Evolve 951 & Product specification pages

Similar documents
Installation guide. Evolve 950. Models: RHFE950ETRN/RHFE950ETRL

INSTALLATION MANUAL Power Flued Flamefire Space Heater Co-axial Flue System

Installation guide. Evolve. Models: RHFE952ETRN / RHFE952ETRL RHFE1252ETRN / RHFE1252ETRL

Installation guide. Evolve RHFE951ETRN/RHFE951ETRL RHFE1250ETRN/RHFE1250ETRL

Installation guide Compact 2

Energysaver Space Heater Co-Axial Flue System Installation Manual

Important: Appliance must be installed with a Rinnai approved flue system.

OPERATION & INSTALLATION MANUAL Power Flued Flamefire Gas Space Heaters RHFE-951ETR & RHFE-1250ETR

Product Catalogue 10YEAR. Fitzroy Profile and Canterbury Classic Series 2015 WAR RAN T Y YEAR

Energysaver Space Heater Co-Axial Flue System Installation Manual

Energysaver & Flued Space Heaters

IS 900 Insert - Charcoal THE WORLD S MOST EFFICIENT GAS LOG SPACE HEATERS WITH THE HIGHEST ENERGY STAR RATING!

REFERENCE GUIDE. Heating. Experience Our Innovation

Energysavers. Appliance must be installed with a Rinnai supplied flue system. For flueing installation details refer to separate instructions.

Clear Installation guide

Flueing Installation Manual

Studio 2. Balanced Flue with Thermostatic Remote Control. Installation Instructions. For use in AU (Australia). IMPORTANT

Fyn Installation guide

Installation Manual EF5000 NZ

Operation guide Evolve 950

City Series CV40E Gas Fireplace

Flue Installation Manual

Flueing Installation Manual For Rinnai Flamefire Heaters

Operation & Installation Manual

Installation Manual EF5000 AUS & NZ

Solution Installation guide

Studio 3 Steel 2, Glass Fronted with Log-effect fuel bed and Vermiculite lining STUDIO GAS FIRES

Duet XL /0929. Installation guide

SLIMFIRE 25 FLAME FIRE. Customer Operation & Installation Manual

Gas Fireplaces FEATURING

gas log fires freestanding & inbuilts

Rinnai 650 / 750 GAS FIRE Operation / Installation Manual

P P Gas Fireplace. P See Thru

Vaska Logburner. voorbeeld Installation guide

Eastside Installation Guidelines and Operating Instructions January 2018

Model 31 and 33 DVI Fi rest y l es for Life

GREENFIRE GAS FIREPLACES

Gas Fireplaces FEATURING

Fyn Installation guide

City Series CB40E Gas Fireplace

gas & wood fire collection

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Energysaver Space Heaters Models: RHFE-309FT & RHFE-559FT Operation and Installation Manual

gas log fires freestanding & inbuilts

Installation Manual. ST900 Direct Vent Gas Fireplace. Important: NZ / AUS EDITION

REGISTRATION EXAMINATION, JUNE 2012 LICENSED GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Duet Premium M Duet Premium M ENG

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

Relaxed Premium M Relaxed Premium M ENG

Twin Wall Installation Instructions And Maintenance Guide

Respect OC Installation manual

gas log fires freestanding & inbuilts

SERVICE MANUAL Sapphire - RIB2312 GAS LOG FLAME FIRE

Inset - IB850, IB1100 Fascia Installation Manual NEW ZEALAND EDITION

USER S GUIDE FOR PASTA COOKER SERIALS

ULTIMA II. Flued Space Heater Operation / Installation Manual. MODEL REH-311FT(B) - Inbuilt MODEL REH-311FT(C) - Console

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS

laces irep as F t G ian ad rary, R o p tem n o C SERIES 4 H fireplaces.com

Gas Inserts FEATURING

INSTALLATION & OPERATING MANUAL

STUDIO Conventional Flue

Model 31 and 33 DVI Gas Fireplace Inserts

LUNA 850 V GOLD GAS INSTRUCTION FOR INSTALLATION AND USE. Passion for fire

Duet Premium L Duet Premium L ENG

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS

USER S GUIDE FOR DEEP FRYER

VASKA C11. gas -fireplace installation guide

H1200/DS H1400 H1600/DS H1600XXL/DS H1200VLG/D H12003V epi950


Fundamentals of a gas fire New Zealand. August 2017

Gas Flare & Rail Burners Gas Flare & Rail Burners Installation Instructions

IB1100, IB850, IB600 (Log Fire / Coal Fire) Installation Manual NEW ZEALAND EDITION

