INSTRUCTIONS MANUAL SAUNA USER INTERFACE ENGLISH

Similar documents
CONTROLS INSTRUCTIONS MANUAL ENGLISH

CONTROLS INSTRUCTIONS MANUAL ENGLISH

Optional Optional. Min 20W, max 100W. Only resistive load or dimmable (phase control compatible) light bulb. Dimmer optional

INSTRUCTIONS MANUAL CONTROLS. Description Power Rating Remarks Steamer. Description Power Rating Remarks Control

STAINLESS STEEL TOUCH CONTROL

STEAM GENERATOR. Congratulations on your purchase of a SAWO Steam Generator. Please read the manual carefully before using the steam generator.

VK902 Compact Combination Microwave Oven Installation, Use and Maintenance

Oceanic Sauna Heater Manual

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Instruction Manual for Electric Ovens OO757X OO986X

20W and 45W Dimmable LED Power Supply INSTALLATION GUIDE. Copyright ASP Holdings, Inc.

Sauna & Steam BEHIND BENCH HEATER. Assembly and operating manual September 2018 PRODUCT IMAGE

Operating Manual. Series FCU5xxx. Sauna Sauna & Humidity Sauna, Humidity & IR Steam Bath FCU5000 FCU5200 FCU5400 FCU5000-STEAM. VDE in preparation

MENU. Steamist Xenio Sauna Control, Product: 0941 and 0942 Model: S170-1 and S Steamist Xenio Sauna Control. Contents

Installation, Operating and Servicing Instructions. Opus 800 Electric Cook & Hold Salamander OE8306

MENU. Steamist Digital Sauna Control Models: S170-1 and S Steamist Digital Sauna Control. Contents. 1. Steamist Digital Sauna Control

Table of contents. Installation instructions 3 4. Connecting the electric heater to electrical network 4. Control unit 4. Temperature restrictor 4

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

Assembly instructions and instructions for use for electric sauna oven with evaporator. Bi-O-Mat W MADE IN GERMANY IPX en / -44.

User instructions DHP-AT

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

ECON D3 Sauna control unit

MANUAL PX4 ENGLISH. Nimbus Combi NIMC-90N NIMC-105N NIMC-120N Super Nimbus Combi ELECTRIC SAUNA HEATER / STEAM GENERATOR

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

VK702 Compact Steam Oven with Grill Installation, Use and Maintenance

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Premier Hazard STC Instructions

Integrated PIR detectors

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Air Conditioner. user manual. imagine the possibilities. Wired Remote Control MWR-WH02. This manual is made with 100% recycled paper.

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

Sauna & Steam. SAUNA HEATER with OCSB/LB CONTROLLER Assembly and operating manual PRODUCT IMAGE

ACS-30-EU-VIA-DU-20-MOD

InfraTec Premium. Assembly and operating instruction. 20 min. Made in Germany. Druck Nr en/ :00 20 C

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

wc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

LED Compatible Daylight Harvesting and Motion Sensor System

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

Sauna control Series FCU2000/FCU2200 Series FCU3000/FCU3200/FCU3400 Series FCU4000/FCU4200/FCU4400 Series FCU5000/FCU5200/FCU5400

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

C106 Coded Access Keypad

IMPORTANT SAFETY INFORMATION

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

TERMO-Blok TERMO-Extra TERMO-Blok PTV

Engineers manual. Pass Through machines P500 P500 A P500 AS P500 A WS P500 AS WS. A- AirBreak WS Water Softener. AS Dual Rinse Element

DC740 Built-under & DC940 Built-In

Installation instructions. Built-in oven. and User guide NZ AU GB IE. OB60 single & double multifunction models

Installation, Operating and Servicing Instructions

The Classeq under counter range

CSH COMBINED STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE

Instruction Manual. OLSBERG High-line heater

OPERATING INSTRUCTIONS. Drying cabinet DC 7774 DC Read the instructions before using the machine.

