CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Similar documents
USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

USER S MANUAL. VKP Series INLINE FAN

HEAT RECOVERY AIR HANDLING UNIT

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

AXIAL FANS USER S MANUAL

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

Centrifugal inline fans

Turbo. Service Instructions

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

Wind. Service instruction

CENTRIFUGAL CEILING EXTRACT FAN

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

CENTRIFUGAL FANS user's manual. model VENTS VK.

CENTRIFUGAL CEILING EXTRACT FAN

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

HEAT RECOVERY VENTILATOR

USER'S MANUAL PS

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

Aero. Service Instructions

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Axial intelligent fan USER S MANUAL

Calm. Service Instructions

AIR HANDLING UNIT WITH HEAT RECOVERY

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

INTELLIGENT AXIAL FAN user's manual

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

Installation manual Mini Comfort 50 S/L 07/ V EN

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Air handling unit. BlauAir RH USER S MANUAL

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

HEAT RECOVERY AIR HANDLING UNITS

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

USER S MANUAL DN-2. Drain pump

AXIAL FANS user's manual. model Quiet

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

Installation and operating instructions. DK energy storage and DK energy buffer

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Turbo Inline Fan, White - Non Illuminated Art no.33500

Original instructions. Operation Manual & Cautions

White - Non Illuminated Art no White - Cool White LED Art no.32600

ENERVEX GSV GREASE FAN

ACN SMOKE INSTALLATION AND MAINTENANCE

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Operating Instructions

XB-EFA-8L-BK & XB-EFA-8R-BK

Operating instructions

ISCG90SS _03 ISCG90SS

IEC- Direct-driven radial fans with IEC-Standardmotor

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Use and Maintenance Manual. WPA-E-N/Ex. II 2 G c Ex e II T3. ATEX marking: Explosion proof stand fans WPA-E-N/Ex

USER S MANUAL UET CONTROL UNIT FOR THE AIR HEATING UNIT WITH ELECTRIC HEATER AOE SERIES

GLEB Kitchen exhaust fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

STORAGE, ERECTION, OPERATION AND MAINTENANCE MANUAL FOR CENTRIFUGAL FANS MODEL - MXE

Micro-Computer Induction Cooktop SR-1885SS

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

This label warns for risk of electrical shock when failing to observe.

Bar Fridge USER MANUAL MB46W

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

OWNER S MANUAL MULTIPURPOSE UTILITY AIR MOVER PLEASE READ AND SAVE THESE INSTRUCTIONS X-400WFK (WITH FILTER KIT) ITEM NO:

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Irene-H READ AND SAVE THESE INSTRUCTIONS

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Transcription:

CENTRIFUGAL FAN IN SCROLL CASING Helix S-Vent EN OPERATION MANUAL

Helix / S-Vent www.blaubergventilatoren.de CONTENTS CONTENTS 3 Introduction 3 Use 3 Delivery set 4 Technical data 10 Safety requirements 10 Design and operating logic 11 Mounting and set-up 12 Connection to power mains 15 Maintenance 17 Troubleshooting 17 Storage and transportation rules 17 Manufacturer's warranty 18 Acceptance certificate 18 Connection certificate 18 Warranty card 2

www.blaubergventilatoren.de TwinFresh Comfo RB(1)-50(-2) INTRODUCTION This operation manual includes technical description, operation, installation and mounting guidelines, technical data for Helix centrifugal fan in metal spiral casing with an integrated motor and an impeller with the diameter from 140 up to 250 mm as well as S-Vent centrifugal fan in a metal spiral casing with an external motor and a diameter with the diameter from 140 up to 500 mm, hereinafter the fan. USE The centrifugal fans are designed for supply and extract ventilation of residential, public and industrial premises. The unit is rated for permanent operation. The transported air must not contain any dust or other solid impurities, sticky substances or fibrous materials. DELIVERY SET fan 1 item; operation manual 1 item; Fixing bracket for Helix model 1 item; Packing box 1 item. Accessories: Intake air grille SG-H, SG-SV; Air intake flange FRZ-H, FRZ-SV; Rubber vibration isolators SI-G; Spring-loaded vibration isolators SI-F. 3

