Incubating Shaker with Cooling

Similar documents
i-cube Microplate Incubator E10030

Bacti-cinerator Sterilizer

Dry Bath Heating Systems

TTT Digital Incubator

MD-MINI Dry Bath. Instruction Manual

Operation Manual. (Version 1.5.1)

CR-1730R User s Manual

TS-100C. Thermo-Shaker with cooling for microtubes and PCR plates. Operating Manual Certificate. Medical Biological Research & Technologies

INSTRUCTIONS MANUAL. 1.8L Electric Kettle with Multi-Temp Feature SK-1800R (Red) SK-1800SS (Stainless Steel)

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

Hotplates, Magnetic Stirrers and Stirring Hotplates

Note To The User: This product has updated features not yet mentioned in the product manual.

Contents. 7 Notices 21 Electromagnetic fields (EMF) 21 Recycling Important 4

Instruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath

ES-20 Orbital Shaker-Incubator

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

Soldering Station INSTRUCTION MANUAL

MS Mini Incubator MO-MINI. Incubator. Specification. Ordering Information. Accessories

Digital 7 Square Plate Magnetic Stirrer

Thermo Scientific iems Incubator/Shaker HT User Manual

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge

User Manual. Rooster series. This Manual applies to: Drying ovens and sterilizers. Rooster Series. Models : Rooster 30, 55, 80, 110, 140, 210 and 230.

Corning LSE Benchtop Shaking Incubator

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

JURAGON Pro USER MANUAL

PastaMazing POWERED PASTA MACHINE MODEL# GMP500 USER MANUAL

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Techne Dri-Block range. Premium products at affordable prices. Adjustable safety cut-out. 230V and 115V variants. New 5-digit LED display

Micro-Computer Induction Cooktop SR-1885SS

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Sunleaves Air Conditioner

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Induction Cooktop Product Guide (IC200B)

15,000 BTU Portable Air Conditioner

Manual Page 1 of 8. Manual. Laboratory autoclave

Reacti-Therm I and III Heating/Stirring Modules

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

REFRIGERATED BATH CIRCULATOR. Instruction Manual. Covers model : LRBC-13C / LRBC-22C. Please read this manual carefully before using the instrument

incubator, the best in its class

Revolutionary Science RS-IF-202

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Electrical Fireplace Stove with Heater

Digital Heat Block User Manual

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

Product waste disposal - Protection of the environment:

Operation Manual. VWR Vacuum Ovens. (Version 2.0.0) VWR Vacuum Oven , , , ,

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

A3G Green Rotary Laser SPECIAL EDITION INSTRUCTION MANUAL

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

Low Speed Centrifuge. Model XC-2415 Model XC-2450 Operating Manual

MODEL NO: MC02 BATCH NO: PR3547

Incubators THE BENCHTOP EQUIPMENT HYGIENE SOLUTION

User Manual. TN6900 H&E Slide Stainer. Read Prior to Operation! Always keep this manual near the unit! WP

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Toaster Oven + Instruction Manual. Model TO001 CONTENTS. Important Safeguards 1. Know Your Toaster Oven 4. Using Your Toaster Oven 6

ELECTRIC STEW POT MODEL: ESP-E3050C(WH) ESP-E4050C(WH) Owner s Manual. Please read this manual carefully before operating your set.

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

BD Viper Lysing Heater Manual (for BD Viper System)

Black Body Calibration Source User Manual

Incubators. with BioCote antimicrobial protection

Digital incubating/ refrigerating benchtop shakers

MyGel Mini. Operating Manual Version 1.0. a division of. Electrophoresis System

WSK300 Multifunction Wall Control

Reacti-Therm I and III Heating Modules

Dry Block Heaters. Dry Block Heaters. 2 Block Dry Block Heaters with Lid.

INSTRUCTION MANUAL. LOW SPEED CENTRIFUGE ScanSpeed MiniVac And ScanSpeed MaxiVac. Revision : 01 Date : Cat. No. :

Centrifuge/Vortex for PCR plates CVP-2

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

4L Instant Water Boiler Instructions for Use

GMH 285 / GMH 285-BNC

USER MANUAL AND TECHNICAL MANUAL

I N S T R U C T I O N S

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

METAL CERAMIC FAN HEATER

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Instruction Manual for the Revolutionary Science RS-PB-100 Poly Pro Bath TABLE OF CONTENTS

StableTemp Digital Hotplates, Stirrers and Stirring Hotplates

SCHWAN INSTALLATION GUIDE

IMR IX176 Portable Gas Detector User Manual

SimpleVIS Viscometer Reference Guide P

Ingenieurbüro M.ZippererGmbH

CLASSIC PLUS INFRARED ZONE HEATER

Bench-Top Vacuum Oven with 28 segments programmable controller

INDUCTION COOKER User Guide

Essential Equipment for Advanced Laboratory Use. Rotary Evaporator TOKYO RIKAKIKAI CO., LTD.

