Instruction Manual. Pharma-line ESE02198-EN Original manual

Similar documents
Instruction Manual. Pharma-X ESE02197-EN Original manual

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

4 route 147, C.P.33 Coaticook, Qc J1A 2S8

ALLEGHENY BRADFORD CORPORATION

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

Instruction Manual, Toftejorg Rotary Spray Heads Toftejorg MultiMidget, Toftejorg MultiMagnum

BoilerSupplies.Com. America's Choice For Boiler Room Supplies. Installation, Operation, & Maintenance Instructions For Shell & Tube Heat Exchangers

Titanium Plate Heat Exchanger. Installation & Operating Manual

OPERATION & MAINTENANACE MANUAL

Installation, Operation and Maintenance Manual for B&G U Series Heat Exchangers Removable Bundle Design BELL & GOSSETT.

WFIS. Water For Injection Stills

Instruction Manual, Rotary Spray Heads

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

INFINITY FLUIDS CORPORATION

Instruction Manual Plate Condenser. AlfaCond 400/600/800. Part number

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

LONGONI ENGINEERING SRL

Instruction Manual - Plate Heat Exchangers

Installation of Glass Lined Equipment

M3 M6 M10 TS6 T2 T5 TL3 TL6

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

providing the perfect mix

Instruction manual. Alfa Laval Rotacheck+ & Rotacheck Basic. Machines delivered with ATEX Certification in accordance with Directive 94/9/EC

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

Alfa Laval Potentiometric Level Transmitter

Heat Transfer. the new standard in. Heat Exchangers. Storage, Installation, Operation and Maintenance

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015

Heat exchangers for hygienic use. The complete line

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

Inverted Bucket Steam Traps

Instruction Manual. Alfa Laval Agitator - ALT / ALTB ESE03504-EN Original manual

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

COPYRIGHT Alfa Laval Lund AB, 2012 How to contact Alfa Laval Contact details for all countries are continually updated on our website.

Standard Parts in Hygienic Design

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

GMP compliant cleaning in the Pharmaceutical Industry. Andreas Trochsler 06. November 2012

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

BAGI - MIXER. Magnetically Driven Bottom Mounted Mixers. Sealless ZERO LEAKAGE Design. CIP / SIP Capable. Non Contaminating Mixing

CRU-S Series Stainless Steel Condensate Recovery Unit

Covering: Standard Machines Machines delivered with ATEX Certification in accordance with Directive 2014/34/EU TE91A664 First published:

5.07 Air Replenishment Systems

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

13-1. Temperature Regulator

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e

Alfa Laval Level Switch

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

TITAN FLOW CONTROL, INC.

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

STEAM - WATER MIXERS ADCAMIX MX20

Friwa Compact. Operating instructions EN

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Blowdown Separator & Aftercoolers

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

A. This Section includes the following domestic water piping specialties:

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

INSTALLATION INSTRUCTIONS FOR. 230/240 VAC, 1ø, 50Hz SERIES RV ROOF TOP AIR CONDITIONER/HEAT PUMP

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

BOILER HOUSE PRODUCTS GMS

Rycroft Supapac Plate Heat Exchangers

VERSAFLOW VORTEX Supplementary instructions

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

Niles Steel Tank Hot Water Generator Installation and Operation Manual

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Alfa Laval spiral heat exchangers

Reflex Longtherm. Soldered plate-type heat exchanger. Operating instructions

GASEOUS HYDROGEN SYSTEMS

DESCRIPTION OF GAGE ASSEMBLY

SAFETY AND OPERATING MANUAL

S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design.

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Installation and operating instructions. DK energy storage and DK energy buffer

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

InterSeptor Centrifugal Separators Operating & Maintenance Manual

OPERATING AND MAINTENANCE MANUAL FOR VERTICAL IMMERSION HEATED STEAM BOILERS. Technical Control Systems Limited MODELS "VIHS"

Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

AXPR Wall Mounted Axial Panel Fans

Brazed heat exchangers

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

Description. Main components. Lifting eyes To used for lifting and transport securing. Carrying bar Carries the cassettes and the pressure plate.

OIL SEPARATORS APPLICATIONS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Series 1140 and 1141 Temperature Regulators

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

General safety precautions English

COLMAC COIL. Installation, Operation, and Maintenance ENG Rev A. Air Cooled Fluid Coolers. Contents. When you want Quality, specify COLMAC!

