VarioAir Medical Suction Solutions Consumables and Accessories

Similar documents
VarioVac vacuum regulators Consumables and Accessories

Dräger Bump Test Station Calibration and Bump Testing

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Dräger Configuration and Evaluation Software

Dräger Catalytic Ex-Sensors DrägerSensors

D Moving beyond telemetry INFINITY M300

Portable wet chemical extinguishers

Dräger FRT 1000 / ETR 1000 Location Devices

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Foam Extinguisher AB - composite Portable foam extinguishers

Dräger QuadGard Control System

Powder Extinguisher ABC - composite Portable powder extinguishers

Dräger Pac 7000 Single-Gas Detection Device

Dräger VVP 1000 System Components

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

Training Gas Detection Level 3 Maintenance and Repair

Training Authorised Gas Tester Level 1. Basic Information

Tropic 2.0 ultrasonic nebuliser

Training Gas Detection Level 2 User and Calibration. Basic Information

On-site & Shutdown Safety Service CSE Monitoring

Dräger X-am 2500 Multi-Gas Detection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Flame 5000 Flame Detection

Foam Wheeled Extinguisher AB Movable fire extinguishers

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Pac 5500 Single-Gas Detection Device

Dräger X-am 5000 Multi-Gas Detection

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Bodyguard 1000 Warning Device

The SharpEye 40/40M (Multi IR) Flame Detection

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger P4000 Pressure and Leak Testing

Dräger OR Lights Simply good light

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger REGARD -1 Control System

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Oxylog VE300 Emergency & Transport Ventilation

Dräger Polytron 8000 Stationary gas detector (EC)

Oxylog VE300 Emergency & Transport Ventilation

Dräger Pac 3500 Single-Gas Detection Device

The SharpEye 40/40R (IR) Flame Detection

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

Dräger X-am 7000 Multi-Gas Detection

Dräger PIR 7000 Flammable Gas Detection

Dräger Pac 6000 Single-Gas Detection Device

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

Dräger Flame 5000 Flame Detection

Dräger Pac 8000 Single-Gas Detection Device

Oxylog 2000 plus Pocket Guide Software version 1.n

Dräger PEX 3000 Flammable Gas Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Pac 8500 Single-Gas Detection Device

Dräger REGARD 3900 Series Control System

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger X-zone 5500 Area Monitoring

The SharpEye 40/40I (IR3) Flame Detection

Dräger X-am 2500 Multi-Gas Detector

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger X-zone 5500 Multi-Gas Detection Device

Dräger PIR 7200 Detection of toxic gases and oxygen

Oxylog VE300 Emergency & Transport Ventilation

MT Always in focus BABYTHERM

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

The SharpEye 40/40I (IR3) Flame Detection

Dräger X-am 5000 Multi-Gas Detector

Infinity M300+ Telemetry

GS01 (wireless) Detection of flammable gases and vapours

Dräger X-zone 5500 Portable gas detection system for flexible area monitoring

Dräger DM-6 BG 4 Mask Dryer Workshop Systems

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

RVTM3 SUCTION VACUUM REGULATORS

RVTM3 SUCTION VACUUM REGULATORS

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection

ATMOS Surgical Suction

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Pac 3500 Single-Gas Detection Device

Dräger Polytron 8310 Stationary gas detector (DSIR)

Technical Datasheet. Suction Controllers, Flow Meters & Accessories

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

Ohio Medical s Push-To-Set TM Intermittent and Continuous Vacuum Regulators (ISO & ANSI)

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Surgical Suction: Silent and powerful!

