Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Similar documents
Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

FIGARO. 08/52543/0 (UK) Issue 1

SP16. 08/50740/1 (UK) - Issue 1

CORELLI Micro Fireplace Assembly Instructions Model: MCFP15CRO

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

SP420 & SP14 SP520 & SP15 SP920 & SP19. 08/19222/9 (UK) - Issue 9

Oil filled Radiators - Models : OFX750/1000/1500 & OFX750TI/1000TI/1500TI

Opti-V Fire. Model: PGF20 Instructions

26 FIREBOX EN RU UA FR

INSTRUCTION MANUAL. Dimplex Saletto (LPPE) Installation and Operating. Models: LPP050E / LPP075E / LPP100E / LPP150E

INSTRUCTION MANUAL. Creda CEPE Contour Panel Heater. Installation and Operating. Models: CEP050E / CEP075E / CEP100E / CEP150E / CEP200E

OPTIMYST WALL ENGINE OMWFC20 RTOPW20 PEM20

OFC1000, OFC1500, OFC2000, OFC2500 OFC1000TI, OFC1500TI, OFC2000TI & OFC2500TI

JUNEAU JUN. 08/51193/0 Issue 0

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

155mm. 820mm. 540mm E D. 940mm. 600mm

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Charlotte CRT20AB, Charlotte CRT20BR & Brookline BKL20

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

INSTALLATION & USER INSTRUCTIONS

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Installation Instructions & Operating Manual IMPORTANT

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS

OPERATING INSTRUCTION MANUAL

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS

DANVILLE DNV20AB, DNV20BR, DNV20BL & DNV20CH

2kW Wall Mounted Electric Fire Complete with flat glass front panel. Installation Instructions & Operating Manual

Dimplex ebrochure PDF

(SP4) SP420 (SP5) SP520 (SP9) SP920 AUS/NZ. 08/50019/5 Issue 5

MOCCA CUBIC AUS/NZ. 08/53066/0 Issue 2

QUALITY SPACE HEATERS

INSTALLATION & USER INSTRUCTIONS

SP1 Wallfire. SP2 Wallfire. SP3 Wallfire. SP8 Wallfire AUS/NZ. 08/19282/2 (AUS & NZ) Issue 2

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

instructions OIL FILLED RADIATOR V V and V551225

Imperial Electric Fires

INSTALLATION & USER INSTRUCTIONS

IMPORTANT SAFETY INFORMATION:

OAKHURST, AUBERRY OKT20, AUB20

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

IMPORTANT SAFETY INFORMATION:

BFH range. Features. Base Unit Heater - BFH range

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

2kW ELECTRIC HEATER WITH REMOTE CONTROL NEBRASKA NEBRASKA

HINTS AND TIPS Cleaning and maintenance HELPLINE

INSTALLATION & USER INSTRUCTIONS

ECOLEC PANEL HEATERS GENERAL NOTES.

2.8KW ELECTRIC FAN HEATER

PTC Tower Heater. Instruction Manual THE SCIENCE BEHIND HEAT.

HCC663 Ceramic Hob. Manual for Installation, Use and Maintenance

INSTRUCTION MANUAL. Dimplex XLE Series Heater. Installation and Operating. Models: XLE050 / XLE070 / XLE100 XLE125 / XLE150

instructions FAN HEATER HVF3533 Please retain these instructions for future reference

MHC002 Ceramic Hob Manual for Installation, Use and Maintenance

2kw Remote Control Electric Fire. User and Installation Instructions

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

CFH60, CFH90 & CFH120 Electronic Wall Mounted Fan Heater

Instruction Manual. Oil Heaters. Model: OIL5, OIL7, OIL9 & OIL11T READ AND SAVE THESE INSTRUCTIONS

OIL FILLED RADIATOR Instruction manual

PTC Ceramic Heater. Instruction Manual THE SCIENCE BEHIND HEAT

GLASS HEATER OWNER S MANUAL. Model No. GH-15A

200W Frostwatch Radiant Heater Operation Manual

INSTALLATION & USER INSTRUCTIONS

HINTS AND TIPS Cleaning and maintenance HELPLINE

Manual for Ceiling Patio Heater

User Guide PLEASE READ BEFORE USE AND KEEP FOR FUTURE REFERENCE.

