EW171 Series Woltman Bulk Water Meters DN FOR COLD AND WARM POTABLE WATER APPLICATIONS

Similar documents
EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM. Overview. Application PRODUCT DATA

aquaconcept Cold water

ULTRAFLOW 54 DN

Applications. Features & Benefits ULTRASONIC WATER METER

Metering systems 0670EN March 2017 Volumetric thermal energy meters for use in a boiler room GE552-1 series

meter SKU-03 (calculator and flow sensor) Fig.2. Calculator of the heat meter SKU-03

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

aquaconcept Cold water

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

M7100 Pressure Transducer

13-1. Temperature Regulator

Disc Type Steam Trap TSD-42

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark Phone: Internet: Fax:

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

Supply air unit VEKA Installation & Maintenance

MFP14 Automatic pumps. for condensate and other industrial fluids

Synco living. Train the Trainer. Mounting Safety Devices. August 2007 Page 1/11 Train the Trainer - August 2007

SonoSelect and SonoSafe Energy Meters

Water Safety Shut-Off Valve HON 790. Product information. serving the gas industry worldwide

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

Fan heater SWT Ceiling mounted fan heater with water heat

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

~256. Ventilator. Float valve. Plugged end (INLET) Straight connection DN kpa: 1.20 l/s (instantaneous value)

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

FlexFilter EX A state of the art filter system to meet your current and future needs

2500 Automatic Tank Gauge

Bead Roller Operating, Servicing, and Safety Instruction Manual

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

MFP14 Automatic pumps for condensate and other industrial fluids

The A-series Eletta Flow Monitor with local indication and analog output

EU-Type Examination Certificate

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

Grain Flow. Grain Flow. Efficient Reliable Accurate. Automatic In-Bin Continuous Flow Grain Drying. David Manufacturing Co.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Section B Field Instruments

1592P01. for liquids in piping DN

COMFORT IP: Room Control Unit Radio with Display

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

600A, Configurable. A powerful dust collector, for suction over long horizontal and vertical distance

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Watch Movement Specification and Drawing CHRONOGRAPH. Cal. YM62A. Movement Size. Casing Diameter. Ø 27.0mm. Height. 3.7mm. Battery Life.

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

108A OTP1800. Grid Support. General Description

VersaFlow Mag 2000 FL Electromagnetic Flow Sensor Technical Datasheet. Specification. Solution with high-tech ceramics. Highlights.

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Chapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING

Enraf Servo Gauge 854 XTG

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

Spare parts list GS GS GS 315

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

HCM 200D ZONING MANAGER FEATURES GENERAL PRODUCT DATA

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

Operator s Manual. IP-100 Immersion Probe Cooler

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

T6984F,G Electronic Floating Control Thermostats

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Product Training Module: Digital Pressure Sensors with CANopen Model DPS

AS950 REFRIGERATED SAMPLERS

TECHNICAL. Series 18. Pump Packages

Level Measurement Continuous level measurement Ultrasonic transmitters

Installation Instructions Part No , Part No Part No

MSL A B A BK3 OS P AB

AIR HANDLER SPECIFICATION

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

PRODUCT CONFORMITY CERTIFICATE

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

HUMIDIFIER EQQA, EQQZ

DATASHEET HIGH VOLUME LONG RANGE FOAM MONITOR GPM

Direct reading flowmeters type RM

MBM BC-10 Business Card Cutter

Overload relays. General descriptions. Configuration of the front

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

CAP SERIES SEWAGE AND WASTE WATER PUMPS

MAGNA3 More than A pump

Ultrasonic Level Measurement nivopuls FDU 10 S

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Cold Soak Filtration Test (CSFT) of Biodiesel. ASTM D IP PM EA - CEN N CGSB 3.0 No Range

Rules for Intruder Alarm Systems

MAGNA3 MAGNA3. The full Grundfos product range covers all building application areas:

Weigh In Motion (WIM) Wheel Impact Load Detector (WILD)

manifold, for radiators

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

LE 210 and LU 210 Series Load Measuring Pins

Transcription:

EW171 Series Woltman Bulk Water Meters DN50 300 FOR COLD AND WARM POTABLE WATER APPLICATIONS CONTENTS PRODUCT DATA EW171, DN50 Contents... 1 General... 2 Application... 2 Features... 2 Design... 2 Materials... 2 Approvals... 2 Technical Details... 3 Specifications... 3 Flow Data... 3 Sizing... 3 Function... 3 Counter... 4 Flow Sensor... 4 Installation... 4 Remote Readout... 4 Identification... 4 Counter... 4 Flow Sensor... 4 Front Panel Contents... 4 Dimensions... 5 Ordering Details... 6 Ordering Information... 6 Scope of Delivery... 6 Accessories... 6 Diagrams... 7 Accuracy... 7 Flow Diagram... 7 EW171, DN400 Honeywell All rights reserved 1 EN0H-0458GE25 R1014

