SMART Electronic control for towel radiators

Similar documents
Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Manual. Electro Plus. Use and Installation ELECTRIC TOWEL HEATER

2 KW OIL FILLED RADIATOR

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

2 KW OIL FILLED RADIATOR

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important!

/ De Longhi Appliances via Seitz, Treviso Italia

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

Installation and user manual

Imperial Electric Fires

Control solutions Biofloor

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic

instructions FAN HEATER HVF3533 Please retain these instructions for future reference

SOME NOTIONS ON HUMIDITY

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

INSTALLATION AND USER MANUAL

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Executive. Hand dryer. High Speed

CONTROLS FOR ELECTRIC RADIATORS AND TOWEL RAILS

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

ONE. User Manual. Heating Element and Electric Radiator

/ De Longhi Appliances via Seitz, Treviso Italia

PC52 American Style Fridge Freezer

Clima Infrared Radiant & Convection Panel

EC300W. Evaporative Air Cooler OWNERS MANUAL. Read and save these instructions.

instructions OIL FILLED RADIATOR V V and V551225

pure indoor living DIGITAL ULTRASONIC HUMIDIFIER MODEL: BU7500 INSTRUCTION MANUAL

HR 601 C A AUS. ENGLISH Instructions for use Page 2

Dear Customer. Contents. 1) Vantage Electric Radiator characteristics Pag.3. 2) Technical specifications Pag.3. 3) Warnings Pag.4

USER GUIDE ENGLISH TOPSTART Ref. TSWZ, TSWRS or TSG Between 0.5 and 3 kw

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

Instructions for installation and use RE/I. Industrial electric heater for swimming pool

EN Instruction manual

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

OPERATION, MAINTENANCE AND SAFETY INSTRUCTIONS

Installation Instructions & Operating Manual IMPORTANT

Digital Electronic Thermostat With RF

Professional HEPA Air Cleaner

Dual Input ph/conductivity Analyzer

Dual Input Toroidal Analyzer

ST 53.1 User s manual

Instruction Manual. Please read these instructions fully before using this product. Smart Living Steam Mop. With all new design enhancements

MP920 SALT CHLORINATOR

Dual Input ph/orp Analyzer

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

PH1000T PH1500T PH2000T

VK902 Compact Combination Microwave Oven Installation, Use and Maintenance

Line Voltage Non- Programmable Thermostat Installation Instructions & User Guide

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

SERVICE MANUAL REFRIGERATION

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

Fog 1550 FT USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

HN6410 Induction Hob Installation, Use and Maintenance

DEVIATING VALVES ART K063

Rif Cod i220-0

4L Instant Water Boiler Instructions for Use

STEAM LITE S3251UKJR OWNER S GUIDE

ASSEMBLY INSTRUCTIONS FOR THE PUMP AND CONTROL UNIT ZPS 18a-01

MHC002 Ceramic Hob Manual for Installation, Use and Maintenance

OWNER S MANUAL. Part Number P CONTENTS

Digital Electronic Thermostat With RF

LC3000 Level Controller Installation and Maintenance Instructions

24 & 30 INCH DRUM FANS

USE AND INSTALLATION HANDBOOK

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Easy-Stat. Wireless Programmable Room Thermostat Pt No

WHA 3000P Hot Air Station

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

De Longhi Appliances via Seitz, Treviso Italia /11.13

18 INCH HIGH VELOCITY FLOOR FAN

Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).

PORTABLE AIR CONDITIONER MODEL NO: AC7000

User instructions DHP-AT

RADARAY XLi INSTALLATION & SERVICE MANUAL

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

DUO PLUS. Instruction manual

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

Transcription:

SMART is an electronic thermostat for the automatic control of electric towel radiators. By means of an internal sensor it is capable of keeping the temperature of the towel radiator to a desired value. Ten different electric resistances are available in a range between 100W and 1000W. Operative modes: Comfort, Boost, Standby/Antifreeze, Timer12 and Timer24. Comfort mode: The thermostat keeps the internal temperature at the value set by the user. Boost mode: In Boost mode the heating element is activated for a period of 2 hours independently of the configured temperature. The temperature is however automatically controlled in order not to exceed 65 C. At the end of the 2 hours period, the device returns to Comfort mode. Timer mode: The control system enters into Boost mode for 2 hours; after that it returns into Comfort mode for 22 or 10 hours (period configurable by the user) and then it enters again into Boost mode for 2 hours. This sequence is repeated endlessly. Standby/Antifreeze mode: In this mode the device goes in standby, however as soon as the measured temperature falls below 10 C the control system activates the heating element in order to prevent the internal liquid from freezing. SMART is a certified product: Available colors: - White (RAL 9003). SMART is compliant with the following standards: - Chrome - Eco-design Directive for Energy-using Products, 2005/32/EC (<0,5W). - EN 60335-1:2012 - EN 60335-2-30:2011 - EN 60335-2-43:2005 - EN 61000-3-2:2004 - EN 61000-3-3:1995 - EN 50366:2003 - EN 55014-1:2008 -EN 55014-2:1998

