Installation, Operation, Maintenance and Service Instructions. Fryer Model: 130F

Similar documents
Electric Cruise Line Single Broiler w/ Cabinet Base CLB V CLB V

Electric Cruise Line Double Broiler w/ Oven Base CLB36S-2-440V CL36B2OLF440

Installation, Operation, Maintenance, & Troubleshooting Model: CLS36-440V Electric Cruise Line Salamander Serial:

Installation, Operation, & Maintenance. Electric Cheese Melter. Model: 124CM, 136CM and 148CM

Installation, Operation, & Maintenance Model: MM24, MM36 and MM48, Electric Cheese Melter

Installation, Operation, and Maintenance Instructions with Troubleshooting Electric Full Size Economy Convection Oven Models: FCOFL-AT (Lower)

Installation, Operation, Maintenance, & Troubleshooting Model: R60S Standard Bake Oven Range

Installation, Operation, Maintenance, & Troubleshooting Model: CLG-36-S Electric Cruise Line Griddle Serial:

Installation, Operation, Maintenance, & Troubleshooting Model: EQS-AP Quarter Size Convection Oven

TM... TECHNICAL MANUAL. Fryer, Deep-Fat, Electric w/solid State Controls NSN:

Installation, Operation, & Maintenance Model: 236CM, 248CM, Gas Infrared Cheesemelter

THERMOSTATIC DROP-IN ELECTRIC GRIDDLE 136TDI, 148TDI, 160TDI

TECHNICAL MANUAL TM... Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN:

Installation, Operation, & Maintenance Model: PPP, Electric Air Door Pizza Oven

ELECTRIC CLAMSHELL CSE12-208VCD, CSE12A-1, CSE12A-2

Model: CSG24. Installation. Operation. Maintenance. Troubleshooting. Add-on Clamshell Hood

2M-W353 Rev. I 1/07/ S IL1381

SHIPBOARD ELECTRIC CONVECTION OVEN ECOD-AT, ECODL-AT ECOF-AT, ECOFL-AT

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

ELECTRIC GRIDDLES TMGE24, TMGE36, TMGE48. Installation and Operation Instructions 2M-Z12971 Rev. - Oct. 1, 2009 MODEL TMGE36 IL1880

CART & TROUGH ASSEMBLY for BRAISING PAN UNITS

S6161-KW-FSE-010/ LP

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

PARTS MANUAL. American Dish Service. ADS HIGH TEMP SINGLE RACK DISHMACHINE MODELS: HT-25 5 WIRE 110 Volt Control System

CONVEYOR TOASTER MODEL QCS QCS Installation and Operation Instructions 2M-HG0657 Rev. D 6/13/05

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

INSTALLATION, OPERATION & MAINTENANCE MANUAL

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 2M-Z3755 Rev. J 10/26/11 175CBA.

PARTS MANUAL. American Dish Service MODEL: 5-AG-S ADS LOW TEMPERATURE DISHWASHER EFFECTIVE: JULY, 2013 C 4/08

HOT FOOD HUMIDITY CABINET MODEL HFD-3

Model LRC7 Rethermalizing Oven OPERATION, INSTALLATION, SERVICE and PARTS MANUAL

STANDARD FRYERS COUNTERTOP MODELS F14 F49 F55 F67 F85 F1725 OWNERS MANUAL. Includes INSTALLATION USE & CARE EXPLODED VIEW PARTS LIST WIRING DIAGRAM

RW1HD RW2HD RW3HD RWN1 RWN2 RWN3

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

IRCS2-SBD Conveyor Toasters

Service Manual Model 3163

PARTS MANUAL. American Dish Service ADS HIGH TEMP SINGLE RACK DISHMACHINE MODEL: HT Blake Street Edwardsville, Kansas (913)

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

B.I.C.A Built-In Coffee Appliance

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

Models A710 and A710S Grills. TOASTMASTER Models A710 and A710S Grills

HOT FOOD HUMIDITY CABINET

Installation Instructions

BUILT-IN ELECTRIC AUTOLIFT FRYERS MODELS F586 F686 F886 OWNERS MANUAL. Includes INSTALLATION USE & CARE EXPLODED VIEW PARTS LIST WIRING DIAGRAM

HOT FOOD HUMIDITY CABINET

MANUFACTURING NUMBERS: CORN CAROUSEL. Model CC-19 Series P/N /99. Owner s Manual

Installation Instructions

Installation Instructions

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

Installation Instructions

HOT FOOD HUMIDITY CABINET

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

JetStar COUNTER POPCORN POPPER. MODEL 39 & 86 Series Installation and Operation Instructions 2M-Y8397 Rev. O 7/12/10 86-S

Part No Revised January 30, 2007 SAFETY PRECAUTIONS

Installation and Maintenance Manual Please retain this manual for future reference.

