ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

Similar documents
ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

ice 3000 Series Atomic Absorption Spectrometers

PG 990 Atomic Absorption

AAnalyst 700 Atomic Absorption Spectrometer

AAnalyst 600/800 atomic absorption spectrometers

Affordable Lab Technology

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

M&S Series Atomic Absorption Systems

detectors UltiMate 3000 Variable Wavelength Detectors

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

ATOMIC ABSORPTION SPECTROMETER AAS 3500 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

PSA Series. Particle Size Analyzer

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

get mass. without massive work. [ 3100 MASS DETECTOR ]

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

SP-3800AA Atomic Absorption Spectrophotometer

Model S FT-IR SPECTROMETER

Inspection Machines Ampoules, Vials, Cartridges, LVP, Pre-filled Syringes. When Inspection Needs Perfection

Kronos Class B Sterilizer

Atomic Absorption Spectrometer

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

Thermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific

Thermo Scientific Heratherm Heating and Drying Ovens. Efficient, safe and easy

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

Mercury Vapor Monitor VM-3000

VM-3000 Mercury Vapor Monitor

HFID Heated Total Hydrocarbon Analyzer Module

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

ENVAIR lab CO2 Tri-Gas Incubator

Nicolet Evolution 300. UV-Visible Spectrophotometer

The Viva-ProE System

VM-3000 Mercury Vapor Monitor

Reacti-Therm I and III Heating Modules

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Thermo Scientific Heratherm Heating and Drying Ovens

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

CEIA THS/PH21. series HIGH PERFORMANCE PHARMACEUTICAL METAL DETECTION SYSTEMS. Superior and Consistent Detection Enhanced Product Throughput Rate

AMSCO Washer/ Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare.

A Platform for the Future ULTIMA 2 ICP OPTICAL E MISSION S PECTROMETER

For over 30 years, our focus has been to protect animal health and research in Pharmaceutical, Government and University animal research facilities.

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

AGILENT VS SERIES LEAK DETECTORS

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

IC Professional Detector

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

t. +44 (0) f. +44 (0) e. w.

CEIA THS/PH21. series. High Performance Pharmaceutical Metal Detection Systems. Superior and Consistent Detection

Introduction to Docking Technology

Atomic Absorption Spectrophotometers. AA Series C122-E058E

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Altanium Temperature Controllers

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Customised HPLC Systems for Highest Performance

L CONNECTION NETWORK Commercial Controls

SPM Flex Chemcassette Tape-Based Gas Detector

Modular Circular Polarimeters

for Drinking Water Systems

REAL TIME LABORATORY MONITORING SYSTEM

ELISA NIMBUS. Automated ELISA Processing System

Neotronics portable gas detection. Portable protection from hazardous gas

Application of a Reagentless Direct Conductivity Online TOC Analyzer for Clean-in-Place Verification

C122-E058C. AA-7000 Series. Shimadzu Atomic Absorption Spectrophotometers

Orion ionplus 2111LL low-level sodium monitor. The next generation in sodium protection. Analyze Detect Measure Control

Best Freeze Drying Solutions

Autodesk Moldflow Insight AMI Molding Window Analysis

PHARMACEUTICAL INDUSTRY CLEANING SYSTEMS

LSM Quadrant Source and Measure Unit for LED Production Tests. Two Global Leaders. One Complete Solution.

Thermo Scientific Heratherm Microbiological Incubators

Modular Circular Polarimeters

PG 8535 Perfect Reprocessing

Spectrum IR Series Mid-, Near- and Far-Infrared Spectroscopy THE WINNING PLATFORM

Lighting Measurement Solutions

Series 9000 Total Hydrocarbon Analyzer

Contamination Control for Life Science Applications

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

HydroFlex FLEXIBLE AND RELIABLE MICROPLATE STRIP WASHING AND VACUUM FILTRATION IN A COMPACT, MODULAR PLATFORM. 21 CFR Part 11* 98/79/EC IVD-D*

/ / White Paper. Focusing on user experience

An FT-NIR Primer. NR800-A-006

Reacti-Therm I and III Heating/Stirring Modules

Dew-Point Transmitters and Instruments

0&-&!5--~00a 4. AGENDA: 5. REQUIREMENT/PURPOSE: 6. REQUESTOR OF INFORMATION: (Smcifi) CONSENT

Common Customer Challenges

LÖDIGE ALWAYS THE RIGHT MIX

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

ELD500 PRECISION LEAK DETECTOR

SENTRY-MS Mono-static Multi-gas Open Path Analyzer

Make critical-care decisions with fast, accurate results.

COURSE 474 CONTINUOUS EMISSION MONITORING Extended Agenda

CS744 Series: Carbon/Sulfur by Combustion

Efficient, safe and easy

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

Transcription:

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

ice 3000 Series AAS Simple, automated, single element analysis by flame or graphite furnace AAS from ppb to % The Thermo Scientific ice 3000 Series AAS enables simple measurement of elements in a wide range of samples. The flame atomizer is ideal for the measurement of high concentration samples, whilst the furnace atomizer achieves sub ppb detection. The dual atomizer system with Stockdale optics incorporates advanced background correction with a unique quadline deuterium source and optional Zeeman correction to ensure accurate analysis. Easy-access lamp carousel (with quick-fit lamps) speeds up everyday tasks Automated optimization wizards enable experienced and novice users to achieve optimal performance Flame analysis The ice 3000 Series AAS flame instruments provide ideal analysis solutions for laboratories requiring wide detection capability for over 60 elements and enable rapid, robust and reliable analysis. Furnace analysis The dedicated furnace atomizers of the ice 3000 Series AAS allow for unattended analysis of low concentration samples. The analysis is simplified by a wizard driven workflow which guides the user through the process of method development, ensuring optimal parameters for a specific analysis. Integrated Graphite Furnace Television (GFTV) enables vital information to be gathered on sample injection and allows optimization Configure how standards, samples and modifiers are used and located in the autosampler to suit your workflow Automatic optical control of the cuvette heating ensures repeatable heating, eliminating drift Extended life and platform cuvettes ensure maximum cuvette life-time for your sample type Self-calibrating monochromator and auto-aligning lamps ensure optimum light throughput for maximum sensitivity Robust burner offers extended analysis when analyzing challenging samples Fully automatic gas control ensures repeatable flame conditions and safety Flame optimization routines incorporated into daily analysis ensure parameters are optimal 2 Thermo Scientific ice 3500 AAS. 3

Laboratory optimization Simplify your AAS analysis without compromising performance The ice 3000 Series AAS enhances analytical performance and automation through the use of advanced accessories controlled by Thermo Scientific SOLAAR Software. The accessories enable the most challenging samples to be analyzed, whilst meeting the demands of a high-performance laboratory. Flame auto-sampler Supporting a range of auto-samplers, the ice 3000 Series AAS enables operators to achieve demanding volume workloads through automation. The autosamplers can also be used in combination with a range of additional accessories. Flame dilution ID100 This offers speed and accuracy by automatically preparing standards from a master stock solution. High-speed intelligent dilution ensures out-of-range samples are diluted into the calibration range. Intelligent spectrometer qualification (isq) A calibrated module is used to test various instrument performance criteria and provides a simple, convenient pass and fail report. Thermo Scientific ice SOLAAR software The intuitive, easy-to-use ice SOLAAR AAS Software has extensive wizards to guide you through various operational procedures, making start-up exceptionally quick and simple. The help text and cookbook provide additional information about the operational conditions for any elemental analysis. Application tips for sample preparation, matrix modifiers and many other important factors are available in the software. This support combines to give you confidence in performing successful analyses, no matter how difficult your samples seem. Thermo Scientific SOLAAR security SOLAAR Security secures data for compliance purposes and good practice. It provides all the tools required to comply with the FDA 21 CFR part 11 ruling by adding e-signatures, event logs, audit trails and access controls. There are many wizards available to walk you through various operations to achieve complete instrument and method set up. They get you productive fast by: Providing step-by-step guides to routine activities Allowing more advanced facilities to be explored as experience grows Demonstrating the correct sequence of operations to achieve a specific objective Vapor generation VP100 Software-controlled, this system is a simple and cost-effective solution for reaching lower detection limits in the Arsenic group elements. Validator packages Offering a comprehensive log book with pre-printed forms, detailed SOPs and integrated software, these packages provide all you need from specification design and installation qualification, to operational and performance qualification. 4 5

Sample analysis Instruments and accessories to perform analysis of a wide range of sample types Environmental analysis The powerful detection capabilities of the ice 3000 Series AAS graphite furnace and hydride generation systems are ideal for the targeted monitoring of trace elements in a range of environmental samples. This applies either in response to a specific environmental event or as a part of routine monitoring. The wizard-driven software simplifies method development for new analytes. Pharmaceutical and nutraceutical compliance Ensure you have a qualified instrument to comply with current and future legislation, including the new General Chapters and one Supplemental General Chapter of the United States Pharmacopeia: <232> Elemental Impurities Limits <233> Elemental Impurities Procedures Food safety You can measure key elements for food labeling applications using the flame atomizer and monitor toxic elements using the graphite furnace or hydride generation system for enhanced sensitivity. This combination allows concentration ranges from sub ppb to % to be accurately measured for compliance with international food safety and labeling standards. You can also use the intelligent spectrometer qualification tool to optimize the instrument s daily performance prior to analysis. 6 <2232> Elemental contaminants in dietary supplements SOLAAR Security Software allows for full traceability of the results, with features to support compliance of CFR 21 Part 11 such as electronic signature and audit trail. Dedicated validation and qualification packages ensure fast installation and qualification of the instrument in your laboratory. Industrial QA/QC With a wide measurement range, the ice 3000 Series AAS is well suited to a quality control environment. It has the ability to measure major elements in products as well as key contaminants that may pose a risk to product quality. The simplified wizard-driven software is suited to a production environment too, guiding users of any skill level through the analytical procedure from sample to result. 7

ice 3000 Series AAS Uncomplicated flame and furnace AAS analysis for routine laboratories ice 3300 AAS A simple, versatility single atomizer AAS with fully automatic gas box. A Complete solution for laboratories with a main need to perform flame analysis but with occasional furnace samples. ice 3400 AAS Achieve challenging detection limits with a single graphite furnace atomizer and interference removal with Zeeman and D 2 background correction. ice 3500 AAS A unique dual atomizer AAS with standard or Zeeman furnace option. Essential furnace vision tool for simple instrument optimsation. Ideal for high through put environments. Find out more at thermofisher.com/aas For Research Use Only. Not for use in diagnostic procedures. 2018 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. BR44364-EN 0918