Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Similar documents
ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_v0707_Pre.doc 1/50

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

ME 3011C / Alarm Indication / Quick Reference Guide

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_r07 at 1/68

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

Signal Processing System ME30 infobox

DRAFT 20 October 2014

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Annunciator Unit SACO 16 D1. Product Guide

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Annunciator unit. Application

System 9000TS Sequence of Events Recorder

AO Annunciator Module

Series 725 Programmable Alarm Annunciator

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

Return loss measurement of fiber optic components

M2500 Engine Controller Installation Manual

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

X11CA COMPUTER ANNUNCIATORS

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Operation Manual Part-No

Carbon Monoxide Transmitter

Model A2100 Series Annunciator

Analog Annunciator Unit SACO 16 A3. Product Guide

AN-3100D Annunciator

M1000 Alarm Annunciator

Fire control panels FC726 FC726-XA

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Mosaic System-Control Room Technology. Illuminated Pushbutton and Pushbutton Switch LT 1879 / LT 2479 LS 1879 / LS 2479

Model A1700 Series Annunciator

RS485 MODBUS Module 8AI

System 57. An advanced World of intelligent gas detection system management

Complex alarming made simple

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Installation Instructions

On the job around the clock 24/7: Fire detection systems

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Parameterisable compact fault annunciator with permanent display

Panel Mounted Fault Annunciator Series

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Accuracy counts! Sensors with analog output

System 57. An advanced world of intelligent gas detection system management

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

PolyGard 2-channel Gas Controller MGC-03

Universal fault annunciator for panel mounting

Multi-Gas-Controller MGC2

KNX The worldwide STANDARD for home and building control. KNX Association International

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Annuciator Logic Controllers

STT 3000 Series STT250 /150 Surge Protection Device Specifications

KNX The worldwide STANDARD for home and building control. KNX Association International

Pre-programmed room controller with communication

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

Temperature Controllers

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Remote alarm indicator and test combination MK2430

Panel Mounted Fault Annunciator Series

Two-Channel Gas Controller

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Window facia fault annunciators

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

FC722 Fire control panel

Process & TeMPerATUre UniversAl input DigiTAl MeTers

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Fire control panels FC360

SIL725 Safety Annunciator

Technical Manual. Level Alarm Unit CARLA & WIDS

IntesisBox BACnet/IP Server - Notifier ID3000 series

FC724 Fire control panel

FC724 Fire control panel

/8 DIN Level Indicator

CLEANROOM MONITOR CR3A Network - Installation Instructions

Labkotec Ice Detector

FC722 Fire control panel

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

MO n : 12JMC rév A

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

21-light Remote Annunciator. Owner s Manual

HRX Technical Manual. Version 1.2

FC723 Fire control panel

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Intelligent addressable fire alarm control panel

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

CTT8 TEMPERATURE MONITOR DEVICE

XLH210: controller for gas leak detectors

YOUR PARTNER IN FIRE & GAS DETECTION

Transcription:

Standard Devices Electronic Alarm Indication Systems ME 3011b

Before connecting and powering this device, please read carefully the manual, and refer to it whenever you have any doubts. This brochure is subject to changes without previous advice.

Table of Contents Contents Page Operation Principle 4 Technical Data 5 Modularity and Arrangements 6 Dimensions 7 Front Display Engraving Signaling Sequences 9 Special Options 10 e.tool ME 3011-view Visualization via Serial Interface 11 Electronic Alarm Indication Systems ME 3011b 3