REFRIGERATED CONDIMENT RAIL

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

PARTS LIST PL503 WVF-886 VENTLESS FRYER WITH OR WITHOUT ROLL WARMER CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10

Super Runner Series Electric Fryers

ELECTRIC DECK OVENS INSTALLATION & OPERATING MANUAL

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company

MODEL TA/3 INCLINED MIXER ASSEMBLY Domestic

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2014

MODELS BPM-15/30/40E(C,A) & BPP-30/40E(C,A) Domestic ERGONOMIC TILTING BRAISING PAN

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

Installation Instructions

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

Owner s Manual WARMER DRAWER. (Without Water Tray) Models WD-20, WD21A, & WD-35A. WD-20 Shown MANUFACTURING NUMBERS: P/N Rev.

IMPORTANT SAFETY INFORMATION

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 175CBA. 2M-Z3755 Rev. L 10/01/2015.

SOUP KETTLE COOKERS and HOLDERS MODELS 7C, 7H, 11C, 11H

INSTALLATION, OPERATION AND MAINTENANCE

CINCINNATI, OH USA

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

ELECTRIC COUNTER TOP CONVECTION OVEN

Installation Instructions

HD3D Forced-Air Heater

DRAWER ROLL/ BUN WARMER

GAS FULL SIZE COMPUTERIZED CONVECTION OVEN GCOF-T

OPERATIONS MAINTENANCE MANUAL

Water Boilers ME10EN, ME15EN. Table of Contents

Instruction Manual. Double Candy Apple Cooker

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual

Electric Garage Heater

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Model: PS-2 ProSense II Item # OPERATION SERVICE PARTS CARE

MODELS SSB-3E/5E/10EF, (2)SSB-3E/5E/10EF, SSB-3G/5G/10GF, (2)SSB-3G/5G/10GF

INSTALLATION AND SERVICE MANUAL

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Insta-Therm Series Service, Installation and Operation Manual

DIGITAL DIPLOMAT 20 and 32 oz POPCORN MACHINE SERVICE MANUAL

Transcription:

Installation, Operation, Maintenance and Service Instructions Fryer Model: 130F Star Manufacturing International 10 Sunnen Drive St. Louis, MO.63143-3800 Part Number: 2M-W478 Ph: 314-781-2777 Fax: 314-781-2714 Rev. B WWW.STAR-MFG.COM June 19, 2007

CAUTION DANGER WARNING NOTICE: CAUTION: EACH UNIT IS HEAVY. FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION. ANY STAND, COUNTER OR OTHER DEVICE ON WHICH FRYER WILL BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE FRYER. SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT. THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH. INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES. The data plate is located behind access door over tank drain. The fryer voltage, wattage, serial number, wire size, and clearance specifications are on the data plate. This information should be carefully read and understood before proceeding with the installation. The installation of any components such as a vent hood, grease extractors, fire extinguisher systems, must conform to their applicable National, State and locally recognized installation standards. During the first few hours of operation, you may notice a small amount of smoke coming off the melter, and a faint odor from the smoke. This is normal for a new melter and will disappear after the first few hours of use. ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM COMBUSTIBLE MATERIALS. KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY. IF SPILLS OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR FALLS.

