ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Similar documents
ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Insulation fault evaluator EDS460-DG

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

Operating Manual RCM420

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Operating Manual VMD420

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

CMD420 / CMD421 Series

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Remote alarm indicator and test combination MK2430

VME420 Voltage and frequency monitor

VME421H Voltage and frequency monitor

RCMA423. Residual current monitor for monitoring AC-, DC- and pulsed DC currents in TN- and TT systems Software-Version: D330 V1.0x.

Bender GmbH & Co. KG. All rights reserved. Reprinting only with permission of the publisher. Subject to change! Photos: Bender archives

Manual CME420. Multi-functional current relay, AC, overcurrent/undercurrent/ window discriminator function CME420_D00034_02_M_XXEN/05.

LINETRAXX RCMS460-D/-L RCMS490-D/-L

BENDER A-ISOMETER IRDH265 IRDH365

ISOMETER IRDH265 IRDH365

IT system floor-standing distribution

RCMA423-DM1C Residual current monitor

ISOMETER IRDH375 IRDH375B

Line Isolation Monitor (LIM) LIM2000plus

A-ISOMETER IRDH575. Operating Manual

Bender GmbH & Co. KG All rights reserved. Reprinting only with permission of the publisher. Subject to change! Photos: Bender archives.

Process Alarm Module RTA 421

TM800. Remote alarm indicator and operator panels

LINETRAXX RCMS150. Residual current monitor type B with integrated measuring current transformers for earthed AC/DC systems (TN and TT systems)

T M LIM2010. Line Isolation Monitor (LIM) Technical Bulletin NAE /

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

IR5002. Operating Manual. Insulation monitoring device for IT DC systems V ISO Quality System Certified

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

ISOMETER isopv1685rtu isopv1685p isopv1685pfr

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Parameterisable compact fault annunciator with permanent display

Universal fault annunciator for panel mounting

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

PolyGard 2-channel Gas Controller MGC-03

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

PROTECT SRB 200EXi-1A

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating Manual MS220KA and MSR220KA

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

ACS-30-EU-EMDR- 10-MOD

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Analog Annunciator Unit SACO 16 A3. Product Guide

02/11/2015

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Interface and EOL Modules 8

Operating Manual MSF220V(VU)

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Annunciator Unit SACO 16 D1. Product Guide

T M. User Manual LIM2010. Line Isolation Monitor

MSM - Expansion modules

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Electrical safety costs little. a human life is priceless

REA 105 Arc Protection Module. Operator s Manual

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

SCHMIDT LED Measured Value Display MD Instructions for Use

Annunciator unit. Application

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

Capacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING. Manual

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Monitoring Devices 11/1

TCM-2 Thyristor Control Module DATA SHEET

Universal controller for panel mounting Models CS6S, CS6H, CS6L

MK Series. Remote Indicators For Line Isolation Monitors and Fault Location. Technical Bulletin NAE /

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

AO Annunciator Module

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

02/11/2015

Operating Manual TR600

M15051) INSTRUCTION MANUAL

EUROFLAT SERIES TYPES C... S... M...

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

FLAME AMPLIFIER MODULE 3001

EUROBOX SERIES TYPES CM... SM... MM...

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Operating Manual MS220DA

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Transcription:

Insulation monitoring device for unearthed AC/DC control circuits (IT systems) TDB103005en/05.2013

Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Product description The ISOMETER s of the IR425 series monitor the insulation resistance of unearthed AC/DC control circuits (IT systems) 0 300 V. DC components existing in AC/DC systems do not influence the operating characteristics. An external supply voltage allows de-energised systems to be monitored too. ISOMETER IR425 Device features Insulation monitoring for AC/DC control circuits 0 300 V Two separately adjustable response values Preset function (automatic setting of basic parameters) Connection monitoring system/earth LEDs: Power On, Alarm 1, Alarm 2 Internal/external test/reset button Two separate alarm relays (one changeover contact each) N/O or N/C operation, selectable Fault memory behaviour, selectable Self monitoring with automatic alarm Multi-functional LC display Adjustable response delay Two-module enclosure (36 mm) Push-wire terminal (two terminals per connection) Approvals Application AC/DC control circuits in the industrial sector, mechanical engineering, power plants, elevators, automation systems etc. AC/DC control and auxiliary circuits in accordance with DIN EN 60204-1 Electrical equipment of machines, IEC 60204-1, EN 60204-1 AC/DC auxiliary circuits in accor dance with DIN VDE 0100-725 (VDE 0100-725) Smaller AC/DC IT systems such as lighting systems Function The currently measured insulation resistance is indicated on the LC display. In this way any changes, for example when circuits are connected to the system, can be recognised easily. When the value falls below the preset response values, the response delay t on starts. Once the response delay t on has elapsed, the alarm relays K1/K2 switch and the alarm LEDs AL1/AL2 light up. Two separately adjustable response values/alarm relays allow a distinction to be made between prewarning and alarm. If the insulation resistance exceeds the release value (response value plus hysteresis), the alarm relays return to their initial position. Insulation faults are distinguished according to AC and DC faults (indication ±). If the fault memory is enabled, the alarm relays remain in the alarm state until the reset button is pressed or until the supply voltage is switched off. The device function can be tested using the test button. The parameterisation of the device can be carried out via the LC display or the function keys integrated in the front plate. Connection monitoring The connections to the system (L1/L2) and to earth (E/KE) are either automatically checked every 24 h, or by pressing the test button or when supply voltage has been connected. In case of interruption of a connecting lead, the alarm relay K2 switch, the LEDs ON/AL1/AL2 flash and the following message appears on the display: E.02 signals a fault in the connecting leads to the system, E.01 signals a fault in the connecting leads to PE. After eliminating the fault, the alarm relays return to their initial position either automatically or by pressing the reset button. Preset function After connecting the device for the first time, the nominal system voltage is measured and the response values are set automatically. Measurement method The ISOMETER IR425 uses the AMP measuring principle. Standards The ISOMETER of the IR425 complies with the requirements of the device standards: DIN EN 61557-8 (VDE 0413-8), IEC 61557-8, ASTM F 1669M-96 (2007). 2 TDB103005en/05.2013

Operating elements 1 2 3 Wiring diagram 1 4 6 3 2 7 3 5 6 7 1 - LED power ON, (flashes in case of interruption of the connecting leads E/KE or L1/L2). 2 - Alarm LED AL1, lights when the value falls below the set response value Alarm 1 and flashes in case of interruption of the connecting leads E/KE or L1/L2. 3 - Alarm LED AL2, lights when the value falls below the set response value Alarm 2 and flashes in case of interruption of the connecting leads E/KE or L1/L2. 4 - LC display 5 - Test button T : to call up the self test. Arrow up button: parameter change, to move up in the menu 6 - Reset button R : to delete stored insulation fault alarms Arrow down button: parameter change, to move down in the menu 7 - Menu button MENU : to call up the menu system. Enter button: Confirms parameter changes 1 - Supply voltage U S (see ordering details) via fuse 2 - Separate connection of E, KE to PE 3 - Connection to the IT system to be monitored: AC: connect terminals L1, L2 to conductor L1, L2. 4 - Alarm relay K1 : Alarm 1 5 - Alarm relay K2 : Alarm 2 6 - Combined test and reset button T/R : short-time pressing (< 1.5 s) = RESET, long-time pressing (> 1.5 s) = TEST 7 - Line protection by a fuse in accordance with IEC 60364-4-43 (6 A fuse recommended). In case of supply (A1/A2) from an IT system, both lines have to be protected by a fuse. 4 5 TDB103005en/05.2013 3

Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated insulation voltage 250 V Rated impulse voltage/pollution degree 2.5 kv/3 Protective separation (reinforced insulation) between (A1, A2) - (L1, L2, E, KE, T/R) - (11, 12, 14) - (21, 22, 24) Voltage test acc. to IEC 61010-1 2.21 kv Supply voltage Supply voltage U S Power consumption IT system being monitored Nominal system voltage U n Nominal frequency f n Response values Response value R an1 (Alarm 1) 1 200 kω Response value R an2 (Alarm 2) Preset mode see ordering information 3 VA AC/DC 0 300 V DC 15 460 Hz 1 200 kω U n 72 V R an1 (Alarm 1) = 20 kω/r an2 (Alarm 2) = 10 kω U n > 72 V Ran1 (Alarm 1) = 46 kω/ran2 (Alarm 2) = 23 kω Relative uncertainty 1 5 kω/5 200 kω ± 0.5 kω/± 15 % Hysteresis 25 % Time response Response time t an at RF = 0.5 x Ran and Ce = 1 μf Start-up delay (start time) t Response delay t on 2 s 0 10 s (0 s)* 0 99 s (0 s)* Measuring circuit Measuring voltage U m ± 12 V Measuring current I m (at RF = 0 Ω) 200 µa Internal DC resistance R i 62 kω Impedance Z i at 50 Hz 60 kω Permissible system leakage capacitance 20 μf Displays, memory Display range, measured value 1 kω 1 MΩ Operating uncertainty 1 5 kω/5 kω 1 MΩ ± 0.5 kω/± 15 % Password off/0 999 (off)* Fault memory, alarm relay on/off* Outputs Cable length test and reset button 10 m Switching elements Number of switching elements 2 x 1 changeover contact Operating principle NC/N/O operation (N/O operation)* Electrical endurance, number of cycles 10000 Contact data acc. to IEC 60947-5-1 Utilisation category AC-13 AC-14 DC-12 DC-12 DC-12 Rated operational voltage 230 V 230 V 220 V 110 V 24 V Rated operational current 5 A 3 A 0.1 A 0.2 A 1 A Minimum contact rating 1 ma at AC/DC 10 V Environment/EMC EMC IEC 61326-2-4 Operating temperature -25 +55 C Climatic class acc. to IEC 60721 Stationary use (IEC 60721-3-3) 3K5 (except condensation and formation of ice) Transport (IEC 60721-3-2) 2K3 (except condensation and formation of ice) Long-time storage (IEC 60721-3-1) 1K4 (except condensation and formation of ice) Classification of mechanical conditions IEC 60721 Stationary use (IEC 60721-3-3) 3M4 Transport (IEC 60721-3-2) 2M2 Long-time storage (IEC 60721-3-1) 1M3 Connection Connection type Connection properties rigid Flexible without ferrule Flexible with ferrule Stripping length Opening force Test opening, diameter push-wire terminal 0.2 2.5 mm² (AWG 24 14) 0.2 2.5 mm² (AWG 24 14) 0.2 1.5 mm² (AWG 24 16) 10 mm 50 N 2.1 mm Other Operating mode continuous operation Mounting any position Degree of protection, internal components (DIN EN 60529) IP30 Degree of protection, terminals (DIN EN 60529) IP20 Enclosure material polycarbonate Screw mounting 2 x M4 with mounting clip DIN rail mounting acc. to IEC 60715 Operating manual TBP103005 Weight 150 g ( )* = factory setting 4 TDB103005en/05.2013

Ordering information Supply voltage 1) U S DC AC Type Art. No. 9.6 94 V 16 72 V, 15 460 Hz IR425-D4-1 B 7103 6403 70 300 V 70 300 V, 15 460 Hz IR425-D4-2 B 7103 6402 Device version with screw terminals on request. 1) Absolute values Accessories Dimension diagram XM420 Type designation Mounting clip for screw mounting (1 piece per device) Art. No. B 9806 0008 Dimensions in mm Open the front plate cover in direction of arrow! Screw mounting Note: The upper mounting clip must be ordered separately (see ordering information). TDB103005en/05.2013 5

Subject to change! TDB103005en / 05.2013 / Schw / Bender GmbH & Co. KG, Germany Bender GmbH & Co. KG P.O. Box 1161 35301 Grünberg Germany Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-0 Fax: +49 6401 807-259 E-Mail: info@bender-de.com www.bender-de.com BENDER Group