CERTIFICATE of Product Conformity (QAL1 )

Similar documents
CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

Certificate: _01 / 20 August 2013

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: _03. V-CEM5100 for waste gas velocity. TÜV Rheinland Energy GmbH

Certificate: / 9 February 2011

CERTIFICATE of Product Conformity (QAL1 )

Certificate: / 29 April 2014

Certificate: _01 / 29 April 2014

Certificate: _01 / 22 March 2013

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 22 March 2013

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19July2017. Köln, 17 August2012

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 28 July 2016

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: ENDA-5000 with analysing module CMA-5800 for NOx. S0 2, CO, co2 and 02

Certificate: _02 / 9 September 2014

Certificate: _02 / 22 March 2013

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

Certificate: _01 / 2 February 2015

Certificate: / 9 September 2014

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02

CERTIFICATE of Product Conformity (QAL1 )

_03 / 28 July 2015

CONFIRMATION of Product Conformity (QAL1)

Certificate: / 29 April 2014

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 19 August 2011

CERTIFICATE of Product Conformity (QAL1 )

Certificate: / 29 April / /D1 of 07 July 2006 Addendum 936/ /C of 20 September 2013

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE AR500 Open Path Monitor with ER120

International comparison of validation methods for dust concentration measurement

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

Test reports for the determination of B 10d values for emergency stop switches of families 800F, 800H, 800T and D7 of Rockwell Automation

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

Product data sheet Palas Fidas 200 S

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

continuous emissions monitoring Combustion & Environmental Monitoring

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

PRODUCT CONFORMITY CERTIFICATE

Automation, Software und Informationstechnologie

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

WIO200 Water In Oil measuring instrument

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

PRODUCT CONFORMITY CERTIFICATE

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Dust Alert 75. *shown with optional external keypad and display

FIDAS FINE DUST MONITORING SYSTEMS

The Impact of Marking Requirements. on Design and Performance of Power Converters and Electrical Drives

COMPACT FLAME CONTROLLER CFC 1000

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

COMPACT FLAME CONTROLLER CFC 2000

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

OPTISENS TUR 2000 Technical Datasheet

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

Notified Body No.: 0098

3kW 6kW, QUBE Fiber Lasers

including the locations according to annex

HYGROPHIL H process hygrometer

NO NO 2 NO x SO 2 CO CO 2 O 2

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

A New Standard of Excellence

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

S304 and S305 Dust Emission Monitors. User Manual. Distributor

High-accuracy Multi-sensor IAQ Detector MSD Commercial grade for intelligent& green buildings

COMPACT FLAME CONTROLLER CFC 100

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

DP 300 mobile dew point instrument

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Transcription:

ATÜVRheinland Precisely F}ight. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000053803 Certified AMS: Manufacturer: Test lnstitute: D-R 808 for dust DURAG GmbH Kollaustr.105 Hamburg German TÜV Rheinland Energy GmbH This is to certify that the AMS has been tesl:ed and cerlified according to the standards EN 15267-1 (2009), EN 15267-2 (2009), EN 15267-3 (2007) and EN 14181 (2014) Certification is awarded in respect of the conditions stated in this ceriificate (this certificate contains 6 pages). Suitability Tested EN 15267 QALI Certified F]egular Surveillance www.tuv.com ld 0000053803 Publication in the German Federal Gazette (BAnz.) of 15 March 2017 German Federal Environment Agency Dessau, 25 April 2017 + ß V Dr. Marcel Langner Head of Section 114.1 www.umwelt-tuv.eu tre@umwelt-tuv.eu Tel. + 49 221 806-5200 This certificate will expire on: 14 March 2022 TÜV Rheinland Energy GmbH Cologne, 24 April 2017 / fl u /z< cjppa. Dr. Peter Wilbring TÜV Rheinland Energy GmbH Am Grauen Stein 51105 Köln Test institute accredited to EN ISO/lEC 17025:2005 by DAkks (German Accreditation Body). This accreditation is limited to the accreditation scope defined in the enclosure to the ceriificate D-PL-11120-02-00. qall.de info@qall.de page 1 of 6

