CLIMACIAT AIR COMPACT

Similar documents
FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

Centrifugal air heaters hot water or electrical supply

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

Compact and silent Scroll compressors All-season operation

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

NA B AIR COMPACT. Instruction manual

Precision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C

V3000 KNX. KNX PID control system on water GENERAL DESCRIPTION

Vertical self-contained air conditioner

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

Precision air handling cabinets Ciatronic MICRO/EXPAIR

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

USE sizes Horizontal and vertical versions Single or double flow arrangement (side by side or superimposed)

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

42AM. Air heaters PRODUCT SELECTION DATA

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

The ultimate in air handling units: directly and indirectly fired

High temperature air-to-water heat pumps

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

New HEE control. n Room thermostat for THREE-PHASE or SINGLE-PHASE installation

Aquaciat Free cooling

DYNACIAT ILG. Use. Description. Heat pumps

KPSW CONSOLE TERMINAL UNIT

The ultimate in air handling units: directly and indirectly fired

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

UNITES TERMINALES ET MINI CTA FIDJI

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER

The ultimate in air handling units: directly and indirectly fired

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

NEW COMFORT UNITS Major Line. Sheer design sustainable innovation NA 09.73A

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

THE CARRIER COMFORT LINE

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Roof top SPACE RPC 450Z R407C M011

Energy. The Energy ducted units have been designed. Heat Recovery Unit

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

Centeral Station Air Handling Unit

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

The ultimate in air handling units: directly and indirectly fired

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

EDPAC International Close Control Air Conditioning Products E

TopVent Design Handbook

High temperature air-to-water heat pumps

air handling units AT THE LEADING EDGE OF AIR FLOW


Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

the new generation of cassette comfort units Innovative casing (Flexiway concept) integrates perfectly into suspended ceilings Air purification system

Heating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT

NA B MAGISTER. Instruction manual

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Process glycol chillers

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Working in partnership with To create the perfect environment

Caice Attenuator Selector - Specifier Edition

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Fresh Air Ventilation

Fresh Air Ventilation

GHE Dehumidifiers for radiant cooling systems with heat recovery

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Aquaflair TRAC-TRAF-TRAH

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

DYNACIAT POWER. High energy efficiency Compact and quiet

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Roof top SPACE RPC 315Z R407C MA00

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

Modula Standard Performance

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Transcription:

Air handling units The modular and ultra-slim AHU to guarantee perfect solution Ideal for a compact installation Available in single-flow or aligned or adjacent dual-flow versions Air flow: up to 6 000 m 3 /h Available pressure: up to 1 000 Pa Use The AIR COMPACT air handling unit is a modular ventilation unit, which can be configured to meet all your requirements whilst complying with current standards. It is available in several versions: single-flow, aligned dualflow, adjacent dual-flow. The AIR COMPACT AHU is used for fresh air change, air recirculation, air extraction and air handling using its filtration, heating, cooling, recovery and ventilation functions. There are three different installation possibilities to meet your needs: - Horizontal ceiling-mounted version, accessed from underneath, - Horizontal floor-mounted version, accessed from the top, - Vertical wall-mounted version, accessed via the front. It is available in three sizes to meet all your needs and able to handle air flows from 1 000 to 6 000 m 3 /h. Reduced thickness (400 mm) and great compactness to be fitted into the tightest spaces. This range is particularly well-suited to tertiary buildings: - Administration, offices, - Education facilities, libraries, community centres, - Bars, hotels, restaurants, - Shopping centres, - Nursing homes, healthcare facilities, - Collective housing. All installations require ventilation. Range The range comprises 3 sizes from 1 000 to 6 000 m 3 /h. There are four standardised lengths of casing, adapted to the configuration and options selected. The AHU will therefore comprise one or several casings, depending on your selection; 610, 830, 1 100 and 1 400 mm modules. HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.637 A 1