Intelligent Super Toilet AFC230 User Instruction Manual

Thermo CTP-E45T 0 Pot

OVA-EASY ADVANCE. HATCHER User Instructions

Inverter Swimming Pool Heat Pump

Operation Manual NOVA LIVE S

WARM LINE. IV Fluid Warmer. Product Code: J1448. JORGENSEN LABORATORIES PHONE FAX

THERMO POT MODEL: ETP-G5083(CG) Owner s Manual. For The Warranty Terms & Conditions, Please Refer To Warranty Certificate.

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Pasto Sous vide water bath

USER MANUAL. FairWind FWPC6L Pressure Cooker. Contact Us:

Transcription:

A Geno Technology, Inc. (USA) brand name Incubating Shaker with Cooling Cat. No. BT916 1-800-628-7730 1-314-991-6034 info@btlabsystems.com

Thanks for choosing BT Lab Systems BT916 Incubating Shaker with Cooling. This operation manual describes the function and operation of the instrument. In order to use the instrument properly, please read this manual carefully. IMPORTANT SAFETY INFORMATION Users should understand how to use the instrument properly before operating it. Please read this operation manual carefully before using the instrument. The operation, maintenance and repair of the instrument should comply with the basic guidelines and warnings below. Ignoring these instructions will affect the life of the instrument and safety precautions. This product is an indoor Instrument. These units are designed for laboratory use by persons knowledgeable in safe laboratory practices. The operator should never open or repair the instrument. Opening or repairing the instrument will void the guarantee and can cause accidents. The power plug should safeguard against an electric shock. The 3-pin plug supplied with the instrument should be matched with a suitable grounded socket. The temperature of the metal block will be very high during the normal operation. This will produce scalding or boiling liquid. Do not touch any part of the body to the instrument to avoid scalding. Close the test tube lid before putting the tube into the block. Liquids may spill out in the block or onto the device if the tube lid is opened, which will damage the block or the device. Make sure the outlet voltage complies with the voltage required. Make sure there is nothing else plugged into the same outlet. Hold the plug when pulling out the power line. Do not plug the cord in where it is a tripping hazard. The instrument should be used in an area with low temperature, little dust, no water, no sunshine or hard light and with good air circulation. Do not use where there is corrosive gas or a strong magnetic field. Keep far away from central heating, camp stove and other hot sources. Do not put the instrument in a wet and dusty area. The vent on the instrument is designed for aeration. Do not wall up or cover the vent. The distance between each device should be more than 100cm when there is more than one instrument. The main switch is on the rear of the device. Turn to I to power on the device, and Turn to O to power off the device. Power off when not in use. If the instrument will not be used for a long period, unplug, and cover with a piece of cloth to protect it from dust. In case of the following, unplug the instrument at once and contact BT Lab Systems. o o o o o The instrument comes into contact with liquid The instrument gets soaked or burned The instrument emits an abnormal sound or smell The instrument is dropped or the outer shell damaged The instrument functions abnormally. Page 2 of 12

MAINTENANCE The well in the block should be cleaned with a cloth dampened by alcohol to assure good heat conduction between the block and the test tube. If there are smudges on the instrument, clean it with a dry cloth. Power off when cleaning the instrument. Do not drop the cleaning fluid in the well. Do not corrosive cleaning fluid. INTRODUCTION The Incubating Shaker with Cooling is an ideal instrument for intensive mixing of samples with regulated temperature conditions. Shaking and thermo modes (heating or cooling) can be used both simultaneously and independently as well as setting the time. It is a shaker with a thermostat. The main body of the mixing block can be used with different kinds of blocks. The instrument is used for DNA analysis, extraction of lipids and other cell components, DNA library creation, PCR amplification, pre-denaturation in electrophoresis and serum solidification. KEY FEATURES Optimized 2D mixing control, over 3mm mixing orbit LCD display. Easy to set and use Accurately control and display time, temperature and speed Overheating protection device Temperature can be calibrated to meet user's needs Low noise and stable Conforms to CE safety standard Customized blocks are available Can be used for micro test tubes, PCR plates, deep-well plates and MTPs Gentle, reliable mixing with long-life brushless motor NORMAL OPERATING CONDITIONS Ambient Temperature: 5 C 30 C Relative Humidity: 70% Power: AC100-230V~ 1.5A 50-60HZ Page 3 of 12

