5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

Similar documents
5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

5CO52XX Series Fan UL Model No. : 5CO52. Owner s Guide and Installation Manual. Attach sales receipt to this card and retain as your proof of purchase

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

5WF42XX Series Fan UL Model No. : AC-542OD. Owner s Guide and Installation Manual

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

8TNR56XXXD-V1 Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 8TNR56XXXD-V1

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

5GFR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5GFR52XXD

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

Ceiling Fan Installation Instructions

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

5SLR52XXD-B Series Fan UL Model No. : 5SLR52. Owner s Guide and Installation Manual

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

3SKYR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3SKYR56(XXXXX)

Owner s Guide and Installation Manual

14PRR62XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 14PRR62(X)

3AVOR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3AVOR56XXXXX

Ceiling Fan Installation Instructions

Ceiling Fan Installation Instructions

Ceiling Fan Installation Instructions

Ceiling Fan Installation Instructions

CELEBRITY DELUXE 52" indoor fans

Ceiling Fan Installation Instructions

Owner s Manual Ceiling Fan Installation Instructions

Ceiling Fan Installation Instructions

LONG BEACH 52" outdoor fans

To register your fixture, please visit our website: MonteCarloFans.com NEED HELP? NECESITA AYUDA? AVEZ-VOUS BESOIN D AIDE?

To register your fixture, please visit our website: MonteCarloFans.com NEED HELP? NECESITA AYUDA? AVEZ-VOUS BESOIN D AIDE?

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

CEILING FAN OWNER'S MANUAL

52 SAN LUCAS CEILING FAN

Torrena 42 Ceiling Fan

Camarillo 52 Ceiling Fan

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

READ AND SAVE THESE INSTRUCTIONS

CEILING FAN OWNER'S MANUAL

Hanson LED C e i l i n g F a n

52 BARSTOW CEILING FAN

FOR AMD SAVE THESE INSTRUCTIONS OWNER'S INSTRUCTION MANUAL CAUTION. Intertek. Note: Approximate time of assembly is 30 min to 1 hour.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

52 BAYTOWNE CEILING FAN

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

52 STRATHMERE CEILING FAN

Gunnar Ceiling Fan. model no OWNER S MANUAL

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

LIMITED LIFETIME WARRANTY

LIMITED LIFETIME WARRANTY

48 TAYLOR CEILING FAN

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

LIMITED LIFETIME WARRANTY

Lifetime Limited Warranty

CEILING FAN OWNER'S MANUAL

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

LIMITED LIFETIME WARRANTY

MACBAY CEILING FAN. welcoming sophisticated inspiring ITEM # MODEL #L1405 Español p. 19 ATTACH YOUR RECEIPT HERE

CEILING FAN OWNER'S MANUAL

LIMITED LIFETIME WARRANTY

CEILING FAN OWNER'S MANUAL

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

BAY BRIDGE CEILING FAN

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

ST. KITTS CEILING FAN

#ADENCE4- $ESIGNED )NCLUDES #OOL4OUCH4- +ICHLER )NSTRUCTION #USTOMER KHA

Lifetime Limited Warranty

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Owner s Guide and Installation Manual

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Downrod. Blades. Maintenance & Cleaning.

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

52 CEILING FAN. Owner s Manual Models #50336, 50337

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

Table of Contents. Ceiling Bracket Installation

Transcription:

Owner s Guide and Installation Manual 5YK60XXX Series Fan CUL Model NO. : 5YK60XXX Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER NAME: RETAILER ADDRESS: To register your fixture, please visit our website www.montecarlofans.com 10.5 kgs 23.1 lbs Total fan weight

Cautions and Warnings WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70) including fire-rated construction. Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed carefully up into the outlet box. WARNING: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade. WARNING: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked Acceptable for Fan Support of 15.9 kg (35 lbs) or less And Use Mounting Screws Provided With The Outlet Box. CAUTION: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the building structure (or the ceiling joist). WARNING: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades. Attach the mounting bracket using only the hardware supplied with the outlet box. WARNING: To reduce the risk of fire or electric shock, do not use this fan with any unverified solid state fan speed control device, or variable speed control. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application. Never place a switch where it can be reached from a tub or shower. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit s operation. Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. All set screws must be checked and tightened where necessary before installation. Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers Customer Service 800-969-3347 Customer Service Center 7400 Linder Ave. Skokie, IL 60077 www.montecarlofans.com 2

