GreenPark. GreenJet Throw Performance

Similar documents
GreenJet Transfer Fans

Plenum Fans. Model HPA. Direct Drive

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Electric Duct Heaters. IDHB & IDHC Series

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

High Performance Vane Axial Fans

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

technical specification smoke venting systems

Underground carpark ventilation

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

Tunnel Axial Flow Fan

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

SMOKE CONTROL - NEW DIRECTIONS

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Direct Gas-Fired Make-Up Air

Energy Recovery Ventilators

Better Air Dispersion for. Underfloor. Plenums

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Indirect Gas-Fired Make-Up Air

The Heating System and Ventilation and Combustion Air

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating

Modular Supply Make-Up Air Unit

AXIAL & JET FANS FOR TUNNEL VENTILATION

HVAC OUTDOOR AIR VENTILATION STANDARD. ASHRAE Standard ASHRAE Standard

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

VESDA ASPIRATING SMOKE DETECTION INDUSTRY GUIDE SUBSTATIONS

ASHRAE JOURNAL ON REHEAT

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 25- INTEGRATED AUTOMATION DESIGN STANDARDS SECTION INTEGRATED CONTROL OF FACILITY LAB FUME HOODS

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Understanding Fan System Effects

Tunnel Systems. Design & Supply Metro Axial Fans. Tunnel Axial Fans. Jet Fans.Fans for Escape Tunnel System Components. Engineering Support

Fan Selection. and Energy Savings

Equipment guide for local exhaust ventilation (LEV)

Life Safety Dampers Selection and Application Manual

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

Smoke Management in High-Rise Structures

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Emergency Ventilation System Design - Preliminary Report Shishir Gupta

Modular Active. Chilled. Beams

Displacement Ventilation

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

automatic FiReFighTing SYSTeMS in PainT booths

NOVENCO CAR PARK THRUST VENTILATION SYSTEM DESCRIPTION. Pure competence in air.

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Colt ventilation systems for car parks, loading bays and service areas

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

Home Performance Energy Audit Report

Residential and Light Commercial Ductless Systems Catalog

IAQ: Re-tuning Commercial Buildings

Mixing Technologies Solutions for Flue Gas Desulfurization

Användning tak för att minska risken för översvämning orsakade av skyfall

SECTION AIR DUCT ACCESSORIES

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

Fan System for Drop Ceilings

Myth & Reality of Basement Ventilation

Home Performance Energy Audit Report

Preparing the Next Generation of Building Technicians

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Discover Innovative Comfort

Ventilation for New Low-Rise Residential Buildings July 20, 2015

2012 International Mechanical Code Significant Changes. About the Significant Changes

Chapter 17, Initiating Devices

Flexible and efficient: Close Climate Control for IT equipment

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Exhaust Makeup Air System What goes out, must come in

Use of Dispersion Modeling Software In Ammonia Refrigeration Facility Design. By: Martin L. Timm, PE Corporate Process Safety Manager

DACC Health Sciences Building Air Handler Assessment/Study

Emergency Extract Ventilation

SAFEGUARD YOUR HOME WITH QUELL

EHH SERIES DRAW THROUGH FAN COILS CFM

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

ARCTIC EVAPORATIVE COOLING. Direct Evaporative Coolers Indirect Evaporative Coolers Dew Point Evaporative Coolers


Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Linear Floor Heaters

Home Performance Energy Audit Report

HVAC Controls Upgrades: Requirement Details ( )

Melrose Fire Department

How to ensure Thermal Comfort in buildings with CFD

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

MD and Its Impact on Lab Facilities

ESPAIR E AIRTM ESPA ESPAIRTM. Kitchen Exhaust Air Treatment System KET Series.

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

MODEL CDB8 INSTALLATION INSTRUCTIONS

For information on any of these products, please contact your heating and air conditioning contractor or feel free to write or call us.