GENERAL Application Honeywell EW171 Series Woltman water meters are used for volume measurement of cold or warm water in potable water networks. They are available for cold water up to 30 C (EW1710) or for warm water up to 130 C (EW1711). They have a mechanical counter with rollers and dials and can be equipped with clip-on modules for remote readout applications. Clip-on modules are available for wired M-Bus, pulse out and RF (OMS, 848MHz). The clip-on modules are retrofittable. Features Suitable for horizontal and vertical installation Low pressure loss Rugged design for longterm accuracy Retrofittable clip-on modules for remote readout Design EW171 Series water meters consist of: Mechanical counter Woltman WP type mechanical flow sensor Housing with flanges to PN16 Optional clip-on module for remote readout Materials Counter housing and lid made of dark plastic Flow sensor housing made of cast iron, painted blue (cold water version) or red (warm water version) Approvals EW171 Series bulk water meters have MID approval under approval number SK08-MI001-SMU002 (for cold water) and SK10-MI001-SMU013 (for warm water). Fig. 1. EW171 Series main components Table 1. EW171 Series main components Number Component 1 Counter lid 2 Roller counter 3 Decimal place dials 4 Counter housing 5 Inlet 6 Flow sensor housing 7 Outlet EN0H-0458GE25 R1014 2 Honeywell All rights reserved

TECHNICAL DETAILS Specifications Sizes Medium Temperature class Medium temperature Ambient temperature Water pressure class Op. pressure range Pressure loss class Protection class Environmental class Mechanical class DN50 300 Q3 40 1,600 (EW1710) Q3 25 1,000 (EW1711) Potable water EW1710: T30, T50 EW1711: T130 EW1710: 0.1 30 C EW1711: 0.1 130 C 5 55 C MAP16 (max. 16bar) 0.3 16bar P16 (max. 16kPa) IP66 B M1 Electromagnetic class Measuring process E1 Mechanical counter with Woltman WP type flow measurement Display Six-digit roller counter with three dials for decimal places Display unit m³ Display range DN50 125: 10 6 m³ DN150 300: 10 7 m³ Increments DN50 125: 0.0005m³ DN150 250: 0.005m³ DN300: 0.05m³ Acceptable error ±5% (Q 1 Q Q 2) ±2% (Q 2 Q Q 4 for 0.1 T 30 C ±3% (Q 2 Q Q 4 for T>30 C Installation position H, V (horizontal, vertical) Flow Data Table 2. Flow rates EW1710, for cold water applications DN size 50 65 80 100 125 150 200 250 300 Flow rates according to MID Minimum (Q 1 ) m³/h 0.4 0.5 0.63 0.8 1.6 2 5 10 16 Transition (Q 2 ) m³/h 0.64 0.8 1 1.3 2.5 3.2 8 16 26 Permanent (Q 3 ) m³/h 40 63 100 160 250 400 630 1,000 1,600 Overload (Q 4 ) m³/h 50 78.8 125 200 313 500 788 1,250 2,000 Dynamic range Q 3 /Q 1 R100 R125 R160 R200 R160 R200 R125 R100 R100 Additional flow data Starting flow m³/h 0.15 0.2 0.25 0.25 0.5 1.0 1.5 3 8 Table 3. Flow rates EW1711, for warm water applications DN size 50 65 80 100 125 150 200 250 300 Flow rates according to MID Minimum (Q 1 ) m³/h 0.63 1 1.58 2.5 4 6.3 10 25 40 Transition (Q 2 ) m³/h 1 1.6 2.5 4 6.4 10 16 40 64 Permanent (Q 3 ) m³/h 25 40 63 100 160 250 400 630 1,000 Overload (Q 4 ) m³/h 31.25 50 78.8 125 200 313 500 788 1,250 Dynamic range Q 3 /Q 1 R40 R40 R40 R40 R40 R40 R40 R25 R25 Additional flow data Starting flow m³/h 0.25 0.3 0.35 0.6 1.1 2 4 8 15 Sizing EW171 Series water meters must be selected in such a way that typical system flow rates are between transition (Q 2 ) and permanent flow rate (Q 3 ) The flow rate may not drop below minimum (Q 1 ) or exceed overload flow rate (Q 4 ) at any time Honeywell All rights reserved 3 EN0H-0458GE25 R1014