Test report: 936/21232768/B dated 12 October 2016 Initial certification: 15 March 2017 Expiry date: 14 March 2022 Publication: BAnz AT 15.03.2017 B6, chapter I no. 2.1 Approved application The tested AMS is suitable for use at combustion plants according to Directive 2010/75/EU, chapter III (13. BImSchV), at waste incineration plants according to Directive 2010/75/EU, chapter IV (17. BImSchV), the 27. BImSchV and other plants requiring official approval. The measured ranges have been selected considering the wide application range of the AMS. The suitability of the AMS for this application was assessed on the basis of a laboratory test and a three-month field test at a waste incineration plant. The AMS is approved for an ambient temperature range of -40 C to +60 C. The notification of suitability of the AMS, performance testing, and the uncertainty calculation have been effected on the basis of the regulations valid at the time of performance testing. As changes in legal regulations are possible, any potential user should ensure that this AMS is suitable for monitoring the limit value relevant to the application. Any potential user should ensure, in consultation with the manufacturer, that this AMS is suitable for the installation at which it will be installed. Basis of the certification This certification is based on: Test report 936/21232768/B dated 12 October 2016 of TÜV Rheinland Energy GmbH Suitability announced by the German Federal Environment Agency (UBA) as the relevant body The ongoing surveillance of the product and the manufacturing process qal1.de info@qal1.de page 2 of 6

Publication in the German Federal Gazette: BAnz AT 15.03.2017 B6, chapter I no. 2.1, Announcement by UBA from 22 February 2017 AMS designation: D-R 808 for dust Manufacturer: DURAG GmbH, Hamburg Field of application: For measurements at plants requiring official approval and plants according to 27 th BImSchV Measuring ranges during the performance test: Component Certification range Unit Dust 0 7.5 * mg/m³ * correspond to 0-500 SL Component Supplementary measurement ranges Unit Dust 0 1,000 0 4,000 0 20,000 SL Software versions: D-R 808: 02.00R0002 D-ISC 100: 01.04R0017 D-ESI 100: 1.1.017 Restrictions: None Notes: 1. The maintenance interval is four weeks. 2. The measuring system is equipped with the control unit D-ISC 100 or with the supply unit D-TB 200 or with the supply unit D-TB 100. 3. The measuring system needs to be supplied with purge air (compressed air) via the D-TB 200 supply unit or via an external source. 4. The universal control unit D-ISC 100 is equipped with a digital interfaces Modbus RTU and Modbus TCP for data transfer in accordance with VDI guideline 4201 part 1 and part 3 (EIA485, serial and TCP/IP, Ethernet). 5. The measuring system D-R 808 is equipped with the digital interface Modbus RTU according to VDI 4201 part 1 and part 3 (EIA485, serial). 6. When the D-R 808 measuring system is combined with the universal D-ISC 100 control unit, the measuring system s Modbus interface cannot be used. In that case, the digital Modbus interface provided by the D-ISC 100 control unit is used. 7. If the measuring system is operated without the universal D-ISC 100 control unit, the D-ESI 100 software installed on a standard PC/notebook/tablet serves to control the measuring system. qal1.de info@qal1.de page 3 of 6

Test report: TÜV Rheinland Energy GmbH, Cologne Report No.: 936/21232768/B dated 12 October 2016 Certified product This certificate applies to automated measurement systems conforming to the following description: The D-R 808 is a dust monitor operating on the basis of the scattered light principle. The D-R 808 uses the principle of forward scattering. Focussed modulated light of a red laser diode beams through the measurement volume. Light scattered as a result of forward scattering is captured with a highly sensitive detector and electronically evaluated. The measured intensity of scattered light is proportional to the dust concentration in the flue gas duct. After a gravimetric calibration the relationship between the scattered light units and the dust concentration can be determined. The D-R 808 is equipped with zero point and span point measurement and determination of soiling for the purpose of functional checks. The measuring system comprises the following components: D-R 808 measurement probe and o Electronic D-TB 100 connection box for voltage supply or o D-TB 200 supply unit with blower purge or o Universal D-ISC 100 control unit. When using the D-TB 100 or the D-TB 200 connection box, the D-R 808 measuring system is controlled via a PC with control software. The universal D-ISC 100 control panel allows operating the measuring system without a PC. When using the D-TB 100 and the D-ISC 100 connection devices, the measuring system needs to be equipped with an external purge air supply, e.g. pressured air with a class 1 specification in accordance with ISO 8573-1:2010. The connection boxes work as connection unit with signal transfer without actually influencing processing of the measured values. The D-TB 200 connection box additionally provides purge air supply. The generation of measured values and all measurement relevant calculations (incl. analogue and digital generation of measured values) take place in the measurement head itself. The measuring system has a digital interface in accordance with VDI 4201 part 1 and 3 (EIA-485, serial and TCP/IP, Ethernet). The measuring system is available with two different lengths of the probe (probe length 400 mm and 800 mm). While the two versions differ in terms of probe length, they are otherwise identical. This particularly applies to the measuring gap and the measured volume. The measuring probe can be adapted in terms of the direction of connectors in relation to the flow and the situation at the waste gas duct. Thus, purge air supply maybe provided horizontally for example or electrical connectors may face downward. In any case, the flow direction determines the position of the measurement volume. During performance testing, the averaging time for the measured value was set to 30 s. In addition to the automatic functions zero point check, span checks and contamination check, it is possible to perform manual linearity tests. This is effected by pluggable opacity filters. As long as there is no excess pressure in the measurement channel, the instrument does not have to be removed from the measurement duct for this. For the filter test, the filter holder is screwed into the cleaning opening opposite the purge air connection. The measurement then uses ND filters which can be inserted into the holder. qal1.de info@qal1.de page 4 of 6