Transcription:

Instruction Manual Pharma-line ESE02198-EN 2012-05 Original manual

Table of contents The information herein is correct at the time of issue but may be subject to change without prior notice 1. Description... 4 1.1. Safety precautions... 4 1.2. Recycling information... 4 1.3. Application... 4 1.4. Design... 5 2. Installation... 6 2.1. Clearance for dismantling... 6 2.2. Foundations... 6 2.3. Levelling... 6 2.4. Cleanliness provisions... 6 2.5. Fittings and piping... 6 3. Operation... 7 3.1. Design and operating conditions... 7 3.2. Operating procedures... 7 4. Maintenance... 8 4.1. Inspection... 8 4.2. Indication of fouling... 8 4.3. Disassembly for inspection or cleaning... 8 4.4. Locating leaks... 8 4.5. Cleaning of the heat exchanger... 8 4.6. Gasket replacement... 8 5. Technical data... 9 5.1. Technical data... 9 5.2. Spare Parts... 10 3

1 Description 1.1 Safety precautions Installation - Always read the installation throughly. (See chapter 2, installation) - Always use a lifting crane or device when handling the heat exchanger. Operation - Always read the operation section throughly (See chapter 3, operation) - Never introduce hot fluid suddenly when heat exchanger is empty or cold. - Never shock the heat exchanger with cold fluid when hot. Transportation - Always transport the heat exchanger in its upright position. - Always ensure that the unit is securely fixed during transportation. - Never lift or elevate in any way other than described in this manual. 1.2 Recycling information Packing - Packing material consist of wood, plastics, metal - Wood can be reused, recycled or used for energy recovery - Plastics should be recycled or burnt at a licensed waste incineration plant. - Metal should be sent for material recycling. Maintenance - All metal parts should be sent for material recycling - All non metal parts must be taken care of in agreement with local regulations Scrapping - At end of use, the equipment shall be recycled according to relevant, local regulations. Beside the equipment itself, any hazardous residues from the process liquid must be considered and dealt with in a proper manner. When in doubt, or in the absence of local regulations, please contact the local Alfa Laval sales company. 1.3 Application The Alfa Laval Pharma-line is a high quality double tube sheet shell & tube heat exchanger designed for the pharmaceutical and biotechnology industries. The Pharma-line is used in pharmaceutical water systems: Water For Injection (WFI), Purified Water (PW), and for heating or cooling of pharmaceutical products. It is available in a number of standard sizes and meets the stringent hygiene standards imposed both by control authorities and industry. 4

1 Description 1.4 Design The Pharma-line is in hygienic design in accordance with FDA guidelines. The Pharma-line has no dead legs and is fully drainable on the product side. All product wetted parts in the Pharma-line are either electropolished to Ra <0.4 µm, or mechanically polishedtora<0.5µmorra<0.8µm. The tubes are seamless and polished prior to bending. The Pharma-line U-tubes are bent to a larger radius than required in ASME BPE. The Pharma-line is easy to clean and can be steam sterilized. The gaskets are FDA approved and USP class VI. Working principles In the Pharma-line the risk of mixing between the product and the heating or cooling (service) medium is eliminated as a result of the double tube sheet design. The product flows in the tubes while the service medium flows in a cross flow around the tubes, inside the shell. The service medium is sealed in the shell by the first tube sheet and the second tube sheet seals the product. In the event of a leak the leakage of either fluid is easily visually detected. 5300-0000 A=Tubesheets A Documentation The Pharma-line is delivered along with a complete documentation package, including - Approved drawings and pressure test certificate signed by Notified body according to ASME VIII division 1 classified Pharma-lines and Pharma-lines classified in category > III according to PED (97/23/EC). For Pharma-lines in category III Zetterströms Rostfria AB is certified to approve drawings and issue pressure test certificate for PED (97/23/EC) under Lloyds register (NB.No 0038) - List of welders, welding procedure and welder qualification - 3.1 Material certificates pressure and product wetted steel parts - FDA and USP class VI certificates gaskets - Liquid penetrant test report and procedure - Surface roughness certificate - Dimension control report - Pressure test certificate - Identification (technical sign) - Quality system certificate - CE documents Other documentation/procedures on request. 5

