7.0 GENERAL 7.1RISK ASSESSMENT. STEP 1: DEFINE THE PROJECTS/TASKS Project Proponents : M/s. Goel Ganga Developers (I) Pvt. Ltd

ERDMP & RISK ASSESSMENT REPORT

Proposed Commercial Project at Plot No. C3A, Sector-16B, Greater Noida West (U.P)

DISASTER MANAGEMENT PLAN 3.0 IDENTIFICATION OF MAJOR HAZARD POTENTIAL

M.P. Bhawan Risk Assessment. Chankya Puri, New Delhi

DMP & RISK MANAGEMENT PLAN

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

Enclosure 4- RISK ASSESSMENT

7.2 SAFETY CODE FOR BUILDING & FIRE FIGHTING SYSTEM

RISK ASSESSMENT, ITS MITIGATION & DISASTER MANAGEMENT PLAN

Contingency/Emergency Plan for all Hazards Page 1 of 9

Truro Police Department. Fire Emergencies. Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE:

School EMERGENCY PLAN

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

COUNTY OF ALAMEDA County Administrator s Office Risk Management Unit th Street, 3 rd Floor, Oakland, CA 94607

RISK ASSESSMENT, DISASTER MANAGEMENT AND SAFETY MEASURES (ONSITE & OFFSITE)

Emergency Evacuation Plan South Patterson Building (SPB)

Be Safe and Be Prepared! EMERGENCY PREPAREDNESS QUICK-REFERENCE GUIDE. YOUR CURRENT LOCATION Building/Address: Room Number:

UNCONTROLLED IF PRINTED. Issued with the authority of the Chief Commissioner and General Manager of Scouts Australia NSW

Emergency Action Plan. Revised: 1/22/2018

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University BLUE BAND BUILDING ( )

Workplace Safety North

EIA REPORT OF PRATHAM RIVIERA (M/S. PRATHAM DEVELOPERS), BILL VILLAGE, VADODARA.

PROCEDURE FOR EMERGENCY PREPAREDNESS AND RESPONSE

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University

WHAT IS FIRE DISASTER? Fire Disaster is an occurrence or an incident of such magnitude which creates a situation in which the normal life is suddenly

Health and Safety Plans Health and Safety Policy Statement Fire Prevention Plan Objective

Emergency Evacuation Plan. Kettering Labs. School of Engineering

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator.

Environmental emergency preparedness and response

SCALES NW EMERGENCY ACTION PLAN

FACILITY OF EMERGENCY PLAN. (Template)

Hospital Codes, Safety, Exposure Control, Emergency Plans Handout

RISK ASSESSMENT. Prepared by:-m/s PerfactEnviro Solutions Pvt. Ltd. 76. M/s Alton Buildtech India Pvt. Ltd.

5.0 CONTINGENCY PLAN. It is necessary to amend the plan if:

RISK STUDIES. Housekeeping practices requiring contact with solid and liquid wastes

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University

RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN

Mukwonago Community Library Emergency Procedures

RAMBLER PARK FIRE SAFETY INFORMATION

Livingston Intl. Emergency Procedures Guide

SAFETY BEGINS WITH YOU!

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

A. RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN

Section 5 Brieser Construction SH&E Manual

ESF 15: EMERGENCY PUBLIC INFORMATION

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University ARTS COTTAGE ( )

2012 SunTrust Center ERT Annual Review. 919 East Main St. Richmond, VA

VICI. Emergency Evacuation Plan

TABLE OF CONTENTS. Medical & First Aid Procedure 11, 12. Hazardous Material Emergency Response 17. Civil Disturbances and Demonstrations 21

Liberal Arts and Humanities. Building # 275. Emergency Evacuation Plan

Policy and Organizational Statements

FIRE PROTECTION PROGRAM

Proposed construction of National Institute of Homeopathy at Sec-A8, Narela Delhi by Ministry of Ayush. Risk Assessment