The current software versions are: D-R 808: 02.00R0002 D-ISC 100: 01.04R0017 D-ESI 100: 1.1.017. The current version of the operation manual is 10013349-00-01 dated 18 August 2016. General notes This certificate is based upon the equipment tested. The manufacturer is responsible for ensuring that on-going production complies with the requirements of the EN 15267. The manufacturer is required to maintain an approved quality management system controlling the manufacture of the certified product. Both the product and the quality management systems shall be subject to regular surveillance. If a product of the current production does not conform to the certified product, TÜV Rheinland Energy GmbH must be notified at the address given on page 1. A certification mark with an ID-Number that is specific to the certified product is presented on page 1 of this certificate. This can be applied to the product or used in publicity material for the certified product. This document as well as the certification mark remains property of TÜV Rheinland Energy GmbH. With revocation of the publication the certificate loses its validity. After the expiration of the certificate and on requests of the TÜV Rheinland Energy GmbH this document shall be returned and the certificate mark must not be employed anymore. The relevant version of this certificate and its expiration is also accessible on the internet: qal1.de. Certification of D-R 808 is based on the documents listed below and the regular, continuous monitoring of the Quality Management System of the manufacturer: Initial certification according to EN 15267 Certificate No. 0000053803: 25 April 2017 Expiry date of the certificate: 14 March 2022 Test report: 936/21232768/B dated 12 October 2016 TÜV Rheinland Energy GmbH, Cologne Publication: BAnz AT 15.03.2017 B6, chapter I no. 2.1 Announcement by UBA dated 22 February 2017 qal1.de info@qal1.de page 5 of 6

Calculation of overall uncertainty according to EN 14181 and EN 15267-3 Measuring system Manufacturer DURAG GmbH AMS designation D-R 808 Serial number of units under test 484/485/812/813/814/815 Measuring principle scattered light Test report Test laboratory Date of report 936/21232768/A TÜV Rheinland 2016-10-12 Measured component Dust Certification range 0-7.5 mg/m³ Calculation of the combined standard uncertainty Tested parameter u² Standard deviation from paired measurements under field conditions * u D 0.114 mg/m³ 0.013 (mg/m³)² Lack of fit u lof 0.030 mg/m³ 0.001 (mg/m³)² Zero drift from field test u d,z -0.030 mg/m³ 0.001 (mg/m³)² Span drift from field test u d,s -0.056 mg/m³ 0.003 (mg/m³)² Influence of ambient temperature at span u t 0.030 mg/m³ 0.001 (mg/m³)² Influence of supply voltage u v 0.030 mg/m³ 0.001 (mg/m³)² Uncertainty of reference material at 70% of certification range u rm 0.061 mg/m³ 0.004 (mg/m³)² * The larger value is used : "Repeatability standard deviation at set point" or "Standard deviation from paired measurements under field conditions" å ( ) Combined standard uncertainty (u C ) u c = u max, j 0.15 mg/m³ Total expanded uncertainty U = u c * k = u c * 1.96 0.30 mg/m³ 2 Relative total expanded uncertainty U in % of the ELV 5 mg/m³ 6.0 Requirement of 2010/75/EU U in % of the ELV 5 mg/m³ 30.0 Requirement of EN 15267-3 U in % of the ELV 5 mg/m³ 22.5 qal1.de info@qal1.de page 6 of 6