End customer overview

Similar documents
Installation and Maintenance Manual CTC GSi 12. Modulating ground source heat pump. Providing sustainable energy solutions worldwide

Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~ Providing sustainable energy solutions worldwide

Providing sustainable energy solutions worldwide. Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~

CTC GSi 12. Installation and Maintenance Manual. Modulating ground source heat pump 400V 3N~ Providing sustainable energy solutions worldwide

User instructions DHP-AT

CTC GSi 12. Installation and Maintenance Manual. Modulating ground source heat pump 230V 1N~/230V 3~ Providing sustainable energy solutions worldwide

Diplomat Inverter/Diplomat Duo Inverter

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

User manual. JASPI COMFORT MONO 8 & 12Kw UK 1x230V. Air/water heat pump LEK

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

User manual NIBE F2026

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

/ Installation and Maintenance Manua. CTC EcoAir. Model 105 I 107 I 110 Polar Edition 107 I 110. Air/Water Heat Pump

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Indoor module NIBE VVM 500

Efficient heating that won t cost the earth

User manual JÄSPI Inverter Nordic 8, 12, 16, 20

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

CTC EcoZenith i350 Indoor module with heat pump control available in two heights

Heat Pumps and Public Swimming Pools, a Perfect Match

User manual DHP-AQ VUGFB102

CTC EcoAir 510M. Installation- and Maintenance Manual. Modulating air/water heat pump 230 V 1N~ Providing sustainable energy solutions worldwide

Technical description. Atec.

SYX660 Commissioning Guide V Page 1 of 55

Daikin Altherma Selection Report

User Guide. itec.

ELECTRIC BOILERS FOR CENTRAL HEATING

User manual NIBE F730

User manual NIBE F1145PC

prestige Control Application Supplement - TriMax

Daikin Altherma Hybrid User Guide

user s manual VUBMG102

prestige Control Application Supplement - TriMax

SEALED THERMAL STORE

User manual NIBE VVM 320

GA01HC-02. Service manual. Room Panel. Programme version 01a. Operating with GH07EA regulator for controlling electrode boilers

1/8. Field settings table. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes - *GSQH10S18AA9W / ThermaliaC12* 4P C

Installation Guide. ECL Comfort 210, application A Table of Contents

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

ComfortSense 7500 Thermostat. User Guide

Installation instructions

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk

Boiler controller S-Tronic Plus

User manual NIBE F1245 UK 1x230V. Ground source heat pump

Modulating clock thermostat

USER GUIDE VOGUE MAX SYSTEM

Product Manual SZ1009

Tranquility Digital Quick Start Guide

SYX66x Commissioning Guide V Page 1 of 61

User manual NIBE F370

ECL Comfort 110, application 116

ComfortSense 7500 Commercial Thermostat. User Guide

Installation- and maintenance. CTC EcoEl. Model 1550 and / CTC EcoEl 1

Installation and servicing instructions

CTC EcoZenith i350 L/H Indoor module with heat pump control available in two heights

Boiler controller Lambdatronic S 3200

Home owner user pack for the Nibe 200P

Product Manual SZ1022/SZ1031/SZ1035/

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

Manual and installation instructions. Function. Operating phase

Samsung EHS Heat Pump Test

prestige Control Application Supplement - ACVMax

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

USER MANUAL. OPTIMA 312 ES960C circuit board

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Field settings table [6.8.2] =... ID66F2. Applicable units *BLQ05CAV3 *DLQ05CAV3 *BLQ07CAV3 *DLQ07CAV3. Notes (*1) *B* (*2) *D* 1/8

Control Application. Supplement - ACVMax

ATC32U03 igate Communicating, Programmable Thermostat

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Tranquility Digital Quick Start Guide

Condensing Boiler RS100 Controller Training Program

2018 thesimple, Inc.

Planning guide. (2010/09) en

CTC EcoComfort. Installation and Maintenance Manual. for the property owner. Providing sustainable energy solutions worldwide

* * Valves, controls + systems. Regtronic RH Installation and operating instructions for the specialised installer

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

danfoss Heating Solutions 5

GREENSOURCE HYDROLIGHT AND HYDROCOMFORT

Heating Zone Control. How to apply RESOL MX controller

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Installer manual NIBE VVM 500

User s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

Operating Instructions

Operating Instructions High-spec Wired Remote Controller

USER MANUAL. Danfoss Heat Pump DHP-R VUIFK102

Daikin ENVi Thermostat installation overview

MAKING MODERN LIVING POSSIBLE. Commissioning. DHP-iQ.

