RED DOT UNITS HEATER ONLY. Heaters PAGE 51

Similar documents
RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

UNITS & KITS. Fast Finder A/C & HEATER UNITS AUXILIARY HEATERS BACKWALL MOUNT BUSES School, Shuttle, and Transit...

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

R-2000 HEADLINER Air Conditioner Unit

Dreison International Inc. TURBO Precleaners. Pow-R-Quik Starters. Marion Fluid Power. HydraMotion. SuperTrapp Industrial Mufflers

Marine Catalog. Marine Catalog. Sure Marine Service, Inc th Ave. N.W. Seattle, WA (800) (206)

Rooftop Systems. Rooftop Systems FARAD...35 HD-1000 A/C...37 HD-1000 HVAC...39 KA KA KA Bergstrom, Inc.

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

Thermal Devices, Inc. Mount Airy, Maryland USA

Industrial Air Heaters

Bergstrom Standard Products

Climate Control Systems for Work Vehicles. Air Conditioning and Heating Solutions from Webasto

UNITS & SYSTEMS. Fast Finder A/C & HEATER UNITS AUXILIARY HEATERS...610, 617 WALL MOUNT BUSES School, Shuttle, and Transit...

LUH HORIZONTAL FAN-FORCED UNIT HEATER

Headliner Systems. Headliner Systems KA-400 SLIMLINE...49 KK-400 SLIMLINE...51 KA-500 HARDHAT...53 KA KA KELVIN A/C...

XVI. APUs. Mobile Climate Control 337

PLATINUM. Commercial Unit Heater Program PLATINUM. Electronic Platinum KB Platinum. Includes It All. Featured Inside: Includes It All.

R-8725/R-8730 Underdash Drop In Evaporator

Portable Vertical Air-Conditioning and Heating Systems

Unit Features & Benefits RQPM/RQRM Series

Air Handler Installation Instructions Water Lines

Explosion-Proof Forced Air Unit Heater - XGB

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

CURTIS/KUBOTA BX-1500, 1800, 2400, 1850, 2350, 25 BX1870, BX2370, BX25D & BX HEATER INSTALLATION (p/n: 9PH20S18)

Explosion-Proof Forced Air Unit Heater - XGB

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

CX1 ProVector Explosion-Proof Heaters

Marine Coolant Heater Catalog

BUSES. SCHOOL, SHUTTLE and TRANSIT. Table of Contents APPLICATIONS - BUSES. BLOWER MOTORS Includes Defroster Fans COMPRESSORS...

Description. Construction

KUH. Horizontal Unit Heater. Applications. Description

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

SERVICE PARTS/OPERATION for

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

CF1 ProVector Explosion-Proof Heaters

INSTALLATION and OPERATION INSTRUCTIONS

Heating Products M arch 2012

X. Compact Condensers

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic hi l PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST FORD TRUCK

BLU Series Prep Tables. BLU Series Prep Tables. Models ITEM #

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us.

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

CIRRUS AIRPLANE MAINTENANCE MANUAL

OPERATING INSTRUCTIONS MANUAL FLE-150 INDUSTRIAL / COMMERCIAL ELECTRIC HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

Mobile Heated Cabinet

Rheem High Efficiency Air Handler

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

and Digital Thermostats

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

OPERATING INSTRUCTIONS MANUAL FLE-150 INDUSTRIAL / COMMERCIAL ELECTRIC HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

HIGH EFFICIENCY AIR HANDLER

Cooling/Heat Pump Convertible Air Handlers

Rheem High Efficiency Air Handler

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

( )

(770) wwww.southgateprocess.com

Table of Contents. Table of Contents Introduction... Intro-1

OPERATING INSTRUCTIONS MANUAL FLE-60 INDUSTRIAL / COMMERCIAL ELECTRIC HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

Replacement Parts List For Models COS-101 COS-101S

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Thru-The-Wall THDC Series R-410A Condensing Units Ton Series

INSTALLATION INSTRUCTION

GUIDE SPECIFICATIONS AQUARIUS ii

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

DIRECT DRIVE BLOWER COILS

INSTALLATION PROCEDURE 2011 Navistar MaxxForce 13L

Cooling/Heat Pump Convertible Air Handlers

To turn pages go to the bottom of page and left click with the mouse on the arrow or use the left and right arrow keys on the keyboard.