Helix / S-Vent www.blaubergventilatoren.de TECHNICAL DATA The fan is designed for indoor application with the ambient temperature ranging from 0 C up to +45 C and relative humidity up to 80 %. The fan design is regularly improved, so some models may slightly differ from those ones described in this manual. Ingress Protection (IP) rating from solid objects and liquids is IPX4 for the Helix models and IP54 for the S-Vent fans. The main overall and connection dimensions, outer view and technical data are stated in Fig. 1 and in tables 1, 2, 3, 4. DURING THE FAN OPERATION AND THE TRIAL RUN OF THE UNCONNECTED FAN THE AIR FLOW AND THE CURRENT CONSUMPTION MUST BE WITHIN MAXIMUM ALLOWABLE VALUES FOR THE APPLICABLE FAN SIZE, SEE THE HIGHLIGHTED AREAS IN TABLES 1, 3 AND FIG. 1.1 1.19. THE MOTOR OVERHEAT PROTECTION MUST BE PROVIDED! Table 1 Fan model Supply voltage, 50 Hz [V] Power consumption[kw] Current consumption [A] Automatic switch trip current [A] RPM [min-1] Noise level, 3 m [dba] Max. transported air temperature [ C] Rubber vibration isolators Accessories compatibility Spring-loaded vibration isolators Flange Grille S-Vent 140x74-0,25-4D 400 0,25 0,8 1,6 450 1350 60 60 S-Vent 140x74-0,37-2D 400 0,37 0,9 1,6 710 2730 65 60 S-Vent 160x74-0,55-4D 400 0,55 1,6 2,5 750 1360 62 60 S-Vent 160x74-0,75-2D 400 0,75 1,8 2,5 1540 2820 68 60 S-Vent 180x74-0,55-4D 400 0,55 1,6 2,5 1030 1360 64 60 S-Vent 180x74-1,1-2D 400 1,1 2,6 3,2 1950 2800 70 60 S-Vent 200x93-0,55-4D 400 0,55 1,6 2,5 1615 1360 67 60 S-Vent 200x93-1,1-2D 400 1,1 2,6 3,2 1900 2800 73 60 S-Vent 225x103-1,1-4D 400 1,1 2,8 3,2 2125 1420 72 60 S-Vent 225x103-2,2-2D 400 2,2 4,7 6,3 3350 2865 75 60 S-Vent 240x114-2,2-4D 400 2,2 5,1 6,3 2930 1420 74 60 S-Vent 240x114-3,0-2D 400 3,0 6,1 8,0 4350 2870 78 60 S-Vent 250x127-1,5-6D 400 1,5 4,2 6,3 2415 940 68 60 S-Vent 250x127-2,2-4D 400 2,2 5,1 6,3 3720 1420 78 60 S-Vent 250x127-5,5-2D 400 5,5 10,7 12,5 4820 2850 81 60 S-Vent 280x127-1,5-6D 400 1,5 4,2 6,3 3450 940 69 60 S-Vent 280x127-2,2-4D 400 2,2 5,1 6,3 4395 1420 75 60 S-Vent 280x127-5,5-2D 400 5,5 10,7 12,5 6330 2850 81 60 S-Vent 315x143-2,2-6D 400 2,2 5,6 6,3 4375 940 70 60 S-Vent 315x143-4,0-4D 400 4,0 8,7 10,0 6530 1410 79 60 S-Vent 355x143-2,2-6D 400 2,2 5,6 6,3 5090 940 71 60 S-Vent 355x143-4,0-4D 400 4,0 8,7 10,0 8150 1410 79 60 S-Vent 400x183-1,5-8D 400 1,5 4,2 6,3 6545 700 62 60 S-Vent 400x183-2,2-6D 400 2,2 5,8 6,3 8100 940 73 60 S-Vent 400x183-5,5-4D 400 5,5 11,0 16,0 10175 1430 80 60 S-Vent 450x203-3,0-8D 400 3,0 7,8 10,0 10230 700 70 60 S-Vent 450x203-4,0-6D 400 4,0 9,1 12,5 11150 950 76 60 S-Vent 450x203-11,0-4D 400 11,0 24,0 31,5 19000 1450 84 60 S-Vent 500x229-5,5-8D 400 5,5 14,8 16,0 11550 700 72 60 S-Vent 500x229-7,5-6D 400 7,5 17,0 20,0 14960 955 78 60 S-Vent 500x229-11,0-4D 400 11,0 24,0 31,5 17250 1450 85 60 FRZ-SV 140 SG-SV 140 FRZ-SV 160 SG-SV 160 SI-G 8 SI-F 8 FRZ-SV 180 SG-SV 180 FRZ-SV 200 SG-SV 200 FRZ-SV 225 SG-SV 225 FRZ-SV 240 SG-SV 240 SI-G 16 SI-F 16 FRZ-SV 250 SG-SV 250 FRZ-SV 280 SG-SV 280 FRZ-SV 315 SG-SV 315 SI-G 26 SI-F 26 FRZ-SV 355 SG-SV 355 SI-G 35 SI-F 35 FRZ-SV 400 SG-SV 400 SI-G 50 SI-F 50 FRZ-SV 450 SG-SV 450 SI-G 75 SI-F 75 FRZ-SV 500 SG-SV 500 Allowable deviation of power mains voltage is ±10 % of the rated voltage. 4

