Multi-Gas-Controller MGC2

Similar documents
Danfoss gas detection units

Danfoss gas detection units

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

Gas Controller Module GC-06

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

PolyGard 2-channel Gas Controller MGC-03

Sensor unit MC2 with analog output for Freon gases and refrigerants

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Danfoss gas detection Controller unit

Two-Channel Gas Controller

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Danfoss gas detection unit Type GD Heavy Duty

Carbon Monoxide CO Transmitter ADT-X3-1110

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

Combustible Gas Detection and Control System

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

Gas Detection Unit (GDU) GDA, GDC, GDHC, GDHF, GDH

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Carbon Monoxide Transmitter

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Remote alarm indicator and test combination MK2430

Catalog 2018 SAFETY FIRST. Fixed Gas Warning Systems for Buildings, Industry and Marine PERFECT SOLUTIONS FOR GAS ALARM SYSTEMS. Version 11.

Process Alarm Module RTA 421

I/A Series 716C 1/16 DIN Temperature Controller

ZXSe Range Data Sheet

Chillgard Refrigerant Monitor

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Dräger REGARD -1 Control System

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Recalibrate the way you look at gas detection

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Model D12-IR. Digital Gas Transmitter...

User Manual. PolyGard Single Point Controller SPC-43-20XX. Single Point Gas Controller for Refrigerant Gases Serial Number _E_.

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

User Manual. PolyGard Single Point Controller SPC3-11XX. Single Point Gas Controller Serial Number _E_1007. May 2009

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

System 57. An advanced world of intelligent gas detection system management

02/11/2015

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

S5000 Gas Monitor. GMS5000.com

Detection, Protection, Innovation

System 57. An advanced World of intelligent gas detection system management

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Air Check O 2 Deficiency Monitor 0-25%

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Dräger PointGard 2100 Detection of toxic gases and vapours

Panel Mounted Fault Annunciator Series

/8 DIN Level Indicator

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Product Manual SZ1144

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

02/11/2015

Product Manual SZ1145

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

CTT8 TEMPERATURE MONITOR DEVICE

Temperature Controllers

Carbon Monoxide (CO) Gas Detector, 4-20mA or 2-10Vdc

System 800 Addressable Fire Detection & Alarm System

PolyGard Controller LGC/LG2-04. Multi-Point Controller Serial Number S00 User Manual Preliminary Version. August 11, 2006

Dräger REGARD -1 Control System

3M Oldham MX 43 Controller

Fire control panel detect 3004 plus and accessories

T M LIM2010. Line Isolation Monitor (LIM) Technical Bulletin NAE /

MO n : 12JMC rév A

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Carbon Monoxide (CO) Gas Detector, 4-20mA GCO. Automatikprodukter. Oct. 15. Features. Technical Data. Design Features. Application.

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Series Temperature Controller Instruction Sheet

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Pioneer-R16 Gas Monitor Operator s Manual

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Line Isolation Monitor (LIM) LIM2000plus

Air Check O 2 Deficiency Monitor 0-25%

Universal Gas Detector

Touchpoint Pro Flexible Gas Control System

XLH210: controller for gas leak detectors

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Dräger Polytron 7000 Fixed gas detector

CMD420 / CMD421 Series

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

User Manual. PolyGard Single Point Controller SPC Single Point Gas Controller for Combustible Gases Serial Number _E_1008.

VA301C CONTROLLER WITH BACnet OPTION

Annunciator unit. Application

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Beacon 110 Gas Monitor Operator s Manual

Dependable Solutions for Gas Detection

Transcription:

Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants or oxygen. The Multi-Gas-Controller is designed for the connection of max. three analog sensors with 4-20 ma signal, e.g. of the MC2 series. The controller monitors the measured values and activates the alarm relays if the set alarm thresholds for pre-alarm and main alert are exceeded. In addition, the values are provided for direct connection to a superior BMS via an RS-485 interface and also as 4-20 ma output. The SIL 2 compliant self-monitoring function in the MGC2 activates the fault message in case of an internal error as well as in case of a fault at the 4-20 ma input / output current signals. with sensor Other options such as LCD display, three-color status LED, warning buzzer, digital input for acknowledgment or test function, various communication protocols ensure proper adaptation to the wide range of applications in gas detection technology. For convenient commissioning the MGC2 can be pre-configured and parametrised with factory-set defaults. APPLICATION with display The MGC2 is designed for detection and warning of gases in many commercial and industrial applications. FEATURES Internal function monitoring with integrated hardware watchdog Hardware and software according to SIL2 compliant development process Easy maintenance / calibration by replacing the MC2 sensors or via comfortable on-site calibration Modular technology (plug-in and exchangeable) Reverse polarity protected, overload and short-circuit proof Three analog inputs 4-20 ma, e.g. MC2 series Three relays with change-over contact, potential-free max. 240 V AC, 5 A Two transistor outputs, 24 V DC, 0.1 A (plus switching) Serial RS 485 interface with protocol for DGC06, or Modbus protocol as an option Different types of housing with IP 65 Two digital inputs Warning buzzer and status LED for alarm, fault, operation and service (option) LCD display (option) Reset button (option) Operating voltage 230 V AC, with wide range input 100 to 240 V AC (option) UPS (option) Conformity to: o EN 50271 o IEC/EN 61508-1-3 o EN 60079-29-1 ANSI/UL 61010 1 & CAN/CSA-C22.2 No. 61010-1 (optional) Duct mounting kit (accessory): See datasheet SC2 / MC2

Page 2 Aug. 2018 SPECIFICATIONS Electrical Power supply Overvoltage category Power consumption (24 V DC) - Control Board - per sensor (MC2) - horn / warning light Alarm relays (3) Transistor output (2) input (2) Analog input (3) Analog output signal (1) 24 V DC ± 20 %, reverse-polarity protected 24 V AC ± 15 % I Max. 60 ma (1.5 VA), w/o sensor, w/o horn, w/o flashlight Max. 85 ma (2.1 VA) Max. 40 ma (1.0 VA) 240 V AC, 5 A, potential-free, change-over contact (SPDT) 24 V DC / 0.1 A (switching to plus) (only at 24 V DC power supply) Potential-free 4 20 ma overload and short-circuit proof, input resistance 200 Proportional, overload and short-circuit proof, load 500 Ohm 4-20 ma = measuring range 3.0 < 4 ma = underrange > 20-21.2 ma = overrange 2.0 ma = fault Ambient conditions Temperature range -25 C to +50 C (-13 F to +122 F) Humidity range 15-95 % RH not-condensing Pollution degree 2 (indoor use only, and not suitable for wet environment) Altitude up to 1500 m Storage temperature +5 C to +40 C (+41 F to +104 F) Storage time 6 months Serial interface Field bus RS 485 / 19200 Baud Tool bus 2-wire / 19200 Baud Physical Housing type A, C, E Polycarbonate Combustion UL 94 V2 Housing colour RAL 7032 (light grey) Dimension housing (W x H x D) Type A Type C Type E 94 x 130 x 57 mm (3.7 x 5.12 x 2.24 in.) 130 x 130 x 75 mm (5.12 x 5.12 x 2.95 in.) 130 x 130 x 99 mm (5.12 x 5.12 x 3.87 in.) Weight ca. 0.6 kg (1.32 lb.) Protection class (delivery status*) Nema 4X (IP 65) Installation Wall mounting Knockouts for cable and sensor entry Standard 6 x M20/25 Wire connection: input, analog output Power supply, relays Screw-type terminal min. 0.25 mm 2, max. 1.3 mm 2 (24 to 16 AWG) Screw-type terminal min. 0.25 mm 2, max. 2.5 mm 2 (24 to 10 AWG) Directives EMC directives 2014/30/EU Low voltage directive 2014/35/EU CE EN 61010-1:2010 Conformity to: EN 50271 IEC/EN 61508-1-3 EN 60079-29-1 Option: ANSI/UL 61010-1 CAN/CSA-C22.2 No. 61010-1 Warranty * If there are changes to the housing it has to be re-evaluated. 1 year on sensor (not if poisoned or overloaded) 2 years on device

