Installation instruction

Similar documents
Installation instruction

Sauna Heater. Installation and Manual

Operation instructions

Installation of a Brunner fireplace. General Indications

Installation and Operating Manual

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

The Morsø S100 Series

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Installation and Operating Instructions

Fireplace inserts. Model SK1000, SK2000. Installation instructions Care and firing instructions

Installation Instructions. Rayburn 300W Wood Burning Cooker

Relaxed Premium M Relaxed Premium M ENG

Installation & Manual. Model T-25

Operating and installation instructions for Fire Lotus H586

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

USER S MANUAL, MAINTENANCE MANUAL INSTALLATION INSTRUCTIONS

Technical Specifications Panoramic FX1

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

MOS GB INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 1000 VEDEX 1000 M10527 LEK

Installation and Operating Instructions

Duet Premium M Duet Premium M ENG

Installation and user manual CLOSED WOOD FIRES DON T COMPROMISE.

Bergen PRPMXXXX. Smoke Control Kit Additional Installation and User Instructions for use in Smoke Control Areas

Wet stove installation guide

Leading European manufacturer of fireplace stoves and fireplace inserts

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

Corn Flame Energy Corn Stove Model 3000

Riva F40 Cube. Multi-Fuel Free Standing Stove. Installation Instructions. Models: RVF40C. For use in Great Britain and Eire IMPORTANT

Riva Studio Duplex. Inset Convector Cassette. Instructions for Use, Installation & Servicing

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

Installation & Operating Instructions

version 1.2 Made by NARVI Oy Finland Aito 16 / 20 / 24 / 16 VS / 20 VS / 24 VS Installation, user and maintenance instructions

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

GENERAL RULES. Ensure that the installation of your product conforms to all the indications given below. English CHIMNEY STACK

1. Contents Principle General information Parts list Assembly Technical drawing... 18

Riva Studio Duplex. Inset Convector Cassette. Instructions for Use, Installation & Servicing

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Installation and service must be provided by a qualified installer, service agency or the gas supplier.

Installation / User Manual

Clear Installation guide

INSTALLATION AND OPERATION MANUAL

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

Cassette inserts and fireplace doors

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

USER S INFORMATION MANUAL

THE SEVERN. Installation Instructions for Freestanding Severn Stove with Boiler PERFORMANCE RATING

Rocket heater GAMERA

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.

INSTALLATION OPERATION AND SERVICE MANUAL

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

Installation Instructions

ASX7-4-IOM-6 J

ASX7-5-IOM-3 J

INTRODUCTION TO HITZER STOVES INSTALLATION AND OPERATION

HEAT RECOVERY AIR HANDLING UNIT

Duet Premium L Duet Premium L ENG

Fyn Installation guide

Twin Wall Installation Instructions And Maintenance Guide

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Leading European manufacturer of fireplace stoves and fireplace inserts. Fireplace inserts

SAVOY MK2 Model : Technical manual STAUB FONDERIE

STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

FINAL DRAFT FprEN

AS Australian Standard. Domestic solid fuel burning appliances Installation. This is a free 6 page sample. Access the full version online.

Vent Supplement Ultra-80, -105, -155, -230 & -310

Neo. Multifuel Stove Model Neo 1 / Neo 3. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

WOOD FIREPLACE WINDO3 P50. Installation, use and maintenance

Studio. Built-In Convector. Instructions for Use, Installation & Servicing. For use in AU (Australia)

Stockton 7 & 8 Inset Convector Stove

INSTALLATION AND SERVICE INSTRUCTIONS. The biggest Czech producer of fi replace inserts. Accurate and precise design of details

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

Fyn Installation guide

tççç= ÜÉ~íáåÖ çéíáçåë

Instruction manual for downdraft hood

Solution Installation guide

Installation Instructions

READ AND SAVE THESE INSTRUCTIONS

WOOD FIREPLACES, STOVES & INSERTS. WOOD FIREPLACES, STOVES & INSERTS

Masterflamme Convection Wood Stoves Perfect combustion with unique design

VASKA C11. gas -fireplace installation guide

Part 1: Installation Instructions for WAGENER SPARKY (Please keep these Instructions for future Reference)