www.blaubergventilatoren.de TwinFresh Comfo RB(1)-50(-2) S-Vent 140x74-0.37-2D S-Vent 140x74-0.25-4D S-Vent 160x74-0.75-2D S-Vent 160x74-0.55-4D 0.75 kw 0.37 kw 0.25 kw 0.55 kw 1 2 S-Vent 180x74-1.1-2D S-Vent 180x74-0.55-4D S-Vent 200x93-1.1-2D S-Vent 200x93-0.55-4D 1.1 kw 1.1 kw 0.55 kw 0.55 kw 3 4 S-Vent 225x103-2.2-2D S-Vent 225x103-1.5-4D 2.2 kw S-Vent 240x114-2.2-4D S-Vent 240x114-3.0-2D 1.1 kw 5 6 S-Vent 250x127-2.2-4D S-Vent 250x127-1.5-6D S-Vent 250x127-5.5-2D 2.2 kw 5.5 kw 1.5 kw 7 8 Abb. 1. Aerodynamische Eigenschaften der Ventilatoren S-Vent 280x127-2.2-4D S-Vent 280x127-1.5-6D 2.2 kw S-Vent 280x127-5.5-2D 5.5 kw 5

Helix / S-Vent www.blaubergventilatoren.de S-Vent 280x127-2.2-4D S-Vent 280x127-1.5-6D S-Vent 280x127-5.5-2D 5.5 kw 2.2 kw 1.5 kw 9 10 S-Vent 315x143-4.0-4D S-Vent 315x143-2.2-6D S-Vent 355x143-4.0-4D S-Vent 355x143-2.2-6D 4.0 kw 4.0 kw 2.2 kw 11 12 S-Vent 400x183-2.2-6D S-Vent 400x183-1.5-8D S-Vent 400x183-5.5-4D 5.5 kw 2.2 kw 1.5 kw 13 14 S-Vent 450x203-4.0-6D S-Vent 450x203-3.0-8D S-Vent 450x203-11.0-4D 11.0 kw 4.0 kw 3.0 kw 6 15 16 Abb. 1. Aerodynamische Eigenschaften der Ventilatoren S-Vent 500x229-7.5-6D S-Vent 500x229-5.5-8D S-Vent 500x229-11.0-4D 7.5 kw 11.0 kw

www.blaubergventilatoren.de 14 Air capacity [m 15 TwinFresh Comfo 16 RB(1)-50(-2) 3 /h] Air cap S-Vent 450x203-4.0-6D S-Vent 450x203-3.0-8D S-Vent 450x203-11.0-4D S-Vent 500x229-7.5-6D S-Vent 500x229-5.5-8D S-Vent 500x22 4.0 kw 11.0 kw 7.5 kw 3.0 kw 5.5 kw 17 16 Air capacity [m 18 3 /h] Air cap S-Vent 500x229-7.5-6D S-Vent 500x229-5.5-8D S-Vent 500x229-11.0-4D 7.5 kw 11.0 kw Helix 5.5 kw 18 19 Fig. 1. Aerodynamic fan characteristics Helix Possible S-Vent casing rotation options (view on intake side) right impeller rotation direction left impeller rotation direction 19 R R L L R R L L R R L L R R L L Fig. 2. S-Vent overall dimensions and casing rotation options 7