AIR COMPACT 25 40 60 Assembly Ceiling- / Floor-mounted / Vertical Width/Height 750*400 1 310*400 1 880*400 Nominal air flow (m 3 /h) (Speed: 3.1 m/s across finned row) 2 000 4 000 6 000 "Asynchronous motor NPL technology" "EC motor EBM technology" Pleated filters Opacimetric filters (short flexible pockets) Opacimetric filters (rigid pockets) Electric motor 1 1 2 2 0.55 kw - 4-pole/1.1 kw - 2-pole/1.4 kw - 2-pole Number of inverters 1 1 1 1 EC motor 1 1 2 2 1 kw G4 / M5 / F7 HEE / F9 HEE M6 / F7 M6 / F7 / F8 / F9 Hydraulic heating coil 1/2/3 rows 1/2/4 rows 1/2/4 rows Hydraulic cooling coil Direct expansion cooling oil 3/4/6 rows 3/6 rows Electric heating coil 15 kw 24 kw 33 kw Adjacent plate heat exchanger Yes Yes No Description Casing Double-skin panels made from steel sheets, galvanised on both sides, thickness 8/10 mm RAL 9006 lacquer coated finish on external panels. M0/A1 fire rating Mineral wool, thickness 25 mm Connection and utilities Hydraulic connection possible on the right or left (to be specified when ordering) The access doors are positioned according to the choice of model: - Horizontal ceiling-mounted model: access doors located underneath the unit - Horizontal floor-mounted model: access doors located on top of the unit - Vertical model with wall-mounting plate: access doors located on the front of the unit Damper Uncased external damper Damper in choice of sealing class 1 or 3, as per EN 1751 Damper thickness 110 mm and height 310 mm Optional servomotor Filtration Filter cell with universal dimensions Three filtration stages possible per air flow rate Pleated filters in efficiency class G4, M5, F7 and F9 HPE Short bag filters in efficiency classes M6 to F7 Rigid bag filters in efficiency classes M6 to F9 Pressure tapping as standard on each filtration stage Option, pressure switch, pressure gauge, Heat exchange coil n Hydraulic coil Copper tube, aluminium blade Choice of 3 coil sizes for each AHU size Antifreeze thermostat with optional automatic reset Stainless condensate drain pan n Evaporator coil Copper tube, aluminium blade Choice of 3 coil sizes for each AHU size Stainless condensate drain pan n Electric heater Shielded resistors in scrolled finned pipes 2 upper limit safety thermostats: one with automatic reset and one manual Anti-radiation screen, depending on the upstream and downstream elements Output power supplied by the electric heaters AHU size Main casing Additional box 2 stages 2 stages 4 stages 25 2 * 7.5 = 15kW 2 * 7.5 = 15kW 4 * 7.5 = 30kW 40 2 * 12 = 24kW 2 * 12 = 24kW 4 * 12 = 48kW 60 2 * 16.5 = 33kW 2 * 16.5 = 33kW 4 * 16.5 = 66kW 2 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.637 A

Ventilation "Plug Fan" type direct drive FMA 1 or 2 FMA for each air flow rate, depending on the size and conditions Plug fan combined with a motor at the end of the shaft AC motor with optional frequency inverter EC motor (electronically commutated motor with built-in variable speed control) AIR COMPACT 25 40 60 Assembly Ceiling- / Floor-mounted / Vertical Nominal air flow (m 3 /h) (speed: 3.1 m/s across finned row) 2 000 4 000 6 000 "Asynchronous motor Electric motor 1 1 2 2 NPL technology" 0.55 kw - 4-pole/1.1 kw - 2-pole/1.4 kw - 2-pole Number of inverters 1 1 1 1 "EC motor EBM technology" EC motor 1 1 2 2 1 kw Total pressure Pression totale (Pa) Pa 1600 800 EBM NPL 400 200 AIR COMPACT 25 100 1000 1500 2000 2500 Flow Débit rate en min 3 m/h 3 /h Total Pression pressure totale Pa (Pa) 1600 2*NPL 800 400 EBM NPL 2*EBM 200 AIR COMPACT 40 100 2000 2500 3000 3500 4000 4500 5000 Flow Débit rate en min 3 m/h 3 /h Total Pression pressure totale (Pa) Pa 1600 2*NPL 800 2*EBM 400 200 AIR COMPACT 60 100 4000 4500 5000 5500 6000 6500 7000 Flow Débit rate en in mm 3 /h /h HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.637 A 3

Accessories and options 2-way mixing box: 3 air flow positions available 3-way mixing box Angled or straight plenum Sound attenuator Adjacent plate heat recovery unit (sizes 25 and 40 only) Control Control - Peripheral options and power terminal block - Surface-mounted electric heater unit, or delivered unassembled - Control by factory preprogrammed controller, algorithm created in-house - Hand-held cabled micro-terminal - Fault summary contact - Control by constant flow/constant pressure/co 2 - Pressure and temperature sensors, depending on the selection - Numerous options and functions available n Electrics box for power, control and internal regulation of the unit, comprising as standard: - 3-Ph / 400V power supply + Earth - Main disconnect switch - Protected transformer - Protection and control of all electrical components by a circuitbreaker and contact switch Space requirements and dimensions DIMENSIONAL SPECIFICATIONS AHU size 25 40 60 External dimensions (in mm) 750 * 400 1 310 * 400 1 880 * 400 Casing length (in mm) 610 830 1 100 1 400: Four standardised lengths of casing, automatically adapted to the components and options selected 610 mm module 1 x 540 mm door 830 mm module 1 x 595 mm door 1 100 mm module 1 x 595 mm door + 1 x 435 mm door 1 400 mm module 1 x 595 mm door + 1 x 735 mm door 28 WIDTH WIDTH 28 35 595 165 35 35 595 735 35 830 1 400 4 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.637 A

Air connection n Air connection Air handling units Air connection AHU intake - AHU discharge - Mixing and plate heat exchanger A B C D AIR COMPACT 25 750 690 3 238 AIR COMPACT 40 1 310 1 250 6 212.3 AIR COMPACT 60 1 880 1 820 8 230.5 n Examples of compositions HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.637 A 5

This document is non-contractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification. Head office Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tel.: +33 (0)4 79 42 42 42 Fax: +33 (0)4 79 42 42 10 info@ciat.fr - www.ciat.com CIAT Service Tel. : 08 11 65 98 98 (0,15 / mn) Fax : 08 26 10 13 63 (0,15 / mn) Compagnie Industrielle d Applications Thermiques - S.A. with a registered capital of 26 728 480 - R.C.S. Bourg-en-Bresse B 545 620 114 Système de Management certifié 6 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.637 A