AC500T, AC1000T, AC1500T, AC2000T

5KW ELECTRIC FAN HEATER

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

HELPLINE If you have any difficulty with your appliance, do not hesitate to call us. Website

De Longhi Appliances via Seitz, Treviso Italia /11.13

Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

WALL MOUNTED ELECTRIC FIREPLACE (heat blowing from the front series)

Installation and Maintenance Instructions XPG144/145/146 Electric Fires

ELECTRIC FIREPLACE with Remote Control

The Visage & Elegance Range of Electric Radiators INSTALLATION & OPERATING INSTRUCTIONS

Health and Safety (cont)

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

ST E /ST E / ST E / ST E ST E / ST E / ST E

AMBION FLAME. INSTALLATION AND USER INSTRUCTIONS

Models: RP-10, RP-15, RP-20. User Manual

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

15KW ELECTRIC FAN HEATER

6.6L Stainless Steel Urn. User Manual

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

NEXIUN ANALOGUE INERTIA RADIATOR, PROGRAMMABLE WITH PILOT WIRE INSTALLATION INSTRUCTIONS AND USER GUIDE NEX4PW NEX8PW NEX12PW NEX14PW

Built in Electric Ceramic Hob. Instruction Manual

/09.15_00. De Longhi Appliances via Seitz, Treviso Italia

INSTRUCTIONS FOR CARBON INFRARED HEATER

HINTS AND TIPS Cleaning and maintenance HELPLINE

DXAPV3N. Air Purifier. With. Enviro-neutralising Technology DXAPV3N

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Transcription:

A world of expertise Operating Instructions These instructions should be read carefully and retained for future use. Note also the information presented on the appliance. Girona Glass Panel Heaters Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B INDGUKP7RG ISSUE 4

IMPORTANT These instructions should be read carefully and retained for future use. Note also the information presented on the appliance. IMPORTANT SAFETY ADVICE When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following: IMPORTANT The wall bracket supplied with the appliance must be used. WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL. IMPORTANT If the heater is installed in a room containing a bath or shower, it must be so installed that switches and other controls cannot be touched by a person using a bath or shower. Do not use outdoors. Do not locate the heater immediately below a fixed socket outlet or connection box. Do not cover the heater. Do not place material or garments on the heater, or obstruct the air circulation around the heater, for instance by curtains or furniture, as this could cause overheating and a fire risk. NEVER cover or obstruct in any way the heat outlet slots at the top of the heater or the air inlet slots in the base of the heater. The heater carries the Warning symbol indicating that it must not be covered. CAUTION - Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present. This appliance can be used by children aged from 8 years and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintainance shall not be made by children without supervision. Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintainance. Note that due care and consideration must be taken when using this heater in series with a thermal control, a program controller, a timer or any other device that switches on the heat automatically, since a fire risk exists when the heater is accidentally covered or displaced. If the supply cord is damaged it must be replaced by the manufacturer or service agent or a similarly qualified person in order to avoid a hazard. WARNING: Servicing and product repairs should only be undertaken by the manufacturers approved service agent or a similarly qualified person, using only exact manufacturer approved spare parts.

Electrical WARNING THIS APPLIANCE MUST BE EARTHED The electrical installation must be carried out by a competent electrician, and be in strict accordance with the current I.E.E. regulations for Electrical Equipment in Buildings. The wires in this mains lead are coloured in accordance with the following code : GREEN AND YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE BLACK : PILOT WIRE - see also Pilot Wire Connection. The heater is fitted with a length of flexible cable type H05VV-F size 4 x 1.0mm 2 for connection to the fixed wiring of the premises through a suitable connection box positioned adjacent to the heater. A means for disconnection must be incorporated in the fixed wiring of the premises in accordance with the wiring rules. The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3mm. Pilot Wire Connection The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex programmers. If, however a programmer is not being used, the pilot wire should be isolated in accordance with the current IEE Wiring Regulations. IMPORTANT - DO NOT connect the BLACK pilot wire to earth. Care should be taken with the installation of the pilot wire(s) as when switching to background (setback) they become energised at 240V although only at a current of less than 100mA. In every case a suitable means of isolation must be provided for the pilot wire and marked to indicate that two sources of supply may be present at the heater. Where pilot wires are installed separately from the heater final sub-circuit they should be protected, double insulated and carry their own integral earth continuity conductor. Supplementary Earth Bonding Should Equipotential Earth Bonding be required the earthing conductor in the supply cord is deemed to provide the supplementary bonding connection (see Regulation 544.2.5, 17th Edition I.E.E. Wiring Regulations). Please note that lit cigarettes, candles and oil burners, combined with the convection effect of electric heaters can cause soot deposits to build up on the surface directly above and to the sides of the heater. This is not a fault of the heater. Extensive burning of candles or smoking in the operating environment of this product can produce heavy discoloration within a few months of use.