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST EARLY 1955 CHEVROLET PICKUP

Camaro A/C Install Instructions

Cooling/Heat Pump Convertible Air Handlers

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

CLIMATE CONTROL PRODUCT GUIDE

36,000-62,000 BTUH Nominal Capacity

CCS Rents! C C. S Contractor. Equipment & Supply, Inc. We offer a complete line of construction equipment for rent:

VERTICAL FAN COIL UNITS

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

Vertical Upflow Horizontal Left Air Handlers

INSTALLATION and OPERATION INSTRUCTIONS

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

HIGH EFFICIENCY AIR HANDLER

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

JOB-SITE HEATERS PROPANE KEROSENE ELECTRIC

TECHNICAL SPECIFICATIONS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

HEAVY DUTY HEATING & AIR CONDITIONING UNITS & ALL MAKES PARTS. ISSDistribution.com - Call (800)

Transcription:

Heaters PAGE 51

R-254 & R-255 Auxiliary Heaters TRUCKS RECREATIONAL These auxiliary heaters are among the most versatile and maintenance free units Red Dot has ever built. Red Dot's round tube and fin design allows heater mounting in any position, using our multi-position leg brackets or flush mount frame. The compact size, simple plumbing and high output are ideal in any application. R-254-4 Configuration Shown with mounting legs, floor exit R-254-0 Shown with mounting legs, rear exit SPECIFICATIONS R-254 R-255 BTU s 16,000 BTU/Hr @ 150 F 30,000 BTU/Hr @ 100 F (4kw 4.69 @ 65.6 C) air temp. rise (kw 8.79 @ 37.8 C) air temp. rise 150 CFM (255 m3/h) 280 CFM (476 m3/h) 7 lbs. (3 kg) 12 lbs. (5.5 kg) 3.3 amps @ 13.6 VDC 6.6 amps @ 13.6 VDC 1.7 amps @ 27.2 VDC 3.3 amps @ 27.2 VDC Models Single Fan Double Fan 5 8" fittings, rear exit: 5 8" fittings, rear exit: R-254-0P (12 VDC) R-255-10P (12 VDC) R-254-0-24P (24 VDC) R-255-10-24P (24 VDC) 3 4" fittings, rear exit: 3 4" fittings, rear exit: R-254-1P (12 VDC) R-255-1P (12 VDC) FLOOR EXIT 5 8" fittings: R-254-4P (12 VDC) FLOOR EXIT 5 8" fittings: R-255-12P (12 VDC) Heater Hose Toggle Switch Defrost Hose Outlet 3 1 2 78R0100 71R0100 RD-1-0639-0P Diagrams for R-254 Diagrams for R-255 7.25" 184 mm 7.25" 184 mm 3.75" 95mm 9.5" 241mm 3.75" 95mm 16.0" 407mm = Limited to stock on hand PAGE 53

R-270 Auxiliary Heater TRUCKS RECREATIONAL VEHICLES An extremely compact heater the R-270 series offers a highly tooled light weight design. There are three optional Snap In outlet configurations available which will allow for various air flow configurations. In addition Red Dot offers an optional installation kit which includes mounting hardware and fan switch. R-270 SPECIFICATIONS BTU s Heating 15,000 BTU/hr @ 100 F air temp. rise (4.4 kw @ 34.8 C) Motors 140 CFM (237 m3/h) 7 lbs. (3 kg) One 12 VDC (2 speed) 7.7 amps @ 13.6 VDC 3.8 amps @ 27.2 VDC R-270-0P (12 VDC) R-270-0-24P (24 VDC) R-290 Auxiliary Single Blower Heater Where air velocity is of utmost importance, Red Dot has added high performance three-speed motor blower assemblies to its compact heater models. The R-290 and R-295 (at right) auxiliary heaters deliver maximum BTU s with unsurpassed CFM. A defrost hose adapter is available to make ducting air possible. R-290 SPECIFICATIONS BTU s 20,000 BTU/Hr @ 150 F (kw 5.86 @ 65.6 C) air temp. rise 220 CFM (373 m 3 /h) 7 lbs. (3 kg) 4.3 amps @ 13.6 VDC (high speed) 2.7 amps @ 27.2 VDC (high speed) Models R-290-0P (12 VDC), 5 /8 fitting rear exit R-290-0-24P (24 VDC), 5 /8 fitting rear exit R-290-1-24P (24 VDC), 3 /4 fitting rear exit R-290-4P (12 VDC), 5 /8 fitting floor exit R-290-4-24P (24 VDC), 5 /8 fitting floor exit = Limited to stock on hand Snap In Outlets Straight 2 1/4 Hose Outlet 72R4532 Installation Kit RD-1-1654-0P Louvered Outlet 72R3157 4.5" 114mm 8.0" 199mm Defrost Hose Outlet Adapter Switch Knob 3 1 2 RD-1-0639-0P 71R1150 71R4050 11.52" 292mm 10.5" 273mm 7.5" 191mm 9.52" 242mm 7.34" 186mm = Limited to stock on hand PAGE 54