TECHNICAL SPECIFICATIONS Mixing Rate: 300 ~1500rpm Orbit: 3mm Temperature Setting Range: 0~100 C Temperature Controlling Range: 0 C ~100 C @ R.T. 20 C 4 C ~100 C @ R.T. 25 C 10 C ~100 C @ R.T. 30 C Timing Range: 1min ~ 99h59min Temperature Accuracy: ±0.5 C Display Accuracy: 0.1 C Heating Time: 20m in (2 0 Cto1 0 0 C ) Cooling Time: 25min (R.T. to R.T.- 20 C ) Tube Stand: PCR96x0.2ml 24x0.5ml 24x1.5/2.0ml Power: 90 ~230V 250W Fuse: 250V 3A Ф5 20 Dimension (DxWxH): 270 x 196 x 170 (mm) Net Weight: 8.3kg INTRODUCTION This section mainly describes the instrument s mechanical structure, the keyboard and functions of each key. Please learn this chapter well before the instrument is operated for the first time. EQUIPMENT OVERVIEW Standard Block Keyboard Page 4 of 12

Power Connector Fuse Power Switch KEYBOARD AND DISPLAY PANEL Current Segment Current Temperature Current Speed Remaining Time Setting Segment Setting Temperature Setting Speed Setting Time KEY FUNCTION SEG UP and DOWN arrow TEMP UP and DOWN arrow Key for selecting procedure segment. Five segments can be Selected: (S1, S2, S3, S4, S5). Key for setting temperature. Press UP or DOWN arrow to set the target temperature. Holding UP or DOWN arrow can quickly set the temperature. Hold the DOWN arrow key until it displays OFF on the LCD to shut the temperature function off. Page 5 of 12

SPEED UP and DOWN arrow TIME UP and DOWN arrow PROG. SHORT MIX START/STOP Key for setting speed. Press UP or DOWN arrow to set the target speed. Hold UP or DOWN arrow to quickly set speed. Hold DOWN arrow key until it displays OFF on the LCD to shut off the shaking function. Speed setting unit is 1rpm. Key for setting time. Press UP or DOWN arrow to set the target time. Hold UP or DOWN arrow to quickly set time. Hold DOWN arrow key until it displays OFF on the LCD to shut off the timing function. Key for programming. Press PROG to select segment. Default starting segment is S1. The instrument can implement 4 programs S1-S2, S1-S2-S3,S1-S2-S3-S4, S1-S2-S3-S4-S5. Press to shake. Release to stop. The device shakes at the speed of current selected segment. Key to start or stop. Press Start/Stop key to start or stop the program. To stop the program while in operation, hold the start/stop key for around 2 seconds. HEATING The indicator light flickers when the instrument is heating or cooling. The indicator light stays on when it reaches the temperature. Setting Single Temperature, Speed and Timing 1. When powered on the instrument enters into the initial program with a beep. 2. After 6 seconds, the LCD displays the program. Temperature unit is C, speed unit is rpm, and time unit is hour:minute. 3. Press UP or DOWN arrow of Temp. The temperature setting value will increase or decrease. Press UP or DOWN arrow of Speed or Time to set shaking speed or time. Hold UP or DOWN arrow to quickly increase or decrease the value. Instrument confirms and autosaves the setting value. After setting the program S1, press Start/Stop to run S1. When the program is finished, an alarm will beep five times. Shaking will be stopped. Temperature is kept at the setting value. NOTICE: Pressing UP or DOWN arrow of Temp will autostart the instrument to the setting temperature. If not pressing UP or DOWN arrow, press Start/Stop to start operation. 4. Press UP or DOWN arrow of Seg. to select Segment. Set the segment s values according to 3 above. A total of five segments can be set for operation. Page 6 of 12

How to Set Connecting Multi-program 1. Press Prog. to connect segment S1, S2, S3, S4, S5 to operate as S1-S2, S1-S2-S3, S1-S2-S3-S4, S1-S2-S3-S4-S5. NOTICE: Multi-programs start from S1. 2. Example: to connect programs S1-S2-S3-S4. Press Prog., LCD displays S1 which is the starting segment which could not be changed. S2 is the ending segment. Press UP arrow of Seg. until it shows S4. Then press Prog. to confirm the value. S1 changes to S14. Multiprogram set is S1-S2-S3-S4. 3. Press Start/Stop to operate the multi-program S1-S2-S3-S4. NOTICE: After setting the segment, press Start/Stop to operate the multi-program. How to Shut off the Temperature, Speed and Timing Function 1. Press UP or DOWN arrow of Seg. to select one segment from S1, S2, S3, S4, S5. 2. Press DOWN arrow of Temp. until it displays OFF on the LCD to shut off the thermo function. Similarly, press DOWN arrow of Speed or Time to shut off the shaking or timing function. NOTICE: a) Shut off timing function, the timing is. CON is displayed on the LCD. b) In multi-program operating, if timing function is shut off in one segment, program will operate at that segment continuously. Hold Start/Stop to stop the segment, operate after re-timing. Short Mix Hold Short Mix key, the instrument starts to shake, release Short Mix key, shaking stops. In the short mix mode, LCD displays 600RPM which is the shaking speed. 023S is the time, which means the instrument already operated 23 seconds. The time is counted in seconds. More than 999 seconds display is 999S. NOTICE: 1) The maximum short mix speed can be set in the current segment. 2) After multi-program is complete, the maximum short mix speed is the speed of segment S1. Temperature Calibration The temperature of the instrument has been adjusted before it is sold. If there is deviation between the actual temperature and the displayed temperature, you can do as follows to calibrate it. NOTICE: 1. The instrument has 3 calibration temperature points. It is linearly adjusted on 10 C, 40 C and 100 C. The temperature accuracy will be within ±0.5 C after temperature calibration. 2. Both the environmental and the block temperature should be lower than 30 C when calibrating. Page 7 of 12