WHYNTER PORTABLE ICE MAKER 49 LB CAPACITY - STAINLESS STEEL

DOL 31 Speed Controller Technical User Guide

Sauna control Series FCU2000/FCU2200 Series FCU3000/FCU3200/FCU3400 Series FCU4000/FCU4200/FCU4400

OPERATING INSTRUCTIONS

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

installation guide installation guide electronic intelligent timer thermostat

Roth Touchline. German quality since Quick and easy user manual 1/10

UBGHFF60W 60cm Gas on Glass Gas Hob

MC 31 Speed Controller Technical User Guide Code no GB

SAT-3 Room Temperature Controller

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

Installation and user manual

Marco Beverage Systems Ltd.

Installation, Operating and Servicing Instructions

SENSA MRE DDM MR

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Island Hood KCH110ST/KCH900IS. User and Installation Instruction

Operating and maintenance instructions for hobs

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

Instructions for installation and use

Ultrasonic Digital Humidifier

INFRARED PANEL HEATER

CR9934 ROBERTS. PLL Dual Alarm Clock Radio. Sound for Generations. Please read this manual before use

Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODELS

LEVENS STEAM SHOWER ENCLOSURE

Sensor Control Panel

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Rigoletto 60,90 & 120 Built-In Cupboard Hood

BTU Units WORKING PROGRAM MANUAL

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

Transcription:

INSTRUCTIONS MANUAL SAUNA USER INTERFACE ENGLISH

1.0 1.1 2.0 2.1 2.2 2.3 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13 TABLE OF CONTENTS Introduction of Saunova Control Precautions Unit Description General Direction of Use Standard Accessories Directions of Use Buttons and States Changing Language Turning ON the Heater Turning OFF the Heater Electronic Hour Glass Setting Temperature Cabin Light Programming 3.8.1 3.8.2 3.8.3 3.8.4 Pre-Run Timer Session Time Temperature Correction Factor Programming of the Acoustic Signal Electrical Diagram Safety Switch-Off Eco Code Automatic Switching of the Display Version Display 1 1 2 2 2 2 3 3 3 4 4 5 5 6 6 6 7 7 8 9-10 11 11 11 12

4.0 4.1 4.2 4.3 4.4 4.5 5.0 5.1 5.2 6.0 6.1 6.2 Assembly and Installation Installation of the Power Controller Installing Power Controller Inside Sauna Room Sensor Location for Wall Mounted Heaters Sensor Location with Heaters Mounted on the Wall Installation of the User Interface Electrical Connections Error Displays Symbol Reference Technical Data Power Controller Technical Data User Interface 13 13 14 15 16 17 18 19 19 20 20 21

1.0 INTRODUCTION OF THE SAUNOVA CONTROL Congratulations on your purchase of Saunova Control Unit! Saunova Control Unit is developed to enhance your sauna bathing with a variety of features. It can adjust temperature and light option in your sauna. The following information provides you with instructions on adjusting the settings of the control unit. Please, read this instruction manual carefully before using the control unit. Familiarization of the key functions will give you a more enjoyable sauna experience. 1.1 Precautions 1. 2. Only a qualified electrician is allowed to make the electrical connections and repairs on the unit. Use original parts only. Disconnect the Power Controller and the Contactor Unit from the electrical circuit before installation, repair or opening the lid of the power controller. 3. Check power supply rating before installation. 4. 5. 6. Check the correct location of the sensor in the installation section of the manual. It is very important to place the temperature sensor correctly as its closeness to air ventilation cools down the sensor and may lead to overheating. The control unit can be operated inside or outside of sauna room. Check the ambient requirements and limitations from technical data. Do not pour water in the control unit or clean it with wet cloth. For cleaning purposes, use a cleaning cloth that has been only slightly moistened with a mild soapy solvent (dish detergent). 1