R-295 Auxiliary Double Blower Heater The bigger brother of the pair, with two high performance three-speed motor blower assemblies. The R-295 auxiliary heater delivers where it s needed most. Defrost hose adapter is available for this model too. R-2020 Auxiliary Heater-Defrost and Oil Cooler MARINE USE CONSTRUCTION INDUSTRIAL CABS R-295 SPECIFICATIONS BTU s 35,000 BTU/Hr @ 180 F (kw 10.25 @ 82 C) air temp. rise 430 CFM (730 m3/h) 11 lbs. (5 kg) 16 amps @ 13.6 VDC (high speed) 7 amps @ 27.2 VDC (high speed) R-295-0P (12 VDC), 5 /8 fitting rear exit R-295-0-24P (24 VDC), 5 /8 fitting rear exit R-295-4P (12 VDC), 5 /8 fitting floor exit R-2020 SPECIFICATIONS BTU s Heat 17,800 BTU/Hr @ 100 F (kw 5.21 @ 37.8 C) with water for heat source (BTU's per hour with oil for heat source lower) Motor 165 CFM (280 m3/h) 10.7 lbs. (4.85 kg) One 12 VDC or one 24 VDC single speed 6 amps @ 13.6 VDC, 3 amps @ 27.2 VDC R-2020-0P (12 VDC), R-2020-0-24P (24 VDC) 2 1 2'' Defrost Adapter 72R3601 3'' Defrost Adapter 72R3603 Swivel Fittings 70R7600 (Straight 5 8'' hose) 70R7650 (90 5 8'' hose) Hoses 78R0100 (Heater, 5 8 50ft) 78R0250 (Defrost, 2 1 2 9ft) 78R0300 (Defrost, 3 9ft) Switches 71R0050 (Toggle, ON-OFF) 71R1210 (Rotary, 3-speed) Mounting Bracket RD-1-0419-0P Defrost Hose Outlet Adapter Switch Knob 3 1 2 RD-1-0639-0P 71R1150 71R4050 (uses two) Shown with optional fittings and mounting bracket 18" 435mm 20.4" 519mm 7.5" 191mm 16" 407mm 5.1" 129mm 7.34" 186mm 8.0" 203mm PAGE 55

R-3500 HEATER Auxiliary Heater FIRE TRUCKS CRASH & RESCUE VEHICLES LARGE CABS The R-3500 crew cab heater was designed with high performance to be able to heat larger cabs in extreme conditions. Its low profile and heavy duty construction allows this heater to be used in various applications. R-3540 HEATERS Auxiliary Heater FIRE TRUCKS BUSES VANS Designed to fit small areas, the R-3540 delivers a lot of BTU's for its size. Using a pancake fan design, this unit is quiet and moves close to 200 CFM of air. The R-3540 has versatile mounting (either flat or horizontal) and contains a resistor for variable speed control. R-3500 SPECIFICATIONS BTU s Heating 49,000 BTU/hr @ 180 F (kw 14.35 @ 82.2 C) temp. rise 480 CFM (816 m3/h) 28 lbs. (13 kg) 15.9 amps @ 13.6 VDC R-3500-1P (12 VDC) R-3540 SPECIFICATIONS BTU s 22,970 BTU's/hr @ 180 F (kw 6.73 @ 82.6 C) air temp. rise 194 CFM (330 m3/h) 10 lbs. (4.5 kg) 4.8 amps @ 13.6 VDC R-3540-2P (12 VDC) NOTE: Gasket on front 23.7" 603mm 9.8" 248mm 11.0" 279mm 6.6" 168mm 7.8" 197mm 10.8" 273mm 5.4" 138mm 5.4" 138mm 1.7" 43mm 12.6" 321mm 13.4" 340mm PAGE 56

R-4013H Heater/Defroster Unit OFF ROAD CONSTRUCTION INDUSTRIAL The R-4013 is a compact, versatile and high output heater/defroster. Like other Red Dot heaters, the tube and fin coil design allows mounting in any position. Along with a two speed motor, a diversion door can be manually or cable operated to control defrost and heat output. An optional adapter to the heat outlet turns the R-4013 into a dual defroster or multi compartment heater. R-4013H SPECIFICATIONS BTU's Heating 20,000 BTU/hr @ 100 F (5.7 kw @ 37.8 C) air temp. rise 185 CFM (314 m3/h) 15.7 lbs. (7.1 kg) 11 amps @ 13.6 VDC, 5.5 amps @ 27.2 VDC R-4013HP (12 VDC) For 24 volt see R-6130 on the following page R-6130 Box Heater buses construction off-road The R-6130 s compact size makes for easy mounting in tight areas. With it s rotatable blower, ducting the heat up to the sleeper or cab is easily accomplished. R-6130 SPECIFICATIONS BTU s Heating 28,100 BTU s/hr @ 180 F (8.2 kw @ 37.8 C) air temp. rise Motors 283 CFM (481 m3/h) 12 lbs. (12.7kg) Permanent magnet, three-speed 17 amps @ 13.6 VDC 8 amps @ 27.2 VDC R-6130-1P (12 VDC) R-6130-0P (24 VDC) Heater Hose 3 1 2 Defrost 5 8 50 Adapter 78R0100 72R3550 8.8" 225mm 9.75" 250mm 13.65" 345mm 3.5" 89mm 9" 230mm 11.5" 292mm 4" 100mm Nipples 5 8" 16mm 11.6" 295mm 13.6" 345mm PAGE 57