Manual Power relay SR853

Similar documents
Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

OPTIBAR DP 7060 Supplementary Instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

VERSAFLOW VORTEX Supplementary instructions

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Survey of electrical equipment installed in hazardous areas on tankers

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Electrical Installations Design, Selection, Erection and Inspection

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

OPTIBAR P 1010/2010 C Supplementary instructions

Manual for QX0201 Push Button

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

manual addendum DELPHI Ex

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Explosion-proof Immersion Heater Type D-8660

OPTIWAVE X500 Supplementary Instructions

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Inductive slot sensor

COMPACT FLAME CONTROLLER CFC 2000

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Operating Manual Distribution box

Translation of the assembly instructions with operating instructions and technical appendix

BKA-EN Fire Damper. Additional operating instructions according to

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Flameproof Manual Call Points

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Operating Instructions

ATM Lighting sp. z o.o

Certification Supplement Manual

COMPACT FLAME CONTROLLER CFC 1000

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Operating Manual MS220KA and MSR220KA

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Certification Supplement Manual

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Certificate of Compliance

Assembly. Host Sub-D Alarm

Technical Data. Dimensions

BSK-RPR Fire Damper. Additional operating instructions according to

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Technical Data. Dimensions

Certificate of Compliance

Technical Data. General specifications. Rated operating distance s n 5 mm

Operating Instructions

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Supplementary Installation and Operating Instructions. Category II2G

INSTRUCTION MANUAL (ATEX / IECEx)

Earth-Rite II PLUS Static Earthing System

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

DICTATOR Hold-Open Systems for Hazardous Areas

Safety instructions VEGAPULS 64

Dual certification! Air handling units for potentially explosive atmospheres

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Manual Isolating Barrier D461R1 (Revision 01)

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Power Supply Display Module PSDM. Installation and Operation Manual

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

INSTRUCTION & SERVICE MANUAL

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

PEPPERL+FUCHS GmbH

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

ATM Lighting sp. z o.o

Rosemount 3490 Series

Exp, pressurized systems

IECEx Certificate of Conformity

IECEx Certificate of Conformity

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Annubar Flowmeter Series

MANUAL Overflow sensor NVF-104/34-PF

Technical Data. Dimensions

Dräger Polytron 5700 IR Detection of flammable gases and vapours

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Explosion Proof Combination Signal db (A) / 5 Joule

4) Intrinsic Safety Certification

IECEx Certificate of Conformity

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Flameproof Manual Call Points Series MCP

Snifter ATEX22 VERSION. User Manual. Distributor

Transcription:

Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1

SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death or the destruction of property. This symbol warns of a possible failure. Failure to observe this caution may result in the total failure of the device or the system or plant to which it is connected. This symbol highlights important information. Protective grounding Safety Measures: to read and to comply Warning! Extreme caution is advised when handling this device. High electrical discharge is possible and can be fatal. Work on electrical installations and apparatus in operation is generally forbidden in hazardous locations, with the exception of intrinsically safe circuits. In special cases work can be done on non-intrinsically safe circuits, on the condition that during the duration of such work no explosive atmosphere exists. Only explosion protected certified measuring instruments may be used to ensure that the apparatus is voltage-free. Grounding and shortcircuiting may only be carried out, if there is no explosion hazard at the grounding or short circuit connection.

SR853 manual page3 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection types below. This apparatus is only to be used as defined and meets requirements of EN 60079 particularly EN 60079-14 "electrical apparatus for potentiality explosive atmospheres". It can be used in hazardous locations which are hazardous due to gases and vapours according to the explosion group and temperature class as stipulated on the type label. When installing and operating the explosion protected device as well as its periphery, the respective nationally valid regulations and requirements have to be observed. General Instructions Work on electrical installations and apparatus in operation is generally forbidden in hazardous locations, with the exception of intrinsically safe circuits. In special cases, work can be done on non-intrinsically safe circuits, on the condition that during the duration of such work no explosive atmosphere exists. Only explosion protected certified measuring instruments may be used to ensure that the apparatus is voltage-free. Grounding and short circuiting may only be carried out, if there is no explosion hazard at the grounding or short circuit connection. The control unit has to have a back-up fuse as stipulated. The mains connection must have a sufficient short circuit current to ensure safe breaking of the fuse. To achieve an impeccable and safety device operation, please take care for adept transportation, storage and mounting, as well as accurate service and maintenance. Operation on this device should only be implemented by authorised persons and in strict accordance with local safety standards. The electrical data on the type label and if applicable, the "special conditions" of the test certificate TÜV 02 ATEX 1824 is to be observed.! For outdoor installation it is recommended to protect the explosion protected distribution and control system against direct climatic influence, e.g. with a protective roof. The maximum ambient temperature is 140 F (60 C) at T4, if not stipulated otherwise (please note temperature classes of hazardous area and refer to EC- type certificate) Terminal compartment in Increased Safety When closing, it is to be ensured that the gaskets of the terminal compartment remain effective, thus maintaining degree of protection IP 64 to DIN 40 050. Unused entries are to be closed off by impact proof stopping plugs, which are secured against self-loosening and turning. Maintenance Work The gaskets of all parts of the housings have to be checked for damages and replaced, if required. Terminals have to be tightened correctly. Possible changes in colour point to increased temperature. Cable glands, stopping plugs and flanges have to be tested for tightness and secure fitting.