2.0 UNIT DESCRIPTION 2.1 GENERAL The control unit consists of power controller and user interface. Control unit is designed to operate max 9 kw sauna heater and 100 W cabin light. Power Controller User Interface WARNING The instructions of the manual must be followed when wiring of the components is executed. 2.2 DIRECTION OF USE The control unit is ready for operation when all installations have been completed. If the user interface is connected to the system, a self-test starts running, and all LEDs start lighting up. Afterwards, the user interface changes in the stand-by mode and the ON/OFF ( LED lights up. ) State 2.3 STANDARD ACCESSORIES Scope of supply: Power Controller User interface Temperature sensor with thermal safety release 139 C Data cable and sensor cable 2

3.0. DIRECTIONS OF USE 3.1 BUTTONS AND STATES The control panel consists of: LED indicators LED display Power Mode / toggle Temperature Increase/ Decrease Electronic hourglass Cabin Light Power ON/OFF - Confirm OK 3.2 CHANGING LANGUAGE Saunova has the following languages available: English, German, Italian, Dutch, French. To change the language make sure the control is in OFF mode. When in OFF mode, long press the and buttons. This takes you to switch off menu. Change to the language menu by pressing and change language with and buttons. Confirm your selection by pressing the button. 3

3.3 TURNING ON THE HEATER Make sure that the rocker switch in the power controller is in ON(I) position. When the power controller is turned ON, the LED is lit up. By pressing the button you can turn on the user interface. After pressing the button, you can activate heater by pressing button again while LEDs displays the text If you want to turn OFF the user interface, you can navigate by pressing the button so that the display states and confirming by pressing the button. WARNING Always check that there are no combustible materials, like towels, above the heater, nor inside the safety distances, before switching the heater on! The safety distances are stated in the heater manual. 3.4 TURNING OFF THE HEATER You can finish the on going sauna session before the max session time runs out by pressing the button. After pressing, the text appears in the display. Confirm turning off the heater by pressing again. If max session time runs out, the heater will turn off automatically. 4

3.5 ELECTRONIC HOUR GLASS Electronic hour glass is a feature which allows you to set a timer that will alarm you after a certain time interwall has elapsed. The buzzer can be switched off if wanted(see instructions on page 10) After the heater has been turned on by pressing the button, navigate by using the button until the symbol is lighten up. When the symbol is lighten up, you can use the and buttons to increase and decrease the interwall time. After you have set the desired interwall time, you can navigate back to displaying the actual temperature by using the button. If no buttons are pressed, the screen returns back to displaying the current temperature. The unit of interwall time displayed is minutes. 3.6 SETTING TEMPERATURE After the heater has been turned on by pressing the button, navigate by using the button until the symbol is lighten up. When the symbol is lighten up, you can use the and buttons to increase and decrease the temperature. After you have set the desired temperature, the screen returns back to displaying the actual temperature after if no buttons are pressed in 3 seconds. 5

3.7 CABIN LIGHT After the heater has been turned on by pressing the button, navigate by using the button until the symbol is lighten up. When the symbol is lighten up, you can use the and buttons to increase and decrease the brightness of the cabin light. Short pressing the buttons will turn the light ON/OFF and long pressing allows you to dim the light. After you have set the desired brightness level, you can navigate back to displaying the actual temperature or remaining session time by using the button. If no buttons are pressed, the screen returns back to displaying the current temperature. 3.8 PROGRAMMING 3.8.1 PRE-RUN TIMER Pre-run timer is already activated when the and symbols are illuminated. The user interface displays you the time remaining in hours before the sauna heater will turn on automatically. If there is a blackout during pre-run, the pre-run is automatically cancelled. WARNING Always check that there are no combustible materials inside the safety distances, before using pre-run timer! WARNING The pre-run time is limited to a maximum of 6 hours for domestic saunas according to *) IEC 60335-2-53 When heater is OFF, you can activate the pre-run timer by pressing and buttons for 3 seconds. After that you can set the heater to turn ON automatically between 1 and 24 hours by using and buttons. After the desired pre-run time has been set, confirm the settings by pressing twice. If the symbols ON/OFF, and are light up, the pre-run is activated. The digital display shows the hours remaining before switch-on. The hour display only changes after every full hour. If you want to disable the pre-run timer, you can turn on the heater by pressing the button twice. If you want to disable the pre-run timer and turn off the heater press so that the display states and confirm turning off the control by pressing button. Maximum length for pre-run time is set to 4 hours as factory default. 6

