Model 5100A, 5200A, and 5100ALBV Owner s Manual

Similar documents
AGF Manufacturing Inc. Model Owner s Manual INST-5400A_V /15

Exit Stopper. STI-6400 Series

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Exit Stopper. STI-6400 Series

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

WM3000 WIRELESS MODULES

Addendum for STI-6406 with Dual Access Control

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Installation Instructions for W2H Series Signals

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

Duct and Rough Service Carbon Monoxide Sensor

AGF Manufacturing Inc. Inspector's Test and Drain Valves for Residential and Commercial Wet Fire Sprinkler Systems

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

1U ULTRA Compact System

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Follett Performance Plus

Water Detection Controllers

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Guidelines: Proper Installation of Outdoor SpectrAlert Advance Audible Visible Devices. White Paper February 2014

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

Pioneer-R16 Gas Monitor Operator s Manual

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

AGF Manufacturing Inc.

Installation Guide for models:

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Installation Guide for models:

INSTALLATION AND MAINTENANCE

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

PO Box 827 Hawley, MN (218) Fax (218)

CORNELL Emergency Response Systems

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

STEAMPRO. Steam Generator Troubleshooting and Service Guide

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Booster Power Supply Manual

Addressable Detectors & Bases

21-light Remote Annunciator. Owner s Manual

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Functional Performance Test

Pump-Up Controller MODEL 4062

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

Installation Instructions

Smart Temp. ApolloP/n Installation Manual. Version 1.0

GAS SUPRESSION CONTROL PANEL:

Electro-Sentry. Users Manual

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Analog Room Pressure Monitor RPC Series

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

EVO192 v3.0 Fire and Burglary What s New

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

System 800 Addressable Fire Detection & Alarm System

Pump-Down Controller MODEL 4052

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

STA16 SELECTRONIC ALARM ANNUNCIATORS DESIGN, INSTALLATION AND OPERATING MANUAL STA16

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

Installation Instructions

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

Remote Chexit Module (RCM) System. General Information

WIRING DIAGRAM AND INSTRUCTIONS

SAFETY INFORMATION AND WARNINGS

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

Wiring Instructions (01-09)

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

DE5300 Delayed Egress System. General Information

aquilar - leak detection solutions

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Water Leak Detector. Installation and Troubleshooting. Overview

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Fire Control/Communicator

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Series. Access Power Controllers. Installation Guide

Specification/ Data Sheet

D-Tect 2 GJD300 Quad PIR Movement Detector

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

TrueAlert Multi-Candela Notification Appliances

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

Notification Appliance Circuit Module

Transcription:

AGF Manufacturing Inc. Model 5100A, 5200A, and 5100ALBV Owner s Manual INST-COLLECTanDRAIN_V001.9 Model 5100ALBV Model 5100A Model 5200A

Model 5100A, 5200A and 5100ALBV Owner s Manual COLLECTa ndrain Anti-Trip Auxiliary Drains for Dry Pipe and Pre-Action Fire Sprinkler Systems Condensate Nipple Supply Side (Upper) Ball Valve Anti-Trip Plate Water Detection Alarm Anti-Tamper Lock Test Button (On Back Side) Model 5100A Drain Side (Lower) Ball Valve Plug Table of Contents Installation Instructions Model 5100A/5200A... 3 Model 5100ALBV...3-4 Operation Instructions Model 5100A/5200A... 4 Model 5100ALBV...5-7 WARNING: The COLLECTa ndrain Anti-Trip Plate is designed to make sure that the auxiliary drain is operated in the proper manner and correct sequence as per NPFA guidelines to avoid accidental tripping, improper maintenance, and acts of vandalism. The M5100ALBV Water Detection Alarm detects the presence of water in the COLLECTa ndrain and alerts personnel when maintenance is needed. COLLECTa ndrain Model 5100A and 5200A are not designed to prevent freezing or automatically drain condensation from the system. Failure to drain condensation from system may result in catastrophic system failure due to freezing. System must be maintained per NFPA 25 4.6, 4.6A and 4.1. 2