ST More than the sum of their components GAS DETECTION SYSTEMS

Dräger Flame 2100 (UV) Flame Detection

Dräger X-zone 5500 Area Monitoring

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

ATMOS Bronchial Suction

SEPTIC FLUID ASPIRATOR MEDAP-VENTA SP 26 N MEDAP-VENTA SP 26 A

Transcription:

VarioAir Medical Suction Solutions Consumables and Accessories Whether in the operating room or in the intensive care unit, when it comes to suction, you need high-performance, reliable devices that are simple to operate. VarioAir suction solutions attain completely new standards of performance, safety and quality. Removable and mechanical coded manometer that can be rotated 360 Powerful suction capacity* Max. Vacuum -90 kpa Min. Suction flow 40 lpm Integrated pressure relief to avoid pressure increase at the patient side Universal rail bracket for medical rails (DIN, Fairfield, Carba, Uniflex, Duoflex) Integrated sound insulation for max. sound level of 57 db (A) Ergonomic hand wheel with push pull function for one handed operation VarioSafe filter system Aerosol and Fluid retention 100% Bacteria retention 99,99998% Virus retention 99,9998% * for bronchial suction D-28534-2009 Special version for use with oxygen e.g. for inner clinical transport

02 VarioAir Medical Suction Solutions Benefits VarioAir VarioAir assists you during suction by offering: a wide range of products for diverse tasks ergonomic hand valve for simple, one-handed operation integrated sound insulation (> 57 db (A)) integrated pressure relief valve, max. 10 mbar removable manometer that can be rotated 360 minimum 40 lpm suction flow** VarioSafe filter system: safe and hygienic thanks to bacteria (99.99998 %) and virus (99.9998 %) retention* special versions for use with oxygen universal rail bracket for medical rails (DIN, Fairfield, Carba, Uniflex, Duoflex) * according to Nelson Laboratories, Inc., Salt Lake City, USA ** w/o VarioSafe, w. VarioSafe 36 lpm Accuracy and durability for long term use Reliable devices are essential for bronchial suction, pediatric bronchial suction, drainage and thoracic drainage. VarioAir ejectors have been developed especially for these applications. As with all products in the VarioAir line, they have been manufactured precisely and with high-quality material. Every device bears the seal of quality Made in Germany. Switch on, control, and switch off with just one hand Even the best technological solution is of little help if it is difficult to operate. The VarioAir is currently the only regulator on the market that allows simple, one-handed operation. An ergonomic hand valve is all you need to control the continuous regulation, as well as the on and off switch. This means you always have one hand free for your patient. Extract large quantities quickly and quietly The VarioAir helps you extract large quantities of secretion, blood and other liquids. VarioAir offers a novel 2-level chip ejector. This allows you to extract up to 50 liters per minute* in no time at all. And all this with very little noise: the integrated sound insulation reduces noise pollution to 57 db (A). *at 5.5 bar operating pressure Play it safe with manometer and valve You can remove and rotate all VarioAir manometers. They can be turned 360 degrees to allow you to read the vacuum setting in any position at the patient s bed. As the manometers are mechanically coded, they cannot be

VarioAir Medical Suction Solutions 03 Benefits confused or connected incorrectly. Excess pressure is eliminated as soon as it occurs: VarioAir is equipped as standard with an integrated pressure relief valve (max. 10 mbar). VarioSafe: germs simply eliminated The VarioSafe filter system is proven to retain germs: 99.99998 % of bacteria and 99.9998 %* of viruses. When combined with the VarioSafe you are, therefore, not only protecting your VarioAir device, but also your environment. The VarioSafe filter system has been especially developed for the VarioAir product range and subjected to extensive testing. * according to Nelson Laboratories, Inc., Salt Lake City, USA

04 VarioAir Medical Suction Solutions Technical Data VarioAir B -90 to 0 kpa (-900 to 0 mbar) Minimum suction flow 40 L/min 57 db (A) VarioAir P -48 to 0 kpa (-480 to 0 mbar) Maximum suction flow 20 L/min 50 db (A) VarioAir D -16 to 0 kpa (-160 to 0 mbar) Maximum suction flow 18 L/min 45 db (A) Inlet pressure range 4 to 5.5 bar Pressure relief valve ex 0.1 kpa (10 mbar) Weight 800 g 1,600 g (for VarioVac compact, empty) Dimensions (W/H/D) in mm 80 x 200 x 160 (without VarioSafe ) 80 x 330 x 160 (with VarioSafe ) 300 x 440 x 160 (VarioAir compact) Hose nozzle Ø 6 mm Bacterial retention 99.99998% (with VarioSafe ) Viral retention 99.9998% (with VarioSafe ) VarioAir T Rail WV -5 to 0 kpa (-50 to 0 mbar) Minimum suction flow 15 L/min Max. gas consumption 30 L/min Weight 1,100 g Dimensions (W/H/D) in mm 80 x 860 x 160 50 db (A) Hose nozzle Ø 6 mm Ordering Information VarioAir B DIN Bronchial suction. German standard (DIN) MP00530 VarioAir B BS Bronchial suction. British standard (BS) MP00531 VarioAir B AFNOR Bronchial suction. French standard (NF / AFNOR) MP00532 VarioAir B AGA Bronchial suction. Swedish standard (AGA) MP00533 VarioAir B UNI Bronchial suction. Italian standard (UNI) MP00534

