December

Whisper. Ultrasonic Leak Detector

ELECTRICAL. Stud Detector User Guide

Dry Bath Heating Systems

IMR EX610. Portable Gas Detector. Operation Manual

Customers must fill in and mail the warranty card in order to activate the warranty.

Table of Content

Design Manual Installation Operation Maintenance

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

DP 300 mobile dew point instrument

Quest Power Electric Heat EHS 31 Pro

Infrared Thermometer. Getting Started

RECHARGEABLE CLIPPER LI ION RECHARGEABLE CLIPPER INSTRUCTIONS

Warranty Registration

OKB, OKD, & OKH Series

Owner s Manual Phoenix FireBird

USE AND INSTALLATION HANDBOOK

Laser Radiation and High Voltage/Electrical Shock. Disclaimer and Limitation of Liability. Shipping Damage. Trademarks

La Crosse Technology WT-8002U. Digital Clock with Indoor Temperature

QUICK SCAN COUNTERFEIT DETECTOR

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

i-cube Microplate Incubator E10030

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

E1000 Portable gas detector

Solar Powered Wireless Photobeam Sensors

Instruction Manual. Self-Leveling Laser Level Model No

UV-C Sanitizing System USER MANUAL Purifying Wand (EPLPW)

Preamplifier Power Supply PPS-02 user's guide

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Quest Power Electric Heat EHS 62 Pro

Robotic Vacuum. Operation Manual P4900

Self-Setting Clock Radio

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

User s Manual and Operating Instructions

Portable Air Conditioner

Multi Line Laser Level Model: L203

Instruction Manual JEN0002 / Version 1.0. Peltier Accessory

Infrared Thermometer

ELECTRIC AIR PUMP 130W INSTRUCTION MANUAL SPECIFICATIONS. ozito.com.au WHAT S IN THE BOX. Electric Air Pump. 3 x Inflation Adaptors

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

External Wireless Sounder

SRK-PSE90. Installation Instructions. Stud Rail Kit for PSE90 Manual Wall Bracket. Issue 001

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

IMR IX176 Portable Gas Detector User Manual

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

LIMITED LIFETIME WARRANTY

SOLDERING GUN PLP 100 A1

Operating Manual Hand-held Measuring Device GMH 3690 GL. for Gaseous Oxygen and Temperature with Alarm Function

2. Safety instructions

Laser Use Authorization

User Manual. Humidity-Temperature Chart Recorder. Model RH520

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Transcription:

English Instruction and operation manual S 530 Leak detector for pneumatic systems

Dear Customer, thank you for choosing our product. The operating instructions must be read in full and carefully observed before starting up the device. The manufacturer cannot be held liable for any damage which occurs as a result of non-observance or noncompliance with this manual. Should the device be tampered with in any manner other than a procedure which is described and specified in the manual, the warranty is cancelled and the manufacturer is exempt from liability. The device is destined exclusively for the described application. SUTO offers no guarantee for the suitability for any other purpose. SUTO is also not liable for consequential damage resulting from the delivery, capability or use of this device. 2 S 530

Table of contents 1. Safety instructions...4 2. Application...6 3. Features...6 4. Technical Data...7 4.1 General...7 4.2 Electrical Data...7 4.3 Performance chart...7 5. Dimensional drawing...8 6. Operating...9 6.1 Operating Principle...9 6.2 Operating Procedure...10 6.3 Electrical connection...11 7. Optional extra accessories...12 7.1 Ultrasonic tone generator...12 8. Maintenance...13 9. Disposal or waste...13 10. Warranty...13 S 530 3