Helix / S-Vent www.blaubergventilatoren.de Table 2 Fan model Overall dimensions [mm] D d d1 B H H1 H2 H3 L L1 L2 P M l G K S S-Vent 140x74-0.25-4D 140 8 10 242 323 125 92 144 309 125 95 124 220 234 18 253 80 9,3 S-Vent 140x74-0.37-2D 140 8 10 242 323 125 92 144 309 125 95 124 220 234 18 253 80 9,3 S-Vent 160x74-0.55-4D 160 8 10 277 373 134 106 173 356 134 104 141 220 260 17 252 90 12,7 S-Vent 160x74-0.75-2D 160 8 10 277 373 134 106 173 356 134 104 141 220 260 17 252 90 13,0 S-Vent 180x74-0.55-4D 180 10 10 311 414 143 120 193 365 143 114 146 270 270 22 314 90 13,5 S-Vent 180x74-1.1-2D 180 10 10 311 414 143 120 193 365 143 114 146 270 270 22 314 90 14,5 S-Vent 200x93-0.55-4D 200 10 10 345 436 160 134 193 380 160 129 158 270 284 24 315 90 15,2 S-Vent 200x93-1.1-2D 200 10 10 345 436 160 134 193 380 160 129 158 270 284 24 315 90 16,2 S-Vent 225x103-1.1-4D 225 10 12 388 507 178 151 232 432 172 141 174 275 316 27 330 100 21,2 S-Vent 225x103-2.2-2D 225 10 12 388 507 178 151 232 432 172 141 174 275 316 27 330 100 24,2 S-Vent 240x114-2.2-4D 240 10 12 414 568 186 161 282 461 186 156 195 275 362 27 330 125 30,5 S-Vent 240x114-3.0-2D 240 10 12 414 568 186 161 282 461 186 156 195 275 362 27 330 125 31,4 S-Vent 250x127-1.5-6D 250 10 12 431 594 202 168 292 473 202 166 206 300 373 27 355 125 33,0 S-Vent 250x127-2.2-4D 250 10 12 431 594 202 168 292 473 202 166 206 300 373 27 355 125 32,2 S-Vent 250x127-5.5-2D 250 10 12 431 614 202 168 312 517 202 166 213 300 397 27 355 140 40,0 S-Vent 280x127-1.5-6D 280 10 12 483 626 225 189 292 503 231 196 243 300 410 27 355 125 35,1 S-Vent 280x127-2.2-4D 280 10 12 483 626 225 189 292 503 231 196 243 300 410 27 355 125 34,2 S-Vent 280x127-5.5-2D 280 10 12 483 646 225 189 312 545 231 196 243 300 427 27 355 140 42,4 S-Vent 315x143-2.2-6D 315 10 15 543 731 250 213 353 568 255 216 268 350 452 27 405 140 46,8 S-Vent 315x143-4.0-4D 315 10 15 543 731 250 213 353 568 255 216 268 350 452 27 405 140 49,8 S-Vent 355x143-2.2-6D 355 10 15 611 817 275 241 403 566 255 