Standard automatic switch 1.1 m, Standard automatic switch 2.2 m

Similar documents
System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard

System 2000 Automatic control switch 2 Standard. 1 Safety instructions. 2 Device components. 3 Function. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

Automatic switch attachment Standard Installation Instructions

UP 258E11 OPTISENS OFFICE

Presence detector Komfort attachment Installation Instructions

Dimming expertise LED UNIVERSAL ROTARY DIMMER

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

11,1 30. Ordering data

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

DALI MSensor 02 Multi-sensor for DALI system

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Detailed operating instructions

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

Detailed operating instructions

Description of the application programme for KNX occupancy detectors version 3.1

DALI MSensor 02 Multi-sensor for DALI system

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Operating instructions

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

Connections, displays and operating elements C D E G H. Installing the control unit

Product and functional description

User Manual 120/240/300 Outdoor Motion Detector

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Product and Applications Description

2. Safety. 4. Function

Data sheet. Function description. Benefits

Product and Applications Description

Connections, displays and operating elements E F. 20s 3min

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

Tri-level Control HF Sensor

360º Surface Mount Ceiling PIR Light Controller

18W Round LED Wall/Ceiling Light with Microwave Sensor

SCS motion sensors Surface/wall mounting - PIR

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

DIMAX DIMAX 534 plus D GB F I E nl. Installation and operating instructions Universal dimmer. DIMAX 534 plus

Busch-Watchdog presence. Overview and applications of presence detectors.

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

"Options" Sensor Module

ASD 535 Aspirating smoke detector

60W Multi PIR Bulkhead

FlowJam Bulk Flow Detection

IP65 High Bay Dual Sense Sensor

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

1. Basic safety information 3 2. Proper use 3

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

LUXOMAT Application examples for electricians and planners

Devices for Special Applications

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

IP65 High Bay Dual Sense Sensor

12W Round LED Wall/Ceiling Light with Microwave Sensor

compact office 24V compact office 24V Lux

0701 CO Light, HVAC, Monitoring, Brightness

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Detector switch - Dual Tech

Gira Sensotec / Gira Sensotec LED Motion detector, orientation light and contactless switch in one

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

LOS SUPER CEILING SENSOR Installation Manual

Detector switch - Dual Tech SCS

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

Movement controller comfort, Flush-mounted (Up) xx, xx

DIMAX DIMAX D GB F I E NL. Installation and operating instructions Universal dimmer DIMAX 532. Minimum DIMAX 532.

PresenceLight 180 PresenceLight 360

Compact Movement Activated Sensor Installation Instructions

Controller LED X-Dimmer 3F

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

Movement and presence detectors 10 A. 18 Series. Type Type Type Since 1954, light when you need it

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

OPERATING INSTRUCTIONS

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

Remote alarm unit Art. Nr.:

Info-Display xx

Mounting instructions Genius Radio

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

False Ceiling HF Sensors

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

Infrared Flame Detectors

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Silvento concealed variant clamped-ventilator - Replaces Skalar-; Skalar-V...; Skalar-2V... - Installation directions - Please pass on to the user -

Model: PDFM1500. Installation & Operating Instructions 360º Flush Mount Ceiling PIR Light Controller

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

360 Surface Mount Ceiling PIR Light Controller

Transcription:

Standard automatic switch 1.1 m Art. no...17180.. Standard automatic switch 2.2 m Art. no...17280.. User manual 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock. Always disconnect before carrying out work on the devise or load. In so doing, take all the circuit breakers into account, which support dangerous voltages to the device and or load. Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load is not electrically isolated from the mains even when the device is switched off. Do not press on the sensor window. Device can be damaged. The device is not suitable for use as a burglar alarm or other alarm. These instructions are an integral part of the product, and must remain with the end customer. 2 Intended use Automatic switching of lighting depending on the heat motion and ambient brightness Operation with flush-mounted insert for dimming or switching or 3-wire extension from LB management Wall installation on flush-mounted insert Product characteristics Extension of the detection area in combination with 3-wire extension Operation with 2-wire or 3-wire extension, rotary dimmer extension or push-button Selectable brightness threshold Selectable sensitivity Fixed run-on time Switch on with last saved brightness or saved switch-on brightness, with dimming insert Switch-on brightness can be saved permanently via extension, with dimming insert Dimming light via extension with dimming insert Motion detector cover 1.10 m Screen for limiting the detection area Automatic operation The device detects heat motions of people, animals and objects. The light is switched on if a person enters the detection area and the brightness is below the set threshold. The run-on time restarts with each detected motion. The light is switched off, if: no more movement is detected in the detection area and the run-on time has elapsed or the ambient light is too bright and the run-on time has elapsed. To avoid any switch-on caused by a cooling illuminant, no movement signals are evaluated for a brief lockout time after switching off. The motion detector adjusts itself to the ambient conditions to keep the time as short as possible. 32599603 1 / 10

Behaviour after a mains voltage failure After mains voltage return, the device performs a self-test for a maximum of 60 seconds. After the self-test has been completed, the device is ready for operation. The following applies during the self-test: The load is switched on. Movements are not detected 3 Operation Precondition: A 2-wire or 3-wire extension with button cover or a push-button is connected. Multiple extensions can be combined with each other. Operation with the rotary dimmer extension is described in the rotary dimmer extension instructions. Switching on light for the duration of the run-on time Press the button cover or push-button for less than 0.4 seconds. Light is switched on depending on brightness and motion. Movements are evaluated according to the brightness and prolong the run-on time. If the button cover or push-button is pressed again in the switched-on state, the run-on time is restarted. In combination with a dimming insert, switch-on brightness is switched on again. Dim the light Only in combination with a main device with a dimming insert. Press the button cover at the top or bottom or the push-button for longer than 0.4 seconds. Light becomes brighter or dimmer as far as the respective limit value. Push-button: The dimming direction is changed with each new long actuation. Save switch-on brightness Only in combination with a main device with a dimming insert. In the state as supplied, the switch-on brightness is set to maximum brightness. Set light to the required brightness. Press the button cover over entire surface for longer than 4 seconds. Switch-on brightness is saved. For confirmation, the light is switched off briefly and switched on again. An push-button cannot be used to save the switch-on brightness. Delete switch-on brightness Only in combination with a main device with a dimming insert. Press the button cover briefly: Light switches on at the saved switch-on brightness. Press the button cover over entire surface for longer than 4 seconds. The switch-on brightness is deleted. On switching on, the dimming insert switches to the last set brightness value. For confirmation, the light is switched off briefly and switched on again. A push-button cannot be used to delete the switch-on brightness. 4 Information for electrically skilled persons DANGER! Mortal danger of electric shock. Disconnect the device. Cover up live parts. 32599603 2 / 10

4.1 Fitting and electrical connection Motion detection The detection of heat sources through a motion detector and thus the extent of the detection field is influenced by the following criteria: Geometry of the detection field, assembly height and set sensitivity (Figure 1) up to (Figure 8) Direction of movement: If motion detector passes tangentially, this results in a heat signal which can be evaluated well. If movement is radial to the sensor, the heat signal is smaller and thus harder to evaluate, resulting in a smaller range. The following specifications on the extent of the detection field are general guide values. Discrepancies can occur depending on the installation environment and the intensity of the heat motion. Motion detector cover 1.10 m detection field and range Figure 1: Motion detector cover 1.10 m detection field and installation height Figure 2: Range with tangential direction of motion motion detector cover 1.10 m 32599603 3 / 10

Figure 3: Range with radial direction of motion motion detector cover 1.10 m Motion detector cover 2.20 m detection field and range Figure 4: Motion detector cover 2.20 m detection field and installation height Figure 5: Range with tangential direction of motion motion detector cover 2.20 m, mounting height 2.20 m 32599603 4 / 10

Figure 6: Range with radial direction of motion motion detector cover 2.20 m, mounting height 2.20 m Figure 7: Range with tangential direction of motion motion detector cover 2.20 m, mounting height 1.10 m 32599603 5 / 10