1. Safety instructions 1. Safety instructions Please check if this instruction manual accords to the product type. Please observe all notes and instructions indicated in this manual. It contains essential information which have to be observed before and during installation, operation and maintenance. Therefore this instruction manual has to be read carefully by the technician as well as by the responsible user / qualified personnel. This instruction manual has to be available at the operation site of the leak detector at any time. In case of any obscurities or questions, regarding this manual or the product, please contact the manufacturer. WARNING! Compressed air! Any contact with quickly escaping air or bursting parts of the compressed air system can lead to serious injuries or even death! Avoid that persons get hit escaping air or bursting parts of the system. WARNING! Laser pointer! Do not point into the eyes with the laser, it can lead to serious injuries particularly on lens and retina or even blindness! Never look directly in the laser Never point the laser at persons. Never point the laser at smooth and reflective surfaces it can lead to a reflection of the laser. WARNING! Voltage used for supply! Any contact with energized parts of the product, may lead to a electrical shock which can lead to serious injuries or even death! 4 S 530

1. Safety instructions WARNING! Permitted operating parameters! Observe the permitted operating parameters, any operation exceeding this parameters can lead to malfunctions and may lead to damage on the instrument. Do not exceed the permitted operating parameters. Make sure the product is operated in its permitted limitations. Do not exceed or undercut the permitted storage and operation temperature and pressure. The product should be maintained and calibrated frequently, at least annually. General safety instructions It is not allowed to use the product in explosive areas. Please observe the national regulations before/during operation. Remarks It is not allowed to disassemble the product. ATTENTION! Measurement values can be affected by malfunction! The product must be used properly and frequently maintained, otherwise it may lead to wrong measurement values, which can lead to wrong results. Avoid condensation on the leak detector element as this will affect the accuracy enormously. Storage and transportation Make sure that the transportation temperature of the leak detector is between -20 C... 50 C. For transportation it is recommended to use the packaging which comes with the leak detector. Please make sure that the storage temperature of the sensor is between -10 C... 50 C. S 530 5

Avoid direct UV and solar radiation during storage. 1. Safety instructions For the storage the humidity has to be <90%, no condensation. 6 S 530

2. Application 2. Application The S 530 is a leak detector for pneumatic systems. When gases are leaking through tubes and tanks an ultrasonic sound is produced which can be detected by S 530 even from several meter distance. The S 530 transforms these inaudible signals into a frequency which can be easily heard by using the supplied noise isolated headset. In unpressurised systems an ultrasonic tone generator can be used whose sound will leak through small openings. The integrated laser pointer helps to spot the leak from distance. The S 530 leak detector is not developed to be used in explosive areas. For the use in explosive areas please contact the manufacturer. The S 530 leak detector is mainly used in compressed air systems in industrial environment. 3. Features Leak detection in compressed air, refrigerants, simple of any gas. Insulation test of doors and windows. Detection of partial electrical discharges causing damages on insulations. Can be used in noisy environments. Included laser pointer helps to locate the leak. Included display, showing the level of the leak. S 530 7

4. Technical Data 4. Technical Data 4.1 General Principle of measurement Ultrasonic leak detection Measuring medium Plugs Operating frequency Air, refrigerants and any gases Plug 1: 4 pole connector shared by headphone and battery charger Plug 2: 3.5 mm stereo phone jack for sensor or sensor cable connection. 40 khz ± 2 khz Operating temperature 0 C... 40 C Operating time Charging temperature 10 C... 45 C Charging time Material of the detector Dimensions Display Laser pointer Weight 4.2 Electrical Data About 6 hours without Laser pointer on About 4 hours with Laser pointer on Around 1.5 hours PC + ABS See dimensional drawing on the next page 3 colour black-mask LCD, 10 level 640... 660 nm wavelength 0.4.0.5 mw output power 2.5 kg (full set) Power supply Internal NiMH rechargeable battery 4.3 Performance chart The table shows the detection distance of varicose hole diameters at different pressures (lab environment). Pressure / diameter 0.1 mm 0.2 mm 0.5 mm 0.5 bar 5.0 bar 2m 2m 10m 8m 14m 18m 8 S 530