Adjustment Methods: 1. Power on the instrument, it enters into waiting interface. Make sure the current temperature in display is below 30 C. If the temperature is higher than 30 C, please wait until it is down below 30 C. 2. Inject olefin oil into one of the block wells, and then put a thermometer into this well (the precision of the thermometer should be 0.1 C and the temperature ball should be absolutely immersed into the olefin oil in the block well). Adiabatic material is needed on the block to separate it from below. (refer to figure below) 3. Thermometer Adiabatic Board Heating Cover Block Well Olefin Oil NOTICE: To ensure the calibration precision, read the actual temperature value after the temperature reaches calibration point for at least 20 minutes. 3. Press UP and DOWN of Seg. simultaneously when the instrument is not operating. The program turns to interface. Practical temperature is behind P: which shows example 20.5, and the program auto control the temperature to 10 C. The sign * flickers. The value behind AdjTemP is the calibration temperature. When the temperature achieves 10 C, ADJ and * flicker together, the value behind P: is still practical temperature. 4. Wait for 20 minutes, the actual temperature of thermometer is example: 9.8 C. Press UP or DOWN arrow of Temp. to amend the value behind AdjTemP to 9.8. Page 8 of 12

Press Start/Stop to confirm. Program saves the value. Temperature rises to 40 C automatically. The sign * flickers. 5. When practical temperature reaches 40 C, ADJ and * flicker together. 6. Wait for 20 minutes, the actual temperature of thermometer is (example) 38 C. Press UP or DOWN arrow of Temp. to amend the value of AdjTemP to 38.0. Press Start/Stop to confirm. Program saves the value. Temperature rises to 100 C automatically. The sign * flickers. 7. When practical temperature reaches 100 C, ADJ and * flicker together. 8. Wait for 20 minutes, the actual temperature of thermometer is (example) 98 C. Press UP or DOWN arrow of Temp. to amend the value behind AdjTemP to 98.0. Press Start/Stop to confirm. 9. Program turns to interface for operation. After temperature calibration, the temperature display is the same as the practical temperature of block. NOTICE: 1. During temperature calibration, press UP and DOWN arrow of Seg. simultaneously to cancel the calibration. The system keeps the former calibration. 2. Do not simultaneously press UP and DOWN of Seg. unless calibration is really needed. Block Replacement 1. Open the cover and pull out the three screws which fix the block to the heating board with the screwdriver. Screw Page 9 of 12

2. Take out the screws pull out the block from the main instrument. 3. Take another block and lay it on the heating board. The block installment holes should line up with the holes in the main instrument. 4. Put the screws into the installment holes. Attach the block on the heating board of the instrument with the screwdriver. Attaching Tube Stand 1. Remove the block according to Block Replacement in above. Push the two bulges at rear of the stand to corresponding hollows of the base frame. Page 10 of 12

2. Push and press the front part of the stand until the PUSH button locks in the base frame. Attaching Plates Press one long side of the plate into the base frame. Press another side until the spring locks the plate. Make sure the plate is fastened. Page 11 of 12

TROUBLE SHOOTING Issue Possible Causes Solution No signals on the display when power on. The actual and displayed temperatures are much diff OPEN in the temperature display with a beep alarm. SHORT in the temperature display with a beep alarm. ERR in the temperature display with a beep alarm. No heating or cooling No power Broken fuse Broken switch Other Broken sensor Check the power Temperature sensor is broken or ambient temperature is below 0 C Temperature sensor is broken or ambient temperature is below 0 C Temperature sensor is broken or ambient temperature is below 0 C Broken sensor or broken TE module Button does not work Broken switch Very slow cooling or cooling Ambient temperature too temperature cannot reach the high target. Broken fan Bring down ambient temperature ERR in the speed display continuously with a beep ERR l in the speed display intermittently with a beep alarm Broken TE module Engine blocked Engine stuck TECHNICAL SUPPORT BT Lab Systems offers technical support for all of its products. If you have any questions about the product s use or, operation, please contact BT Lab Systems at the following: E-Mail: info@btlabsystems.com Page 12 of 12