Figure 8: Range with radial direction of motion motion detector cover 2.20 m, mounting height Selecting installation location 1.10 m Select a vibration-free installation location. Vibrations can lead to unwanted switching. To achieve optimum range, choose an installation location that is tangential to the direction of motion. Avoid interference sources in the detection area. Interference sources can trigger the motion detector, e.g. heat sources such as heating units, outlets from ventilation openings or air conditioners, copiers, printers, coffee machines, draughty doorways, animals etc. Fitting the cover Connecting and mounting the FM insert properly (see flush-mounted insert instructions). Further installation steps are necessary to ensure the degree of protection IP 44 (see Seal set instructions). Fit the cover with frame on the flush-mounted insert. Expanding the detection field To expand the detection field, connect a 3-wire extension with motion detector cover. The main device also evaluates signals of the extension and, if necessary, switches the lighting on. Limiting the detection field motion detector cover 1.10 m The detection field can be limited using a panel (Figure 9). Figure 9: Limiting the detection field motion detector cover 1.10 m 32599603 6 / 10

Mounting the panel Figure 10: Dismounting the cover Figure 11: Dismounting of design cover Figure 12: Panel mounting, series CD/LS and A Series CD, LS Removing the cover (1) (Figure 10). Use a screwdriver to carefully remove the design cover (Figure 11). Mount the cover for the left or right side of the device (Figure 12). Series A: Mount the cover from the front on the left or right side of the device (Figure 12). 32599603 7 / 10

4.2 Commissioning Make settings Figure 13: Adjuster motion detector cover 1.10 m Figure 14: Adjuster motion detector cover 2.20 m The adjusters for brightness threshold and sensitivity are located behind the cover (1) of the motion detector cover 1.10 m and on the rear of the motion detector cover 2.20 m. Using a screwdriver, carefully remove the cover (1) (Figure 11). The run-on time cannot be changed. Setting the brightness threshold Set the brightness threshold on the covers of the main device and all extensions. Different values can be set on the main device and extensions. There are 4 defined values for the brightness threshold. In setting Ư, the motion detector operates independently of the brightness (day operation). Setting ư for stairways according to DIN EN12464-1, 2003-3. Turn adjuster (2). Setting the sensitivity Sensitivity can be set in 4 levels to minimize faulty switching. Turn Sens. (3) adjuster. Testing the detection area Make the test settings. For this, turn adjuster (2) to Test. The motion detectors operates independently of the brightness and switches on for approx. 1 second when motion is detected. The sensitivity setting remains intact. 32599603 8 / 10

5 Technical data Ambient temperature -20... +45 C Storage/transport temperature -25... +70 C Degree of protection IP20 Brightness setting approx. 5... 1000 lx and day operation Sensitivity 25, 50, 75, 100 % Run-on time approx. 2 min Installation height Art. no...17180.. 1.10 m Art. no...17280.. 1.10 m / 2.20 m Detection angle 180 6 Troubleshooting Motion detector does not switch on Cause 1: The ambient brightness is greater than the adjusted brightness threshold. Set brightness value (see Commissioning chapter). Cause 2: Motion detector does not detect any motions. Check detection area for any obstacles. Motion detector switches on without motion Cause: Motion detector detects heat motions. Pay attention to interference sources such as heaters, fans, air-conditioners and cooling illuminants in the detection area. Motion detector switches off despite motion Cause: The ambient light is too bright and the switch-off threshold was exceeded. Switch on motion detector. Motion detector does not switch off after the set run-on time has elapsed Cause: Motion detector detects motions constantly. Pay attention to interference sources such as heaters, fans and air-conditioners in the detection field. 7 Accessories Sealing kit for automatic switch 2.20 m AS..50DS 8 Warranty The warranty follows about the specialty store in between the legal framework as provided for by law 32599603 9 / 10

ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle GERMANY Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-2 04 kundencenter@jung.de www.jung.de 32599603 10 / 10