Site Requirements. MODEL 2.0 Australia

Similar documents
Site Requirements ADVANTAGE PLUS

SITE REQUIREMENTS 1 USER MANUAL INSTALLATION PACKAGE SITE REQUIREMENTS

Customer Requirements Pre-Installation Instructions

Water Pre-Filtration System Installation Instructions Endoscope Reprocessing Systems

Plumbing fittings should be hand tightened followed by one complete turn with the appropriate wrench.

CER OPTIMA. Endoscope Reprocessing System CER-1 & CER-2 Site Requirements. Introduction. Space Requirements

CER-1 & CER-2 Site Requirements

CER-1 & CER-2 Installation & Testing Instructions

SITE REQUIREMENTS & INSTALLATION DSD-201 & SSD-102

Endoscope Reprocessor Installation Instructions Endoscope Reprocessing System

Attendance Sheet. (List each model reviewed during this session) Print Name Signature Title. Print Name Signature Title.

RELIANCE 400 LABORATORY GLASSWARE WASHER

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

CER OPTIMA. Service Manual. Endoscope Reprocessing System. CER OPTIMA Service Manual

CER-1 / CER-2 (MV-1 / MV-2) (CLM-5001X / CLM-5002VX)

Refrigerated Compressed Air Dryers

Refrigerated Compressed Air Dryers

Refrigerated Compressed Air Dryers

Non-Cycling Refrigerated Air Dryers. HPRplus SERIES 100 to 3000 scfm (170 to 5097 nm 3 /h)

PRE-INSTALLATION GUIDE

G34M Bulletin #69/ August 2003

Chemical Transfer Pump Tube Set and Adapter Instructions

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

hinge right B 1 85 cm + 6,5-7 cm max. height of the device feet B cm B 3 85 cm D 2 75 cm (with a maximum opening angle of 170 )

Heat of Compression Desiccant Air Dryers. HOC SERIES scfm ( nm 3 /h)

IQ/OQ Protocol Installation Qualification/ Operation Qualification

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

Instructions for Use. A-dec 461 Cuspidor with Support Center

Cool IR. Model C104 - Cooling System. Instruction Manual

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

BASIL 6000 TUNNEL CAGE WASHER

Service Parts

MODEL MW200 MODEL MW600 AIR DRYER

Gerber Innovations M Series Laser. Site Preparation & Installation Manual

Service Parts

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Non-Cycling Refrigerated Air Dryers. HPRplus SERIES 100 to 3000 scfm (170 to 5097 nm 3 /h)

Blower Purge Desiccant Compressed Air Dryers IBP SERIES 500-4,300 SCFM

IMPORTANT SAFETY INFORMATION READ ALL...

Quest 105, Dry155, and 205 Dual

HYDROGARD Refrigerated Air Dryers HGD and DES Series

RELIANCE 444 SINGLE-CHAMBER WASHER/DISINFECTOR

Frosty Factory of America, Inc.

The name to vacuum with...

Sub psi SPECIFICATIONS

5) Do not start or stop the unit by inserting or pulling out the power plug.

HV-50 HVOF Thermal Spray System

Service Parts

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Heat of Compression Desiccant Air Dryers. HCD SERIES scfm ( nm 3 /h)

Heat of Compression Desiccant Air Dryers. NRG-LES SERIES scfm ( nm 3 /h)

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

Symphony Plus Pressurized Water Sanitizing Kit P/N

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Service Parts

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

meets medilab Oil-free compressed air for the medical and laboratory market

Installation Manual. PRO Series Ventless Heat Recovery Rack Conveyor Dishwashers LISTED.

A new wave in instrument washing and disinfection Introducing the HYDRIM G4 WD series

OG5000 Ozone Generator Model OG5000B-A. User Manual

254 Nanometer Germicidal UV Disinfection Systems

NGV Fueling Station Dryers. FSD-A, FSD-T, FSD-M and MRS Series Catalog

MCGUIRE AIR COMPRESSORS Compressed Air Dryers. CRN Series. Refrigerated. Leading Technology. MCGUIRE AIR COMPRESSORS

meets medilab Oil-free compressed air for the medical and laboratory market

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

201 Series Dryers Features and Benefits...3 Dimensions...4 How to Order...5 Product Specifications...5

CNC Series Refrigerated Air Dryer CFM

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

2015 Myco Industries, Inc Fax:

Non-Cycling Refrigerated Air Dryers

VHP ARD BIODECONTAMINATION SYSTEM

A new wave in automated instrument washing and disinfection Introducing the new HYDRIM G4 WD series

Ingersoll Rand kw Single Stage Contact-cooled rotary screw air compressors

InstructIons for use A-dec 561 Cuspidor

Refrigerated Compressed Air Dryers

Service Parts

ADSORPTION DRYING: WHY?