3.8.2 SESSION TIME Automatic switch off feature is the maximum session time defined by the user after which the sauna heater turns off automatically. The switch off time can be set between 1 to 12 hours. Factory default setting is 4 hours. When in OFF mode long press the and buttons. Here you can choose the automatic swtich off time between 1 and 12 hours. Choose the desired time by pressing the and buttons and confirm your selection with button. 3.8.3 TEMPERATURE CORRECTION FACTOR Since the temperature is measured at the ceiling above the heater, the displayed temperature differs from the temperature in the bench area. This difference can be adjusted by entering a correction value between -9 and +9 for 100 C(+/- 9%). A value of 9, for example, means that if the measured temperature equals 100 C, the temperature displayed is 109 C; a value of -5 C means that if the measured temperature is 100 C, the displayed temperature is 95 C. Due to safety reasons, the maximum target temperature with a correction value of less than 0 will be reduced by this value, since the maximum reachable temperature is 110 C. 7 In ON mode, activate the symbol and press and buttons for 3 seconds, and then long press and buttons. In this menu you are able to choose the desired correction factor. Confirm your selection by pressing the button.

3.8.4 PROGRAMMING OF THE ACOUSTIC SIGNAL The acoustic signal (beeper) can be switched on and off in the following way. Switch with the button to the symbol. Press both buttons at the same time for 3 seconds. The number of the actual mode appears on the display. Change to desired operation mode with and buttons and confirm changes with or button. Value Mode 0 Quiet 1 Hourglass (= Standard) 2(not all heater models) Water shortage 3(not all heater models) Hourglass + water shortage 4(Not all control models) Remote control 5(Not all control models) Remote control + hourglass Function No acoustic signal Hourglass after expiration of 1 sec. active Continuous tone at water shortage Both signals active 3.8.5 PROGRAMMING OF THE ACOUSTIC SIGNAL When you select operating modes 4 or 5, you can make additional settings. Here you can specify if the control unit should stay ON or turn OFF after the remote control voltage has stopped: Switch ON Switch OFF Select = ON in the display Select = OFF in the display Confirm your selection with or button. 8

3.9 ELECTRICAL DIAGRAM Control Unit Main Switch MAX. 9.0KW 400 V 3N~ Attention Do not insert the RJ10 cable into the 6 pole jack. It could damage the plug. RJ 10 RJ 12 TS FUSE Res. U V W L1 L2 L3 Lamp N N N N PE PE PE PE RJ 11 - Data Cable 4 meters USER INTERFACE BLACK BROWN WHITE BLUE 5x2.5mm² U V W N 5x2.5mm² Lamp N PE 3x0.75mm² WARNING Use only sensor that has saunova text and is intended to saunova! FUS SAU NOVA TS Temperature Sensor with Fuse Sauna Heater MAX 9KW its equivalent. 9 5 core cable 10 FUSE 16A (R) L1 (S) L2 (T) L3 N PE Power Supply The cable must be HO7RN-F type or MAX 100W (Resistive Load)