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

INSTALLATION, USER AND MAINTENANCE MANUAL

Studio. Inset Convector Cassette. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

ZC Kit AGP Pellet Insert

APPUZO RANGE HOOD INSTALLATION

Duet XL /0929. Installation guide

Eastside Installation Guidelines and Operating Instructions January 2018

Transcription:

Installation instruction C i40 www.contura.eu

82 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. Ci40-CPR-130912-SE-2 PRODUCT Product type Type designation Manufacturing number Intended area of use Fuel Insert lit with solid biofuels Contura i40 See rating plate on the insert Heating of rooms in residential buildings Wood MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden CHECKS According to AVCP System 3 European standard EN 13229:2001/AC:2006, EN-13229:2001/A2:2004/AC:2007 Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625, has checked declared performance and issued test report no. RRF-29 13 3402 DECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material Rear: 1 mm Side: 1 mm Follow the given conditions in the installation instructions. Risk of falling embers Pass Emissions from combustion CO 0,07% NOx 91 mg/m 3 Surface temperatures Cleaning options Mechanical durability Emissions of hazardous substances Nominal output Efficiency 81% Flue gas temperature in connector at nominal 328 C output OGC 59 mg/m 3 PM 17 mg/m 3 Pass Pass Pass Pass 7,0 kw EN 13229:2001/AC:2006, EN-13229:2001/A2:2004/AC:2007 The undersigned is responsible for the manufacture and conformity with the declared performance. Niklas Gunnarsson, Business area manager NIBE STOVES Markaryd, September 12, 2013

CONTENTS 83 A warm welcome to Contura. A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new insert. As a new owner of a Contura insert, you have secured a product with timeless design and long service life. Contura also has a combustion process that is both environmentally friendly and efficient, for the best heat production. Read through these installation instructions carefully before installation. Read how to best light your stove in the lighting instructions. List of Contents Technical specifications 84 Important dimensions 85 Prior to installation 85 Installation 94 Chimney 95 Recessing the insert 96 Recess example 97 NOTE: Report the installation of a fireplace to your local authority. The owner of the house is personally responsible for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector. Your local chimney sweep must also be informed about the installation as this will affect the routines for regular chimney-sweeping services. WARNING! The insert becomes very hot During operation, certain surfaces of the insert become very hot and can cause burn injuries if touched. Also, take heed of the strong heat radiated through the door glass. Placing flammable material closer than the safe distance indicated may cause a fire. Smoulder combustion can cause quick gas ignition with the risk of damage to property and personal injury.

84 FACTS Technical specifications Model i40 Output 5-10 kw Nominal output 7 kw Efficiency 81% Weight (kg) 145 (with Thermotte) 115 (without Thermotte) Width (mm) 773 Depth (mm) 424 Height (mm) 1260 Connector diameter Ø1 mm ext. Type approved in accordance with: European standard EN-13229 DIN plus Bauart 1 Part 15a B-VG Test report no: RRF-29 13 3402 SINTEF: 110-0408 Approved for installation in Smoke Control Area by DEFRA General This manual contains instructions about how Contura i40 must be assembled and installed. To ensure the function and safety of the insert, we recommend that installation is carried out by an authorised technician. Our Contura dealers can recommend suitable technicians, information about our dealers can be found at www.contura.eu Instructions for lighting are also supplied with the insert. Read them carefully and keep them safe for future use. Structural support Check that floor joists have the sufficient load capacity for the insert, chimney and construction parts that are used when recessing. Floor plate If the floor under the stove is flammable, it must be protected by a non-flammable material e.g. natural stone, concrete or 0.7 mm thick metal. The floor in front of the hearth opening must be protected against any falling embers using non-flammable material that covers an area at least 300 mm in front and mm along each side of the hatch opening. A toughened glass hearth plate is available as an accessory. Application to local authority Before installing a stove or erecting a chimney, it is necessary for you to make an application for permission to your local authority. Ask your local authority for advice regarding regulations and the application. Heat Strålningsplåt deflector Diffuser Diffusor Counter Motvikt weight Smoke Rökhyllashelf Roster Grate Hearth cladding/thermotte Eldstadsbeklädnad Damper Spjäll Justerbara Adjustable fötter feet Ash-pan Asklåda Type Typskylt plate Connector Anslutningsstos Bottom Bottenisolering insulation