Atlas Copco. Refrigerant Air Dryers FX Hz

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

Quest Dry 105, 155, and 205 Dual

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

RELIANCE VISION SINGLE-CHAMBER WASHER/DISINFECTOR

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

RNC Series SCFM Global Air Treatment

IQ/OQ Protocol Installation Qualification/ Operation Qualification SteamScrubber & FlaskScrubber Laboratory Glassware Washers

Compressed Air Products

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Installation Manual. Manual P/N rev. B. PRO Series Standard Rack Conveyor Dishwashers LISTED. Models.

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

20 Series INSTALLATION MANUAL ENG-R00

Transcription:

Site Requirements MODEL 2.0 Australia 1

ADVANTAGE PLUS, MEDIVATORS and RAPICIDE are registered trademark of Medivators Inc. WINDOWS and WINDOWS 7 are registered trademarks of Microsoft Corporation. 50098-608 Rev A 2014 Medivators Inc. All rights reserved. This publication is protected by copyright. Copying, disclosure to others, or the use of this publication is prohibited without the express written consent of MEDIVATORS. MEDIVATORS reserves the right to make changes in the specifications shown herein without notice or obligation. Contact your MEDIVATORS representative or MEDIVATORS customer service for more information. 2

SITE REQUIREMENTS The purpose of this section is to provide the customer with requirements that need to be met to ensure the MEDIVATORS ADVANTAGE PLUS endoscope reprocessor will be properly installed. Applicable Documents ADVANTAGE PLUS Endoscope List and Operator ID Form (PN 50092-380) ADVANTAGE PLUS User Manual (PN 50097-429) It is the responsibility of the customer to meet these requirements to ensure proper installation of the ADVANTAGE PLUS endoscope reprocessor. The ADVANTAGE PLUS endoscope reprocessor will be delivered on a pallet along with multiple boxes. It is important to keep all the boxes received with the ADVANTAGE PLUS endoscope reprocessor together. It is the responsibility of the customer to provide qualified personnel to provide the connections for the ADVANTAGE PLUS endoscope reprocessor to the building supply (Water, Electrical, Drain, Air and Network/Internet) during the installation process. Any deviation from these specifications may cause operational issues that would not be covered by the Warranty. Water Supply Potable water is the minimum standard. The definition of potable water varies considerably therefore local guidelines and regulations for quality of water delivery to health care facilities must apply. ISO 15883-4:2008 requires that all rinse water delivered to the washer/disinfector contain no more than 10cfu/100ml. It is highly recommended that the facility water be analysed to determine if the supplied pre-filter is adequate, and should be done so in line with local regulations. Water temperature requirements: RAPICIDE PA Disinfection : 35oC ± 2ºC RAPICIDE PA Sterilization : 43oC ± 2ºC The water supply must be connected to a thermostatic mixing valve set to provide an on-demand water temperature to meet the requirements. The mixing valve feeds the pre-filter must be accessible and located near the prefilter to aid in adjustment. The mixing valve should include a thermometer followed by a bypass valve to a drain. In order to run both disinfection and sterilization cycles on the reprocessor two mixing valves per reprocessor will be required, one set at 35oC and the other 43oC. The output of the two mixing valves should feed a 3 way valve,that is accessible by the operator, to supply the correct water temperature to the prefilter. The incoming waterline must be a minimum of 15 mm ID providing a flow rate of 5 L/min and a water pressure of 2.75-6 bar. Water consumption is approximately 30 liters/cycle for a standard endoscope disinfection cycle, 49 liters/cycle for an endoscope disinfection cycle with a detergent wash, and 68 liters/cycle for an endoscope disinfection cycle with two detergent washes. Water consumption for the ADVANTAGE PLUS endoscope reprocessor will vary depending on the incoming water temperatures. The reprocessor will extend the initial flush to allow the water to come up to temperature to meet the minimum required temperature of the disinfectant. Ensure water hardness is less than 200 ppm (12 gpg) for optimal performance. Maximum NTU 0.2/200ppm. The pre-filter assembly has the dimensions of 66 cm H x 97 cm W x 15 cm D, is wall mounted and needs to be within 1.5 meters of the ADVANTAGE PLUS endoscope reprocessor. The incoming water connection to the prefilter assembly is 1/2 NPT on the right hand side. All fittings and hoses for the output of the pre-filter assembly are included. A shut-off valve must be installed before the pre-filtration system. It is important that the valve be mounted within reach of the operator. The MEDIVATORS endoscope reprocessors do not require backflow protection for the incoming water supply, nor is a backflow protection device installed in the reprocessor. If building or plumbing codes require backflow protection, then please consult your local codes, standards and/or guidelines, for applicable requirements. 3

