QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Similar documents
QAW70. Room Unit. Building Technologies. for use with heating controllers

Room Unit. Building Technologies SYNERGYR

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

RVL470. Heating Controller. Use. Functions. Series B

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Use. Functions. Key function. Other functions

RVP310. Heating Controller. Building Technologies HVAC Products

Self-learning Room Temperature Controller

RVL481. Heating Controller. including d.h.w. heating

Self-learning Room Temperature Controller

PRELIMINARY EDITION

Self-learning Room Temperature Controller

REA22 Room Temperature Controller

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller

RVL480. Heating Controller

Room Temperature Controller

RVL479. Heating Controller. for use with a partner unit

Room Temperature Controller

G a

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

Room Units and Sensors for Use in Heating Plants. Siemens Building Technologies HVAC Products SIGMAGYR. Type summary

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

Operating Instructions

District heating controller

Room Temperature Controllers

Room Temperature Controller with LCD

Room Temperature Sensors

for relative humidity and temperature with calibration certificates

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

No. Icon Name Function

District heating controller

Digital Room Thermostat for Heating Applications with 7-Day Time Program

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Room Temperature Controller

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail)

Preliminary Release. Room Temperature

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

for relative humidity and temperature

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

Heating and D.h.w. Controller RVL482 Basic Documentation

Immersion Temperature Controller

RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation

Room Air Quality Sensors

District Heating Controller

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

for relative humidity and temperature

RVL47. Heating Controller. Installations Instructions. Installation

Operating Instructions

Use. For 2-pipe fan coils

Room thermostat with 24-hour time switch and large LCD

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Control solutions Biofloor

Semi flush-mount room thermostats

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Room thermostat with Auto Timer, Option External Input

QAA Room Unit for Boiler Control with OpenTherm Interface Basic Documentation. Siemens Building Technologies Landis & Staefa Division

Duct Temperature Sensors

Room thermostats with LCD for wall mounting

Room thermostat with Auto Timer, Option External Input

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Room Temperature Sensors

RVP340 Heating controller for 1 heating circuit RVP350 and RVP351 Heating controllers for 1 heating circuit and d.h.w. Basic Documentation

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Room thermostat with Auto Timer, Option External Input

Room thermostat with Auto Timer, independent DHW

Room Unit for Boiler Control QAA User manual. Building Technologies. With OpenTherm Interface

Semi flush-mount room thermostat

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Heating Controller. Building Technologies HVAC Products. Synco 700

Room thermostat with Auto Timer, Option External Input

Central apartment unit

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

ECL Comfort V a.c. and 24 V a.c.

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Boiler Sequence Controller

ECL Comfort V a.c. and 24 V a.c.

Document # R01

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Frost Protection Thermostat

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Wall-mounted room thermostat with LCD

Room Temperature Sensor

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Room air quality sensors

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

RF Programmable Room Thermostat User Instructions

RVA Heating Circuit or Primary Controller Basic Documentation. Siemens Building Technologies Landis & Staefa Division

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

TEC2100 Series Networked Thermostats

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

RAB21 RAB21.1. For two-pipe fan coils

Central apartment unit with QAX913 consumption data acquisition

Transcription:

1 37 Room Unit for use with heating controllers Digital, multi-functional room unit for the convenient operation of heating controllers from the living room. A setpoint knob and an economy button allow straightforward adjustment of the room temperature setpoint. The unit features a 7-day heating program, adjustable temperature setpoints, operating mode selection and an info button. Use Depending on the type of heating controller used, the is specifically suited for single-family homes holiday houses Functions Ergonomic and function-specific assignment of operation to 3 operating levels Info button for fast retrieval of important information Buttons for direct selection of operating mode Occupancy button for influencing the heating system temporarily or continuously Setting knob for straightforward readjustment of the room temperature setpoint Entry of room temperature and d.h.w. temperature setpoints Heating program with 3 heating periods per day; each day can be individually selected Holiday function CE2N137E 0.02.2002 Siemens Building Technologies HVAC Products

Resetting the parameters to their default values PPS interface for the heating controller (with selectable device address) Protection of setting values against tampering (operating lock) Connection facility for an external switch (telephone switch) Connection facility for an external room temperature sensor Selectable display format for the setpoint (absolute / relative) Ordering When ordering, please give type reference. If an external room temperature sensor is required, it must be ordered as a separate item. Equipment combinations Suitable heating controllers The is suited for use with all types of heating controllers from Siemens HVAC Products featuring a PPS interface. External sensor Room temperature sensor: QAW44 Mechanical design The room unit consists of base and operating section. The base can be mounted and wired before the operating section is fitted. Casing and base are made of plastic. The major plastic components bear the material references to facilitate environmentalfriendly disposal. Operating elements 1 2 3 4 7 8 AUTO C 1 Display 2 Display occupancy button 3 Info button 4 Operating mode button automatic mode Operating mode button manual operation Operating mode button standby 7 Cover 8 Temperature setting knob 9 Occupancy button 9 2273Z01 Display 9 10 1 2 3 0 4 8 12 1 20 24 8 7 C 2312Z01 4 1 Digits, clock 2 Heating program 3 Units ( C) 4 Display occupancy button Outside temperature Room temperature 7 Holiday function 8 Operating mode 9 Line number 10 D.h.w. temperature 2/