IMPORTANT DIMENSIONS / PRIOR TO INSTALLATION 85 Important dimensions C i40 810 635 425 3 385 355* 200 Ext. Utv. Ø1 Ø 1 13-1370 1205-1225 925-945 85-105 330-3 390 110 55 95 385 170 Tilluftsstos Air Ø Inlet Ø 60 30- Adjustable Justerbar foot fot * Factory setting, prepared for Contura surround Prior to installation Opening the door 1 1 2

86 PRIOR TO INSTALLATION Remove the loose parts from the firebox. The insert is secured to the pallet by the two rails, remove the screws and remove the angle brackets. Reinstall the screws on the legs before moving the insert from the pallet. 3 mm 10 mm

VANADIUM GB PRIOR TO INSTALLATION 87! Check wire routing and remove the transport locking device! 10 mm 10 10 No. 7 CHROME! The hatch runners are lubricated at the factory, with special grease that can withstand high temperatures. This type of grease is usually difficult to find on the market and we recommend contacting a Contura dealer to order this special grease when lubricating the runners.

88 PRIOR TO INSTALLATION Installing the hearth cladding 1 2 3 4 5 6

PRIOR TO INSTALLATION 89 7 8 9 10

90 PRIOR TO INSTALLATION Installing heat defl ectors PH2 1 2 10 mm

PRIOR TO INSTALLATION 91 3 4 PZ2

92 PRIOR TO INSTALLATION Installing Powerstone

PRIOR TO INSTALLATION 93! Install the Powerstone blocks as illustrated. Ensure there is sufficient space for so that the counterweight can move freely. Test by opening/closing the door.

94 INSTALLATION Installation Ensure that the installation meets national and regional regulations. The installation must be approved by an authorized inspection body. Supply of combustion air Supply air from open air must be provided. Combustion air can be provided directly via a duct from outside, or indirectly via a vent in the outer wall of the room where the insert is placed. The amount of combustion air that is used for combustion is approx. 30 m3/h. Some installation alternatives are shown below. The air duct connection on the insert has an external diameter of Ø mm. In hot areas, the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor for example, aluminium tape. It is important that the lead-in, between the pipe and the wall (or floor), is sealed using jointing compound. A 1 m length of condensation-insulated ducting for combustion air is available as an accessory. HK HK HK HK

285 GB CHIMNEY 95 Chimney The insert is type approved for and must be connected to a chimney dimensioned for a flue temperature of 3 C, the external connection diameter is 1 mm. The insert requires a draft in the chimney of at least 12 Pa. The draft is affected both by the length and area of the chimney, and by how well sealed it is. Carefully check that the chimney is sealed and that there is no leakage around soot hatches and flue connections. Note that a flue with sharp bends and horizontal routing reduces the draught in the chimney. The maximum horizontal flue is 1 m, on the condition that the vertical flue length is at least 5 m. It must be possible to sweep the full length of the flue and the soot hatches must be easily accessible. If two fireplaces are connected to the same chimney flue, the stove must be equipped with self-closing door. Rearward connection For the rearward connection it is recommended to use a 45 +45 angle with soot hatch and with the centre at least 285 mm above the connector. It is important that sweeping can be carried out through convection grates or a hatch in the surround. Self-closing door The insert can be supplied with a self-closing door. Loosen the screws and remove the two weights with handle. Position the enclosed panel section on the counterweight and tighten the screws. Check the function, note that during lighting the selfclosing effect increases. x2 10 mm 10 mm