Underfloor Air Distribution:

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Ingersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw)

MiniCore Ventilator (500, 1000) Series Engineering Guide

COMPLEX COMMISSIONING AND QUANTITATIVE TESTING GOTTHARD BASE TUNNEL VENTILATION SYSTEM

Alfa Laval Tank Cleaning. Getting the most out of tank cleaning with Gamajet and Toftejorg devices

DESCRIPTION OF TECHNOLOGY

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

Transcription:

GreenPark GreenJet Throw Performance February 2017

GreenPark Page HeaderSystem GreenPark Overview As cars are parked within an underground parking structure, carbon monoxide (CO) and other noxious fumes are emitted into the atmosphere. There is a need for an efficient ventilation system that can remove these toxins, circulate fresh air into the car park, and assist firefighters in the case of a fire emergency. There are two options for this task, ducted or What is GreenPark? ductless ventilation. While ducted ventilation has been the standard for many years, innovation in the field of ventilation has shifted the conventional ventilation system towards ductless designs. Ductless designs use jet fans to dilute and remove contaminants and control the smoke. These systems provide greater control at a fraction of the cost of traditional ducted systems. The solution is Greenheck s GreenPark! GreenPark is a system which consists of both services and components. These combine to provide ventilation during normal operation of the car park, as well as removing the smoke during emergency situations. GreenPark services include sensor placement, Computational Fluid Dynamics (CFD) analysis, and control sequencing. GreenPark components include supply and exhaust fans, GreenJet (GJ) fans, Life Safety and Volume Control dampers, and sensors. GreenPark Advantages Simplified Design: Eliminates the need to perform costly duct design. Lower Construction Cost: GreenJet fans have less height than ducted systems, resulting in less excavation and lower overall construction cost. Lower Installation Cost: A typical GreenPark system results in less installation time overall. Improved Operational Costs: Eliminating the ducts reduces the static pressure required and allows the GreenJet fans to run with less power. Additionally, the sensors allow running the system only when the demand requires. Reduced Maintenance: In addition to eliminating duct cleaning, GreenJet fans are more accessible for maintenance than traditional systems. Enhanced Safety: GreenJet fans are more efficient at removing noxious fumes and clearing smoke, resulting in a safer environment with the added benefit of minimizing potential damage caused to the building. Design Partner GreenPark is a ductless car park offering that combines products and services to provide reliable, energy efficient ventilation along with emergency smoke exhaust. Greenheck knows that every enclosed parking structure has different requirements. This is due to varying geometries, different building types, or conflicting regulatory agencies. That is why GreenPark is a fully configurable solution providing you the highest quality, most cost-effective solution for your region. Greenheck s dedicated engineers will work with you from the beginning stages of building design and assist with decisions such as supply and exhaust shaft locations, fire zoning, and fan placement. As the design continues, the GreenPark solution can include control sequencing, switching diagrams, and even provide commissioning. The GreenPark team is ready to assist in order to provide the system you need! Contact your local sales representative for details. 2

GreenPark System Understanding Throw Diagrams The following throw diagrams were created in a free field environment, and can be used to help guide the initial placement of GreenJet fans. GreenJet fans can cover 10-15 m 2 /N of thrust, which is a basic approach in determining the total coverage area during initial GreenJet placement. Thus, if a parking garage is 5,000 m 2, and the GJ-AU315P GreenJet fan with 25N of thrust is being used, then each GreenJet fan can cover approximately 250 m 2 to 375 m 2 of area. Therefore, 13-20 jet fans are required. Once the number of GreenJet fans are determined, the initial placement can be completed by placing them in locations which generally guide the air from the fresh air supply to the area of exhaust. When moving the air in a linear direction, the fans can be spaced at the approximated throw termination point, or typical fan spacing point. A Computational Fluid Dynamics (CFD) report should always be completed in order to confirm that the correct number of GreenJet fans has been used and that they are placed in the optimal locations. GJ-AU315E Volumetric Flow Rate - 4200 CMH (2472 CFM) Typical Fan Spacing Line Mounted height from ceiling - 220 mm Velocity zones determined by contour lines 3

GJ-AU310P Volumetric Flow Rate - 5450 CMH (3208 CFM) Mounted height from ceiling - 206 mm Volumetric Flow Rate - 4500 CMH (2649 CFM) Mounted height from ceiling - 206 mm 4