214 253 350 442 32 405 140 49,0 S-Vent 355x143-4.0-4D 355 10 15 611 817 275 241 403 566 255 214 253 350 442 32 405 140 51,0 S-Vent 400x183-1.5-8D 400 10 15 689 870 310 272 403 619 310 268 313 400 497 27 455 140 57,1 S-Vent 400x183-2.2-6D 400 10 15 689 870 310 272 403 619 310 268 313 400 497 27 455 140 54,1 S-Vent 400x183-5.5-4D 400 10 15 689 882 310 272 414 662 330 289 341 400 525 27 455 140 69,5 S-Vent 450x203-3.0-8D 450 10 15 774 985 345 306 464 690 352 315 351 450 550 42 530 140 77,8 S-Vent 450x203-4.0-6D 450 10 15 774 985 345 306 464 690 352 315 351 450 550 42 530 140 76,5 S-Vent 450x203-11.0-4D 450 10 15 774 1005 345 306 484 722 352 315 371 450 608 42 530 178 105,0 S-Vent 500x229-5.5-8D 500 11 15 860 1115 390 341 534 761 401 353 408 500 645 42 580 178 85,0 S-Vent 500x229-7.5-6D 500 11 15 860 1115 390 341 534 761 401 353 408 500 645 42 580 178 86,0 S-Vent 500x229-11.0-4 500 11 15 860 1115 390 341 534 761 401 353 408 500 645 42 580 178 107,0 Weight [kg] Table 3 Fan type Supply voltage, 50 Hz [V] Power consumption[kw] Current consumption [A] Automatic switch trip current [A] Air capacity [m 3 /h] RPM [min-1] Noise level, 3 m [dba] Max. transported air temperature [ C] Helix 140x60 2E 230 148 0,64 1,6 515 2820 68-25 +45 Rubber vibration isolator Accessories compatibility Spring-loaded vibration isolators Helix 160x62 2E 230 264 1,17 1,6 560 2630 70-25 +50 FRZ-H 160 SG-H 160 Helix 160x90 2E 230 258 1,16 2,5 640 2745 70-25 +45 SI-G 8 SI-F 8 Helix 180x92 4E 230 160 0,70 1,6 800 1465 62-25 +45 FRZ-H 180 SG-H 180 Helix 200x80 4E 230 125 0,55 1,6 730 1430 63-25 +45 Helix 200x102 4E 230 280 1,25 1,6 1350 1475 65-25 +40 Helix 225x102 4E 230 395 1,98 2,5 1480 1330 69-40 +70 Helix 250x102 4E 230 810 3,65 5,0 2000 1330 63-40 +70 Helix 250x140 4E 230 570 2,48 3,15 2000 1310 60-40 +70 SI-G 14 SI-F 14 Flange Grille FRZ-H 140 SG-H 140 FRZ-H 200 SG-H 200 FRZ-H 200 /FRZ-H 225 SG-H 200 / SG-H 225 FRZ-H 250 SG-H 250 Allowable deviation of power mains voltage is ±10 % of the rated voltage. 8

