OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES

Similar documents
OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES

OMNIA FAN COIL FOR RESIDENTIAL APPLICATIONS EXCLUSIVE DESIGN, NUMEROUS VERSIONS. Floor & ceiling installation Applicable with VMF management system

FCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option

Fan coils with Inverter Brushless motor (EC) Universal and floor installation FCZI_U

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

VARIABLE MULTI FLOW VMF integrated system Hydronics at your command

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

COMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT

MORE VALUE TO YOUR WELL-BEING

FAN COIL UNITS LASER / LOW BODY / CONCEALED

SIGMA PRISMA LOW BODY CONCEALED

FCZ / FCZI FAN COIL UNITS FROM EUROPE S LEADING SUPPLIER

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

Aerslim Fancoil unit. Technical information manual. Western Airconditioning B.V. Tel. +31 (0)

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)

QTS SELECTION TECHNICAL BOOKLET

Blower-YEFB-020-3R-1maxVel

UCS UCS/M UCS/H UCS900

Conditioning your ambient, maximising your comfort.

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

SWP. Water heater with SWP heat pump Hot water finally costs less. + Efficiency + Savings + Wellbeing

COMFORT HYDRONIC TERMINALS

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

Elegance and design for your residential comfort

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

Conditioning your ambient, maximising your comfort.

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

GHE Dehumidifiers for radiant cooling systems with heat recovery

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

YFCN Fan Coil Unit centrifugal fan

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

NEW GREEN TECHNOLOGY

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Do you want a versatile solution

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

Omnia UL_R-UL_RI FANCOIL - TECHNICAL FAN COILS

System architecture. Air treatment Index

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

CRIMSON & CRIMSON MAX

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

NEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Table of Contents. 2 aermec.us

COMPACT AIR HANDLING UNIT

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Aqua 1 plus Air-water heat pumps for domestic hot water production

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Just feel well. 2017/2018 Air conditioning

SIMPLICITY OR FULL MODULARITY?

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

Neosys Product catalogue

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

Europe s new energy label: raising the bar on energy efficiency

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

HVAC product labelling and certification

ECM Technology. Technology. Features. Advantages (compared to traditional brushed motors) Power consumption: YFCN versus YFCN-ECM (W/kW)

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

TopVent Design Handbook

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Liebert HIROSS for Telecom

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

b!klimax Ceiling and Wall Radiant System. Innovative Wellbeing.

Technical documentation Fan coil unit

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Low Temperature Radiator GB 01. Heating & Plumbing. Ideas to install

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

A NEW BEGINNING IN FAN COIL HISTORY

Fan Coil Units. Technical Data FWC-BT/BF

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

DATATECH. Precision air conditioners for technological environments 6 220

High efficiency air to water Heat pumps LZT series

Conditioning your ambient, maximising your comfort.

Air cooled industrial chillers

Transcription:

OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES Floor & ceiling installation On/off & inverter versions, applicable with VMF management system

OMNIA RADIANT AND OMNIA RADIANT PLUS Omnia Radiant and Omnia Radiant Plus innovative solutions. In this particular worldwide market evolution, we are pleased to present to you OMNIA Radiant, which represents the innovation of the OMNIA AERMEC series, fan coils especially designed for residential comfort. OMNIA Radiant inherits all the advantages of the OMNIA UL series, and is characterized by the introduction of the frontal plate for radiant heating*. OMNIA Radiant Plus is provided with the DC Brushless electric engine, equipped with the latest Inverter technology, granting the highest energy efficiency and able to regulate the air flow through the continuous fan speed modulation. This allows to achieve up to 60% in energy saving when compared to the traditional On-Off fan system, in both air conditioning and heating. * Radiant Technology under licence

The 4 different working modes of Omnia Radiant annual functioning In winter time Omnia Radiant can heat the space in 4 different ways: Radiant Heating through radiation, comfortable and noiseless, is granted by the radiant plate placed on the front of the fan coil cover; if necessary, the triple-fins delivery head can be closed to increases the heating of the plate, thus maximizing the radiant effect. Radiant + Natural Convection With the triple-fins open, heating through natural convection, obtained thanks to the bigger coil exchange surface, is added to the radiant heating. As for the radiant-only mode (see above), the fan groups are in off mode. This results in acoustic comfort and energy saving.

Radiant + Forced Convection The electronic regulation, precise and reliable, continuously compares the effective indoor temperature with the desired temperature: whenever the difference between the two should prove to be too high (e.g. during the heating system start-up) the software will lead the fan system start-up. Startup is fast and efficient and grants significant energy savings especially in rooms that are occasionally used. Forced Convection During summer, Omnia Radiant and Radiant Plus provide air conditioning and dehumidification for each room of the house in a fast and efficient way. Efficiency and quietness benefit from the quality that has always characterized the Omnia series.

3 best comfort heating levels Omnia Radiant can manage three levels of heating during winter: - Radiant - Radiant + Natural Convection - Radiant + Forced Convection During winter operating mode, OMNIA Radiant and Radiant Plus will give priority to indoor heating through radiation, exactly as an usual radiator, using natural convection and forced convection only when it is needed (e.g. for the start-up). 1 2 3 4 Kit comprising motorized 3-way valve, unions and copper pipes (accessory). 1 Radiant plate 3 Water probe 2 Switching valve 4 Condensate storage container, hydraulic hoses

