Telecom Fuses. Benefits. Features. Applications

Similar documents
PolySwitch TS600 Overcurrent Protection Devices

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

DATASHEET PolySwitch RKEF Devices

Gas Discharge Tubes. Features: Benefits: Applications:

Gas Discharge Tubes GTCX25-XXXM-R02 Series

Gas Discharge Tubes GTCX28-XXXM-R05 Series

Specification Status: Released

Specification Status: Released


Specification Status: Released

PolySwitch Telecommunications and Networking Resettable Devices

Specification Status: Released

RUE Selection Guide and Product Data. RUE Selection Guide

Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors

Specification Status: Released

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

PolySwitch Telecommunications and Networking Resettable Devices

PolySwitch Surface-mount Resettable Devices

This document provides assistance with the selection of elements of the C5C copper pairs connection system. It includes the following sections:

Multi Layer Varistor Overvoltage Protection Device

Z-PACK TinMan 85 ohm Connector Overview

Introducing Hermaphroditic Blade and Receptacle Connector

Specification Status: Released

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

Seal Kits for BUDI Enclosures

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

TE Connectivity's AMP NETCONNECT Cable Management

M7100 Pressure Transducer

DP86 Constant Voltage with Fitting

RayClic Connection System

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

PolySwitch Surface-Mount Resettable Fuses

and Product Data VTP Selection Guide

MSP100 Pressure Transducer

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Applications. Application Summary 41

D5100 Industrial Differential Pressure Transducer

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

RF one-step BNC/TNC connectors for coaxial cable termination

U5700 Submersible Liquid Level Pressure Transducer

Standard SPECIFICATIONS FEATURES APPLICATIONS

Introducing SlimSeal SSL Connector

MSP100 Pressure Transducer

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

MODEL 834M1 ACCELEROMETER

AquiTron. AT-WM Water Monitor DATA SHEET

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

D5100 Industrial Differential Pressure Transducer

M5800 Pressure Transducer with Rotatable Display

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

Gardian W51. Approvals

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

TraceTek TT1000 Modular Sensing Cable

Sub psi SPECIFICATIONS

M5200 Industrial Pressure Transducer

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

M5800 Pressure Transducer with Rotatable Display

Inverted Through Board Surface

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

C910 Series. Single-point heat-tracing control system

U5600. Wireless Pressure Transducer SPECIFICATIONS

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

Manufacturing Notes for RFPA2189

MSP300 Pressure Transducer

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

U5300 Industrial Pressure Transducer

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

LOW PRESSURE Intrinsically Safe Transducer AST44LP

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

EET V-9 white PVC Labels

DTS SERIES CONNECTORS

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

Installation guide for J4 Junction Box for R4 AIS Transponder System

A world of fiber Product overview

PT9600. Cable Actuated Encoder Reel. General. Environmental

Cable Actuated Sensor Industrial Incremental Encoder Output

Manufacturing Notes for RFPA2016

Supervisor Standard Edition

RFFM6403. Manufacturing Notes. Table of Contents

QuickStat-TC Installation & Operation Manual

PlanarMag Product Technology

Transcription:

Telecom Fuses The FT600 fuse series is designed to assist telecommunications equipment manufacturers in complying with North American overcurrent protection requirements, including Telcordia GR- 1089, TIA-968-A (formerly FCC Part 68), and UL60950 3rd edition. The low profile and small footprint of the FT600 fuse provide a reliable, non-resettable overcurrent protection solution. The device offers low temperature-rise performance under sneak current fault events to prevent damage to circuit traces or multilayer boards. When used in conjunction with SiBar thyristor devices, it provides designers with a complete overcurrent/overvoltage protection solution to help them comply with regulatory standards. This fuse offering complements the telecom resettable PolySwitch device series for use in applications where intervention is desired after an overcurrent fault. Benefits High density placement in multi-port system designs Improved temperature rise performance over other similar SMT fuse devices under sneak-current testing The FT600 in conjunction with a SiBar overvoltage protection device, assists designers in meeting regulatory standards with no additional series components Features Low profile and small footprint The lightning robust surface-mount fuse offers overcurrent protection in case of power fault events Enables the design of equipment complying with applicable telecom specifications including UL60950, TIA-968-A (formerly FCC Part 68), and Telcordia GR-1089 Low resistance Applications ADSL, ADSL2, ADSL2plus, SHDSL, VDSL linecards and modems T1/E1 systems Twisted-pair telecom ports requiring Telcordia GR-1089, UL60950 and FCC Part TIA-968-A (formerly FCC Part 68) compliance 85