Chapter 7: ADDITIONAL STUDIES

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

Emergency Action Plan

Harvard University - OEB Glasshouse Emergency Evacuation Plan

Chapter 7: ADDITIONAL STUDIES

1.1.1 HAZARD IDENTIFICATION

Chapter 1: ADDITIONAL STUDIES

Emergency Codes. Student Orientation Centre for Education. Modified September 2017

Management Practices: Fire Protection Impairments November 2015

EMERGENCY RESPONSE GUIDEBOOK South Hamilton Campus February 2016 Reviewed and Updated

North West Regional Center SITE EMERGENCY RESPONSE PLAN

Written Fire Safety Plans

GEORGIAN COLLEGE OPERATING PROCEDURES & PRACTICES. Revised Responsible Procedure Date: Department: Administration Number: LOCKDOWN

RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN 1.1 RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN

HEALTHWEST PROCEDURE. No Prepared by: Effective: February 6, 2008 Revised: June 5, 2017 Environment of Care Committee

Vancouver Convention Centre Safety and Security Guide AME Roundup 2018 January 22-25, 2018

Non-Emergency Direct Line Telephone Numbers. Emergency Direct Line Telephone Numbers

BUILDING EMERGENCY ACTION PLAN

BUILDING EMERGENCY ACTION PLAN. for Your Building Name

DEF Fire Evacuation and Emergency Planning Criteria

Emergency procedures flip book

Campus Emergency Procedures Guide

APPENDIX 4J SECURITY AND SURVEILLANCE SERVICES

BUILDING EMERGENCY ACTION PLAN

SAFETY BEGINS WITH YOU!

Establishment of new clinker grinding unit capacity Million TPA (OPC & PPC Cement), at village - Satha, Tehsil - Koil, District - Aligarh (UP)

West Virginia University Health Sciences Center Campus Emergency Preparedness Instructions for

Emergency Preparedness General Response

Property Name & Address [ Property Name ] - [ Property Address ]

Change Made by (Signature)

Safety Plan. 2/1/2012 Page 1

Regulations Regarding Emergency Planning & Preparedness for Long Term Care Facilities. Regulation Explanation Document Reference

Emergency procedures flowcharts

FIRE PREVENTION PLAN EMERGENCY ACTION

Emergency Action Fire Prevention Plan

Emergency Preparedness Guide

NATIONAL COMPETENCY STANDARD

NOTTINGHAM CITY HOMES

Emergency Response Guide

Emergency Codes. Student Orientation Centre for Education. April 2014

Life Safety Plan Updated January 2017

CENTRAL LIBRARY EMERGENCY PROCEDURES MANUAL

Who am I?? Trade this -- And this-- for this. HSVMA Webinar Just in Case: Essentials of Disaster Preparedness for The Veterinary Clinic

Health & Safety Plan For Emergencies Dixon and Coal Creek Buildings

Training Toolbox Series. ICA11v1.0 Information, Digital Media & Technology

Transcription:

DMP FOR ONSITE AND OFFSITE Disaster is a threat to Environment and Society. Disaster Management Plan (DMP) deals with the preparations to reduce the impacts of Natural and Man-made disasters. Recent rise in the incidence of disasters has alerted us regarding the need of pre-planned DMP which will aim at providing effective and timely relief during disaster through organized manner. Emergency prevention through good design, operation, maintenance and inspection are essential to reduce the probability of occurrence and also making the occupiers aware of what to do in case of any emergency. The overall objective of a disaster management plan is to make use of the combined resources created or available at the site and/or off-site services to achieve the following: Prevent Disasters; Minimize the effects of the accident on people and property; Initiate the rescue and medical treatment of casualties; Safeguard other people Evacuate people to safe areas with care Inform and collaborate with statutory local and state authorities; Provide credible information to news media; Bring the incident under control; Preserve relevant records and equipment for the subsequent enquiry into the cause and circumstances of the emergency; Investigate and take steps to prevent recurrence of similar incidents. DMP follows the Basic structure as shown in Figure FIGURE: BASIC STRUCTURE OF DMP DISASTER MANAGEMENT PLAN NATURAL MANMADE EARTHQUAKE FLOOD CYCLONE LIGHTENING FIRE ACT OF TERROR POWER FAILURE 1