TF Series With SECOPAC LS

User Instructions For TopTronic RS-30

1/8. Field settings table. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P C

ECL Comfort 210 / 296 / 310

1/8. Field settings table [6.8.2] =... ID66F3. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P E

Operating Instructions High-spec Wired Remote Controller

DeltaTherm HC * * Heating controller Manual for the specialised craftsman. Installation Operation Functions and options Troubleshooting

Installer manual NIBE VVM 310

Transcription:

16210568-1 2016-08-23 End customer overview Indoor module with heat pump control 1. Sign the installation checklist. 2. Serial no. behind touchscreen. 3. Bleed radiator system and products, approx. one month after installation + at least once per year. 4. Screw in/close the bleed screw on the automatic bleeder approx. three months after installation. 5. Fit/turn the safety valve, approx. four times per year. 6. Check the system pressure regularly and ask the installer what system pressure your system should have; this will normally be around 1 bar. If the pressure is too low, the system must be refi lled. 7. Regularly clean the dirt fi lter (close off incoming tap water; remove and clean the fi lter)/solenoid fi lter ball valve (close off the fl ow to the heat pump; remove and clean the fi lter). 8. Set the correct heating curve for a comfortable room temperature; check that the thermostat valves on the element or fl oor heating are set up correctly. These may need to be opened. 9. Set the hot water mode according to your requirements. 7. solenoid filter ball valve 7. dirt filter for tap water 4. automatic bleeder 6. manometer 6. filler manifold 2. serial number for registration behind screen which can be tilted 3. & 5. safety valve 8. & 9. touchscreen Read the full instructions in the Installation and Maintenance Manual 1

Touchscreen All product settings are set up via the touchscreen. Set the heat and hot water settings here. Outdoor sensor Measures outdoor temperature; placement should not be in direct sunlight or where the measured outdoor temperature may be misleading. The outdoor sensor provides the product with information on the current need for heat. Touchscreen Low version High version Room sensor Measures indoor temperature and finely adjusts the heating curve so that the product runs more evenly. The room sensor is optional and the product can work using only the heating curve. The room sensor should preferably not be activated until the heating curve has been completely adjusted. The room sensor is fitted at a central point in the house, in the most open position possible. This is the best position for the sensor to record an average temperature for the house. Clean, safe hot water The water in the tank (as in the heat pump and radiators) rises and is layered so that the hottest water surrounds the DHW heat exchanger where the tap water flows through quickly, draws energy and flows out to the tap or shower. This provides fresh hot water and minimises the risk of legionella bacteria. Heat pump The heat pump is connected to the product and provides energy obtained from the air or bedrock. See the heat pump manual for information on servicing and checking the heat pump. Remember that the brine fluid must be checked and refilled as needed. Electrical operation DHW heat exchanger Hot water tank Electrical heat The product can also provide both heating and hot water to the building when running on electricity only. With the heat pump connected, the immersion heater works to provide additional heat as needed only. The touchscreen can be used to set whether the immersion heater goes in and with how much power. 2

Options with 1 * In addition to the basic installation, accessories are required such as: Extra sensor, mixing valve group 2, expansion card etc. Volume tank CTC VT 80 may be required for some houses (see installation manual for more information). Basic installation, 1 heating circuit 1 compatible heat pump in the CTC EcoAir 400 or 500M series 1 heating circuit 1 compatible heat pump in the CTC EcoPart 400 series 3

Navigate on the touchscreen Home The Home button takes you back to the Start menu. + / - Press + to increase value Press - to decrease value Return The Return button takes you back to the previous level. OK The OK button is used to mark and confirm text and options in the menus. Arrow & OK Press up arrow to increase value Press OK to save settings Press down arrow to decrease value Home screen Room temperature heating circuit 1 -Measured by Room sensor 1 Room temperature heating circuit 2 -Measured by Room sensor 2 Tank temperature -Measured by Hot water sensor in the top of the tank. CTC EcoZenit i350 Thursday 09:47 Room temp. Hot water Operation Installer 1 2 22.2 ºC 21.2 ºC 58 ºC -5 ºC Outdoor temperature - Measured by Outdoor sensor See operation data Press part to see detailed information on each Alarm management Green LED status OK Red LED alarm Återställ larm Reset alarm Alarm: Larm: Wrong Fel phase fasföljd order kompressor compressor See troubleshooting chart at the very back of the installation manual. serial number software update Serial number XXXX-XXXX-XXXX The serial number (12 digits) can be found behind the display. This number needs to be given to the installation engineer and CTC support in the event of a fault report. Call your installation engineer in the first instance article group year/week sequential number 4