WARNING: CAUTION NOTICE: WARNING: WARNING CAUTION: KEEP WATER AND SOLUTIONS OUT OF CONTROLS. NEVER SPRAY OR HOSE CONTROL CONSOLE, ELECTRICAL CONNECTIONS, ETC. MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS MEMBRANES AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER GLOVES, GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING. CAREFULLY READ THE WARNING AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED. Service on this or any other, STAR appliance must be performed by qualified personnel only. Consult your authorized service agent directory or call the factory at 1-800-807-9054 or visit our website WWW.STAR-MFG.COM for the service agent nearest you. BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE WHEN THE UNIT IS PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY. DO NOT THROW ICE INTO THE FRYER BASKET WHILE THE UNIT IS HOT. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY AND MAY DAMAGE THE EQUIPMENT. USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY STAR OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES.

Electric Fryer Counter Model The fryer dimensions are 19 (48.25cm) High, 32 (81.25cm) Deep, 15 (38cm) wide. The sides, bottom, and rear wall are constructed stainless steel. Floor Models The interior dimensions are 36 (91.5cm) High, 38 (96.5cm) Deep, 15 (38cm) wide. The Sides, Bottom, and Rear wall are constructed stainless steel. Controls Easy to use manual control knobs. Indicator lights for Power, Heat, and Over-temperature. The fryer is supplied with an auxiliary power interrupt terminal, which when connected, automatically shuts off primary power to the fryer.

Installation Receiving the Fryer Upon receipt, check for freight damage, both visible and concealed.visible damage should be noted on the freight bill at the time of delivery and signed by the carrier's agent. Concealed loss or damage means loss or damage, which does not become apparent until the merchandise has been unpacked. If concealed loss or damage is discovered upon unpacking, make a written request for inspection by the carrier's agent within 15 days of delivery. All packing material should be kept for inspection. Do not return damaged merchandise to Star Manufacturing Company.File your claim with the carrier. Prior to un-crating, move the fryer as near its intended location as practical. The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways. Electrical Connection Check the data plate located inside the drain valve door for fryer electrical rating. Check power source to insure that it is the correct voltage and current rating. Electrical service may be made through a standard 1¼-inch conduit. A hole is provided through the rear panel. A knockout is also provided in the bottom rear of the fryer, so that power may be brought in from below the unit. Connect power cord to 3-Pole terminal block, refer to wiring diagram. Plug the hole on the rear panel when using bottom power entry. Check the National Electrical Code for fuse or circuit breaker requirements. A two pole terminal block is provided behind the rear access cover for connection to an external fire control system if required. A jumper is provided across these terminals when the fryer leaves the factory. The jumper on this terminal block is in series with the contactor coil circuits. If connection to a fire control system is required, remove this jumper and supply a relay contact closure to maintain this closed circuit. If the fire control system does not have this type output, a separate relay must be provided to interface the system. Use copper wire only. PHASING CAUTION: DO NOT APPLY POWER TO THESE TERMINAL. EXTERNAL POWER WILL DAMAGE THE FRYER CONTROL CIRCUITRY. Connect a ground lead to the green ground lug provided in the rear compartment.these fryers are to be connected to three-phase power as follows: Connect wires 1 and 4 to line 1, wires 2 and 5 to line 2, and wires 3 and 6 to line 3. Please refer to wiring diagram for correct single/three-phase connections, if problems occur please contact factory. CAUTION: DO NOT CONNECT TO A CIRCUIT OPERATING AT MORE THAN 150 VOLTS TO GROUND.

General General Operation Fill the fryer with cooking oil. There are two fill marks on the sides of the kettle. The oil level should be maintained between the upper and lower marks. The power switch on the control box at the front of the fryer energizes the control circuits. When this switch is on, the power pilot lamp will be illuminated. Turn the temperature selector dial on the thermostat to the desired temperature setting. This control is located above the elements at the rear of the kettle. The heat pilot lamp will illuminate indicating power is applied to the heating elements. The lamp marked overtemp will illuminate if the oil reaches an over temperature condition. The over temperature thermostat shuts off the fryer before the oil reaches a dangerously high temperature. The elements may be raised and locked in the up position. The latch is located on the rear top surface of the fryer and may be activated by lifting the handle at either side of the fryer. A drain valve is provided at the left front of the fryer. Always turn the fryer power off before lifting the elements of draining the oil from the fryer. On those models with automatic bracket lifts, the cooking times may be set from 1 to 16 minutes with the timer control dials. Pressing down on the spring return elevator switches will lower the basket lifts. At the end of the time set on the dial the lift will return to the up position. The time cycle may be canceled at any time by pressing the elevator switch to the up position. Controls Power Switch - A toggle switch used to turn the unit on and off. Pilot Lights - Lights that are located in the rear control panel area. Power: Lights up when the power switch is in the ON position. Heat: Lights up when the element contactors engage. Over-temp: Lights up when the over-temperature thermostat trips. Test Switch Optional on all models, it gives the user the ability to test the overtemperature thermostat by overriding the thermostat and allowing the oil to exceed normal operating temperatures.