Technical design Operating levels Info button Operating modes Occupancy button The features ergonomic and function-specific assignment of operation to 3 operating levels. Operation by the end-user: - Unit cover closed - Operation via info button, operating mode buttons, occupancy button and setting knob for setpoint readjustments Programming by the end-user: - Unit cover open - Programming via the 4 programming buttons on operating lines 1...17 Service level: - Unit cover open - This level can only be accessed by pressing a certain combination of buttons. Parameterization / programming is made possible via 4 programming buttons on operating lines 1...8 Using the info button, the end-user can retrieve the following key data: - Weekday and time of day - Outside temperature - Time of day and room temperature The value selected last is maintained on the display. Three buttons are used to select the 3 available operating modes: - Automatic mode (change between the nominal room temperature and the reduced temperature according to the time switch settings) - Manual operation (nominal room temperature or reduced room temperature continuously) - Standby (frost / holiday temperature) The occupancy button is used to switch from the nominal room temperature to the reduced room temperature, and vice versa. The action depends on the selected operating mode. - Automatic mode: changeover is only temporary; after the next switching point of the heating program, the controller will resume operation according to the settings made - Manual operation: changeover is on a continuous basis until the button is pressed again Setpoint readjustment Setpoints Heating program Holiday function Default values The temperature setting knob can be used to readjust the nominal room temperature setpoint by +/- 3 K. If required, the setting knob s readjustment range can be mechanically limited. The following setpoints can be entered on the unit: - Nominal setpoint of the room temperature - Reduced setpoint of the room temperature - Setpoint of the d.h.w. temperature The heating program is provided by a 7-day time switch. Each day may have a maximum of 3 heating periods whereby each weekday can be individually programmed. The heating program of the current weekday appears on the display in graphic form. When the holiday period starts, the duration in days can be entered. During the holiday period, the room temperature is maintained at the standby level, ensuring protection against frost. If active, the holiday function is shown on the display. The temperature setpoints, the heating program and the holiday function can be reset to their default values at any time. 3/

PPS interface Operating lock External sensor External switch Display of setpoint For heating controllers that operate 2 room units via their PPS interface, the device address can be set on the. On the service level, an operating lock can be activated. When activated, it is no longer possible to change operating lines. The can also be used with an external temperature sensor. The authority of that sensor can be set to between 0 and 100 %. The use of an external switch allows changeover of the operating mode by some other device (e.g. a telephone switch). On the, it is possible to select whether the reduced room temperature or the frost / holiday mode temperature shall be maintained when the switch has closed its contact. With analog heating controllers only frost / holiday mode temperature is possible. The operating action of the switch can also be selected. It is possible to select whether display of the setpoint shall be absolute or relative. Notes Engineering All connection terminals carry extra low voltage The local regulations for electrical installations must be complied with Sensor cables should not be run parallel to mains cables The room unit should be installed in the main living room If the control system uses room temperature influence, the room unit should be installed in a room that is representative of the entire house (reference room). If that room is equipped with thermostatic radiator valves, they must be set to their fully open position The mounting location should be such that the room unit can sense the room temperature as accumrately as possible. This means that it should not be exposed to direct solar radiation or to other heat or refrigeration sources The room unit should be fitted about 1. m above the floor The room unit can be fitted on most commercially available recessed conduit boxes or directly on the wall Commissioning Every unit is supplied with mounting and commissioning instructions 4/

Technical data Operating voltage DC 10... 1 V Perm. ambient temperature Transport and storage 2...+ C Operation 0...3 C Degree of protection IP 30 to EN 0 29 (when mounted on a closed wall) Safety class III to EN 0 730 Overvoltage protection: max. permissible voltage Terminals D1/D2 24 V (PPS interface) Terminals D3/D4 (sensor / switch) 13... V Room temperature sensor Time constant 10 min Coupling to the wall 0 % Measurement range 0... 32 C Perm. cable lengths to the heating controller (PPS interface) Copper cable 0.2 mm 2 max. 2 m Copper cable from 0. mm 2 max. 0 m Perm. cable lengths to the external switch or sensor Copper cable 0. mm dia. max. 20 m Copper cable from 1.0 mm 2 max. 0 m Product safety Automatic electrical controls for household and similar use Special requirements on energy controllers EN 0 730-1 EN 0 730-2-11 CE conformity to EMC directive Immunity Emissions Low voltage directive Safety Reserve of clock Weight (net) Colour of front 89/33/EEC EN 0 082-2 EN 0 081-1 73/23/EEC EN 0 730 min. 12 h 0.22 kg RAL 9010 (pure-white) /

40, 143 137M01 Connection diagrams With an external QAW44 sensor QAW44 M MD A N1 With an external switch (remote telephone switch) S1 M MD A N1 4 3 D4 D3 2 D2 1 D1 137Z03 4 3 D4 D3 2 D2 1 D1 137Z04 N1 = controller D1...D4 = terminals of N1 = controller D1...D4 = terminals of S1 = external switch Dimensions 30 30 30 28 4,2 137M02 30 28 97 34 41 28 28 12 80 / 1999 Siemens Building Technologies Ltd. Subject to alteration