ngs language ansk Nederlands Čeština esti Polski Slovenščina Def heating circuit 1 ing circuit 1 m sensor 1 Yes Yes Set heating Fine adjustment Increase/decrease heat Measured temp Room sensor Desired Setpoint Coarse adjustment Increase/decrease heat Select: + + Heating circuit Room temp. Heating System 1 Heating circuit 2 (50) 1 2 1 2 Fine adjustment with no room sensor. To allow the temperature to be changed even more, use the coarse adjustment on the right. Night reduction Night reduction -Set a higher or lower temperature at certain times of day. Holiday Holiday -Set higher or lower temperatures on certain days. + Heating circuit Max primary flow ºC 55 Min primary flow ºC Off Heating, mode Auto Heating, mode, ext Heating off, out ºC 18 Heating off, time 120 Inclination ºC 50 Adjustment ºC 0 Night reduction disable ºC -14 Room temp reduced ºC -2 or Primary flow reduced ºC -3 Alarm room temp ºC 5 Smart low price ºC 1 Smart over capacity ºC 2 Max time heating 20 Charge pump % 90 Drying period mode Off Drying period temp ºC 25 If the outdoor If the outdoor temperature is lower temperature is higher than 0 C. than 0 C. Change inclination Change adjustment + Push OK to confirm changes Set hot water DHW Extra hot water On Temperature Normal Change hot tap water temperature Select: Hot Change: Hot + tap water DHW tank + + water tank Stop temp C 55 Start/stop diff upper ºC 5 Max time DHW 20 DHW ºC 50 Charge pump % 90 Smart low price ºC 10 Smart overcapacity 10 Runtime DHW-circ. 4 Time DHW-circ. 15 Timer DHW-circulation Min RPS DHW charging 50 Add heat DHW No 0.0 hours Weekly program The product will start to produce additional hot water. Weekly program - Set weekly interval for extra hot water Control normal mode for hot water production. Economic Small DHW requirement. Normal Normal DHW requirement. Comfort Large DHW requirement. Allow additional heat and immersion heater for safe comfort at all times To ensure hot water comfort in all operating conditions, it may be necessary to allow additional heat. If there is no heat pump or other heat source installed, these settings need to be changed so that the product can function as an electric boiler. Select: Hot Change: + Add heat DHW Yes + + water tank Installer Installer is used by the installer to configure the settings and servicing for your heating system. More settings and tips in the installation and service manual 5

Heat settings The product regulates itself to provide a constant, comfortable temperature throughout the year using the set heating curve. The curve may need to be changed using the touchscreen if the room temperature feels too cold or hot over time. For information on how to do this, see Navigate touchscreen on the previous page. Correction may be required for a few weeks after installation until the system has been matched to the building. For more information, see the Installation and Maintenance Manual, section: The house heating curve. Find the right heating curve The heating curve for the house is determined by two main factors: inclination and adjustment. These can be changed to fit the house s energy needs for heating. The house s heating needs depend on: The size of the house (volume/area) Insulation Window area -> inclination and adjustment increase the more energy is required Thermal conductivity of the radiators - Elements - Floor heating - Number of elements/surface for heat transfer -> inclination and adjustment decrease the faster energy is discharged Change inclination when outdoor temperature < 0 C Change adjustment when outdoor temperature > 0 C water temp. out on the elements 3 1 2 (inclination 50) (inclination 40) inclination adjustment Examples of inclination values for different systems Floor heating only inclination = 35 Low temperature system (well insulated houses) inclination = 40 Normal temperature system (factory setting) inclination = 50 High temperature system (older houses, small radiators, poorly insulated) inclination = 60 Example in image: 1. Inclination 50, Adjustment 0 2. Inclination 40, Adjustment 0 3. Inclination 50, Adjustment 5 outdoor temperature 6

Energy consumption The total energy consumption of the product is linked to: The energy needed by the house, which varies significantly through the year depending on the outdoor temperature (see image on energy consumption, right). DHW consumption. Dec Jan Feb i Remember: Energy consumption is much higher in the winter months than in the summer months Energy consumption increases when DHW consumption is high What is important is the total energy bill for the year. Nov Oct M/J/J/A Sep kwh Apr Mar Energy-saving tips Make sure that the thermostat valves on the house s element are open in most rooms; only adjust downwards in bedrooms, for example. Use the DHW chart for extra DHW to avoid high-temperature operation when it is not needed. Install a room sensor; this provides more even heat and compensates for natural solar radiation or other natural heat sources. Clean any dirt filters regularly; a deterioration in water flow can increase the electricity used by the circulation pump. Make sure the speed of the charge/circulation pump provides the right flow (see the chapter System adjustments in the Installation and Maintenance Manual). 7

Checklist The checklist must always be completed by the installation engineer In the event of a service, this information may be called for. Installation must always be carried out according to the installation and maintenance instructions. Installation must always be carried out in accordance with best professional practice. Following installation, the unit must be inspected and checked for functionality. The points below must be checked off. Pipe installation Product filled, positioned and adjusted in the correct manner according to the instructions. Product positioned so that it can be serviced. Capacity of charge pump (G11) adjusted for correct flow. Open radiator valves and other relevant valves. Tightness test. Bleed the system. Safety valve function test. Waste pipe connected to floor drain. Electrical installation Omnipolar switch If the heat pump is installed: heat pump activated and started Electric power (kw) and fuse, adapted to the property, in heating mode, in hot water mode and backup mode Correct tight wiring Requisite sensors for selected system Outdoor sensor Room sensor (optional) Current sensor Accessories Information for the customer (adapted to current installation) Start-up with customer/installer. Menus/controls for selected system Installation and maintenance manual supplied to the customer Check and filling, heating system Trimming information, heat curve Alarm information Safety valve function test Warranty and insurance Information on procedures for fault registration The above points have been reviewed upon installation Date/Place Signature/DHW installation engineer Tel. no. Customer s signature Signature/Electrician Tel. no. Product Serial number