1 2 3 ON ON Mounting bracket OFF OFF Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. Use AC 120V/60HZ power supply only. Before installing this fan make sure the outlet box is properly installed to the house structure. To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. (Mounting must support at least 35 lbs.) Use metal outlet box suitable for fan support and use only the screws provided with the outlet box (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member ( a loose box will cause the fan to wobble). Remove the two outlet box screws provided with the box, aligning the holes of the mounting bracket with the holes of the outlet box. Reinstall the 2 outlet box screws securely. Downrod Mount Installation 4 5 6 Downrod Canopy Cross pin Keeper pin Canopy bottom disc Downrod Cross pin Keeper pin Yoke cover Partially loosen downrod set screws from yoke at top of motor assembly. Remove preassembled cross pin and keeper pin from downrod. Place downrod over canopy, canopy bottom disc and yoke cover. Thread lead wires and safety cable from motor assembly through downrod. Slip downrod into motor housing yoke, aligning holes and install cross pin and keeper pin. Insert cross pin through yoke and downrod until point appears on the other side, and insert keeper pin on cross pin. Pull the downrod up tight against the cross pin, and then evenly tighten the downrod set screws on motor housing yoke. Place yoke cover on top housing of fan. Warning: Cross pin and keeper pin must be installed securely, failure to install them will result in serious injury. 3

7 8 SAFETY CABLE INSTALLATION 9 Tab Slot Lag screw Safety cable Wall switch White (Neutral) Power source Black (Live) Ground/Green Black Blue White Washer Lock washer Install ball end of downrod into mounting bracket opening. Align (engage) slot on ball with tab on mounting bracket. Warning: Failure to align slot on ball with tab may result in serious injury. Important: If using the angle mount, make sure open end of mounting bracket is installed facing the higher point of the ceiling and make sure the ceiling angle is not steeper than 30º. For Canadian installation and for USA fan and light kit combinations over 35 lbs, in both flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag screws, washers and lock washers provided. Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires. Note: If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts In The Outlet Box. Make wiring connections using wire connectors provided as indicated above. White from fan to White (Neutral) from house. Black and Blue from fan to Black (Live) from house. Connect all green grounded wires to Grounded wire from House. Make sure that no filaments are outside of the wire connectors. 10 11 Grounded wires Ungrounded wires Stud Go to step 19 to finish installation After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices after being made should be turned upward and pushed carefully up into the outlet box. Lift Canopy allowing the 2 studs to protrude through the canopy. Next lift the cover ring and install knurled nuts as shown. Tighten the knurled nuts securely. The canopy should adjust for any irregularity in the ceiling or Outlet box. Make sure the studs protruding from the bottom of the Mounting bracket are installed with threads all the way through the bracket. 4

Flush Mount Installation 12 13 14 Side cover Rubber pad Remove every other screws from yoke located on top of fan assembly. Keep screws. Note: Flush mount is not available with vaulted ceiling. Remove side covers from canopy exposing 4 holes. 2 closed holes and 2 open L shape holes. Place rubber pad and canopy over lead wire and safety cable and align the larger holes in canopy and holes on rubber pad with the set screws on yoke. Reinstall the 3 set screws remove in step 12. Tighten screws securely. 15 16 SAFETY CABLE INSTALLATION 17 White (Natural) Wall switch Power source Hook Lag screw Black (Live) Grounded/ Green Black Blue White Safety cable Washer Lock washer To prepare the fan for wiring, hang fan onto mounting bracket by sliding the canopy over the mounting bracket hook (Use one of non-slotted holes on the rim of the canopy). For Canadian installation and for USA fan and light kit combinations over 35 lbs, in both flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag screws, washers and lock washers provided. Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires. Note: If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts In The Outlet Box. Make wiring connections using wire connectors provided as indicated above. White from fan to White (Neutral) from house. Black and Blue from fan to Black (Live) from house. Connect all green grounded wires to Grounded wire from House. Make sure that no filaments are outside of the wire connectors. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices after being made should be turned upward and pushed carefully up into the outlet box. 5