TECHNICAL CHARACTERISTICS Product Applications Towel radiators Insulation class Class I, Class II IP level IP44 Temperature setting Digital Selectable temperature range 40 C 65 C ; 10 C Antifreeze Operational temperature -10 C 40 C Maximal power See table below Supply voltage 230VAC 50Hz Size See figure below Warranty 2 years Standards -EN 60335-1:2012 -EN 60335-2-30:2011 -EN 60335-2-43:2005 -EN 61000-3-2:2004 -EN61000-3-3:1995 -EN 50366:2003 -EN 55014-1:2008 -EN 55014-2:1998 Approval mark CE Case ABS-VO Environmental directive WEEE, RoHS Electromagnetic compatibility 89/336/EEC Operative modes Comfort, Boost2h, Timer12h, Timer24h, Antifreeze/Standby, Key-lock. Thermostat status indicators Boost/Timer LED (red/green/amber). Comfort Bar with 6 LEDs: 1 blue, 1 green, 2 yellows, 2 reds Connection to mains 3 Cables (neutral, line, earth); Length 120cm; Italian plug: length 120cm; Swiss plug: length 120cm; UK plug: length 120cm; Schuko plug: length 120cm; 2 Cables (neutral, line);. Available colors White (RAL 9003); Chrome. Maximal temperature of the thermal fuse 152 C Power (W) 100 200 300 400 500 600 700 800 900 1000 Energy density (W/Cm 2 ) 1.5 2.9 4.0 4.1 4.1 4.1 4.0 4.0 4.0 4.0 L(heating element) (mm) 350 350 370 430 450 560 630 700 760 830 10 56 white Heating

WARNING RISK OF ELECTRIC SHOCK! Disconnect power supply before proceeding with installation. Preserve with care the present instruction sheet and read carefully before using the device. The present device has been designed for exclusive use on a towel radiator. The thermostat is designed for heating the liquid contained inside a towel radiator in combination with a heating element. Any other use is forbidden. Before using, carefully ensure that the line voltage is the same as that specified for the device (see technical specifications). Only use heating elements compatible with the type of used towel radiator. Disconnect power supply before cleaning or before performing maintenance of the product. In case of damage of the power supply cable shut down the device and do not tamper with it. The damaged power supply cables can be replaced exclusively by the manufacturer or by an authorized service center. Failure to comply with the above rules could lead to compromised system safety and void the warranty. Store and transport the heating element exclusively in the protecting packaging. Replacement of the heating element can be done exclusively by the product manufacturer.

Comfort technology division SMART Installation Guide To be used by installer only Disconnect the device from power supply before proceeding with installation. Protect the device with a 30mA RCD circuit breaker. 1) Insert the heating element in the threaded opening located on the bottom part of the radiator. 2) Securely fasten the electric resistance to the body of the towel radiator with a 22mm wrench. 3) The special sheath ensures a secure mounting and eventually allows a slight supplemental torsion to perfectly align the thermostat with the radiator. 4) Tilt the radiator as in fig. 3, making sure that the opening on top of the radiator is located on the highest side. WARNING. Do not lean the radiator on the electronic control! 5) Fill the radiator with the specific liquid. 6) Put the radiator back in vertical position and check the internal level of the liquid (fig. 4). 7) Ensure a proper fastening of the heating element in the radiator. 8) Connect the device to mains and start heating (the top opening of the radiator must remain open!). 9) Set the maximal temperature and check the level of the internal liquid. Due to thermal expansion the liquid could brim over the radiator. 10) Remove the exceeding liquid (be careful to avoid burns!) in order to keep the thermostat dry and avoid the liquid reaching the border. When the level of the liquid stops growing wait for additional 5 minutes then stop heating. 11) If necessary, top up the radiator before the liquid cools down (keep the temperature of the internal liquid checked all the time). 12) Close the top opening of the radiator with the appropriate cap. 13) Hook the radiator to the wall. 14) Connect the device to the mains. Fig.3 Fig.4 Accessory: To allow a mixed usage of the SMART device, connect the T-piece to the towel radiator, insert the SMART device into the vertical manifold of the T- piece and connect the return line of the heating circuit to the orthogonal connector of the T-piece. Available Colors: White, Chrome. Rev. 05 July 2015

User Guide Comfort Bar : Indicates the selected temperature and further accessory information On/Standby button Heating element 1/2" GAS thread for fastening on the radiator Boost/Timer Button: To select one of Boost, Timer12 and Timer24 modes [+] and [-] buttons: For setting the desired temperature Boost/Timer Led: Small red/green/amber light indicator to inform about the current active mode Power cord Internal NTC sensor: Used for automatic temperature control Comfort Bar 50 C 55 C 45 C 60 C 40 C 65 C