616 Gas Fireplace Insert. Shown with Shadow Box face/panel, Black Painted fireback and Driftwood Log Set.

GREENFIRE GAS FIREPLACES

Rinnai. Rinnai GAS SPACE HEATERS. Convector 417 Unflued Room Heater CUSTOMER S OPERATING INFORMATION AND INSTALLATION INSTRUCTIONS

430 GSR2 Gas Fireplace Insert

CONTEMPORARY GAS FIREPLACES. CONTEMPORARY GAS FIREPLACES. woo

PORTABLE GAS HEATING PORTABLES

^ STUV 21: MODEL SPECIFICATIONS

Intelligent Simplicity

SAPPHIRE GAS LOG FLAME FIRE Operation / Installation Manual

Europa 7 Europa 7 VL Multivision 8000 Series Super 9 Visio 8 Plus

LANDSCAPE BALANCED FLUE SPACE HEATER

LANDSCAPE BALANCED FLUE SPACE HEATER

Effective January 2013 INSTALLATION & OPERATING INSTRUCTIONS. Model: IS900 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

Installation Manual Installation and Appliance Setup

Manual. PG33 Gas Inbuilt. Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. Models: PG33-NG PG33-LPG

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

Gas Inserts & Freestanding FEATURING

Bosch Product Reference Guide. bosch-climate.co.nz

Incident Summary #II (#8165) (FINAL)

Direct Vent Gas Inserts & Freestanding FEATURING

31 and 33 DVI Gas Fireplace Inserts

for architects & designers

PelletVent Multi-fuel venting system. UL 641.

Panorama PG33 Gas Inbuilt

Debonaire VIRAGE LH

Riva2 530/670. Inset Convector Fire - Balanced Flue. With Thermostatic Remote Control. Instructions for Use, Installation & Servicing

Transcription:

951 & 1250 Product specification pages

SUPPORTING ASTHMA CARE Evolve Specification Evolve 951 Evolve 1250 Inbuilt power flued convection fan heater with electronic temperature control, timers, and remote. Different burn media options are available. Specification summary Input = 10-34 MJ/h Output 951 = 2.4-8.1 kw* Output 1250 = 2.4-8.4 kw* Efficiency = 86% (on high) Energy star = up to 5.7 stars* Heating area = 82-125 m 2 ** Gas type = NG or ULPG * Will vary according to gas type and flue configuration ** Will vary depending on geographical location in NZ Suitability Ideal for living rooms and open plan areas. Versatile power flue system makes for easy installation in almost any living space, including bedrooms. The Evolve is best suited for a new build installation into a false (mock) chimney. Room size consideration The Evolve is not suitable for smaller rooms. This is due to the efficiency of the appliance. Smaller rooms will heat up quickly and once the set temperature has been reached the flame picture will reduce significantly (and in some cases reduce to pilot only). This is not ideal if customers want a full flame picture to be visible for the majority of time that the fire is on. Burn media Choice of river stones or silky oak log set. Data plate Inside the appliance, upper right hand side. Gas connection ½ BSP, the gas supply terminates inside the heater lower left hand side of the appliance. Ignition Continuous spark electronic ignition. Noise level: 37-45 db(a) Power flue Inner 50 mm, outer 70-80 mm. Appliance must be installed with a Rinnai flue system. Power consumption and electrical supply High = 90 W Standby = <8W Comes with a 1.5 m power cord and 3-pin plug. Power cord passes through a slot in the back right hand corner of the appliance. Safety devices Flame failure sensing system, pressure relief, overheat safety switch, air temperature sensor, thermal fuse, overcurrent fuse, and spark detector. Temperature control Thermostat control. Temperature control range 16-26 C. Weights Evolve 951: 75 kg Evolve 1250: 100 kg Convection fan 3-speed fan. Heat is distributed from the top of the appliance. S Thermostat controlled Fan Preheat function Timer Remote control Electronic ignition Air filter Child lock Overheat device SENSITIVE CHOICE Evolve 951 & 1250 specification guide pages 01-16 (supplementary pages) 2 of 11

Dimensions (mm) Evolve 951 960 1020 25 560 430 420 620 305 700 570 162 500 10 65 Evolve 1250 1255 1320 25 560 580 570 1000 162 10 65 620 305 570 500 ± 25 Evolve 951 & 1250 specification guide pages 01-16 (supplementary pages) 3 of 11