Drain A drain system capable of draining 12 L/min, less than 46 cm from the floor and vented will ensure the proper operation of the ADVANTAGE PLUS endoscope reprocessor. The supplied drain line has a 2.5 cm ID, 3.5 cm OD. Air Supply The ADVANTAGE PLUS system may be provided with an air compressor that requires a dedicated circuit. If the ADVANTAGE PLUS model purchased did not include the air compressor, the system may utilize house compressed air (dry, oil free) which must meet these required air pressure specifications:4 to 10 bar with a minimum flow volume of 0.71 L/s, maximum particle size is 5 microns, maximum dew point is 7 C, maximum oil concentration is 5 mg/m 3. Air usage is approximately 65 liters per cycle. A 6 mm ID flexible air hose (EPDM, braided, 10 bar minimum) is required to connect the ADVANTAGE PLUS to the house air. This is not supplied with the ADVANTAGE PLUS endoscope reprocessor. The hose connects to a barbed fitting on the back of the ADVANTAGE PLUS endoscope reprocessor. Electrical Supply 240 VAC ± 10%, single phase, 50/60 Hz, 1000watts, 15 Amp GPO A GFI or RCD protected outlet should be located within the operator s reach. Power consumption is 150 watts at idle, 400 watts during a cycle in one basin, 600 watts during a cycle in both basins, and a nominal peak of 1000 watts. The ADVANTAGE PLUS endoscope reprocessor can operate uninterrrupted with power losses up to 0.5 seconds. Power losses greater than 0.5 seconds without proper shutdown may produce system alarms and system shutdown. A UPS with a minimum rating of 1500 VA/865 watts is highly recommended. The role of the UPS is to solely protect the computer and will allow the ADVANTAGE PLUS endoscope reprocessor to operate for a short period of time without power allowing for an orderly shut down of the computer in the event of a power outage. Heat Load Idle: 500 BTU/hr Cycle (1 basin): 1400 BTU/hr Cycle (2 basins): 2000 BTU/hr Ventilation It is the Customer s Responsibility to ensure the room is in compliance with this requirement. This is not a requirement of the ADVANTAGE PLUS endoscope reprocessor but of the chemicals that are used for disinfection. It is a health and safety requirement to have a minimum of 10 air changes per hour in the room. During cycle operation and the chemical heating process, chemical vapour may be produced. The air exchange will minimize staff exposure to chemical vapours. A 10 cm flexible duct may be connected from the back of the ADVANTAGE PLUS endoscope reprocessor to the facility s exhaust system to aid in fume extraction. A minimum of 11.8 L/s at 62.25 Pa static pressure is required to properly vent the ADVANTAGE PLUS endoscope reprocessor. The ADVANTAGE PLUS endoscope reprocessor may also be supplied with an active vapor management system to aid in chemical vapor management. Please refer to the purchase order to determine the correct configuration of the ADVANTAGE PLUS endoscope reprocessor. Dimensions The ADVANTAGE PLUS endoscope reprocessor physical dimensions are 175 cm H x 124 cm W x 79 cm D, weight 180 kgs. Additional space should also be considered if installing an external UPS If the optional air compressor is installed, the ADVANTAGE PLUS endoscope reprocessor will need an additional space at the back or side of the unit. Alternately, the compressor may be installed remotely (in an adjacent room, closet, wall space). 4