Press the [On/Standby] button to turn on the device or to enter the Standby/Antifreeze mode. NOTE: When the device is switched to "Standby/Antifreeze" mode, it beeps twice for 0.5sec. When the device is switched to On mode (i.e. it is turned on), it beeps for 1sec. Comfort mode: In this mode the desired temperature of the radiator is selected. The temperature value is set through the [+] and [-] buttons to one of the following values: 40 C, 45 C, 50 C, 55 C, 60 C, 65 C. The rightmost lit or blinking LED in the Comfort bar indicates the selected temperature. A blinking LED indicates that the corresponding temperature has not yet been reached during the heating phase. When a certain temperature level is reached, the corresponding LED stops blinking and remains lit. Example: The device is firstly turned on. Pressing 4 times the [+] button, the desired temperature is set to a value of 55 C (the first 4 LEDs from the left start blinking). The radiator starts heating. When the temperature of the radiator reaches 40 C the first (blue) LED stops blinking and remains lit. After some time, the temperature reaches 45 C and the second (green) LED also stops blinking and remains lit. The same behavior applies to the two subsequent (yellow) LEDs, until the desired temperature of 55 C is reached (all LEDs stop blinking). Standby/Antifreeze mode: In this mode the device goes in standby, however as soon as the temperature of the radiator falls below 10 C, the heating element is automatically powered on.

Boost mode: Press the [Boost/Timer] button to activate this operative mode. This mode activates the heating element to the maximum power for 2hrs (for safety reasons the maximal temperature is limited to 65 C). To exit the Boost mode press the [Boost/timer] button. Boost mode indication: "Boost/Timer" LED has red color and it blinks. Timer24 mode: Press the [Boost/Timer] button for 3 seconds to activate this mode. The control system activates the Boost mode for 2 hours, after that it returns into Comfort mode and after 22 hours the Boost mode is started again for 2 hours. This sequence will repeat endlessly. To exit the Timer24 mode press the [Boost/Timer] button. NOTE: During the first cycle the duration of the Comfort mode is of 21 hours. Timer24 indication during 2hrs Boost : Boost/Timer LED blinking green. During 22hrs Comfort : Boost/Timer LED permanent green. Timer12 mode: Press the [Boost/Timer] button for more than 5 seconds to activate it. The control system activates the Boost mode for 2 hours, after that it returns into Comfort mode and after 10 hours the Boost mode is started again for 2 hours. This sequence will repeat endlessly. To exit the Timer12 mode press the [Boost/Timer] button. NOTE: During the first cycle the duration of the Comfort mode is of 9 hours. Timer12 indication during 2hrs Boost : Boost/Timer LED blinking amber. NOTE: For safety reasons, the maximal temperature of the radiator during the 2hrs boost is limited to 65 C. Functional diagram During 10hrs Comfort : Boost/Timer LED permanent amber. Standby Comfort BOOST 2h BOOST Timer 24 Press once Press for 3sec Press for 5sec BOOST Timer 12 Rev. 05 July 2015

Boost/Timer LED functioning summary Blinking red Blinking Green Permanent green Blinking amber Permanent amber "Boost" mode active. The heating element is powered for 120 minutes (temperature of the radiator automatically limited to 65 C). "Boost" function active in Timer24 mode. The heating element is powered for 120 minutes (temperature of the radiator automatically "Comfort" function active for 22hrs in Timer24 mode. "Boost" function active in Timer12 mode. The heating element is powered for 120 minutes (temperature of the radiator automatically "Comfort" function active for 10hrs in Timer12 mode. Key lock function: It is possible to lock the buttons of the device to avoid inadvertent modifications of the settings. Press together the [+] and [-] buttons for 3 seconds to lock all the buttons except the [On/Standby] button. To unlock the buttons press again together the [+] and [-] buttons buttons for 3 seconds. When key lock is activated the device beeps twice. When key lock is deactivated, the device beeps four times. Additional indications provided by the Comfort Bar : - The two central (yellow) LEDs blink when a button is pressed: Key lock is active. - The external (blue and red) external LEDs blink: Failure on the temperature sensor, the heating element is deactivated. Contact customer support. Notes. In case of interruption of power supply, the system will recover from the previous operative mode*, with the exception of "Boost" and "Timer" modes. *The status of the device is saved 5 seconds after a modification occurs. Repairs carried out by unauthorized personnel invalidate warranty. The manufacturer reserves the right to make any changes to the product described in this manual, at any time, and without prior warning. DISPOSAL This product may not be treated as ordinary household waste. It has to be disposed in proper waste collection sites. In case of replacement it shall be returned to the distributor. Such an end-of-life treatment of the product will preserve the environment and will reduce consumption of natural resources. This symbol applied to the present product indicates the obligation to bring it to a proper waste collection site, in order to let it be disposed according to 2002/96 / CE (RAEE - WEEE) directives.