GJ-AU310E Volumetric Flow Rate - 3900 CMH (2295 CFM) Mounted height from ceiling - 206 mm Volumetric Flow Rate - 3200 CMH (1883 CFM) Mounted height from ceiling - 206 mm 5

GJ-AU315P Volumetric Flow Rate - 4639 CMH (2730 CFM) Mounted height from ceiling - 220 mm Volumetric Flow Rate - 4582 CMH (2697 CFM) Mounted height from ceiling - 220 mm 6

GJ-AU315E Volumetric Flow Rate - 4204 CMH (2474 CFM) Mounted height from ceiling - 220 mm Volumetric Flow Rate - 4200 CMH (2472 CFM) Mounted height from ceiling - 220 mm 7

GJ-AU355P Volumetric Flow Rate - 8215 CMH (4835 CFM) Mounted height from ceiling - 238 mm Volumetric Flow Rate - 7715 CMH (4541 CFM) Mounted height from ceiling - 238 mm 8

GJ-AU355E Volumetric Flow Rate - 7264 CMH (4275 CFM) Mounted height from ceiling - 238 mm Volumetric Flow Rate - 7329 CMH (4314 CFM) Mounted height from ceiling - 238 mm 9

GJ-AU360P Volumetric Flow Rate - 7650 CMH (4503 CFM) Mounted height from ceiling - 233 mm Volumetric Flow Rate - 8000 CMH (4709 CFM) Mounted height from ceiling - 233 mm 10

GJ-AU360E Volumetric Flow Rate - 6800 CMH (4002 CFM) Mounted height from ceiling - 233 mm Volumetric Flow Rate - 6700 CMH (3943 CFM) Mounted height from ceiling - 233 mm 11

GJ-AU400P Volumetric Flow Rate - 10380 CMH (6109 CFM) Mounted height from ceiling - 260 mm Volumetric Flow Rate - 10103 CMH (5946 CFM) Mounted height from ceiling - 260 mm 12

GJ-AU400E Volumetric Flow Rate - 9087 CMH (5348 CFM) Mounted height from ceiling - 260 mm Volumetric Flow Rate - 9161 CMH (5392 CFM) Mounted height from ceiling - 260 mm 13

GJ-AU410P Volumetric Flow Rate - 12050 CMH (7092 CFM) Mounted height from ceiling - 257 mm Volumetric Flow Rate - 9400 CMH (5533 CFM) Mounted height from ceiling - 257 mm 14

GJ-AU410E Volumetric Flow Rate - 11050 CMH (6504 CFM) Mounted height from ceiling - 257 mm Volumetric Flow Rate - 8800 CMH (5179 CFM) Mounted height from ceiling - 257 mm 15

Design and Selection Support Enjoy Greenheck s extraordinary service, before, during and after the sale. Greenheck offers added value to our wide selection of top performing, energyefficient products by providing several unique Greenheck service programs. G reenheck s free Computer Aided Product Selection program (CAPS), rated by many as the best in the industry, helps you conveniently and efficiently select the right products for the challenge at hand. Greenheck has been Green for a long time! Our energy-saving products and ongoing corporate commitment to sustainability can help you qualify for LEED credits. Find out more about these Greenheck services at: www.greenheck.com www.greenheck.com.cn www.greenheck.co.in Building Value in Air Greenheck delivers value to mechanical engineers by helping them solve virtually any air quality challenges their clients face with a comprehensive selection of top quality, innovative airrelated equipment. We offer extra value to contractors by providing easy-to-install, competitively priced, reliable products that arrive on time. And building owners and occupants value the energy efficiency, low maintenance and quiet dependable operation they experience long after the construction project ends. Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Prepared to Support Green Building Efforts Greenheck Kunshan: No. 1188 Pengqing Road, Huaqiao Town, Kunshan, Jiangsu Province, China www.greenheck.com.cn 16 Greenheck India: 541/542, 5th Floor, Tower B, Spaze i Tech Park, Sector-49, Sohna Road, Gurgaon www.greenheck.co.in Greenheck U.S.A.: P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 www.greenheck.com 00.INT.1020 R1 02-2017 Copyright 2017 Greenheck Fan Corp.