www.blaubergventilatoren.de TwinFresh Comfo RB(1)-50(-2) Table 4 Fan model Overall dimensions [mm] ØD B H H1 H2 L L1 L2 P M Ød Helix 140x60 2E 140 243 287 125 93 85 107 75 116 150 9 3,5 Helix 160x62 2E 160 277 324 136 106 89 112 82 122 200 9 4,6 Helix 160x90 2E 160 277 324 136 106 136 158 127 168 200 9 5,5 Helix 180x92 4E 180 311 360 150 120 145 166 137 181 230 9 7,1 Helix 200x80 4E 200 345 398 165 134 116 140 108 150 240 9 7,5 Helix 200x102 4E 200 345 398 165 134 152 175 143 185 240 9 8,0 Helix 225x102 4E 225 365 441 210 171 145 170 137 178 250 11 11,9 Helix 250x102 4E 250 410 485 230 191 165 190 157 198 270 11 16,3 Helix 250x140 4E 250 410 485 230 191 205 230 197 238 270 11 16,3 Weight [kg] Possible Helix casing rotation options (view on intake side) Fig. 3. Helix overall dimensions and casing rotation options 9

Helix / S-Vent www.blaubergventilatoren.de SAFETY REQUIREMENTS Installation and operation of the fan shall be performed in accordance with the present user s manual as well as the provisions of all the applicable local and national construction, electrical and technical codes and standards. Mounting and electric connection of the fan are allowed only by duly qualified electricians in compliance with valid rated norms. The fan must be grounded! Check the fan for any visible damages of impeller and casing prior to connecting the fan to power mains. The fan casing must not contain any foreign objects which can damage the impeller blades. Otherwise please contact the fan Seller. Misuse of the fan or, any unauthorized design alteration or modifications are not allowed. The fan is classified as a class I electric appliance. WARNING! DISCONNECT THE FAN FROM POWER MAINS PRIOR TO MAINTENANCE AND SERVICING OPERATIONS. MAKE SURE THAT THE IMPELLER HAS COME TO A FULL STOP. DO NOT! THE FAN MUST NOT BE OPERATED OUTSIDE THE TEMPERATURE RANGE STATED IN THE USER S MANUAL OR IN AGGRESSIVE OR EXPLOSIVE ENVIRONMENTS. DESIGN AND OPERATING LOGIC Casing Casing Motor Terminal block Motor Fixing bracket Fixing bracket Impeller Impeller Helix S-Vent Fig. 4. Design and operation logic The S-Vent fan consists of a metal casing, a motor and an air intake ring connected to the casing through the flange. The impeller is fixed to the drive shaft. The fixing bracket is attached to the motor bottom. The S-Vent fans are available in right-handed and left-handed modifications. The impeller of the right-handed models has clockwise rotation and the impeller of the left-handed models has counter-clockwise rotation, view on air intake side, Fig. 2. The Helix fan consists of a metal casing, an impeller and a motor screwed to a flange. The terminal box with the operating capacitor is fixed on the casing top. Use fixing brackets for the fan mounting. 10

www.blaubergventilatoren.de TwinFresh Comfo RB(1)-50(-2) MOUNTING AND SET-UP After the fan unpacking, prior to the mounting: Read carefully the user s manual and the mounting, start-up, operating and servicing guidelines. Check the fan for any transport damages. Fulfil the safety requirements during the fan set-up and operation. Mounting of the fan as follows: Make sure that the fan is disconnected from power mains, Fig. 5.1, 6.1; Mark the fastening holes for mounting of the fixing bracket on a load-bearing surface, Fig. 5.2, 6.2; Drill the holes and fix the fixing bracket using matching fasteners, i.e. dowels. Install the vibration isolators SI-G or SI-F (option) if required, Fig. 5.3, 6.3; Ground the fan, Fig. 5.4, 6.4. Connect the air ducts to the fan. Install the FRZ-H, FRZ-SV flange (option), Fig. 5.5, 6.5, Table 1, 3 or the SG-H, SG-SV protecting grille, Fig. 5.6, 6.6, Table 1, 3 on the intake side. 1. 2. S1 PE 3. 4. 5. 6. Fig. 5. S-Vent fan mounting sequence 11

Helix / S-Vent www.blaubergventilatoren.de 1. 2. S1 3. 4. 5. 6. Fig. 6. S-Vent fan mounting sequence CONNECTION TO POWER MAINS THE FAN MUST BE CONNECTED TO POWER MAINS BY A QUALIFIED ELECTRICIAN AFTER CAREFUL READING OF THE USER S MANUAL. THE FAN IS RATED FOR CONNECTION TO ALTERNATING CURRENT POWER SUPPLY WITH VOLTAGE COMPLIANT TO THE TECHNICAL DATA TABLE. MAKE SURE THE CABLE IS NOT PRESSED ANYWHERE. THE RATED ELECTRICAL PARAMETERS OF THE FAN ARE STATED ON THE RATING PLATE. ANY INTERNAL CONNECTION MODIFICATIONS ARE NOT ALLOWED AND RESULT IN VOID WARRANTY. Helix fan is rated for connection to single-phase ac 230 V / 50 Hz power mains. S-Vent fan is rated for connection to three-phase ac 400 V / 50 Hz power mains. For electric connection use insulated, durable and thermal-resistant cords (cables, wires). The house cabling system must be equipped with an automatic switch at the external input. Install the external automatic switch to enable quick access to it in case urgent disconnection of the fan is required. Connect the fan to power mains through the automatic switch. The contact gap on all poles at least 3 mm. The recommended cable cross section is stated in the table 5. While selecting the cable type consider the maximum allowable cable heating temperature that depends on the wire type, insulation, length and layout way (open wire mounting, channel type or wall-mounted). 12