Sequence of Operation Electric Fryer Power switch to ON position 208/240 VAC to POWER pilot lamp. 208/240 VAC to Thermostat through Over-Temperature thermostat. Thermostat Set 208/240 VAC to HEAT pilot lamp. 208/240 VAC to Contactors. Contactors Energize 208/240 VAC to Elements. Elements Energize Fryer heats up.

Maintenance Maintenance of the C-28 series fryers is simple and straightforward. A bulb thermostat located near the right heating element as the fryer is viewed from the front provides temperature control. This thermostat controls the No. 1 contactor. The over temperature thermostat located next to the left heating element provides protection in case of malfunction of the temperature control. It will open both contactors removing all power from the heating elements. A circuit diagram of the fryer is located on the rear cover of the control box. This box may be removed by removing the four sheet metal screws located beneath the box on the left and right sides of the fryer lower front. In the event the fryer is built into a location, all maintenance may be done from the front by removing the oil pot to gain access to the contactors. To remove the pot, the control box must be removed as above. Also, remove the small section of sheet metal baffle held on by two sheet metal screws, located just above the drain valve. The front of the pot may now be lifted up and moved forward until the rear of the pot will rotate up and out. The baffles behind the pot may be removed by taking out four screws. This exposes the contactors. The thermostats are located in the head assembly. The bottom cover of the head is removable for access to the elements, thermostats and pilot lamps. In 480-volt units, a transformer is provided in the rear of the fryer to step 480 volts to 240 volts for operation of the control circuit.

Troubleshooting Will Not Heat PROBABLE CAUSE Incorrect voltage Defective Fuses Defective Power Switch Defective Over temperature thermostat Defective Thermostat Defective Contactor Defective Element CORRECTIVE ACTION Confirm that correct voltage is coming to unit. Confirm that unit is phased correctly. Confirm that fuses have 208/240 VAC to it. Check fuses for proper operation. Confirm that switch has 208/240 VAC to it. Check switch for proper operation. Confirm that thermostat has 208/240 VAC to it. Confirm that over temperature thermostat is closed and working properly. Confirm that thermostat has 208/240 VAC to it. Check that thermostat is operating properly. Confirm that contactor has 208/240 VAC to it. Check contactor for normal operation. (554 Ω) Confirm that elements are wired correctly. Confirm that element has 208/240 VAC to it. Confirm that there are no broken wires to the elements. Check Element for continuity. Overheating PROBABLE CAUSE Bulb out of placement Oil level to low Sticking contactor Food stuck between element and bulb. CORRECTIVE ACTION Confirm that bulb is centered in element. Confirm that bulb is secured in clips. Confirm that oil levels are at proper level. Confirm that points are not pitted. Replace if necessary. Remove food from element.

WIRE DIAGRAMS 208/240 VOLT

WIRE DIAGRAMS 480

52 50 51 1 43 45 44 31 32 49 48 47 53 3 2 4 5 6 42 35 41 33 32 33 34 46 7 8 9 40 35 36 39 38 37 29 30 10 28 11 12 27 13 25 26 14 24 15 23 16 22 1 2 26 27 28 30 32 33 52 21 18 Marine Application 20 19 17 Model Commercial & Marine 130F Counter Model Fryer C28 Counter Model Fryer SK2294 Rev. B 7/15/14