Model 5100A/5200A Installation Instructions Retro-fitting into an Existing System 1. Isolate branch line or zone where the COLLECTanDRAIN is to be installed. 2. Relieve air pressure from the branch line. Remove existing auxiliary drain/condensation collection assembly. 4. Install the COLLECTanDRAIN by attaching the supply valve (upper) to the sprinkler system pipe in accordance with NFPA 13 (2013 edition) 8.16.2.5 and 8.16.2.5.3 with regards to low-point drains (auxiliary drains). 5. Confirm that the supply valve (upper) is in the open position and ready to collect condensation, the drain valve (lower) is closed, and the plug is tight. 6. Return system back to normal operating conditions. Installation into a New System 1. Install the COLLECTanDRAIN by attaching the supply valve (upper) to the sprinkler system pipe in accordance with NFPA 13 (2013 edition) 8.16.2.5 and 8.16.2.5.3 with regards to low-point drains (auxiliary drains). 2. Confirm that the supply valve (upper) is in the open position and ready to collect condensation, the drain valve (lower) is closed, and the plug is tight. Activate system for normal operating conditions. Note: The presence of even a small amount of water in the COLLECTa ndrain Model 5100A will activate the Model 5100ALBV Alarm s visual and audible alerts signaling the need for attention. The COLLECTa ndrain must be drained completely to silence the alarm. Please call 610-240-4900 for instructions on how to locally silence the audible alert if directly wired to a Fire Control Panel or BMS. Model 5100A/5200A Operating Instructions To Collect Condensate per NFPA 25 (2011 edition) A.14.4.2, 14.4.2* 1. Close the drain valve (lower) by making sure the valve handle is perpendicular to the collection assembly. 2. Apply Teflon tape to the plug and make sure the plug is tightly threaded into the bottom of the drain valve. Slide the Anti-Trip Plate to its lowest position. 4. Open the supply valve (upper) by making sure the valve handle is in line with the collection assembly. 5. If equipped, install the anti-tamper lock. AGF Manufacturing Inc. Phone: 610-240-4900 Fax: 610-240-4906 www.agfmanufacturing.com 3

Model 5100A, 5200A and 5100ALBV Owner s Manual To Drain Condensate per NFPA 25 (2011 edition) A.14.4.2, 14.4.2* 1. Close the supply valve (upper) and remove plug. 2. Slide the Anti-Trip Plate to its highest position and open the drain valve (lower) to drain the accumulated water. Once the water has been drained, close the drain valve (lower) and slide the Anti-Trip Plate to its lowest position. 4. Open the supply valve (upper) and allow time for any remaining water in the system to accumulate. Repeat steps 1-3 until all of the water has been drained from the system. 5. Once all water has been drained apply new Teflon tape to the plug and make sure it is tightly threaded into the bottom of the drain valve. 6. Close the drain valve (lower) and slide the Anti-Trip plate down into its lowest possible position. 7. 8. Open the supply valve (upper). If equipped, install the anti-tamper lock. Model 5100ALBV Installation Instructions The alarm module operates on the principle of conductivity. The alarm contains a probe that is attached to the piping system. When condensate collects in the piping and reaches the probe, the electrical circuit is completed and the unit sounds an audible alarm, flashes a visual red LED, and changes the state of the output relay. The module will reset itself when the condensate is completely drained. Retro-fitting onto an Existing Auxiliary Drain 1. Isolate the auxiliary drain that the COLLECTanDRAIN Model 5100ALBV is to be installed on. 2. Remove the plug and open the drain valve (lower) to empty the condensate from the auxiliary drain and relieve the air pressure. 4. 5. Remove the existing drain valve (lower) from the auxiliary drain. Apply PTFE tape or appropriate sealant to the Model 5100ALBV. Install the Model 5100ALBV by threading the valve into the appropriate fitting. 6. Confirm that the drain valve (lower) is closed and the plug is tight. Open the supply valve (upper) and the auxiliary drain is ready to collect condensate. 7. Return system back to normal operating conditions. 8. See Page 5-7 for Wiring Instructions. 4