Space is required on either side of the unit (approximately a combined 30 cm) for easy access to the internal components. If this is not available, the ADVANTAGE PLUS endoscope reprocessor contains a base with casters allowing the system to be moved. There should be adequate room for the ADVANTAGE PLUS endoscope reprocessor to be moved for access to accommodate maintenance. Endoscope & User Information To ensure a smooth and trouble-free installation, the customer must supply a complete list of users and endoscopes that will be reprocessed in the ADVANTAGE PLUS endoscope reprocessor. Fill out the ADVANTAGE PLUS Endoscope List & Operator ID form (PN 50092-380). Network/Remote Access The ADVANTAGE PLUS endoscope reprocessor is equipped with a PC based computer running Windows 7 which will allow full networking along with the capability of remote diagnostics. To allow for remote diagnostics an internet connection is required. This is highly recommended. Internet connection is the responsibility of the customer. This checklist should be use to ensure the installation site meets the required specifications. If all specifications are met, the site is suitable for the installation and use of the ADVANTAGE PLUS Automated Endoscope Reprocessor. 5

124 cm 114 cm Figure 1. Front & Back Dimensions 91 CM 79 CM 62" 157 CM (l57cm) 114 CM 99 CM Figure 2. Side Dimensions & Clearance 6

SITE REQUIREMENTS Potable water is the minimum standard. Local guidelines and regulations must be followed Minimum flow rate 5 L/min with a pressure of 3 to 6 bar Water Supply Water Temperature meets the requirements of the disinfectant chemistry used. The mixing valve must be accessible Hardness, less than 200 ppm (12 gpg), 0.2 NTU Pre-filter wall space 66 cm H x 97 cm W x 15 cm D Drain 12 L/min, less than 46 cm from the floor, vented Air Supply Electrical Supply Ventilation Unit Dimensions Included air compressor, adds 28 cm to depth of unit House compressed air requirements: (dry/oil free) 4 to 10 bar, minimum flow volume of 43 L/min, maximum particle size is 5 microns, maximum dew point is 7 C, maximum oil concentration is 5 mg/m 3 240 VAC ± 10%, single phase, 50/60 Hz, 1000 watts, 15 Amp GPO GFI or RCD protected outlet, accessible by user A minimum of 10 room air exchanges per hour Optional ventilation system available, adds 18 cm to the depth 157 cm H x 124 cm W x 79 cm D, 180 kgs. Add 30 cm of open space to the total width to aid with service access Endoscope List ADVANTAGE PLUS Endoscope List & Operator ID form (50092-380) completed Remote Access Internet connection (recommended) By signing below Customer acknowledges that (1) Customer reviewed these Site Requirements for the MEDIVATORS Reprocessor(s) listed on the face of this document; (2) Customer is solely responsible for meeting each of the specifications and requirements set forth in these Site Requirements to ensure proper installation and performance of the reprocessor(s); (3) Customer is able to meet each of these specifications and requirements; and (4) the failure of Customer to comply with these Site Requirements and any deviation from the specifications set forth herein may compromise the functionality of the reprocessor(s) and/or may cause operational issues, which will not be covered by the Medivators Inc. warranty and are hereby disclaimed by Medivators Inc. Facility Representative Title Signature Date Email 7

Distrbuted in Australia: C.R. Kennedy & Company Pty Ltd 300 Lorimer Street, Port Melbourne, Victoria, 3207 Tel: +61 3 9833 1577 www.crkennedy.com.au/medical Manufactured in the USA by: Medivators Inc. 14605 28th Avenue North Minneapolis, MN 55447 USA Toll Free: +1.800.444.4729 8 www.medivators.com Medivators BV Sourethweg 11 6422PC Heerlen The Netherlands Tel: +31.45.5.471.471 Cantel Medical Asia/Pacific Pte. Ltd. 1A International Business Park #05-01 Singapore 609933 Tel: +65.6227.9698 Medivators Beijing Representative Office Room 708, 7th Floor Kaiheng Center, Block B No. 2 Chaoyangmennei Street Dongcheng District, Beijing China 100010 Tel: +8610.6567.8446