Operation Principles The alarm annunciators have the main function of safely signaling critical status of installations, aiming at their integrity. They signal acoustically and optically equipment alarms in a standardized way, within the highest ergonomic and cognitive possible standard. It is recommended, in general, to carry out the direct connection of electric field alarm signals to the annunciator, preventing loops through digital automation and control systems. Thus, the necessary operating safety level is achieved. The maximum alarm signal cable length is 600 m (unshielded) or 1000 m (shielded). These maximum values may be strongly reduced in areas of very high electromagnetic fields, for example in the case of open air cable trays within substations. It is, also, of paramount importance to place the signal cables in trays carrying cables with homogeneous voltages. Placing high and low voltage cables in conjunction within the same cable tray may cause serious annunciator malfunctions or even hardware damages. The ME 3011b annunciator, the new member of Mauell annunciator family, keeps one of the most important characteristics of ME 3010b series, which is the modularity of the alarm windows. The processing fundament of the alarm signs is now carried out through last generation micro controllers, with high performance RISC architecture. So, ME 3011b annunciator incorporates all the advantages of a micro processed system, such as configuration of the annunciators main functions through the front keyboard, or also via configuration software for download. This way, the ME 3011b annunciator provides all conventional functions of alarm announcing together with new and advanced communication function in local network and event recording, among others. These functions will be described in details throughout the manual. Alarm Annunciator ME 3011b 4 Electronic Alarm Indication Systems ME 3011b

Technical Data 1 Supply Voltage 1.1 PS-05 Power Supply Standard 24 Vdc ± 20 % 1.2 PS-02 Power Supply Input 19 to 264 Vdc and/or (Option) 90 to 264 Vac Output 24 Vdc/0.75 A 1.3 Special Option PSFD Power Supply Fault Detector for Vdc and/or Vac Note: All power supplies are integrated into the annunciator 2 Inputs 2.1 Alarm Inputs 4 up to 252 Isolation Optical couplers Input Voltages 24, 4, 60, 110/125 Vdc and 110/127, 220 Vac, ± 20 % Input Current 3 ma (typical) Input Filter lower value = 5 ms, programmable in steps of 2.5 ms 2.2 External Push-Button Station 24 Vdc Isolation Opto couplers Functions Sound Acknowledge (HA) Light Acknowledge (LA) Reset (RE) Light Test / Function Test Sleep Mode (SLM) Keyboard OFF (KBOFF) 2.3 Synchronism with GPS and/or Flashing 24 Vdc Isolation Opto couplers 3 Outputs 3.1 Relays 3 freely programmable relays for various functions, e.g., external buzzer, voltage fault, alarm group, etc 3.2 Sound Indication 90 db / 10 cm, 4 khz 3.3 Repeat relays 1 contact for each alarm point, Note: Field voltages over 125 Vdc or Vac for resistive load. Maximale switching voltage 125 Vdc/250 Vac 4 Interfaces 4.1 Communication Standard RS232TTL bi-directional 4.2 Communication RS232C RS232C bi-directional Option Baud rate: 9600, n,, 1 Protocol: Modbus RTU (Slave) or Modbus RTU (Slave)+TS 4.3 Communication RS 45 bi-directional serial communication (configurable) Baud rate: 110 to 19200 Parity: even, odd or none Stop bit: 1 or 2 Protocol: Modbus RTU (Slave) Event Register (Option) 5.1 Events 1000, with time stemp 5.2 Resolution 1 ms, samples 2.5 ms 5.3 Interfaces Rs232C or RS45 5.4 Protocols Mauell or Modbus RTU (slave) -TS 6 Visualization 6.1 Light Indication Back light Led Special Option Back light available in red, yellow, green white and blue colors 5 mm visible red, yellow and green color leds More than 1 color per annunciator 6.2 Flashing frequency Fast: approx. 1.2 Hz Slow: approx. 0.4 Hz 6.3 Windows Dimension 24 mm x 4 mm Back light White translucent modules Led Gray RAL 7032 polycarbonate modules 7 General 7.1 Alarm sequence ISA 1, 1A, 1B, 2A, 2C, 4A; 4AR others on request 7.2 Environment Operation temperature -20 to 55 C Storage temperature -20 to 0 C Relative Humidity 0 to 95 %, without condensation 7.3 Protection class Front IP41 Enclosure IP30 7.4 Isolation 2 kv, 60Hz, 1 min. in compliance with IEC 255.4 7.5 Terminals Terminal connectors (removable) for cables up to 2.5 mm 2 Electronic Alarm Indication Systems ME 3011b 5