I. NATURAL DISASTER A. EARTHQUAKE SEISMIC ENVIRONMENT & PRECAUTIONS As per the Seismic Zoning Map of India, Raigad region falls under Seismic Zone-III. The structural design shall be certified as per IS code 875 and IS- 1893-2002 for Seismic Zone III of Thane. B. FLOODS Areas having poor drainage characteristic get flooded by accumulation of water from heavy rainfall. Following precautions would be taken by M/s. Puranik Builders Pvt. Ltd. to manage flood disasters: M/s. Puranik Builders Pvt. Ltd. proposes: a. Storm water system would be checked and cleaned periodically. b. Mapping the areas within or leading in or out of the building that will be water logged, flooded or isolated due to the flood. The areas will be marked after completion of the project (as final ground levels etc. will be available after completion). c. Vulnerability of basements should be mapped. d. Dewatering pumps shall be installed at vulnerable locations. C. CYCLONES Cyclones are caused by atmospheric disturbances around a low-pressure area distinguished by swift and often destructive air circulation. They are usually accompanied by violent storms and bad weather. There is no history of any cyclone in this area. However in such an instance the occupants should be advised to stay in the shelter in tightly secured windows and doors. The glass of windows etc. should be covered with paper/cardboards to avoid glass breaking due to flying objects outside. D. LIGHTNING Lightning is an atmospheric electrostatic discharge accompanied by thunder which typically occurs during thunderstorms and sometimes during volcanic eruptions or dust storms. It often leads to physical damage to the building and occupants. It can also lead to short circuits, failure of power supply and fire. Lightning arrestor systems is provided to abate the impact of lightning hazard. 2

II. MAN-MADE DISASTER A. FIRE Fire could take place through various means; one of them is through electrical fire. Hence, all the electrical works and material of the building would adhere to the standards. Regular maintenance and audit of the electrical systems would be carried out by external auditors. Fire alarm would be installed. The functioning of these fire alarms would be checked periodically by security manager. A report of the same would be submitted to safety manager. The same report would be submitted to Safety manager. The same report must be submitted to M/s. Puranik Builders Pvt. Ltd. for necessary action. The occupants of the proposed building would undergo mock fire drills. These mock drills would be conducted by qualified staff (e.g. fire brigade).fire extinguishers would be placed in every floor. All occupants would be given training on how to use these fire extinguishers. Fire extinguisher equipment would be evaluated periodically to ensure that it is in working conditions by security manager. If any faulty equipment is observed then it would be repaired or replaced by Society. Proper evacuation plan would be chocked for the building. The map for the evacuation plan would be provided to all the occupants. The Emergency Preparedness programme shall comprise the following elements: a. Fire Safety System i. Active Fire Fighting Refuge areas as per CFO Norms Proper Fire Escape routes Adequate underground tank Capacity : 100 m 3 for each building Overhead tank of capacity 20 m 3 for each building Wet Riser Installation shall confirm to internal diameter of 15 cms. Of G.I. C class for installation of fire Hydrants. Fire Detection system & Fire Alarm system will be provided for the entire building & main control panel should be installed in the fire control room. Automatic Sprinklers & fire extinguisher External & internal Hydrant Active Fire protection system Fire Alarms & communication system Automatic Detection system design shall be as per latest IS 2189. ii. Evacuation Fire Lifts provided. Floor plans showing evacuation routes and signage are depicting locations. Photo luminescent marking, guiding occupants to evacuation passages and assembly areas. b. Response Sequence during Fire i. Person noticing the fire should attempt to isolate and extinguish the fire with the available equipment and inform or arrange to inform the security regarding the: Location of the fire Material of burning Extent of fire 3