3.10 SAFETY SWITCH-OFF The electronic control unit is equipped with a safety switch-off through a safety temperature limiter. If the sauna heater should not turn off, for any reason, the safety temperature limiter disconnects automatically the circuit at 139 C and turns off the heater. The safety temperature limiter needs to be replaced and an expert needs to be consulted if this scenario takes place. 3.11 ECO MODE Eco mode will help you to save energy if you want to take a break from sauna bathing. With this feature you can choose to have 20, 40, or 60 minute break. Eco feature lowers down the temperature during the break and heats it back to the target temperature after the chosen break time is over. While in Eco Mode, OFF light indicator blinks. Navigate to the symbol while in ON mode and long press the and buttons. Select the desired length for the break by pressing and buttons. Confirm your selection with button. 11

3.12 AUTOMATIC SWITCHING OF THE DISPLAY The display can be programmed to switch the displayed value automatically. The display switches between temperature and time. By using the button, switch to the symbol. Press the and buttons at the same time for 3 seconds. On the display appears either ON or OFF. Switch on by using button or switch off by using button. Confirm by using button. NOTE: The electronic hour glass value must be set to 1 or more in order to switch displaying values. You can select if the sauna lamp and the colour LED (not available in all models) should light up at the same time with the sauna light. By choosing ALL, both lights will turn on at the same time. By Choosing LED, only the LED lights will turn on. The colour relay module can always be turned on regardless if the sauna lamp is turned on or off. Confirm with or button. 3.13 VERSION DISPLAY By pressing the buttons, and at the same time in the OFF mode, the software version number of the power controller will be displayed (i.e. 14 ). If you press the button during this time again, the software number of the control panel will be displayed together with a letter P, in order to separate it from the power controllers version number(i.e. P14 ). After few seconds, the display turns back to the OFF mode. 12

4.0 ASSEMBLY AND INSTALLATION NOTE: Saunova control unit can be installed inside or outside the sauna room. ATTENTION! Install the components only with a screwdriver and not with a portable electric drill! Fig.2 INSIDE THE SAUNA ROOM OUTSIDE THE SAUNA ROOM SENSOR min. 1000mm min. 1000mm USER INTERFACE USER INTERFACE WALL HEATER RJ 10 - Data Cable POWER CONTROLLER POWER CONTROLLER RJ 10 - Data Cable max 1300 mm from the floor FLOOR max 200 mm from the floor POWER SUPPLY 4.1 INSTALLATION OF THE POWER CONTROLLER The installation location of control unit must follow the allowed ambient limits. Don t install the power controller in a recess or less than 300mm from the ceiling (Refer to Fig. 3). If installed inside sauna room, always use additional SAWO splash cover and install the power controller close to floor level where the temperature is naturally cooler. The heater is connected to the electrical network semi-stationarily with a H07RN-F rubber cable or its equivalent. The use of PVC-insulated cable as a connecting cable is prohibited due to thermal embrittlement. Fig.3 Fig.4 CEILING LEVEL MIN. 300 mm WARNING Do not embed the control unit into the wall, because it may lead to overheating of the unit and cause damage! *Install the Power Controller in vertical direction only. 13

4.2 INSTALLING POWER CONTROLLER INSIDE SAUNA ROOM If the power controller is installed inside sauna room, the ambient requirements must be followed (page 13). In addition to ambient requirements, the location must be in a place where there is no risk of water splash hitting the power controller. An additional splash cover (not included to the package) must be used to protect power controller. Preferred location to install the power controller together with the splash cover is underneath the benches close to the floor level where the temperature is naturally lower than in the upper portions of the sauna. If installed inside sauna room, the power controller must be installed 200mm from the floor measured from the lower portion of the power controller and at least 1000mm from the heater. After installation, seal all the lead through holes with for example silicone. WARNING Make sure that the ambient temperature won t exceed the allowed limit, and that the power controller is protected from water splashes. Fig.5 1. Unscrew 3. Screw the splash cover to the wall through the hole located in the back of the power controller casing. 9mm 2. Unscrew and remove board. Push to open. Attach and screw the plastic backing to the wall together with the splash cover. 4. Flip to cover. Attach the board back to the plastic backing. 14

