Test Report Reg.no 12.

Similar documents
Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

Test Report: ICL/H18/9039 Rev 1

Additional Reaction to Fire Classification Report

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

IMO Resolution MSC 61(67): Annex 1: Part 2

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

BS EN ISO : 2010

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

IMO COMPREHENSIVE REVIEW OF THE FIRE TEST PROCEDURES CODE

BS EN ISO : 2010

BS EN ISO : 2010

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES

BCTC CARPET TECHNICAL CENTRE

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

C-01 FIRE DECKS AND BULKHEADS

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN : 2001 & IEC :2000

Test Report: ICL/CR15/11/087

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

Review Fire Test Report

TFI Report Reaction to fire test

Contact person Date Reference Page Richard Johansson P (2) Fire Research

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

Global Requirements for the Fire Protection of Ships. Dr Janet Murrell Warrington Certification Ltd

4, DG UV Test. EC-Type Examination (Module B) Certificate. A.1/3.11 a - "A" Class divisions, fire integrity

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

NF X : Parts 1, 2, 3, 4 & 5

Analysis Report

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

RESOLUTION MSC.101(73) (adopted on 5 December 2000) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR APPLICATION OF FIRE TEST PROCEDURES

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Guideline No.: C-02(201510) C-02 FIRE DOORS. Issued date: October 20,2015. China Classification Society

BS 476: Part 6: 1989+A1:2009

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Applicable international instruments for construction, performance and testing requirements 1

EC Type Examination Certificate

ei DG UV Test EC-Type Examination (Module B) Certificate

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

TFI Report Classification

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

CERTIFICATE OF FIRE APPROVAL

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

Additional reaction to fire classification report No H

ISO INTERNATIONAL STANDARD

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

BS 476: Part 6: 1989+A1:2009

New European Fire Testing Classification for Construction Products

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

DRY CHEMICAL POWDER SYSTEM REQUIREMENTS TO COMPLY WITH THE LATEST IMO IGC CODE AND EUROPEAN COUNCIL CLARIFICATIONS

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS

Classification of Fire Performance of Wall and Ceiling Lining Materials

RESOLUTION MSC.265(84) (adopted on 9 May 2008) AMENDMENTS TO THE REVISED GUIDELINES FOR APPROVAL OF SPRINKLER SYSTEMS EQUIVALENT TO THAT REFERRED TO

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

IMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009

RESOLUTION MSC.61(67) (adopted on 5 December 1996) ADOPTION OF THE INTERNATIONAL CODE FOR APPLICATION OF FIRE TEST PROCEDURES

Abrasion Resistance of Fluoropolymer and polyester Coatings

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

Analysis Report

EC-Type Examination (Module B) Certificate. A.1/3.11 b "B" dass divisions, fire integrity

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

Report VNLF Test Report

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

Notified Body No.: 0575 G U A D N L. SJq

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

CERTIFICATE OF APPROVAL No ME 5085

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

ISO 2685 INTERNATIONAL STANDARD. Aircraft Environmental test procedure for airborne equipment Resistance to fire in designated fire zones

TEST REPORT. Fire tests of construction products in compliance with the following standard:

RESOLUTION MSC.291(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CONVENTION FOR THE SAFETY OF LIFE AT SEA, 1974, AS

IACS RESOLUTION CHANGES (GMO ) BEKİR SITKI TÜRKMEN

FIRE TESTING SERVICES FIRE TESTING SER

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

Transcription:

cd?l DANAK ~ Test Report Reg.no 12. Macroplast UK 8303 B60 Fileno: PFl 7707b Seda! No: 9474 Ref: BP/MPA Ene!.: 7 Henkel KGaA The results relate only to the items tested. The test report should only be reproduced in extenso - in extracts only with a written agreement with this institute. jernholmen 12 DK-2650 Hvidovre Tlf.: 36 34 9000 Fax: 36 34 9001 E-mail: dift@dift.dk www.dift.dk

,. File No. PFl1707b Page 2 of 4 The present test report supersedes DIFT/stest report dated 2004-02-25 under the above file number 1 SPONSOR HenkelKGaA 2 PRODUCT Macroplast UK8303 B60 with hardener UK5400. 3 NAME OF MANUFACTURER c The sponsor is the. manufacturer. 4 LlCENSE/APPROVAL Not issued yet. 5 TESTMETHOD With reference to the of Fire and Security's (DIFT's)"Witnessing fabrication of test specimens" report file No. CP00312, visit conducted 2004-01-15, a test of the sampled material was carried out in accordance with annex to IMO MSC. 61(67): FTPCode, Annex 1, Part 5: "Test for surface flammability"amended by IMOMSC/Circ.1004. Furthermore the test was carried out in accordance with the requirements of the Russian Maritime Register of Shipping, St. Petersburg, cf. Certific'ateof Accreditation of Testing Laboratory No. 97.002.009 valid until16th September 2005.