Framing dimensions The main points governing location are flueing and warm air distribution. H W D Framing dimensions 951 1250 W-width 965-980 mm 1265-1280 mm H-height 570-580 mm 570-580 mm D-depth 570 mm min. 570 mm min. The Rinnai Evolve has an integrated zero clearance box that isolates the appliance from combustible materials. This means it can be installed directly into a decorative fireplace constructed from materials such as wood or plaster. The unit must be positioned within the enclosure on a flat level surface that allows free movement of the appliance. The joists used to support the appliance off the ground must be capable of supporting a minimum of 1.5 times the weight of the appliance. Evolve 951 & 1250 specification guide pages 01-16 (supplementary pages) 4 of 11

Clearances The clearances, measured from the edge of the glass, are the minimum clearances unless otherwise stated. While the heater is operating The appliance must not be installed where curtains or other combustible materials could come into contact with the heater. The 1000 mm clearance above is the clearance to the ceiling. 1000 400 400 1000 400 Note: The 400 mm side clearance includes side walls. Mantels and surrounds Combustible mantels and surrounds require clearance from the unit to minimise fire danger. Mantels and surrounds, made of combustible materials such as wood, are allowed providing they are outside the minimum clearances shown. A B A B C Mantel needs to be a min. of 400 mm away from the edge of the glass. Maximum mantel depth at 400 mm (A) is 250 mm. Surround needs to be a minimum of 400 mm away from the edge of the glass. For every 50 mm of added mantel depth there must be an additional 100 mm of clearance from the edge of the glass. C For example: Mantel depth 300 mm 500 mm 350 mm 600 mm 400 mm 700 mm A: clearance required Evolve 951 & 1250 specification guide pages 01-16 (supplementary pages) 5 of 11

Burn media, frames, and accessories Silky oak log set 951 code: R2781 (8 log pieces) 1250 code: R2783 (10 log pieces) Designed to look like split logs. River stones 951 code: R2780 (30 stones) 1250 code: R2782 (40 stones) A mix of white and grey ceramic stones. Black on black frame 951 code: R2772 1250 code: R2775 Black powder coated metal inner and outer frame. Stainless steel on black frame 951 code: R2773 1250 code: Not available for this model. Stainless steel inner frame, and black powder coated metal outer frame. 1250 black reflector panel kit 951 code: Not available for this model 1250 code: R2787 Black enamel reflector panels. Enhances the flame picture by producing a mirror image of the flames in the side panels. Mesh guard (black) 951 code: R2778 1250 code: R2788 Designed to protect against touching the hot surface of the glass. Sits flush with the inner frame, which holds it in place. Evolve 951 & 1250 specification guide pages 01-16 (supplementary pages) 6 of 11

Flueing options The below options detail the most common types of flue installations. If you have an installation that varies from those below, please contact Rinnai. Direct and direct extended flueing Direct through-the-wall flueing for walls up to 385 mm thick. Flue can be extended if the wall thickness is greater than 385 mm by using the ASPDFK flue kit and additional lengths of ESPIPE900. Sideways flueing The sideways flue installation can run along the left or right hand side of an internal wall behind the heater. When considering the location of the fire ensure the flue path is free from obstructions such as studs, noggins, wiring, joists etc. Down-and-out flueing The down-and-out flue option allows for the adaption flue kit to face downwards and for the flue to run vertically through a hole in the floor, and then terminate horizontally outside (must be 300 mm above ground). Through-wall vertical flueing For the small number of instances where the appliance cannot be directly flued or flued via an internal wall. In some cases a large portion of the flue may be visible from the outside. Direct - Direct flue (ASPDFK) Direct extended - Direct flue (ASPDFK) - Adaption flue (EVOKIT03) - Wall terminal (ESWTERM) - Adaption flue (EVOKIT03) - 45 bends (ESBEND) - Wall terminal (ESWTERM) - Direct flue (ASPDFK) - 45 bends (ESBEND) - Condensate trap (ESCONDK) - Roof cowl (ESROOFCOWL) C A B In-wall vertical flueing The vertical in-wall flue installation is installed against an internal wall within a false fireplace or other suitable cavity, and is run vertically upwards to a vertical or horizontal termination point. A: Direct - Adaption flue (EVOKIT03) - Roof cowl (ESROOFCOWL) B: Offset - Adaption flue (EVOKIT03) - 45 bends (ESBEND) - Roof cowl (ESROOFCOWL) C: Horizontal termination - Adaption flue (EVOKIT03) - 45 bends (ESBEND) - Wall terminal (ESWTERM) Maximum flue length - 8.5 m Maximum number of bends - three One 90 bend = 1 m For every 90 bend the overall length must be reduced by 1 m. For example, if an installation has three 90 bends, the maximum flue length can be 5.5 m. The EVOKIT03 is counted as one 90 bend. * Installer to advise quantity required Evolve 951 & 1250 specification guide pages 01-16 (supplementary pages) 7 of 11