Modularity and Arrangements The minimum configuration possible for the annunciator is a central module with 4 alarm points, and dimension of 2v x 4h or 4v x 2h (see shaded portion on lower right corner of diagram below). Expansion modules can be added to this central unit, with 4 or alarm points each, always in 2v x2h or 2v x 4h modularity basis. So the subsequent configurations are, 12, 16, 20, 24, 2 points and so on, up to a maximum of 252 alarm points. The module arrangement follows the diagram below. Enclosure arrangement Nr. of Points Arrangement 4 2v x 4h 2v x 4h 2v x 6h 6v x 2h 12 4v x 4h 2v x h 16 10v x 2h 2v x 10h 12v x 2h 20 6v x 4h 4v x 6h 2v x 12h 24 14v x 2h 2v x 14h 16v x 2h 2 v x 4h 4v x h 2v x 16h 32 1v x 2h 6v x 6h Nr. of Points Arrangement 20v x 2h 36 10v x 4h 4v x 10h 40 22v x 2h 12v x 4h 44 v x 6h 6v x h 4v x 12h 4 26v x 2h 2v x 2h 52 14v x 4h 4v x 14h 56 10v x 6h 6v x 10h 16v x 4h 60 v x h 4v x 16h 6 1v x 4h 6v x 12h 76 20v x 4h 10v x h Nr. of Points Arrangement 4 22v x 4h 24v x 4h 92 12v x h v x 12h 6v x 16h 10 14v x h 116 10v x 12h 124 16v x h v x 16h 140 1v x h 12v x 12h 156 20v x h 10v x 16h 164 14v x 12h 172 22v x h 1 24v x h 16v x 12h 12v x 16h 212 1v x 12h 220 14v x 16h Nr. of Points Arrangement 236 20v x 12h 252 16v x 16h 6 Electronic Alarm Indication Systems ME 3011b

Dimensions 9.5 L = h x 4 + 24.5 A = v x 24 + 24.5 RUN FA ME 3011 T 114 Cutout Table (height v x width h) mm x mm h (x) Points 2 4 6 10 12 14 16 2-52 x 196-52 x 3-52 x 50-52 x 772 4 100 x 100 100 x 196 100 x 292 100 x 3 100 x 44 100 x 50 100 x 676 100 x 772 6 14 x 100 14 x 196 14 x 292 14 x 3-14 x 50-14 x 772 196 x 100 196 x 196 196 x 292 196 x 3-196 x 50-196 x 772 v 10 244 x 100 244 x 196 244 x 292 244 x 3-244 x 50-244 x 772 (y) 12 292 x 100 292 x 196-292 x 3-292 x 50-292 x 772 14 340 x 100 340 x 196-340 x 3-340 x 50-340 x 772 16 3 x 100 3 x 196-3 x 3-3 x 50-3 x 772 1 436 x 100 436 x 196-436 x 3-436 x 50 - - 20 44 x 100 44 x 196-44 x 3-44 x 50 - - 22-532 x 196-532 x 3-532 x 50 - - 24-50 x 196-50 x 3 - - - - Electronic Alarm Indication Systems ME 3011b 7

Front Display Inscriptions 1 Low Relief Engraving 1.1 Back Light Display LB 24 x 4 White Translucent - Code : 3.53.002 Character height = 3 mm Maximum number of characters per line = 19 Maximum number of lines = 4 24 23 ABCM DRFTG MDMCD ABCM 4 5 5 5 24 23 ABCDEFGHJKLMNOPRSTU ABCDEFGHJKLMMMP ABCDEFGHJKLMM 6 6 5.5 47 4 47 4 1.2 LED Display MK 24 x 4 - RAL 7032 color - Code : 3.52.003 Character height = 3 mm Maximum number of characters per line = 15 Maximum number of lines = 4 24 23.5 ABCDEFGHIJKLMNOP ABCDEFHJKLMM ABCDEFGHJKLMNOP ABCDEFG 4 5 5 5 24 23.5 ABCDEFHJKLMMMP ABCDEFGHJKLMM ABCDEFHJKLMMMP 6 6 6 47 4 47 4 Electronic Alarm Indication Systems ME 3011b