General The heater is designed for wall mounting on the wall bracket supplied. It should only be operated when in the upright position as shown - see Fig.1 and Fig.2. 150 Min. A 565 All models are splashproof to IPX4 standard and may be used in bathrooms, however not in the immediate vicinity of baths, showers, water connections, wash basins or swimming pools. 150 Min. Before connecting the heater check that the supply voltage is the same as that stated on the heater. Fig. 1 Dimensions (millimetres) 300 Min. shelf B Model(s) Watt A (mm) B (mm) GFP050 W/B 0.5 kw 530 107 GFP075 W/B 0.75 kw 530 107 GFP100 W/B 1.0 kw 700 107 GFP150 W/B 1.5 kw 770 107 GFP200 W/B 2.0 kw 940 107 Wall Mounting IMPORTANT The wall bracket supplied with the appliance must be used. The heater should be positioned observing the minimum clearances stated around the heater - see Fig. 1 and Fig. 2. DO NOT locate the heater immediately below a fixed socket outlet or connection box. 1. Remove the wall mounting bracket from the back of the heater by depressing the spring latch at the top of each bracket - see Fig. 3. 2. Fix the wall bracket securely to the wall through the four screw holes provided. 3. Present the heater to the wall bracket, and engage lower slots in the back with bracket. 4. Raise the heater to upright position and push the heater onto the bracket to engage the top latches. D 255 Min. C Fig. 2 C D GFP050 390 300 GFP075 390 300 GFP100 560 300 GFP150 630 300 GFP200 800 300 Fig. 3

Operation Switching On the Heater (see Fig. 4) The controls are located on the right hand side on top of the appliance, lift flap to access the controls - see Fig. 4. The button marked controls the electricity supply to the product. An indicator beside the button shows when the unit is powered ON. Setting Desired Temperature (see Fig. 5) The heater is fitted with an adjustable thermostat enabling the room temperature to be controlled by adjusting the slider accordingly. The min setting represents a room temperature of approximately 5 o C and may be used for protection against frost. The MAX setting represents a room temperature of approximately 30 o C. The symbol glows when the product is providing heat. Turn on the heater using the button and move the thermostat slider to the desired position. When the room temperature has reached the desired level, the power to the elements will be reduced, the heater will then maintain the room temperature at the chosen level. NOTE - Your heater may not come on when the thermostat slider is at a low setting. This is due to the room temperature already being higher than the thermostat setting. Fig. 4 Fig. 5 Background Temperature When used in conjunction with a remote programming device supporting a background/ setback setting, the heater will automatically operate at a room temperature setting of 5 o C less than the thermostat setting when the programme is in background/setback mode. Limiting the Thermostat Setting Before wall mounting the product the installer may wish to limit the heat selection slider movement for the operator. This is achieved by removing the two plastic pins (see x in Fig. 6) from the rear of the thermostat moulding using pliers and inserting them in the preferred holes to limit the slider movement. x Fig. 6

Notes to the Installer Test Mode When the heater is connected via a pilot wire system, the test mode allows the installer to check whether the heater is responding correctly to the incoming pilot wire signal. Before switching the heater on at the mains, place the thermostat slider in the MAX position, then press and hold the button whilst switching on the mains. The unit will now enter a test state for four minutes. During this test state the neon will indicate the pilot wire status: NEON PILOT WIRE CONTROLLER MODE Neon on - ON Neon off - OFF Neon flashing fast every 0.1sec - FROST Neon flashing slow every 0.5 sec - SETBACK Accessory Modules Optional accessory modules are available for use with this range of heaters - see separate User Instructions for details on the operation of each accessory module. Before fitting a control module switch the heater off at the mains supply. To insert a module, the plug-in protective cover on the right hand side of the thermostat unit at the top of the heater must first be removed. Insert a flat-head screwdriver into the side of the cover and prise away from the heater - see Fig. 7. Lift the cover away from the heater to reveal the slide in compartment. Insert the accessory module into the slot ensuring it is positively located in position - see Fig. 7. Secure the module in place with the screw provided. Switch the heater on at the mains supply. Fig. 6 Fig. 7 Safety - Overheat Protection For your safety this appliance is fitted with a thermal cut-out. In the event that the product overheats for some reason, the cut-out prevents excessive temperatures on the product by cutting the power to the heater. Once the heater has cooled down, it will reset automatically, it will continue to cycle on and off automatically until the reason for overheating is removed.