Features of the Omnia Radiant series The radiant plate combination the finned coil allows the best winter comfort with the lower energy consumption because it provides heating with lower water temperature: only 45 C against the about 65 C needed for the traditional radiator. This not only increases the comfort for the user, but also significantly increases the overall efficiency in case of heat pumps usage. The unit can be combined other than the boiler, also to energy saving heat pumps: air to water, water to water and geothermic type. The electrostatic charge filter standard supplied, provides pure and clean air. The fan system allows to quickly reach the desired temperature, meeting the requirement of a fast start-up. During summer Omnia Radiant and Radiant Plus provide air conditioning and dehumidification in a fast and efficient way in every room. OMNIA Radiant e Radiant Plus fan coils, combined with the innovative annual cycle AERMEC heat pumps technology, during summer refresh and dehumidify the house. VMF-E4D * VMF-E4 As awared by Chicago Athenaeum: Museum of the Architecture and Design Radiant e Radiant Plus can also be controlled through the innovative VMF System: the Manage and Control System of the whole heating, air conditioning, controlled mechanical ventilations and domestic hot water production. The VMF allows all the system devices to interact between them: boiler/heat pump, fan coils and possible renewable energy integration system. * Winner for the International design Award Good Design 2010 for the Electronics

Technical Data Omnia UL_R 26 36 Fan speed H M L H M L Heating Performance - 2 pipe configuration Heating capacity (70 C) (1) kw 4,62 3,83 2,89 5,94 4,87 3,53 Heating capacity (50 C) (2) kw 2,75 3,54 Water flow rate l/h 397 511 Pressure drop kpa 17 21 Static heating power (70 C) (3) kw 0,65 0,75 Static heating power (50 C) (4) kw 0,39 0,45 Static heating power (35 C) (5) kw 0,20 0,23 Cooling Performance Total cooling capacity (6) kw 2,03 1,78 1,42 2,83 2,31 1,73 Sensible cooling capacity (6) kw 1,64 1,37 1,05 2,04 1,79 1,28 Water flow rate (6) l/h 349 487 Pressure drops (6) kpa 18 22 Water content l 0,8 1,1 Fans Fan type/n centrifugal/2 Air flow rate m3/h 350 270 190 460 350 240 Sound data Sound power level (7) db(a) 48 43 35 50 43 34 Sound pressure level db(a) 40 35 27 40 33 26 Diameter connections Standard coil Ø(mm) 14 14 Electrical Features Absorbed power W 35 42 Max. input current A 0,18 0,22 Electrical connections V3 V2 V1 V3 V2 V1 Power supply V/ph/Hz 230V~50Hz Energy Efficiency classification (EUROVENT) FCEER D D FCCOP (8) D D H max. speed; M med. speed; L min. speed (1) Room air 20 C b.s.; Water (in/out) 70 C/60 C; (2) Room air 20 C b.s.; Water (in) 50 C; Water flow rate as in cooling mode (EUROVENT) (3) Radiant power + natural convection; Hot water (in) 70 C (water flow same as in heating cycle) (4) Room temperature 20 C b.s.; Hot water (in/*) 50 C/* C (water flow same as in heating cycle) (5) Radiant power + natural convection; Hot water (in/*) 35 C/* C (water flow same as in heating cycle) (6) Room air 27 C b.s./19 C b.u.; Water (in/out) 7 C/12 C (EUROVENT) (7) Sound power level on the basis of measurements made in compliance with Eurovent 8/2 (8) FCCOP Related to: Room air 20 C b.s.; Water (in) 50 C; Water flow rate as in cooling mode Level of sound pressure (A-weighted) measured in the room with volume V = 85m3 ; reverberation time t = 0.5s; direction factor Q = 2; distance r = 2.5m Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

Technical Data Omnia UL_RI 26 36 Fan speed H M L H M L Heating Performance - 2 pipe configuration Heating capacity (70 C) (1) kw 4,62 3,83 2,89 5,94 4,87 3,53 Heating capacity (50 C) (2) kw 2,75 3,54 Water flow rate l/h 397 511 Pressure drop kpa 17 21 Static heating power (70 C) kw 0,65 0,75 Static heating power (50 C) (4) kw 0,39 0,45 Static heating power (35 C) (5) kw 0,20 0,23 Cooling Performance Total cooling capacity (6) kw 2,03 1,78 1,42 2,83 2,31 1,73 Sensible cooling capacity (6) kw 1,64 1,37 1,05 2,04 1,79 1,28 Water flow rate (6) l/h 349 487 Pressure drops (6) kpa 18 22 Water content l 0,8 1,1 Fans Fan type/n centrifugal/2 Air flow rate m3/h 350 270 190 460 350 240 Sound data Sound power level db(a) 48 43 35 50 43 34 Sound pressure level db(a) 40 35 27 40 33 26 Diameter connections Standard coil Ø(mm) 14 14 Electrical Features Absorbed power W 12 16 Max. input current A 0,18 0,22 Electrical connections 9V 7V 5V 9V 7V 5V Power supply V/ph/Hz 230V~50Hz Energy Efficiency classification (EUROVENT) FCEER D D FCCOP (8) D D participate in the EUROVENT program: FCU the products are present on the site www.eurovent-certification.com

Dimensions Wall installation Floor installation Dimensions in mm OMNIA ULR - ULRI u.m. 26 36 Height (mm) Width(mm) Depth (mm) Height with - Accessories (mm) Weight (1) A B C D (Kg) 606 980 173 93 20 606 1200 173 93 24 (1) Standard configuration of unit with accessories Please note: the coil of the Omnia Radiant series fan coil unit has hydraulic connections on the left side and is not reversible.

S.p.A. Via Roma, 996 37040 Bevilacqua (VR) - Italia Tel. + 39 0442 633111 Fax +39 0442 93577 sales@aermec.com www.aermec.com All specifications are subject to change without prior notice. Although every effort has been made to ensure accuracy, does not assume responsibility or liability for eventual errors or omissions. Cod. DOULRUY_01