4.3 SENSOR LOCATION FOR WALL MOUNTED HEATERS The power controller is equipped with a temperature sensor that works also as a safety release sensor at the same time. If the heater is mounted on the wall or floor standing less than 200mm from the wall, the temperature sensor needs to be mounted on the wall above the heater. Place the sensor 150mm from the ceiling (Fig. 6 & 7). Do not place the sensors near the air ventilation. The closeness of the air vent cools down the sensor. Thus, an incorrect temperature is displayed and the heater may overheat (Fig.9). Sensor location with heaters mounted on the wall or less than 200 mm from the wall. TEMPERATURE SENSOR WITH FUSE ON THE WALL Fig.6 A I R V E N T Min. 1300mm Min. 300mm Min. 1000mm WALL Fig.7 150mm CEILING 150mm WARNING Always install the sensor in same orientation as illustrated in the manual FLOOR NOTE Do not place the sensors too near to air ventilation. Not under 1000mm from a non directed ventilation or not under 500mm from air ventilation, which is directed away from sensors. 15

Min. 1300mm Min. 300mm 4.4 SENSOR LOCATION FOR HEATERS MOUNTED MORE THAN 200 MM FROM THE WALL If the heater is floor standing model, and more than 200mm from the wall, place the sensor to the ceiling over the heater, as shown in the figure 8 & 9. If the heater is less than 200mm from the wall, use the same sensor location that is intended for wall mounted heaters on page17. Fig.9 Fig.8 A I R V E N T Min. 1000mm Attached to Ceiling WALL Top view POSSIBLE SENSOR LOCATIONS Sensor A I R V E N T Side view Min. 1000mm CEILING FLOOR min 200mm from the wall 4.5 MAXIMUM SESSION TIME The maximum sauna session time depends on the purpose of the sauna. For domestic use, the total on-time of the sauna is limited to 4 hours. It includes pre-run time and the session time. The factory setting for the control unit is 4 hours. For condominiums, hotels and similar locations, the operating period of the sauna heater is limited to 12 hours, including the pre-run time and the session time. The heater must have a minimum 6 hours of inactivity between sessions (IEC 60335-2-53). The standards and regulations of the country where the control unit is installed must be followed. Change the maximum session time by following the instructions in page 7. 16

4.6 INSTALLATION OF THE USER INTERFACE - Mount the separate control panel casing in preferred location. - Cut the wall section according to the specifications. - Cut tapered edges to the hole for the user interface to be flushed nicely to the wall. - Connect the RJ10 cable from the control panel to the Power Controller. - Insert the casing on the cut section and screw the Control panel to the wall tightly. Fig.10 Ø70mm 45mm Casing Top cover Power Controller Installation of User Interface and Power Controller User Interface Power Controller Unscrew Unscrew Push to open. Saunova user interface can be installed inside or outside the sauna room. Always make sure that the allowed ambient circumstances are not violated (see page 21). (RJ10 communication cable can not withstand high temperatures and must be installed inside the wall insulation). It is recommended to install the user interface to max 1300mm from the floor level. Fig.8 A B RJ10 Cable C 70mm RJ10 Cable 17

THE CONTROL UNIT MAIN SWITCH The control unit switch can be found on the top end of the unit.by using this switch, you can isolate the electronics from the mains power supply. In order to activate the unit, switch to the ON position (switch position I). In this position all control unit s functions work normally. II 0 I In case of breakdown, press the switch to the OFF position (switch position 0). The unit is now completely switched off. I = UNIT ON 0 = OFF In order to switch on the sauna light when the unit is switched off, press the switch to the LIGHT ON position (switch position II). II = LIGHT ON 5.0 ELECTRICAL CONNECTIONS NOTE: Disconnect all poles until all work has been completed and fuse prior to re-connecting! The connection of the sauna control unit must be completed by a licensed specialist (electrician) in accordance with the relevant standards. The cable used must comply with the relevant statutory provisions. NOTE: According to standard EN60335, light and oven have to have a separate power supply. Since the sauna control unit is powered via the light supply, it is crucial that the light supply is connected! WARNING Please note, only a qualified electricial or maitenance personnel should make the service operations or repairs. 18