Flue components Evolve adaption flue kit EVOKIT03 Elbow section of this component (circled) requires a 25 mm clearance from combustibles, the rest is zero clearance. Kit includes; flue transition (rotates), condensate trap, wall strap, drain tube (750 mm), silicone grease, and flue slide stopper (4822). 65 mm 115 mm 330 mm Coaxial flue pipe 900 mm 975 mm ESPIPE900 Extension pipe used to construct horizontal, vertical, and downwards flueing. Can be cut to size. Inner is aluminium, and outer is white PVC plastic. Comes with one wall bracket, o-ring (4350), and spacer (4351). Ø 50 mm 35 mm Female end (do not cut) Vertical terminal 900 mm 165 mm ESROOFCOWL Roof cowl and connecting pipe for termination of a vertical flue can be cut to size. Galvanised steel, powder coated black. Ø 195 Ø 75-80 mm Male end (can cut), protrudes approx. 25 mm from bottom of pipe Ø 50 Ø 75 Direct flue kit ASPDFK (aluminium) Suitable for walls up to 385 mm (can be cut to length). Can also be used in combination with ESPIPE900 for longer flueing. Flue terminal section is reusable when making flue longer. 45 flue bends (x2) ESBEND Two 45 bends used to facilitate between horizontal, vertical, and downwards flueing. Two spacers are included. Can be used separately, or together as one 90 bend. Wall terminal kit ESWTERM Used to terminate the ESPIPE900 in horizontal flue installations when used in conjunction with EVOKIT03. Contains: External wall plate (black PVC) Flue terminal (aluminium) 50 mm 540 mm 43 mm 140 mm Ø 75 mm Evolve 951 & 1250 specification guide pages 01-16 (supplementary pages) 8 of 11

Wall plate Steel flue guard (warm white) Condensate trap ESCONDK ESPLATE R1370 Used if an extra wall cover is required to tidy any installation through the wall, ceiling, or floor. Protection against hot flue gases when the termination is low to the ground. Colour - warm white. Supplied with a 750 mm drain tube (not pictured). N.B: Currently white, but changing to black. ONLY ordered as a separate item if doing through-wall vertical flueing, refer p. 15. 120 mm Ø 80 mm 45 bends joined to other flue components 120 mm Photo showing what the wall terminal of the ASPDFK looks like coming out of a wall 220 x 220 mm Ø 146 mm Ø 75 mm Photo of the ASPDFK kit components Steel flue guard Vertical terminal Evolve 951 & 1250 specification guide pages 01-16 (supplementary pages) 9 of 11

Ordering guide 1. Select gas type (engine) Evolve 951 Evolve 1250 Evolve NG engine RHFE951ETRN RHFE1250ETRN Evolve LPG engine RHFE951ETRL RHFE1250ETRL Supplied with the engine is the remote control and batteries, remote control mounting bracket, screw pack, cable tie, frame mounting screws, and granule packs (two for the 951, three for the 1250). 2. Select frame option Stainless steel on black is only available for the Evolve 951. 3. Select burn media Black on black R2772 R2775 Stainless steel on black R2773 - Silky oak log set R2781 R2783 River stones R2780 R2782 Burn media sets cannot be interchanged between the 951 and 1250. The 1250 log set has an extra two logs (10 in total), and the 1250 stone set contains an extra 10 stones (40 in total). 4. Select flue components Direct flue kit Evolve adaption flue kit Vertical terminal (roof cowl) Flue pipe 900 mm Wall terminal kit ASPDFK EVOKIT03 ESROOFCOWL ESPIPE900 ESWTERM 45 flue bends (two in a kit) ESBEND Wall plate ESPLATE Steel flue guard Condensate trap R1370 ESCONDK The condensate trap is included with the EVOKIT03. It only needs to be ordered separately if you are doing through-wall vertical flueing (not common). Evolve 951 & 1250 specification guide pages 01-16 (supplementary pages) 10 of 11

5. Select optional accessories Evolve 951 Evolve 1250 Black mesh guard R2778 R2788 1250 black reflector panel kit - R2787 Ideally the mesh guard and reflector panel kit should be purchased at the same time as the Evolve unit as a gasfitter is required to do the installation. Evolve 951 & 1250 specification guide pages 01-16 (supplementary pages) 11 of 11