Function Counter The counter contains a five-digit roller counter for values of whole m³ and dials for tenth, hundredth and thousandth parts of m³. It is flanged to the flow sensor housing. Displayed value is cumulative (total) flow through the meter. Flow Sensor The Woltman technology of the flow sensor combines high measuring accuracy with long term stability and the capability of measuring high volumes at low pressure drop. The Woltman wheel is connected to the counter by a shaft and a magnetic coupling. Installation Calming legs are not required unless bends, pumps or self-acting valves are placed before or after the meter. In such cases calming legs of straight pipe with a minimum length of 6 x DN before and 2 x DN after the meter are required All sizes may be installed in either horizontal or vertical position The meter must be installed in such a way that the counter faces up or sideways. It must not be installed in such a way that the counter faces downwards Avoid installation at highest point of system or system part as air may be trapped in meter During measurement meter must be completely filled with water Remote Readout EW171 Series water meters can be fitted with clip-on modules for remote readout applications. The clip-on modules are retrofittable and are attached by means of a standardised design which is identical for all sizes DN50 300. Mounting of the modules does not affect approval of the meter. The following modules are available: Wired M-Bus, according to EN13757-3 Pulse output, open collector RF, according to OMS, 848MHz Identification Counter Six-digit roller counter with three dials for decimal places Marked with Honeywell logo, Honeywell OS-Number, approval number and key technical data according to requirements of MID Set into black plastic collar with lid Flow Sensor Flanged flow sensor housing painted blue (EW1710) or red (EW1711) with DN size and flow arrow embossed on side Front Panel Contents Fig. 2. Frontplate contents of EW1710AC5000 Table 4. EW171 Series frontpanel elements Number Element 1 Honeywell logomark 2 OS-Number 3 Roller counter 4 Unit 5 0.1 x unit dial 6 0.01 x unit dial 7 0.001 x unit dial 8 Differential pressure at nominal flow 9 Maximum static pressure 10 Temperature class 11 Permanent flow Q 3 12 Dynamic range / flow profile resistance class 13 Approval number 14 CE mark EN0H-0458GE25 R1014 4 Honeywell All rights reserved

Dimensions DN Size Length L Fig. 3. Dimensions Table 5. Dimensions EW171 Series Height H Height H1 Height h Diameter D Weight 50 200 187 287 72 165 10kg 65 200 197 297 83 185 11kg 80 225 219 239 95 200 14kg 100 250 229 349 105 220 16kg 125 250 257 377 120 250 18kg 150 300 357 582 135 285 40kg 200 350 382 607 160 340 51kg 250 450 427 652 193 400 75kg 300 500 497 722 230 460 103kg NOTE: All dimensions in mm unless stated otherwise Height H1 = space required for removal of measuring insert Honeywell All rights reserved 5 EN0H-0458GE25 R1014

ORDERING DETAILS Ordering Information Table 6. OS-Nos. (OS=Order Specification) Item DN size Permanent flow Q 3 Length OS-Number EW1710A Bulk water meters for cold water 50 40m³/h 200mm EW1710AC5000 65 63m³/h 200mm EW1710AC5600 80 100m³/h 225mm EW1710AC6500 100 160m³/h 250mm EW1710AC7300 125 250m³/h 250mm EW1710AC8100 150 400m³/h 300mm EW1710AC8500 200 630m³/h 350mm EW1710AC8900 250 1,000m³/h 450mm EW1710AC9100 300 1,600m³/h 500mm EW1710AC9200 EW1711A Bulk water meters for warm water 50 25m³/h 200mm EW1711AC5000 65 40m³/h 200mm EW1711AC5600 80 63m³/h 225mm EW1711AC6500 100 100m³/h 250mm EW1711AC7300 125 160m³/h 250mm EW1711AC8100 150 250m³/h 300mm EW1711AC8500 200 400m³/h 350mm EW1711AC8900 250 630m³/h 450mm EW1711AC9100 300 1,000m³/h 500mm EW1711AC9200 Scope of Delivery EW170 Series water meter Installation and setup instructions Accessories Clip-on modules, suitable for all EW171 Wired M-Bus Pulse output RF EW171C-MBUS EW171C-PO EW171C-RF EN0H-0458GE25 R1014 6 Honeywell All rights reserved

DIAGRAMS Accuracy Fig. 4. Accuracy chart EW171 Series Flow Diagram Fig. 5. Pressure drop diagram EW171 Series Honeywell All rights reserved 7 EN0H-0458GE25 R1014