Signaling Sequences The ME 3011b can be configured in order to comply with 16 signaling sequences. Among them the most important are the following: ISA-RP 1.1/(ISA-S1.1) ISA-1/(A), ISA-1A/(A-5), ISA-1B/(A-4), ISA-2A/(R-), ISA-2C/(M), ISA-4A/(F1A), ISA-4AR/(F1M) etc. Other sequences can be implemented on request. ALARM SEQUENCE REF ISA ALARM NORMAL ABNORMAL ACKNOWLEDGE BACK TO BACK TO ACKNOWLEDGE RESET SOUND LIGHT NORMAL NORMAL BEFORE SOUND LIGHT ACKNOWLEDGE ISA 1 (A) ISA 1A (A-5) ISA 1B (A-4) LIGHT SOUND LIGHT SOUND LIGHT SOUND ISA 2A LIGHT F F S F F S (R-) ISA 2C (M)default SOUND LIGHT SOUND PRIMARY SIGNAL SEQUENCE (1 st Event) BACK TO NORMAL REF ALARM NORMAL ABNORMAL ACKNOWLEDGE BACK TO NORMAL BEFORE ACKNOWLEDGE RESET ISA ACKNOWLEDGE INITIAL SUBSEQ INITIAL SUBSEQ INITIAL SUBSEQ INITIAL SUBSEQ INITIAL SUBSEQ ISA 4A Light Sound ISA 4R Light Sound LEGEND F = Fast LED Off Siren = Off LED On S = Slow LED intermittent Siren On Electronic Alarm Indication Systems ME 3011b 9

Special Options 1 Light Display with more than one color In this case, the quantity and position for each color must be requested by the customer. For LED Display up to 3 colors in red, yellow or green For Back Light Display up to 5 colors in red, yellow, green, white or blue 1.1 Back Light Socket In this option, the SMD Back Light LED is socket mounted and plugged on the annunciators PCB. It allows to change the indicating light color for the individual alarm points. The socket Back Light LED must be specified at ordering the annunciator, as a special factory option. 2 - ES-00 Empty Slot If the total alarm points amount of the annunciator enclosure is higher than demanded, it is possible to provide empty slots, each with alarm points. The position of the empty slot is defined due to the physical adress of each module, and must attent to the tables below. The empty slot is always the last, following the pointer direction. The empty slots for Back Light are delivered with the translucent Back Light Display and the LED Version with the RAL 7032 Display. 12 24 1 4 3 2 1 24v x 4h Empty Slot 12 24 2 1 7 6 5 4 3 2 1 24v x h Empty Slot 11 22 92 ES-00 11 22 10 1 ES-00 10 20 4 10 20 172 164 9 1 76 9 1 14 156 16 6 16 140 132 7 14 60 7 14 116 124 6 12 52 6 12 10 100 5 10 44 5 10 4 92 4 36 4 76 6 3 6 2 3 6 52 60 2 4 20 2 4 44 36 1 2 12 4 CM-03 1 2 20 2 12 4 CM-03 10 Electronic Alarm Indication Systems ME 3011b

e.tool ME 3011-view Visualization via Serial Interface The e.tool ME3011-view is a ME3011b dedicated software that allows the visualization of the event registers from up to 10 annunciators in one NET. For more information, please consult our Sales Department at info@mauell.com RS232C (option) with 5, 10 or 15 m cables event recording with 1,0 ms resolution with samples each 2,5 ms enhanced maintenance oriented functions advanced communication protocols TCP/IP interface up to 10 annunciators in one NET Electronic Alarm Indication Systems ME 3011b 11

Representatives Germany Helmut Mauell GmbH Am Rosenhügel 1 7 D-42553 Velbert Tel.: +49 (0)20 53 / 1 30 Fax.: +49 (0)20 53 / 1 36 53 Internet: www.mauell.com E-Mail: info@mauell.com For an up-to-date list of all our representatives and branch offices, please visit our homepage: www.mauell.com Representatives and Branch Offices All Over The World: Abu Dhabi U.A.E. Argentina Austria Belgium Brazil Czech Republic Denmark Finland France Great Britain Hungary Iran Korea Kuwait Netherlands Norway Poland Singapore Spain Sweden Switzerland Turkey USA 05.3011.03E07