2 Installation The Pharma-line can be installed either horizontally or vertically. For an easy installation, lifting lugs and mounting plates are welded on the unit. 2.1 Clearance for dismantling Provide sufficient clearance at the stationary head side to permit dismantling of the Front head / Rear end cover and possible future inspection of the tubes. 2.2 Foundations Foundations must be adequate so that the exchanger will not settle and impose excessive strains on the exchanger. Foundation bolts should be set to allow for setting inaccuracies. 2.3 Levelling The heat exchanger must be set so that pipe connections can be made without forcing. However, small forces might be unavoidable, small forces are then acceptable, i.e. - acceptable forces in all directions on tube side are max 50 N - acceptable forces in all directions on shell side are max 100 N 2.4 Cleanliness provisions Connector protectors All exchanger openings should be inspected for foreign material. Protective plugs should not be removed until just prior to installation. Dirt removal The entire system should be clean before starting operation. 2.5 Fittings and piping By-pass valves It may be desirable for the user to provide valves and by-passes in the piping system to permit inspection and repairs. Test connections It may be desirable for the user to install thermometer well and pressure gauge connections close to the exchanger. Vents It may be desirable for the user to install vent valves close to the exchanger. Drains Drains may discharge into an open manifold. Pulsation and vibration Care should be taken to eliminate or minimize transmission of fluid pulsations and mechanical vibrations into the heat exchanger. Safety relief devices It is the users responsibility to install the required safety devices. 6

3 Operation 3.1 Design and operating conditions The heat exchanger must not be operated at conditions, which exceed those specified on the nameplate. If the heat exchanger surface temperature is expected to be hot or there are local regulations related to surface temperature, it is the users responsibility to either insulate the unit or take precautions by labeling the unit with a warning about the hot surface temperature in order to avoid risk for personnel injuries. 3.2 Operating procedures Before placing the heat exchanger in operation, reference should be made to the name plate for any special instruction. Local safety and health regulations must be considered. Improper start-up or shutdown sequences may cause leaking of tube-to-tube sheet and/or bolted flanged joints. It is the customers responsibility to carefully pay attention and doing a proper start-up and operation when running media with a higher risk for damages on the heat exchanger. Applies especially when running media below freezing-point (0 C). Start-up operation Dual Application If the heat exchanger is intended for dual application duties it should be allowed to come to ambient temperature between heating and cooling cycles. During start-up all vent valves should be opened and left open until all passages have been purged of air and are completely filled with fluid. Fluid must be introduced in a manner to minimize differential expansion between the shell and the tubes. Note! Adjustments of flow rates should be made slowly in order to avoid the risk of pressure surge (water hammer). Water hammer is a short-lasting pressure peak that can appear during start-up or shut-down of a system, causing liquids to travel along a pipe as a wave at the speed of sound. This can cause considerable damage to the equipment. Shutdown operation The heat exchanger must be shut down in a manner that minimizes different expansions between shell and tubes. When shutting down the system, the heat exchanger should be drained completely. Temperature shocks The heat exchanger should not be subjected to abrupt temperature fluctuations. Hot fluid must not be suddenly introduced when the unit is cold nor cold fluid suddenly introduced when the unit is hot. Bolted joints The heat exchanger is pressure tested before leaving the manufacturers shop in accordance with EN 13445 standard requirements for PED, or in accordance with ASME VIII standard requirements for ASME. However, normal relaxing of the gasketed joints may occur in the interval between testing in the manufacturer s shop and installation at the job site. Therefore, all external bolted joints may require retightening after installation and, if necessary, after the heat exchanger has reached operating temperature. Recommended bolt tightening procedure If the bolts are tightened it is important that they are tightened uniformly and in diametrically staggered pattern. 7

4 Maintenance 4.1 Inspection At regular intervals and as frequently as experience indicates, an examination should be made of the interior and exterior condition of the unit. Neglect in keeping all tubes clean may result in decreased performance of the heat exchanger. 4.2 Indication of fouling Heat exchangers subject to fouling or scaling should be cleaned periodically. A light sludge or scale coating on the tube greatly reduces its thermal efficiency. An increase in pressure drop and/or reduction in performance usually indicate that cleaning is necessary. The unit should first be checked for air or vapour binding to confirm that this is not the cause for the reduction in performance. Since the difficulty of cleaning increases rapidly as the scale thickness or deposit increases, the intervals between cleanings should not be excessive. 4.3 Disassembly for inspection or cleaning Before disassembly the user must assure that the unit has been depressurised, vented and drained. To inspect the inside of the tubes and also make them accessible for cleaning, remove the front head/read end cover. Always replace the Seal when the front cover is loosened to make sure that the Seal seals correctly. 4.4 Locating leaks The heat exchanger has double tube sheets and a leakage in the joint in the inner tube sheet will show as a leakage between the double tube sheets. A leakage in the joint in the outer tube plate will also show as a leakage betweenthedoubletubesheets. The following procedure may be used to locate perforated or split tubes inside the shell. - Remove the front head cover and apply pressure in the shell. Any leakage coming out of any tube shows a leakage in a tube inside the shell. 4.5 Cleaning of the heat exchanger The heat transfer surfaces of the heat exchanger must be clean to assure satisfactory performance. 4.6 Gasket replacement Remove the front head/rear end cover to replace the Seal. Tight the bolts after replacement of the Seal. It is important that bolts are tightened uniformly and in diametrically staggered pattern. The bolts should be tightened to first 15 Nm (for all bolts) then tighten the bolts to 30 Nm. Then tighten the bolts to 50 Nm and finally torque the bolts with full torque (70 Nm). 8