PARTS LIST Model No: 130F & C28 COMMERCIAL & MARINE ELECTRIC FRYER October 21, 2014, Rev C 130F & FM Commercial & Marine Fryer Fig No. Part No Qty Description Application 1 O9-C28-251 1 C28 SOLAS BUZZER W/WIRES 130F 208VM, 240VM, 440VM, 480VM 2 2E-30600-10 1 RELAY 2PDT 240V 130F 208VM, 240VM, 440VM, 480VM 2T-30401-13 STAT FXD TEMP 240VAC 450 F 130F 208V, 240V, 480V 3 2T-30401-21 1 STAT FXD TMP NEGBIAS 450 F 2T-30401-33 STAT FXD TMP NEGBIAS 490 F 130FM MARINE O9-C28-130 HEAD WRAP 130F 208VM, 240VM, 440VM, 480VM 1 4 O9-C28-130-1 HEAD WRAP FOR TEST SWITCH 130F 208VM, 240VM, 440VM, 480VM O9-C28-135 2 HEAD END ALL MODELS 5 O9-C28-136 HEAD PIVOT SUPPORT ALL MODELS 1 O9-C28-138 HEAD BOTTOM NO LIFT ALL MODELS 6 O9-C28-137 1 HEAD PIVOT ALL MODELS 7 2B-51100-02 1 BASKET HANGER ASSY (C28) ALL MODELS 8 O9-C28-134-1 2 CLAMP ALL MODELS 9 O9-C28-133 1 ELEMENT STOP A ALL MODELS 10 O9-C28-117 1 REAR COVER ALL MODELS 11 2E-30700-03 2 CONTC 3POLE 40A208-240VAC ALL MODELS 12 O9-C28-111-2 1 CONTACTOR MOUNT SPOTWELD ALL MODELS 13 2E-30500-09 1 TRM BLOCK 3 POLE SMALL 95 ALL MODELS 14 2E-30500-01 AR TRM STRP 2 POLE 30A 300V ALL MODELS 15 Y9-31200-02-1 1 GROUNDING LUG/+LABEL ALL MODELS 16 O9-C28-315 1 TRANSFORMER MOUNT 09-60102-327 17 O9-60102-322 1 CONTROL BOX ASSY, w/labels ALL MODELS 18 O9-C28-186 1 CONTROL BOX ASSY ALL MODELS 19 K9-60301-43-1 1 DIE CAST LOG + TINNERMAN ALL MODELS 20 2E-30303-06 1 SWT TOG ON-ON DPDT BLK ALL MODELS 21 2K-70302-15 1 PIPE NIPPLE 1X 2 1/2 BLK ALL MODELS 22 2V-70400-01 1 VALVE 1BALL NIC PLTD (NO ALL MODELS 23 O9-C28-109-01 1 VALVE ACCESS PNL ALL MODELS 24 2E-30900-15 2 FUSE 3 AMP AGC 130F 208V, 240V, 480V 25 2E-30901-02 2 FUS HLDR FOR 15AMP FUSE 130F 208V, 240V, 480V 26 2E-30303-13 1 SWT TOG ON-OFF-ON MOM MTL ALL MODELS 27 O9-50300-49 1 GRAB BAR ASSY 15 130F 208VM, 240VM, 440VM, 480VM 28 O9-C28-118 1 BUCKET WELDMENT ALL MODELS 29 O9-C28-182 ELEMENT ASSY. COMMERCIAL 130F 208V, 240V, 480V 1 O9-C28-181 ELEMENT ASSY. MARINE (NO-ELEM) 130F 208VM, 240VM, 440VM, 480VM PS-60101-W10 208VM 30 PS-60101-W11 1 ELEMENTS & BRKT ASSY - MARINE 480VM PS-60101-W12 440VM 31 O9-C28-174 1 EGO STAT HOLDER WELDMENT 130F 208V, 240V, 480V 32 O9-C28-184 2 OVER TEMP BULB BRKT 130F 208VM, 240VM, 440VM, 480VM 33 O9-C28-180 1 THERMOSTAT BULB BRKT ALL MODELS IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED INCLUDE MODEL AND SERIAL NUMBER Some items are included for illustrative purposes only and in certain instances may not be available. PAGE OF 1 2