5. Dimensional drawing 5. Dimensional drawing S 530 9

6. Operating 6. Operating Please make sure that all components listed below are included in your package. Qty Description 1 S 530 leak detector 1 Sensor unit 1 Noise isolated head set 1 Focus tube and focus tip 1 Cable to detach sound probe from instrument 1 Battery charger 1 Transport case Remark The sensor unit can be unplugged from the main instrument by pulling the unit out of the holder. A separate coiled extension cable is used to connect the sensor to the main unit. For this have a look at the picture above. 6.1 Operating Principle Air leaks produce wide-band ultrasounds in the range of 20... 80 khz. The higher the frequency the more energy it contains. But higher frequencies can not be transported in air that far. Thats why the leak detector operates at a centre frequency of 40 khz which compromises an optimum between energy and distance. Frequencies below and above are cut in order to minimize the noise level. 10 S 530

6. Operating 6.2 Operating Procedure The following steps explain the procedure of an appropriate use. 1. Press the Power button. 2. The Display of the S 530 look like the picture on the left side. The laser pointer is off. the Display will show you: the battery level. the segments green till red. User can change the sensitivity with the wheel. 3. To activate the laser, please S 530 11

6. Operating press the button which is shown on the left side. 4. Point with the laser at a assumed leak. The display will show the level of the leak. 6.3 Electrical connection 5. To find the exact location of the leak screw the focus tube and the focus tip on the sensor. 6. Scan with the focus tip the roughly location till the exact location is found. 7. For difficult attainable location you can use the separate coiled extension cable. Either the headphone or the charger can be connected to S 530 at a time. Remark If the instrument has not been used for more than 2 months, the battery might be over discharged. Connect the battery charger an wait about 2-3 minutes until the display can show you the actual battery status. 12 S 530

7. Optional extra accessories 7. Optional extra accessories 7.1 Ultrasonic tone generator The Ultrasonic tone generator is an optional extra accessory for the S 530. It generate an ultrasonic tone which can be detected by the S 530. Thats why a leak detection in a system without overpressure is possible. Specification Frequency: 40 khz +/- 10% Automatically shut-down after 10 min +/- 20% Power supply internal: E-Block 6LR61 9V For example Leak test at a tank: If an US tone generator is inside of a tank the ultrasonic which is produced by the generator can flow through leaks and detected by the S 530. S 530 13

8. Maintenance 8. Maintenance To clean the sensor and its accessories it is recommended to use moist cloth only. ATTENTION! Do not use isopropyl alcohol to clean the sensor and its accessories! 9. Disposal or waste Electronic devices are recyclable material and do not belong in the household waste. The detector, the accessories and its packings must be disposed according to your local statutory requirements. The dispose can also be carried by the manufacturer of the product, for this please contact the manufacturer. 10. Warranty SUTO provides a warranty for this product of 24 months covering the material and workmanship under the stated operating conditions from the date of delivery. Please report any findings immediately and within the warranty time. If faults occurring during the warranty time SUTO will repair or replace the defective unit, without charge for labour and material costs but there is a charge for other service such as transport and packing costs. Excluded from this warranty is: Damage caused by: Improper use and non-adherence to the instruction manual. Use of unsuitable accessories. External influences (e.g. damage caused by vibration, damage during transportation, excess heat or moisture). The warranty is cancelled: If the user opens the measurement instrument without a direct request written in this instruction manual. If repairs or modifications are undertaken by third parties or unauthorised persons. 14 S 530

10. Warranty If the serial number has been changed, damaged or removed. Other claims, especially those for damage occurring outside the instrument are not included unless responsibility is legally binding. Warranty repairs do not extend the period of warranty. ATTENTION! Batteries have a reduced warranty time of 12 month. S 530 15

SUTO itec GmbH SUTO itec Co., Ltd. Werkstr. 2 Room 10, 6/F, Block B, Cambridge Plaza 79426 Buggingen 188 San Wan Road, Sheung Shui, N.T. Germany Hong Kong Tel: +49 (0) 7631 936889-0 Tel: +86 (0) 755 8619 3164 Fax: +49 (0) 7631 936889-19 Fax: +86 (0) 755 8619 3165 Email: sales@suto-itec.com Email: sales@suto-itec.asia Website: http://www.suto-itec.com Website: http://www.suto-itec.com All rights reserved Modifications and errors reserved. S530_im_en_2016-2