Callers name and number A proper code of communication shall be maintained wherein the caller makes sure that the message has been conveyed to the right person. ii. Security or the coordinators will Respond to the scene of the incident. Arrange to send the necessary fire fighting equipment to the scene of the incident. Extinguish the fire with the available equipment. Ensure closure of gates immediately to regulate traffic in such a way that free movement of outside assistance like fire tenders, ambulance etc is available. Security will cordon off the area and local city fire fighting staff should be notified for further assistance. All the occupants will need to stop their operations/ work, switch off lights, fans, machines etc. All persons should assemble to refuge or designated area for fire and hazardous situation. iii. Reporting and Follow up System All cases of fire occurrence, no matter how small, must be reported promptly to the Security for further action to avoid such incident. Fire extinguishing equipment once used, should not be returned to its location without it is being recharged/ certified fit by the security. All fire extinguishers after use should be laid horizontally to indicate that they have been exhausted. iv. Refuge Area The Refuge Area will have the following resources available: Copies of the Disaster Management Plan. Layout Plan of the complex. Information regarding Safety Equipment, Fire Fighting material. A list of important telephone numbers like those of neighbouring police station, Fire Brigade, Hospitals etc. First - Aid Kit. Communication equipment - Internal and External telephones and other communication equipment. Drinking water facility. In addition to many of the above measures an attempt will be made to add any site specific steps and manpower based instruction. Instruction should be in multiple languages including Marathi and Hindi. The communication equipment will be checked periodically to ensure that they are functional. 4

B. ACT OF TERROR The project site is situated in well developed Thane region. Hence act of terror can occur. An explosive device assimilated into an object which will be left to explode once its owner has withdrawn from the area of the explosion after placing it. An Explosive device is known more as a "bomb-bag" or an "unidentified object" a. Suspicious Signs List i. The vehicle is not in the right place ii. The vehicle has breaching signs iii. The vehicle has been altered iv. The vehicle is extremely heavy (is sunk) v. The vehicle has flammable materials and is not coordinated to come to the Hotel vi. The vehicle has irregular smell of gasoline, solar, etc. vii. The vehicle plates have irregularities: not synchronized, number changed by hand, new vehicle with old plate, no plates viii. The vehicle has bulges, wires, etc. that do not seem to be part of the vehicle ix. The identification papers look fake, altered, not proper, no papers. Also regarding deliveryinvoices. x. The driver is not cooperating, nervous xi. The vehicle is abandoned in a hastily manner near a crowded area xii. Weight does not fit the size. xiii. External oily signs. xiv. Kept extremely close to the owner. xv. Left without care xvi. Does not want it to be checked. xvii. Does not look like it fits the owner. The suspicious sign list will be obtained from local police station such as names, sketches of persons, photos etc. Such person shall be denied entry or detained at security checking, it will be informed to local police station. b. Hostage Situation A hostage situation is a situation where one or more suspects are holding one or more people in confinement in a closed area and threatening their life. The main aim of the Proposed building Security is to safeguard the situation until a professional police force will step in to negotiate and terminate the event. The declaration of a hostage situation will be done by the Security. Hosted situation will be handled by police department. C. POWER FAILURE Power failure is a short- or long-term loss of the electric power to an area. Failure of electrical power to a building will have a serious impact on its operations, particularly if the failure occurs during normal operating hours when the building is fully occupied. a. Causes Of Power Failure There are many causes of power failures in an electricity network which are caused by either of the following faults: i. Manmade / Technical Fault Faults at power stations, 5