PARTS LIST Model No: 130F & C28 COMMERCIAL & MARINE ELECTRIC FRYER October 21, 2014, Rev C 130F & FM Commercial & Marine Fryer Fig No. Part No Qty Description Application 34 O9-C28-154 1 ELEMENT HOLDER BACK ALL MODELS 35 2C-20301-45 6 NUT HEX 10-32 18-8 TOP ALL MODELS 36 O9-C28-153 1 ELEMENT HOLDER MIDDLE ALL MODELS 37 O9-C28-152 1 ELEMENT HOLDER FRONT ALL MODELS 38 2C-20111-02 1 SCRW HXHD CAP 1/4-20X3/4 ALL MODELS 39 O9-C28-158 1 HANDLE WELDMENT ALL MODELS 40 2C-20305-05 1 WELD NUT S/S 1/4-20 2-EAR ALL MODELS 41 2C-20303-01 1 NUT HX SS 1/4-20 ALL MODELS 42 O9-C28-155 2 ELEMENT CLAMP ALL MODELS 43 2C-20111-13 1 SCRW HXHD CAP 10-32X1 SS ALL MODELS 44 O9-C28-150 2 ELEMENT BRACKET SUPPORT ALL MODELS 45 2C-20111-09 AR SCRW HXHD CAP 10-32X1/2 ALL MODELS 2N-11110-39 ELMNT FRYER 480V 4KW C28 130F 480V AND 480VM 2N-11110-43 ELMNT FRYER 208V 4KW C28 130F 208V AND 208VM 46 2N-11110-44 3 ELMNT FRYER 240V 4KW C28 130F 240V AND 240VM 2N-11110-45 ELMNT FRYER 380V 4KW C28 130F-380VM 2N-11110-47 ELMNT FRYER 440V 4KW C28 130F 440VM 47 2T-30402-12 1 STAT ADJ 400 F 24 C/T ALL MODELS 48 O9-70701-06-2 KNOB ASSY TEMP CONTROLPNL RED KNOB ASSY 1 O9-70701-06 KNOB ASSY TEMP CONTROLPNL BLACK KNOB ASSY 2J-31601-15 PILOT LT 250V 6LEAD AMBER 130F 208VM, 240VM, 440VM, 480VM 49 2J-31601-16 1 PILOT LT 250V 6LEAD GREEN 130F 208VM, 240VM, 440VM, 480VM 2J-31601-20 PILOT LT 250V 6LEAD RED 130F 208VM, 240VM, 440VM, 480VM Y9-31601-01-1 3 PILOT LT 250V W/TIN CLIP 130F 208V, 240V, 480V 50 O9-C28-131-2 2 OVERTEMP STAT INSULATOR ALL MODELS 51 O9-C28-131-1 2 O.T. STAT SPACER ALL MODELS 52 2E-31400-04 XFRMR 480/240VAC 100VA 130F-440VM, 480VM 1 2E-31400-17 XFORMR 380/240VAC 100VA 130F-380VM 53 2K-70801-05 3 SNAP BUSHING, CAP TUBE NI 2P-70900-01 1 CAP PLUG 1-5/16IDX1.89 IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED INCLUDE MODEL AND SERIAL NUMBER Some items are included for illustrative purposes only and in certain instances may not be available. PAGE OF 2 2

START-UP Technical Data Element Resistance Part Number Voltage Amps Resistance 2N-11110-43 208 Volts 19 10.6 Ω OB-11110-41 240 Volts 7.6 29.6 Ω 2N-11110-39 480 Volts 8 56.6 Ω 2N-11110-46 415 Volts 9.5 40.1 Ω 2N11110-45 380 Volts 10.5 35.6 Ω Contactor Resistance Part # Voltage Coil OB-30700-05 208/240 Volts 554 Ω Transformer Resistance Part # Primary Resistance Secondary Resistance 2E-31400-04 480 Volts 66 Ω 240 Volts 16 Ω Fryer Line Amperage and Wattage All Series 28 Electric Fryers 12.0 kw Three Phase Loading Nominal Amps Per Line Three Phase Single Phase K.W. Per Phase 208 Volts 240 Volts 480 Volts 208v 240v L1-L2 L2-L3 L3-L1 L1 L2 L3 L1 L2 L3 L1 L2 L3 See See 4.0 4.0 4.0 33.3 33.3 33.3 28.9 28.9 28.9 14.4 14.4 14.4 Factory Factory

STAR MANUFACTURING 10 Sunnen Drive, St. Louis, MO 63143 U.S.A. (800) 807-9054 (314) 781-2777 Parts & Service (800) 807-9054 www.star-mfg.com