www.blaubergventilatoren.de TwinFresh Comfo RB(1)-50(-2) Table 5 Fan model Minimum cable cross section [mm 2 Ї All Helix models 1,5 S-Vent 140... S-Vent 180 1,5 S-Vent 200... S-Vent 400 2,5 S-Vent 450... S-Vent 500 4 Connection of -Vent is as follows, Fig. 7: Make sure that power cable is disconnected to power mains, Fig. 7.1; Remove the lid of the terminal box located on the motor casing, Fig. 7.2. Route the power cable wires through the electric lead-in on the terminal box, then strip the wires for 7 8 mm, Fig. 7.3. Connect the cables to the terminal box in compliance with the wiring diagram. The three-phase motors must be star-connected considering the terminal marking. For doing so, insert the wires into the respective terminals against insulation stop and fix those with the screws. Cover the terminal box with the lead, Fig. 7.4. 1. 2. S1 PE 3. 4. Fig. 7. Connection of S-Vent to power mains, Fig. 7: Air flow direction in the system must match the pointer in the fan casing. To check the correct impeller rotation start the fan for a short time. If the impeller rotation is wrong, switch over any two phases on the motor terminals by changing the respective wires in the terminal block. 13

Helix / S-Vent www.blaubergventilatoren.de Connection of Helix fan is as follows, Fig. 8: Make sure that power cable is disconnected to power mains, Fig. 8.1. Remove the lid of the terminal box located on the motor casing, Fig. 8.2. Route the power cable wires through the cable gland on the terminal box, then strip the wires for 7 8 mm, Fig. 8.3. Connect the cables to the terminal box in compliance with the wiring diagram and considering the terminal marking. Connection of the single-phase motors is shown in Fig. 8.3 and 9.1. Connection of the single-phase motors with external thermal contacts is shown in Fig. 9.2. To connect the cable to power mains, insert the wires into the respective terminals against insulation stop in the metal part and fix those with the screws. Cover the terminal box with the lead, Fig. 8.4. Connection example of Helix with external thermal protection and a magnetic starter is shown in Fig. 9.3. The terminals TW1, TW2 are the electrical leads of the normally closed contact of the motor overheating protection. Connect the contact in series to the power circuit of the magnetic starter coil that starts the motor. In case of the motor overheating the contact opens and the motor stops. Im Falle der Motorüberhitzung wird der Kontakt getrennt und der Motor gestoppt. 1. 2. S1 3. 4. Fig. 8. Connection of Helix to power mains 14

www.blaubergventilatoren.de TwinFresh Comfo RB(1)-50(-2) 1. Helix 3. L ~230V 50Hz N PE QF L N X1 QF - automatic switch (not included into the delivery set); X1 - terminal block Helix with a magnetic starter and a thermal contact L ~230V 50Hz N PE S1 start S2 stop KM1 1 2 3 4 QF - automatic switch (not included into the delivery set); KM1 - magnetic starter (not included into the delivery set); S1, S2 - control buttons (not included into the delivery set); X1 - terminal block L N TW1 TW2 X1 1 2 3 4 5 6 2. Helix with a thermal contact ~400V 50Hz QF L ~230V 50Hz N PE L1 L2 L3 PE TW1 TW2 QF L1 L2 L3 L N TW1 TW2 4. S-Vent L1 L2 L3 X1 X1 1 2 3 4 5 6 1 2 3 4 5 6 7 U1 V1 W1 U2 V2 W2 PE QF - automatic switch (not included into the delivery set); X1 - terminal block Fig. 9. Fan wiring diagrams MAINTENANCE Disconnect the fan from power mains prior to maintenance and servicing operations and make sure that the moving parts have come to a full stop. The fan maintenance means regular cleaning of the fan surfaces of dust and dirt, Fig. 10. Clean the impeller blades thoroughly once in 6 months as follows: Cut off power supply to the fan; Provide access to the fan impeller: for S-Vent fan: remove the screws and take off the ring; for Helix fan: remove the screws and pull out the impeller-motor unit; Clean the impeller blades using a dry brush or compressed air; In case of high soiling wet cleaning is recommended. Clean the impeller blades with a soft cloth wetted in a neutral detergent solution. Avoid liquid dripping on the motor! Perform all the operations in the reverse order after cleaning. 15