SR853 manual page4 Description The power relay SR853 serves the separation from not intrinsically safe supply lines directly in the ex range in connection with an overpressure casing system. In addition it possesses 4 electrically isolated switching contacts, which open during disconnection of the control voltage. Opening of these contacts is guaranteed by two, from each other independent contact relays switched into row. By high contact rating (420 V, 16 A, 4 KW) also three-phase alternating current feeders can be de-energized. By the double clamps 1/2 and 12/13 on the control port can be cascaded as many as desired power relays. The SR853 is in an option also available as module to the installation in a separately certified Ex e housing, alternatively for the assembly on 35 mm of mounting rail (EN 50022). Conformity with standards The explosion proof power relay SR853 meets requirements of listed standards in the attachment (Declaration of conformity). They were developed, manufactured and tested in accordance with state-of-the-art engineering practice and ISO9001:2008. Transport, Storing, Repairs and Disposal Transport Vibration-free in origin package, do not pitch, handle carefully. Storing Store the device dry, inside of the origin package. Disposal Repairs When the explosion proof multipurpose distribution, switching and control units are eventually disposed of, the national regulations governing the disposal of waste materials in the country concerned must be rigorously observed. Defective parts may only be replaced by the Manufacturer or by personnel specially trained and supervised by the Manufacturer. Only genuine spare parts from the Manufacturer may be fitted.

SR853 manual page5 Mounting Power relay SR853 The power relay SR853 could be used in hazardous area Zone 1 and Zone 21. It could be mounted anywhere in the hazardous area (in The Ex p housing, or outside). The device has 4 drillings on the backside for mounting. Please fulfill the following Standard of Compliance: Local installation standards and the regulative EN 60079-14 or IEC 60079-14. Connection hints. The following items have to be observed. LINE VOLTAGE! Extreme caution is advised when handling this device. High electrical discharge is possible and can be fatal. Take note the regulative EN 60079-14 or IEC 60079-14 and the EC type examination certificate TÜV 02 ATEX 1824 or IECEx TUN 14.0029. Do not exceed terminal safety limits of each terminal. See limits in technical details or declarations of conformity.

SR853 manual page6 Terminals Clamp Characterisation 12,13,14,15 10,11,16,17 N 8,9,18,19 L1 6,7,20,21 L2 4,5,22,23 L3 3,24 N 2,25 Lx 1,26 Block diagram 14 15 16 17 18 19 20 21 22 23 24 25 26 N Lx N L1 L2 L3 N Lx 13 12 11 10 9 8 7 6 5 4 3 2 1

SR853 manual page7 Appendix Technical details Mains [V] 24V AC/DC... 230 V AC AC: 48..62 Hz Ex-protection Ex e q IIC T4 Gb Ex tb IIIC T108 C Device group II 2 G II 2 D EC type certificate TÜV 02 ATEX 1824 IECEx IECEx TUN 14.0029 Assembly within Ex range Ambient temperature Typ SR853.8.x.0: -20 C.. max. 50 C Typ SR853.8.x.1: -20 C.. max. 70 C Relay contacts AC: max. 400V, 16 A, 30A/4s oder 80A/20ms Typ SR853.8.x.0 DC: max. 28V, 16 A 4000 VA Relay contacts AC: max. 400V, 16 A, 30A/4s Typ SR853.8.x.1 DC: max. 28 V, 16 A 4000 VA Max. cable diameter 6 mm² Power consumption ca. 5 W Protection class IP65 (SR853.x.0.x) Dimensions Housing: Module: 120 x122 x 90 mm 85 x 116 x 45 mm Housing material Aluminium, powder coated, RAL 7035 For further data see type examination certificate. Cable diameters Cable type single wire fine wire without end splice fine wire with end splice Max. cable diameter 6 mm² 6 mm² 4 mm²

SR853 manual page8 Dimensions SR853.8.0.x Height: 90 mm Dimensions module SR853.8.2.x Depth 106 mm

SR853 manual page9 Type code Power relay SR 853... Mains:.8 24 DC 230 V AC... Housing: In Ex e- housing....0 without Ex e- housing with 2 screw mountings M6... without Ex e- housing, with mounting rail owner....1.2 Ambient temperature and inrush current: - 20 C.. 50 C / 30A/4s bzw. 80A/20ms... - 20 C.. 70 C / 30A/4s....0.1