18 19 20 Blade Blade bracket Shipping stabilizers Install 2 of the screws to the side panel of mounting bracket corresponding to the open slotted holes on the canopy upper rim, screws provided. Remove the thread studs from the lower part of the mounting bracket. Install blade bracket with blade by 3 blade screws and washers provided. Tighten screws securely. Repeat this process for remaining blades. Lift fan to mounting bracket, aligning the L shape holes on canopy with the screws on the mounting bracket. Turn the fan clockwise to lock in position. Install the other 2 canopy mounting set screws from the hardware pack and tighten all screws securely. 21 Remove shipping stabilizers from motor assembly. Install the blade assembly to motor using the preinstalled screws. Tighten screws securely. Repeat this process for remaining blade assemblies. 22 Reverse switch Loosen 2 and remove 1 preassembled screw from top plate of switch housing. Connect the quick connectors from fan and switch housing. Make sure quick connectors are clasped firmly. Install the switch housing onto the top plate, aligning the keyhole slots on the switch housing with the preassembled screws on top plate and twist it clockwise till lock. Reinstall the set screw removed in step 21 and tighten all screws securely. Setting the reverse switch in the left hand side will result in downward airflow and setting the switch in the right hand side will result in upward airflow. Note: Reverse switch must be set either way completely. If the reverse switch is set in the middle position, fan will not operate. Install fan pull chain to preassembled pull chain on fan. Pull chain provided. 2018 Monte Carlo Fan Company 6 10/2018

Trouble Shooting or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, installation, please call our Customer Service Center at the number printed on your parts list insert sheet. Warning means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Trouble Suggested Remedy 1. If fan does not start: 1.Check main and branch circuit fuses or circuit breakers. 2.Check line wire connections to fan and switch wire connections in switch housing. CAUTION either way. Fan will not operate when switch is in the middle. 4.If this fan uses remote controller, make sure dip switches are setting properly and make 2. If fan sounds noisy: 3. If fan wobbles: 1.Check to make sure all screws in motor housing are snug (not over tightened). 2.Check to make sure the screws which attach the fan blade holder to the motor are tight. 3.Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing. CAUTION 4.Check to be sure light bulb is tight in socket and not touching the glass shade. 5.Some fan motors are sensitive to signals from Solid State variable speed controls. 6.Allow "break-in" period of 24 hours. Most noises associated with a new fan will disappear after this period. 1.If this is a downrod mount fan, make sure the ridge on mounting bracket engages the notch in the downrod ball. 2.Make sure that canopy, mounting bracket or mounting plate are tightened securely to 4. If light does not work: 4.Check that all blade holders are tightened securely to motor. 5.Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the blades. Measure this distance from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is positioned for measurement. Repeat for each blade. If all blade levels are not equal, you can adjust blade levels by the following procedure. To adjust a blade tip down, insert a washer (not supplied) between the blade and blade holder at the screw closest to the motor. To adjust a blade tip up, insert washer (not supplied) between the blade and blade holder at the two screws farthest from the motor. Reverse the position of the washer if blades mount from top of blade. 6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation. If the above steps do not eliminate the wobble problem, you will need to dynamic balance your fan with balancing kit provided. 1.Check blue wire from fan to make sure it is connected to hot wire from house. 2.Check for loose or disconnected wires in fan switch housing. 3.Check for loose or disconnected wires in light kit. 4.Check for faulty light bulb and make sure bulb is tight in socket. 5.Remove light kit and check the plug connections if they are present. 6.If this fan uses remote controller, make sure dip switches are setting properly and make CAUTION: Make sure main power is turned off before entering switch housing and/or canopy. 7

Nov.2018