VarioAir Medical Suction Solutions 05 Ordering Information VarioAir B CARBA Bronchial suction. Swiss standard (CARBA) MP00548 VarioAir 02 B CARBA Bronchial suction. Swiss standard (CARBA) MP00551 VarioAir 02 B DIN Bronchial suction. German standard (DIN) MP00550 VarioAir B/ OR rail Bronchial and operating theatre suction. Connecting thread NIST-AIR MP00535 VarioAir 02 B/ OR rail Bronchial and operating theatre suction. Connecting thread NIST-O2 MP 00552 VarioAir B compact Bronchial suction. Complete system with secretion bottle package and integrated MP00536 VarioAir. Connecting thread NIST-AIR VarioAir D DIN German standard (DIN) MP00537 VarioAir D BS British standard (BS) MP00538 VarioAir D AFNOR French standard (NF/ AFNOR) MP00539 VarioAir D AGA Swedish standard (AGA) MP00540 VarioAir D UNI Italian standard (UNI) MP00541 VarioAir D CARBA Swiss standard (CARBA) MP00549 VarioAir D rail Connecting thread NIST-AIR. MP00542 VarioAir T rail WS Thoracic drainage. Connecting thread NIST- MP00544 AIR. VarioAir P rail Pediatric bronchial suction. Connecting thread NIST-AIR. MP00545 VarioAir P compact Pediatric bronchial suction. Complete system with secretion bottle package and MP00547 integrated VarioAir : Connecting thread NIST-AIR VarioSafe Disposable filter system for VarioAir. Delivery MP00555 batch: 10 items VarioAir is a registered trademark my Dräger. Maximum and minimum values apply to the inlet pressure range of 4 to 5.5 bar.

90 66 481 15-06-4 Communications & Sales Marketing PP LE Printed in Germany Chlorine-free environmentally compatible Subject to modifications 2015 Drägerwerk AG & Co. KGaA 06 VarioAir Medical Suction Solutions Notes CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com Manufacturer: Dräger Medical GmbH Moislinger Allee 53-55 23558 Lübeck, Germany As of August 2015 Dräger Medical GmbH changes to Drägerwerk AG & Co. KGaA Locate your Regional Sales Representative at: www.draeger.com/contact REGION EUROPE CENTRAL AND EUROPE NORTH REGION MIDDLE EAST, AFRICA Dräger Medical GmbH Moislinger Allee 53-55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com Dräger Medical GmbH Branch Office P.O. Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draeger.com REGION EUROPE SOUTH REGION ASIA / PACIFIC Dräger Médical S.A.S. Parc de Haute Technologie d'antony 2 25, rue Georges Besse 92182 Antony Cedex, France Tel +33 1 46 11 56 00 Fax +33 1 40 96 97 20 dlmfr-contact@draeger.com Draeger Medical South East Asia Pte Ltd. 25 International Business Park #04-27/29 German Centre Singapore 609916, Singapore Tel +65 6572 4388 Fax +65 6572 4399 asia.pacific@draeger.com The quality management system at Dräger Medical GmbH is certified according to ISO 13485, ISO 9001 and Annex II.3 of Directive 93/42/EEC (Medical devices). REGION CENTRAL AND SOUTH AMERICA Dräger Panama Comercial S. de R.L. Complejo Business Park, V tower, 10th floor Panama City Tel +507 377 9100 Fax +507 377 9130 contactcsa@draeger.com