5 Technical data 5.1 Technical data Technical data Heat transfer area 0.1-8.5 m 2 (standard range) Design temperature 150 o C (available up to 200 o C) Design pressure FV/10 barg, higher pressures available Product wetted steel parts 316 L stainless steel, seamless tubes Gaskets PTFE (FDA compliance & USP class VI certified) Connections Tri-clamp on tube side and flanges on service side (other options available) Pressure vessel codes PED and ASME VIII (U-stamp as option) Welding according to ASME IX and EN-288-3, EN 287-1 Surface finish product wetted parts Electropolished with Ra<0.4 µm or mechanically polished with Ra <0.5 µm or Ra<0.8 µm Options - Passivation - Insulation Mineral wool (ASTM C795) with stainless steel 304 cladding - Removable tube bundle Custom made Other designs and documentation are available on request. 9

5 Technical data Standard units, measurements (approximate) B C M1 T2 T1 M2 A Type Shell OD (mm) A (mm) B (mm) C (mm) Pharma-line 1 Pharma-line 1-0.1 73 1200 180 860 Pharma-line 1-0.3 89 1200 190 860 Pharma-line 1-0.4 102 1200 190 860 Pharma-line 1-0.6 114 1200 200 860 Pharma-line 1-0.7 140 1200 210 860 Pharma-line 1-0.8 114 1200 200 860 Pharma-line 1-1.1 140 1200 210 860 Pharma-line 1-1.2 168 1200 220 860 Pharma-line 1-2.5 219 1200 253 860 Pharma-line 2 Pharma-line 2-0.3 73 2200 180 1860 Pharma-line 2-0.6 89 2200 190 1860 Pharma-line 2-1.0 102 2200 190 1860 Pharma-line 2-1.3 114 2200 200 1860 Pharma-line 2-1.4 140 2200 210 1860 Pharma-line 2-1.7 114 2200 200 1860 Pharma-line 2-2.4 140 2200 210 1860 Pharma-line 2-2.6 168 2200 220 1860 Pharma-line 2-5.5 219 2200 253 1860 Pharma-line 3 Pharma-line 3-0.4 73 3200 180 2860 Pharma-line 3-1.0 89 3200 190 2860 Pharma-line 3-1.6 12 3200 190 2860 Pharma-line 3-2.0 114 3200 200 2860 Pharma-line 3-2.2 140 3200 210 2860 Pharma-line 3-2.7 114 3200 200 2860 Pharma-line 3-3.7 140 3200 210 2860 Pharma-line 3-4.0 168 3200 220 2860 Pharma-line 3-8.5 219 3200 253 2860 Nozzle schedule Item Service Facing T1 Tube inlet Tri-Clamp Standard and dimension Free T2 Tube outlet Tri-Clamp Free M1 Shell inlet Weld neck flange Free M2 Shell outlet Weld neck flange Free 5.2 Spare Parts Gasket is available as spare part for Pharma-line. Replacement gaskets should be purchased in the material originally provided with your heat exchanger. Please refer to the heat exchanger serial no. or drawing no. when ordering replacement gasket. 10

11

How to contact Alfa Laval Contact details for all countries are continually updated on our website. Please visit www.alfalaval.com to access the information directly. Alfa Laval Corporate AB This document and its contents is owned by Alfa Laval Corporate AB and protected by laws governing intellectual property and thereto related rights. It is the responsibility of the user of this document to comply with all applicable intellectual property laws. Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), or for any purpose, without the expressed permission of Alfa Laval Corporate AB. Alfa Laval Corporate AB will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.