File No. PFl1707b Page 3 of 4 6 SAMPLE 2004-01-19 DIFT received one bucket of Macroplast UK 8303 B60. The bucket had two individual chambers, one containing 7.7 Kg of resin, the other 1.3 Kg of hardener. The sampie was marked "CP00312/2004-01-15/TN". DIFT prepared five test specimens by mixing the adhesive in ratio 5.9:1, and applied 250 g/m2 to five non-combustible calcium silicate boards each with dimensions 795 x 153 x 10 mm and density 680:t 50 kg/m2, c.f. annex to IMO MSC/Circ. 916. Material specification (stated by the sponsor) Two component solvent free polyurethane adhesive. Further material specification was given by the sponsor and has been filed at DIFT under the above file number. 7 CONDITIONING The specimens were conditioned in accordance with IMO Res.A.653 (16). 8 TEST RESULTS Date of test: 2004-02-24. Pilotflame: Non-impinging. The test results are shown in full detail in enclosure 1. Derived fire characteristics Test No. 1 2 3 Average CFE(kW/m2) 42.8 38.3 38.3 39.8 Qsb(M]/m2) 1.6 1.5 1.6 1.6 Qt(MD 0 0 0 0 qp(kw) 0.7 1.1,1.1 1.0 CFE: Critical flux at extinguishment Qsb : Heat for sustained burning Qt : Total heat release qp : Peak heat release rate

File No. PFl1707b Page 4 of 4 01 Fire and Security Technology 9 CONCLUSION The investigated sampie of Maeroplast UK8303 B60 applied with 250 g/m2 (wet), fulfilsthe surfaee flammability eriteria listed in IMOResolution A.653 (16) for bulkhead, wall and eeiling linings as weil as "IMO FTPCPart 5" and is therefore eonsidered to meet the requirement for low flame spread in eomplianee with regulations 11-2/3.8,11-2/34and 11-2/49of the International Convention for the Safety of Lifeat Sea, 1974, as amended. 10 STATEMENT As the Maeroplast UK8303 B60, as applied, has a total heat release(qt) of not more than 0.2 MJ and a peak heat releaserate (qp) of not more than 1.0 kw, it is eonsidered to eomply with the requirements for smoke and toxicity, set out in "IMO FTPC, Part 2" without further testing, cf. IMO Resolution MSC. 61(67), Annex 2, "Products whieh may be installed without testing and/or approval", 2 "Materials not generating exeessivequantities of smoke nor toxie produets in fire", paragraph 2.2. Note The test results relate only to the behaviour of the test specimens of a produet under the partieular eonditions of the test; they are not intended to be the sole eriterion for assessingthe potential fire hazard of the produet in use. 11 COpy United States Coast Guard DIFT file No. CP00312. ~ ~ ~<--- ~In Ankjer Pauner M.Se.(Civ.Eng.) I Bj0rn Petersen Laboratöry Teehnician Henkel KGaA

.; FileNo. PFl1707b SerialNo. 9474 Enclosure1 SURFACEFLAMMABILITYOF BUlKHEAD,CEILlNGAND DECKFINISHMATERIALS. TESTMETHOD: IMO Res.A,653(16) Material: Macroplast UK 8303 B60 Sponsor: Henkel KGaA Amount of adhesive: 250 g/m2 Date of test: 2004-02-24 Pilot flame: Non-impinging Test resu Its j Wj tj tjsr tjsd Qj Qjsr Qjsd [mm] [kw/m2] [ s ] [ kj/m2 ] specimen 1 2 3 av. st.dev. 1 2 3 av. st.dev. 50 50.50 26 24 25 25 1 1313.0 1212.0 1262.5 1262.5 50.5 100 49.53 30 28 28 29 1 1485.9 1386.8 1386.8 1419.9 57.2 150 46.90 34 31 33 33 2 1594.6 1453.9 1547.7 1532.1 71.6 200 42.75 42 37 38 39 3 1795.5 1581.7 1624.5 1667.3 113.1 250 37.20 300 30.56 350 23.90 400 18.19 450 13.40 500 9.33 550 6.20 600 4.19 650 3.00 700 2.21 750 1.40 1 2 3 av. st.dev. Ignition time ti [s] 18.0 15.0 17.0 16.7 1.5 Heat for ignition Qi [MJ/m2] 1.6 1.5 1.5 1.5 0.1 Extinguishment time te [s] 48.0 44.0 47.0 46.3 2.1 Max. flame spread distance 1 [mm] 200.0 240.0 240.0 226.7 23.1 Crit.flux at exting. CFE [kw/m2] 42.75 38.31 38.31 39.79 2.6 Heat for sust. burning Qsb [MJ/m2] 1.6 1.5 1.6 1.6 0.0 Peak heat release rate qp lkw] 0.7., 1.1 1.1 1.0 0.2 Total heat release Qt [MJ] 0.0 0.0 0.0 0.0 0.0 Heat release per unit area Qa [MJ/m2] 0.7 0.7 0.8 0.7 0.0 Surfaceflammability criteria Bulkhead, wall and ceilinq linin S Floor coverinqs / Prim. deck coverings CFE Qsb Qt Qp CFE Qsb Qt Qp (kw/m2) (MJlm2) (MD (kw) (kw/m2) (MJlm2) (MD (kw) 20.0 1.5 0.7 4.0 7.0 0.25 2.0/1.5 10.0