Model 5100ALBV Operating Instructions Power is supplied to the Model 5100ALBV by a 9V Battery (default) or by installing a 12-24VDC external hard wire (See Page 6). The 5100ALBV can draw up to 100mA during operation. Ensure the power supply is sized appropriately for this and any other loads on the same circuit. Battery Operation: 1. Remove four screws on the alarm box and take off the cover. 2. For battery operation, check to make sure the Voltage Jumper is on the front two pins as shown in Image 1 (Fig. A). TEMPERATURE +V -V COM N.O. N.C. VOLTAGE Image 1 (Fig. A) Install a 9V battery as shown in Image 2. Note: When the battery begins to run low the alarm will chirp and flash a yellow LED. 4. Place 9V battery under the circuit board as shown in Image 5. Install cover with the four screws. Image 2 Image 3 AGF Manufacturing Inc. Phone: 610-240-4900 Fax: 610-240-4906 www.agfmanufacturing.com 5

Model 5100A, 5200A and 5100ALBV Owner s Manual External Hardwire Operation: 1. Remove four screws on the alarm box and take off the cover. 2. For external power operation, place the Voltage Jumper on the rear two pins as shown in Image 4 (Fig. B). VOLTAGE TEMPERATURE +V -V COM N.O. N.C. Image 4 (Fig. B) While supporting the bottom of the alarm enclosure, remove the knockout using a slotted screwdriver and a hammer (Place a clean rag underneath the knockout to prevent debris from falling onto the circuit board). 4. Install ½, watertight conduit fitting or cord grip into the knockout opening and run the external power source into the alarm housing as shown in Image 5. 5. Connect external power source to V+ and V- terminals ash shown in Image 6 (Fig. B). Ensure DC is from a clean power supply and not fullwave rectified without a capacitor. 6. Install cover with the four screws. Image 5 Image 6 Temperature Sensing Function When the Temperature Sensing Function is enabled and water is present in the auxiliary drain the Model 5100ALBV will not activate the audible and visual alerts if the ambient temperature is above 45 F. When water is present and the ambient temperature falls below 45 F, the Model 5100ALBV will activate the audible and visual alerts. The Temperature Sensing Function helps extend battery life and eliminates unwanted alarm conditions when the threat of freezing is not present. By default the Temperature Sensing Function is enabled when shipped, meaning the alarm senses water only when the temperature is under 45 F. See page 7 to disengage Temperature Sensing Function. 6

To Disengage the Temperature Sensing Function: 1. Remove four screws on the alarm box and take off the cover. 2. Remove Temperature Jumper from left/center pins and reinstall on right/center pins as shown in Image 7 (Fig. C). TEMPERATURE +V -V COM (Fig. C) N.O. N.C. Install cover with the four screws. VOLTAGE Note: If the Temperature Jumper only utilizes two pins call for instructions on how to engage/disengage the Temperature Sensing Function. Remote Notification Function NOTE: Image 7 Left/Center pins covered (Temp -): Alarm functions at < 45º F (engaged) Right/Center pins covered (Temp +): Alarm functions at all times (disengaged) The Model 5100ALBV Water Detection Alarm also features a Remote Notification Function. This function allows you to connect the unit directly to the Fire Control Panel or BSM so when water is detected in the auxiliary drain you will be notified remotely. Remote Operation Setup: 1. Remove four screws on the alarm box and take off the cover. 2. Connect wiring to the Common Terminal and either the N.O. or N.C. terminal as shown in Image 8 (Fig. D). Contact is rated for 2.0A @ 30VDC. TEMPERATURE +V -V COM TERMINALS (Fig. D) N.O. N.C. Install cover with the four screws. VOLTAGE Image 8 Note: Please call for instructions on how to locally silence the audible alert if directly wired to a Fire Control Panel or BMS. Thank You For Using AGF Products! AGF Manufacturing Inc. Phone: 610-240-4900 Fax: 610-240-4906 www.agfmanufacturing.com 7

Auxiliary Drain Freeze Protection The Model 5400A goes beyond the prevention features of the Model 5100A and 5200A by providing a temperature controlled environment to deter system failures due to freezing condensation. The heated and insulated cabinet contains an auxiliary drain with a float switch to monitor condensation levels. When condensation reaches a level where maintenance is needed the float switch activates an audible alarm and an LED warning light. The Model 5400A also features Fire Control Panel notification capabilities. Visit www.collectandrain.com for more information. AGF Manufacturing Inc. 100 Quaker Lane Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.agfmanufacturing.com