96 RECESSING THE INSERT Recessing the insert When recessing the insert, adjacent walls that are not classed as fire walls, or are considered unsuitable for heat loads must be protected by non-combustible material according to the specification below. All joints on the non-combustible material must be sealed using the manufacturer s recommended method. The area between the insert and the recess must be ventilated according to the specification/dimension diagrams on page 98 When connecting a steel flue, please refer to the particular manufacturer's installation instructions. Observe the safety distance to combustible material required by the steel flue Heat radiation from the hatch is strong and is why combustible material must not be placed closer than 1.5 m in front of the hatch. When recessing, building material must not be in direct contact with the insert due to the thermal expansion of the insert. Note that building regulations apply regarding the area below and in front of the insert, see section Hearth plate. Material requirements The building material must not be combustible. The thermal conductivity coefficient λmay be a maximum of 0.14 W/mK. The thickness of the building material must always be at least mm. In cases where the building material s insulation properties are given as a U-Value, this must be a maximum of 1.4 W/ m²k. List of suitable materials: Aerated concrete λ = 0,12-0,14 Vermiculite λ = 0,12-0,14 Calcium silicate λ = 0.09 Sealing The recess must not go all the way up to the ceiling, leave an air gap of at least 20 mm closest to the ceiling. The recess must be sealed off above the convection exhaust. The seal must be mm above the convection exhaust s upper edge and must be made of mm non-flammable material according to the material requirements above. Use heat-resistant silicone, for example, between the seal and chimney. Convection air The convection air ventilates the surround, cools the insert and transports the hot air out into the room. The effective cross section area on the air intake and exhaust must not be less than the stated values. The air intake must be positioned somewhere between the floor and the bottom of the insert, at the front or on the sides of the recess. The vent must be positioned above the insert s highest point at the front or to the sides of the recess. If the air intake respectively the vent is positioned on the sides, the areas for the left respectively right sides must be the same size to ensure the insert is evenly cooled. Observe the minimum distance up to the ceiling (see diagram on page 98). Convection air in: 600 cm² Convection air out: 600 cm² If the convection outlets are directed upwards the following applies - the recess must be free-standing or placed against a non-combustible wall. - the distance from the air outlet to combustible roof must be at least 7 mm. Note that building regulations apply regarding the area below and in front of the insert, see section Hearth plate. Service Access to the damper and counterweight must be ensured via doors or ventilation grilles in the surround. Connector Rotating connector, can be turned 180 to be centred over the insert, see drawing on page 5.

5 Area ut min. 600 cm 2 Recess example Area in min. 600 cm 2 20 0 20 RECESSING THE INSERT GB 97! max The dimensions are the minimum dimensions, unless otherwise stated. Wall of combustible material 10 10 140 20 Wall of non-combustible material that is not in contact with combustible material and therefore has no minimum thickness requirement. (I 20 min 2300) Chimney breast 800 600 700 10 240 600 Wall of non-combustible material, made of mm aerated concrete in the recess example. 0 (I 10 min 2) 10 240 0 Final inspection of the installation It is extremely important that the installation is inspected by an authorised inspection body before the stove is used. Also read the "Lighting instructions" before lighting for the first time.

98 RECESSING THE INSERT Sealing Avtätning Max 20 5 Max 5 460* 340 Area Area external ut 600 600cm 2 2 Area Area external ut 600 600cm 2 2 2 Area Area internal ut 600600cm 2 2 Area Area internal 600 600cm 2 2 * With Powerstone 7 Max 5 Area Area external ut 600600cm 2 2 Area Area external ut 600600cm 2 2 Area Area internal 600600cm 2 2 Area Area internal 600600cm 2 2 Can be excluded if the chimney breast behind is approved and meets full safety requirements according to the authorized inspection body.! Always observe the safety distances to combustible material required by a steel flue.! The dimensions are the minimum dimensions, unless otherwise stated.

NIBE AB Box 134 SE-285 23 Markaryd Sweden www.contura.eu 811210 IAV SE-EX Ci40-12 2017-05-23 Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice. The current edition can be downloaded from www.contura.eu