Damage to electric transmission lines, substations or other parts of the distribution system, Short circuit, Overloading of electricity mains. Collision of person or object with utility poles or power transformers, Human error in operating equipment within the building or outside (such as at the utility company supplying the power), or malicious tampering. ii. Natural Events. Natural events include storms, floods, and earthquakes, Lightning. b. Types Of Power Failure Power failures are categorized into three different phenomena, relating to the duration and effect of the failures: i. A transient fault is a momentary (a few seconds) loss of power typically caused by a temporary fault on a power line. Power is automatically restored once the fault is cleared. ii. A brownout or sag is a drop in voltage in an electrical power supply. iii. A blackout refers to the total loss of power to an area and is the most severe form of power outage that can occur. c. Effects Of Power Failure i. Loss of visibility ii. Safety is at risk. iii. Stoppage of elevators. iv. Computer memory loss and equipment damage. v. Stoppage of working of Fire fighting system. vi. Stoppage of working of building utilities like water pumps, Sewage treatment plants etc. vii. Loss of comfort. d. Mitigation plan Buildings have emergency and standby power systems to provide safety and comfort to building occupants during interruptions in their normal power supply. i. Diesel Generators A diesel generator is the combination of a diesel engine with an electrical generator (to generate electric energy. Diesel generating sets are used in places without connection to the power grid or as emergency power-supply if the grid fails. The packaged combination of a diesel engine, a generator and various ancillary devices (such as base, canopy, sound attenuation, control systems, circuit breakers, jacket water heaters and starting system) is referred to as a generating set. In case of emergency these diesel generators will backup for electric supply for the common area lighting and utilities like elevators, water pumps, fire lifts, fire pumps & Sewage Treatment plant etc. ii. iii. Provision of Independent electrical circuits for critical equipments as per Norms Also as per specific requirement of Fire fighting department the Electric supply for Fire pumps, booster pumps, sprinkler pumps will be on independent circuit. Uninterruptible power supply (UPS) Uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup is an electrical apparatus that provides emergency power to a load when the input power source, typically the utility mains, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide instantaneous or near-instantaneous protection from input. 6

Even if DG sets are provided as power backup a UPS is typically used to protect computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss. iv. Power Outage Tips : Check to see if others are without power. If your flat is the only one without electricity, check your fuse box and if needed call an electrician. Turn off appliances that were running before the outage to protect the motor. Turn off the Television, computers, air-conditioning system, and refrigerator. If stucked in elevator, Please be patient, it only takes a few minutes to get out of the elevator once the backup system is on. III. ONSITE AND OFFSITE EMERGENCY PREPAREDNESS PLAN A. On Site Emergency Preparedness plan : a. Mitigative measures in the Construction phase / O & M of Equipments and facilities: i. Regular health check up of construction workers ii. Adequate safety instructions to given to all employees. iii. Provide necessary protective equipment, safety appliances e.g. safety helmet, goggles, welder s equipment for eye and face protection, earplugs, safety belt, hand gloves, safety shoes and clothing, and to ensure their proper use. iv. Create awareness of employees about materials, equipment or processes used in their work, which are known to be potentially hazardous to health or safety v. Keep all operations and methods of work under regular review for making necessary changes from the point of view of safety in the light of experience and up-to-date knowledge. vi. Provide appropriate facilities for first aid and prompt treatment of injuries and illness. vii. Proper implementation of fire prevention methods and an appropriate fire fighting service. viii. Maintain collection of data on accidents with a view to take corrective, remedial and preventive action ix. Regular safety inspection by a competent person at suitable intervals of all buildings, equipment x. The working personnel will be given the following appropriate personal protective safety gears xi. Display of Emergency phone nos. (E.g. nearby hospitals, fire station, police stations, etc.) at following places : At security cabin At the entrance Near the lift doors on all the floors and at every staircase landing on every floor All occupants shall be provided the copy of these documents and shall be asked to keep handy. xii. Training to all occupiers for different type of emergencies. xiii. Periodic maintenance and checking of all equipments. B. Offsite Disaster management plan: a. Safeguard Requirements for Natural and Manmade Disasters List of Nearest Clinics and Hospitals shall be maintained for medical emergency as also any other Eventuality. The table below will be ready and will be distributed to all members within the building and later for off-site plan to neighbourhood. These information need to be updated every six months before safety drills. The information thus updated should also be shared with occupants. Table : Emergency Situation Clinics and Hospitals 7