5.1 ERROR DISPLAYS The control unit is equipped with diagnosis software. When control unit is turned on, a self-test will be retrieved and various conditions will be checked during the normal use. If error was found, the control unit turns off, all user symbols start blinking and an error number appears on the display. The following table gives information about the cause. Error number Description -5 No control unit is connected. -10 No control unit is connected, after at least one was recognized at the high start. -21 Heater temperature sensor broken. -22 Heater temperature sensor short circuit. -24 Bench temperature sensor broken. -25 Bench temperature sensor short circuit. -26 Humidity sensor broken. -27 Humidity sensor short circuit. -30 Faulty thermal safety release. 5.2 SYMBOL REFERENCE Repair/C ause No control unit is connected or bad connection. Check connection to the control unit. Damaged temperature sensor or bad connection. Damaged temperature sensor or bad connection. Damaged temperature sensor or bad connection. Damaged temperature sensor or bad connection. Damaged humidity sensor or bad connection. Damaged humidity sensor or bad connection. Faulty heater sensor or bad connection. Contact service personnel! Indicators ON State Temperature Timer Cabin Light Buttons Mode Increase Decrease 19 Confirm/OK

6.0 TECHNICAL DATA 6.1 POWER CONTROLLER System connection Connection internal display Control voltage System cable Light connection Heater connection Thermal safety release Temperature sensor Power input Ambient conditions Housing Dimensions: L x W x H Weight For 3 x 400 V ~ 50 Hz with L1-L2-L3-N-PE; 1 x 230 V ~ 50 Hz with L-N-PE; Housing only for standardised service connection with fusing and residual current circuit breaker (RCCB). The mains switch must have a minimum contact gap of 3 mm! 4-pole with 5 V = supply and communication; length = 3 m Extra low voltage 5 V Typically 5 x 2.5 mm² for heater (cross section refer to 6.1.0) Typically 3 x 1,5 mm² for light + electronic With integrated phase dimmer, for 2 (3) pole connection of the 230 V incandescent lamp(s); max. 100 W 3 x 400 V ~ 5-pole, up to max. 3 kw depending on the heater output, and/or 14 A / phase Integrated into the temperature sensor as over heating protection; release temperature 139 C 2-pole; semi conductor sensor 9 C to 140 C Mode FIN: max. 3 x 3 kw (heater) Mode FEU: max. 2 x 3 kw (heater) and max. 1 x 3 kw (evaporator) For light: max. 100 W 0 C to max. 50 C, max. 95 % reel. Humidity, not condensation! 265 x 245 x 80 mm ~ 1400 g without packaging 20

6.2 TECHNICAL DATA USER INTERFACE Connection Power input Temperature setting Time interval/el. Hourglass Light dimmer Ambient conditions Dimensions: L x W x H Weight 4-pole with supply and communications line 5 V= / < 100 ma normal mode (< 0. 5 W) Display of current temperature and desired temperature 30 C 110 C (+/- 1 C) depending on the programme 0-99 min with disengageable beeper 0 % - 100 % (+/-2 %) for up to 100 W 0 C - 80 C, max. 99 % rel. Humidity, no condensation allowed! 110 x 95 x 50 mm ~ 212g without cable and without packaging Note! Only incandescent light bulbs are allowed to use with Saunova sauna controller. Light fixtures using electronic transformers, for example LED lights, compact fluorescent lights and other similar lights are not compatible with Saunova sauna controller. Damages caused by connecting these non-compatible lights are not covered by warranty. www.sawo.com info@sawo.com Subject to change without notice. SAU_ML(En00517)