Page 3 Aug. 2018 Options LCD display LCD Two lines, 16 characters each, background highlighted in two colours Operation Menu driven via six push-buttons Power consumption 5 V, 60 ma, 0.3 VA Status LED Colour / mode Red / yellow / green (alarm fault operation - service) Protection class IP 65 Warning buzzer Acoustic pressure > 85 db (A) (distance 0.1 m) Frequency 2300 Hz Protection class IP 65 Power supply 110 / 230 V AC Wide range input 100-240 V AC - 50/60 Hz Output rating type 5 5 VA Output rating type 7 15 VA UPS Power unit with wide range input 100-240 V AC - 50/60 Hz Output rating 15 VA Rechargeable battery 12 V, 0.8 Ah Operating time > 60 min Power supply 12 V DC 12 V DC reverse-polarity protected Power consumption (12 V DC) - Control Board Max. 120 ma (1.5 VA), w/o sensor, w/o WAO - per sensor (SC2 or MC2) Max. 170 ma (2.1 VA) - horn / warning light Max. 80 ma (1.0 VA) SHORT DESCRIPTION OF THE FUNCTION: DIGITAL OUTPUTS WITH THREE RELAYS Action 1 (Alarm1) 2 (Alarm2) Warning light (Alarm 2) Horn (Alarm 2) 3 (Alarm2 + fault) LED Gas signal < alarm threshold 1 OFF OFF OFF OFF ON GREEN Gas signal > alarm threshold 1 ON OFF OFF OFF OFF RED Gas signal > alarm threshold 2 ON ON ON ON ON RED Gas signal alarm threshold 2, but OFF ON OFF after RED button Horn OFF activated delay ON Gas signal < (alarm threshold 2 - ON OFF OFF OFF OFF RED hysteresis) but >= alarm threshold 1 No alarm, no fault OFF OFF OFF OFF ON GREEN No fault, but maintenance due OFF OFF OFF OFF ON GREEN flashing Internal error OFF OFF ON OFF OFF YELLOW Note 1: Status OFF = is configured Alarm ON = or the MGC2 is free from tension. Note 2: Alarm thresholds can have the same value, therefore the relays and/or the horn and flashlight can be triggered together.

Page 4 Aug. 2018 ORDERING INFORMATION MGC2- X X 3 X X X 3 X 0 X FURTHER OPTIONS 0 No further options A Version UL/CSA 61010-1 (only housing type A, C & E) WARNING DEVICES 0 Without built-on warning device DISPLAY 0 Without display 2 With display/keypad ANALOG INPUT 3 3 x Analog input DIGITAL INPUT 2 2 x input 4 1 x input & reset button on the housing OUTPUT SIGNAL ANALOG / BUS 2 RS 485 with DGC 06 protocol 3 Analog output & RS 485 with DGC 06 protocol 5 Analog output & RS 485 with Modbus protocol VISUAL/ AUDIBLE WARNING DEVICES 0 Without visual / acoustic indicator 4 Buzzer & status-led (red, yellow, green) ALARM RELAYS 3 3 x Alarm relays POWER SUPPLY 1* 12 V DC 2 24 V AC/DC 5 100 240 V AC / 24 V DC, 5 VA 7 100 240 V AC / 24 V DC, 15 VA 8* USV 100 240 V AC /12 V DC, 15 VA, 0.8 Ah 9 USV 100 240 V AC /24 V DC, 15 VA, 0.8 Ah HOUSING 0 Without housing A 2 Housing type A 90 x 130 x 57 mm C 1 Housing type C 130 x 130 x 75 mm E Housing type E 130 x 130 x 99 mm P* Door installation housing type P 150 x 96 x 50 mm U* In-wall housing type U 150 x 120 x 80 mm V* In-wall housing type V 145 x 90 x 70 mm W* In-wall housing type W 110 x 90 x 70 mm *only on request 1 Version with display and voltage supply 15 VA only with housing type E 2 Only 1x SC2 or 1x MC2 mountable, w/o optical/acoustical indicator, w/o 100-240 V AC/15 VA, w/o UPS Standard versions: MGC2-C-2-3-0-3-2-3-0-0-0 MGC2-C-7-3-0-3-2-3-0-0-0

4-20 ma Bus_A Bus_B X11 X12 X13 BUS_A BUS_B AO_01 AI_01 AI_02 AI_03 Horn DI_1 DI_2 Flashlight NC P E R F E C T S O L U T I O N S I N G A S A L A R M S Y S T E M S Page 5 Aug. 2018 ELECTRICAL CONNECTION Power Supply s drawn in de-energized mode. Mode = Energized (Alarm ON = OFF) Alarm 1 Alarm 2 Alarm 3 / Fault X1 3 2 1 X2 3 2 1 X3 3 2 1 X4 3 2 1 Multi Gas Controller MGC2 Field Bus Analog Output Analog Output 1 2 3 1 2 3 4 1 2 3 4 5 6 7 1 2 3 1 2 3 1 2 3 MC2 MC2 MC2