Sr. Names and Area of Location Distance (Km) Phone numbers No. specialization 1. Dhanwantari Multispeciality Thane Within 0.46 Km 022-6515 0063 Hospital 2. Shree Sai hospital Thane Within 0.82 Km 91-9821070242 3. Hiranandani hospital Thane Within 2.73 Km 022-2545 8666 4. Bethany Trust Lok hospital Thane Within 5.41 Km 022-21719981 5. Sai Prasad Ambulance Thane Within 6.16 Km 91-9869577382 6. Pushpak Ambulance Service Thane Within 5.97 Km 022-25438499 Table : Emergency Situation Government Agencies and Offices Sr. Names and Area of Location Distance Phone numbers No. response 1. Police (Law and Order) Kapurbavdi Police Station Within 7.15 Km 022-25340098 2. Fire Brigade Balkum Fire Within 6.59 Km 022-25366702/ brigade 25366401 3. Railways Station of Thane Within 9.65 Km 022-25331143 4. MSRTC Depot Manager, Thane 5. MSEB ( Power) Assistant Engineer, Thane b. OFF-SITE EMERGENCY COVERAGE Within 10.19 Km 022-25332504 Within 3.31 Km 022-25367548/ 25333411 Off-site plan addresses all issues which can have impact out-site of the site. Off-site Emergency Plan has many components which need to be in place for effective plan. i. Organization: There shall be warning systems, implementation procedures, and emergency control centers. In addition it also needs telephone numbers of related emergency key personnel. (E.g. fire station, police station, hospitals, etc.) ii. Communications: The communication part warrants the complete identification of personnel involved, call signs, and lists of telephone numbers of all concerned. The clarity of communication is key to effective off-site emergency plan. The Disaster Management Plan control system should be installed in the building, which will assist the DMC and the occupant in the case of emergencies. iii. Voluntary organizations and NGOs: A complete list of details of organizers, telephone numbers, resource availability that is in the vicinity will need to be maintained. They would be asked to share their views on improving the environmental awareness and structure of the society. iv. Humanitarian arrangements: Emergency feeding treatment of injured, first aid, related information shall be arranged. v. Role of the Implementing Authority (Local Authority): The local authority will carry out his duty in preparing for a whole range of different emergencies within their jurisdiction area. The responsible person will coordinate to obtain the information to provide the basis for the plan. This liaison should ensure that the plan is continually up dated and communicated to all stake holders. It will be the responsibility of the local authority to ensure that all those organizations, which will be involved off site in handling the emergency, know of their roles and responsibility. Sufficient staff and appropriate equipment arrangement shall be responsibility of respective person. Rehearsals for off-site plans should be organized by the local authority. 8

vi. vii. viii. ix. Role of Police Department: Formal duties of the police during an emergency include protecting life and property and controlling traffic movements. Their functions should include controlling bystanders, evacuating the public, identifying any serious problems, and informing all concerned. Role of Fire Authorities: The control of a fire should normally be the responsibility of the senior fire brigade officer who would take over the handling of the fire from the site controller on arrival at the site. The senior fire brigade officer should also have a similar responsibility for other events, such as explosions and toxic release. Fire authorities in the region should be apprised about the location of all stores of flammable materials, water and foam supply points, and fire-fighting equipment. They should be involved in on-site emergency rehearsals both as participants and, on occasion, as observers of exercises involving on-site personnel. Role of Health Authorities: Health authorities, including doctors, surgeons, hospitals, ambulances, and similar other persons/institutions should have a vital part to play following a major accident, and they should form an integral part of the emergency plan. Major off-site incidents are likely to require medical equipment and facilities in addition to those available locally, and a medical "mutual aid" scheme should exist to enable the assistance of neighboring authorities to be obtained in the event of an emergency. Occupational Health and Safety: The facility will have many activities involved during construction, erection, testing, commissioning, operation and maintenance, where manpower materials and machines are the basic inputs. Occupational health and safety of all the people concerned will be a major part of the facility. The proposed facility to mitigate and minimize the adverse impacts of process, if any, has to ensure provision of appropriate and adequate occupational health and safety measures, including fire plans. Conclusion M/s. Puranik Builders Pvt. Ltd. will periodically review and update the Disaster Management Plan and will take the initiative to institutionalize the relationship between all Emergency Security and Rescue Forces (e.g. Police, Municipality, Fire Brigade, Medi-Care Centres etc.) 9