Helix / S-Vent www.blaubergventilatoren.de S-Vent 1. 2. S1 PE Helix 1. 2. S1 Maintenance instructions: Fig. 10. Fan maintenance Perform regular maintenance of the fan to ensure its reliable, safe and efficient operation. General maintenance includes: Perform daily maintenance; Maintenance after each 1000 operating hours: Perform all the above maintenance after each 1000 operation hours; Perform overhaul repairs after 20 000 operating hours. All the maintenance works must be carried out according to the schedule above, no matter of the fan operating condition. Daily fan maintenance must be performed by a mechanical operator. Current repair operations and overhaul repair operations must be performed by a mechanical operator and an electrician responsible for the equipment repair and operation. Daily maintenance of the fan includes: Check bolt tightening; Check the ground fixation reliability; Check the fan for no noise. Maintenance after each 1000 operating hours: Perform all the daily maintenance operations; Troubleshoot any faults in bolt or welded connections; Checking the clearance between the impeller and the capacitor. Current repair: Perform all the above maintenance operations after each 1000 operating hours; Clean the casing and the impeller of dirt. General overhaul: Disconnect the air ducts; Disassemble the fan components; Assemble the fan units of new or repair parts; Check the bearing grease and perform adjustment and test running. 16

www.blaubergventilatoren.de TwinFresh Comfo RB(1)-50(-2) TROUBLESHOOTING Table 6. Troubles and Troubleshooting Problem Possible reasons Fault handling The fan does not start. Automatic circuit breaker tripping during the fan start. Noise, vibration No power supply. Motor jam. Overcurrent as a result of short circuit. The fan impeller is soiled. Loose screw tightening. Resonance with a mounting construction. Make sure of correct power supply, otherwise troubleshoot a connection error. Turn the fan off. Troubleshoot the motor jamming. Clean the fan impeller blades. Start the fan. Turn the fan off. Contact the fan Seller. Clean the fan impeller. Check the screw connection and tighten the screws if required. Use the suitable recommended SI-G and SI-F vibration isolators. STORAGE AND TRANSPORTATION RULES Store the fan in the manufacturer s original packing box in a dry ventilated premise at the temperatures from +5 C up to + 40 C. Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion, insulation and sealing deformation. Use hoist machinery for handling and storage operations to prevent the fan damage. Fulfil the handling requirements applicable for the applicable freight type. Transportation with any vehicle type is allowed provided that the fan is protected against mechanical and weather damage. Avoid any mechanical shocks and strokes during handling operations. MANUFACTURER S WARRANTY The manufacturer hereby warrants normal operation of the fan over the period of 24 months from the retail sale date provided the user s observance of the transportation, storage, installation and operation regulations. In case of no confirmation of sales date the warranty period is calculated from the production date. In case of failures in the fan operation during the warranty period the manufacturer will accept claims and complaints from a customer only after receiving a technical protocol with a fault description. The fan damage as a result of unauthorized modifications in the electric circuit diagram is not a warranty case. Both warranty and post-warranty services are carried out at the manufacturing facility. In case of warranty claim please provide the filled guarantee card with the trade company stamp and the user manual. IN CASE OF WARRANTY CLAIM PLEASE SUBMIT THE USER S MANUAL AND THE FILLED CONNECTION CERTIFICATE. THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY DAMAGES RESULTING FROM THE FAN MISUSE OR GROSS MECHANICAL INTERFERENCE. FOLLOW THE USER S MANUAL REQUIREMENTS TO ENSURE NON-STOP AND TROUBLE-FREE OPERATION OF THE FAN. 17

Helix / S-Vent www.blaubergventilatoren.de ACCEPTANCE CERTIFICATE The centrifugal fan in spiral casing is recognizes as serviceable. The product complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility. We hereby declare that the product complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/ EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. Approval mark Manufacturing date Sold by Company name and stamp Sales date CONNECTION CERTIFICATE The centrifugal fan in spiral casing Helix/S-Vent is connected to power mains in compliance with this operation manual requirements by the professional: Company name Name of the installation expert Date Signature WARRANTY CARD MANUFACTURING DATE SELLER SALES DATE REPRESENTATIVE IN EU BLAUBERG Ventilatoren GmbH Aidenbachstr. 52 D-81379 München, Germany 18

www.blaubergventilatoren.de TwinFresh Comfo RB(1)-50(-2) 19

www.blaubergventilatoren.de Helix_S-Vent / v.3(8) / EN