Protection Application Guide for Telecommunications and Networking Devices To use this guide, follow the steps below: 1. Select your equipment type from the guide below. 2. Use the Key Device Selection Criteria (time-to-open, surface temperature) to determine best suitability for your application. 3. Use Agency Specification / Selection Guide on the next page to select a specific part number for each application based on the agency requirements. Key Device Selection Citeria Faster Cooler Surface SiBar Thyristor Application Specification Time-To-Open Temperature Surge Protectors* Customer premises equipment, IT equipment UL 60950 FT600-0500 FT600-2000 TVBxxxSC-L Analog modems, V.90 modems, TIA-968-A FT600-50 ISDN modems, xdsl modems, ADSL splitters, phone sets, fax machines, answering machines, caller ID, internet appliances, PBX systems, POS terminals, wall plugs Access network equipment Telcordia GR-1089 FT600-50 FT600-2000 TVBxxxSC-L Remote terminals, line repeaters, multiplexers, TIA-968-A cross-connects, WAN equipment Central office switching equipment Telcordia GR-1089 FT600-50 FT600-2000 TVBxxxSC-L Analog/POTS linecards, ISDN linecards, xdsl modems, TIA-968-A ADSL/VDSL splitters, T1/E1 linecards, multiplexers, CSU/DSU, servers Notes: This list is not exhaustive. Raychem Circuit Protection welcomes our customers input for additional application ideas for overcurrent protection of telecom applications. * For more information on Raychem Circuit Protection SiBar thyristor surge protectors. Telecom Fuses Agency Specification/Selection Guide for FT600 Devices Use the guide below to select FT600 devices appropriate for use in your application. The following pages contain specifications for part numbers recommended below. FT600 devices enable telecommunication equipment to meet the applicable protection requirements of these industry specifications. Refer to individual agency specifications for test procedures and circuit schematics. Users should independently evaluate the suitability of, and test each product for their application. Family Product Lightning Power Cross FT600 FT600-0500 TIA-968-A (formerly FCC Part 68) - Type A & B UL60950, 3rd Ed. 600VAC, 40A FT600-50 Telcordia GR-1089 Level 1 and 2 Telcordia GR-1089 600 VAC, 40A FT600-2000 TIA-968-A UL60950 Note: FT600-50 and FT600-2000 are designed to assist equipment in complying with Telcordia GR-1089 specifications. In-circuit testing is strongly recommended. The FT600-0500, FT600-50 and FT600-2000 are designed to meet the UL60950 Power Cross and FCC TIA-968-A 68 lightning surge requirements. Note that Type A tests allow for an overcurrent protection component to fuse open during the surge. Interrupt Voltage and Current Ratings for FT600 Devices Part Ampere Rating Voltage Rating Typical Resistance Typical I 2 t Number (A) (V) (Ω) (A 2 S)* FT600-0500 0.50 250 0.5 1 FT600-50 1.25 250 0.1 16 FT600-2000 2.00 250 0.05 18 The FT600-xxxx devices are designed to carry % of rated current for 4 hours minimum and 250% of rated current for 1 second minimum, 0 seconds maximum. Resistance measured at 10% of rated current. *I 2 t is calculated at 10 ms or less. Figure FT1 - Thermal Derating Curve (Normalized) for FT600 Devices 130 0 % of Current Rating 110 90 80 70-70 -50-30 -10 10 30 50 70 90 110 130 Ambient Temperature C 86

Figure FT2 - Dimension Figures for FT600 Devices Figure FT2 - Product Dimensions A C B Table FT1 - Dimensions for FT600 Devices in Millimeters (Inches) Dimension A B C Part Number Min. Max. Min. Max. Min. Max. Figure FT600-0500 10.5 3.4 3.4 FT2 FT600-50 10.5 3.4 3.4 FT2 FT600-2000 10.5 3.4 3.4 FT2 Figure FT3 - Typical Time-to-open Characteristics (at 20 C) for FT600 Devices FT600 Figure FT3 A = FT600-0500 B = FT600-50.500A 1.25A 2A C = FT600-2000 10 A B C TIME IN SECONDS 1 0.1 0.01 0.001 0.1 1 10 0 CURRENT IN AMPERES 87

Table FT2 - Physical Characteristics and Environmental Specifications for FT600 Devices* FT600 Physical Characteristics Terminal material Silver-plated brass* Body material Ceramic Termination solderability Per IEC-607-4 *FT600 devices use high Pb content solder for internal construction. They are RoHS compliant. Telecom Fuses Environmental Specifications Test Conditions Solder heat withstand Per MIL-STD-202, Method 210, Test Condition J Solvent resistance Per MIL-STD-202F, Method 215J Storage temperature -40/+85 C Storage humidity Per MIL-STD-202F, Method 106F * FT600 devices use high Pb content solder for internal construction. They are RoHS compliant. Table FT3 - Packaging and Marking Information for FT600 Devices Part Number Bag Quantity Tape & Reel Quantity Standard Package Part Marking Agency Recognition FT600-0500-2 2,500 10,000 500 UL, CSA FT600-50-2 2,500 10,000 50 UL, CSA FT600-2000-2 2,500 10,000 2000 UL, CSA Notes: The -2 designates tape and reel, the package style for this product. Table FT4 - Recommended Pad Layouts for FT600 Devices in millimeters (inches) Nominal Device A B C D Figures for Dimensions FT600-0500.6 4.0 3.7 5.2 4 Figure FT4 D C FT600-50.6 4.0 3.7 5.2 4 B FT600-2000.6 4.0 3.7 5.2 4 A Solder Reflow and Rework Recommendations for FT600 Devices Solder Reflow: Recommended reflow methods: IR, vapor phase oven, hot air oven Devices can be cleaned using standard industry methods and solvents Figure FT5 300 250 Preheating Soldering Cooling Rework: If a device is removed from the board, it should be discarded and replaced by a new device Temperature ( C) 200 150 50 0 30 to 90 10 to 20 Time(s) 0 88

Part Numbering System for FT600 Devices FT 600-50 -2 Packaging -2 :Tape & reel Current in Amperes 50=1.25 0500=0.500 2000=2.00 Voltage Rating Product Family WARNING: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco Electronics Corporation makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Electronics only obligations are those in the Company s Standard Terms and Conditions of Sale for this product, and in no case will Tyco Electronics be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Electronics reserves the right to make changes without notification to Buyer to materials or processing that do not affect compliance with any applicable specification. 89