Energy Saving Tips The energy we use to heat, light and power our homes contributes over a quarter of the UK s carbon emissions, the principle contributor to climate change. Around half the energy used in the home is for heating and hot water, so using your heating system efficiently will not only help the environment, but also save you money. Energy efficiency tips for heating and hot water 1. Don t set the temperature to high... By reducing the thermostat setting by just 1 o C can reduce your energy use by as much as 10%. And if you re going away during the winter, leave the thermostat on the frost protection setting to provide protection from freezing at a minimum cost. 2. Use it where you need it... Set the appropriate temperature on your heaters for the room they are in; for example, leave the thermostat on a heater in a spare bedroom on a lower setting. 3. Use it when you need it... Use heaters fitted with timers or linked to central controllers to turn the heating on only when you need it and automatically switch it off when you don t. 4. Curtains Close your curtains at dusk to stop heat escaping through the windows. 5. Windows Nearly 25% of heat loss can occur through poorly insulated frames and single glazing. If you can t afford to double glaze all your windows, go for the rooms you heat most. 6. Treat your hot water tank...give it a jacket An insulating jacket for hot water tanks costs only a few pounds and pays for itself within months. Fit one that s at least 75mm (3 ) thick and you could save 10-15 a year. 7. Water Use a shower if you have one to save time, money and water. Don t set the thermostat too high on your water heater- 60 o C/ 140 o F is usually adequate for bathing and washing. Put the plug in when running hot water in your sink - leaving hot taps running is both wasteful and expensive. Ensuring dripping taps are repaired quickly. In just one day, you could waste enough water to fill a bath. Other Energy Saving Tips for Around the Home 1. Lights Turn off lights whenever you leave a room for more than ten minutes. Use low-energy bulbs wherever you can as they use less than a quarter of the electricity used by ordinary light bulbs and last ten times longer! 2. Cooking Use the right size pan for food and cooker hob. Keep saucepan lids on - this enables you turn down the heat. Boil water for cooking in a kettle first.

Cleaning WARNING - ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER. Before commencing cleaning, unplug the heater and allow it to cool. Disconnect the electricity supply to the appliance. The outside can be cleaned by wiping it over with a soft damp cloth and then dried. Do not use abrasive cleaning powders or furniture polish, as this can damage the surface finish. To release the heater from the wall bracket for cleaning or redecoration, depress the latch on each bracket (See Fig.3) and hinge forward. Recycling For electrical products sold within the European Community. At the end of the electrical products useful life it should not be disposed of with household waste. Please recycle where facilities exist. Check with a Local Authority or retailer for recycling advice in your country. After Sales Service If this product appears damaged when first received or does not function correctly contact us by e-mail at aftersales@dimplex.co.uk or call 0844 879 3588. For ROI please call 01 842 8222. Do not return the product in the first instance as this may delay us providing you with a satisfactory service. ACCIDENTAL DAMAGE IS NOT COVERED UNDER THE WARRANTY Your product is guaranteed for two years from the date of purchase. Within this period we undertake to repair or exchange this product free of charge provided it has been installed and operated in accordance with these instructions. Should you require assistance with this product please go to www.dimplex.co.uk and click on Customer Support or e-mail us at aftersales@dimplex.co.uk. Alternatively call our contact center on 0844 879 3588 (UK only). This is a Lo-call number from a BT Landline - other providers including mobile phones may charge you more. For ROI please call 01 842 8222. To assist you, we need the following information: model number and serial number (these are found on the back of the appliance), nature of the fault and date of purchase. Please retain your receipt as proof of purchase. Your rights under this guarantee are additional to your statutory rights, which in turn are not affected by this guarantee. This product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC A world of expertise GDC Group LTD. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing. A division of the GDC Group LTD, Millbrook house, Grange Drive, Hedge End, Southampton SO30 2DF.