MT4 MAX/MT4 MAX + Infrared Thermometer

Similar documents
62 MAX/62 MAX + Infrared Thermometer

62 MAX/62 MAX + Infrared Thermometer

62 MAX/62 MAX + Infrared Thermometer. Users Manual

62 MAX/62 MAX + Infrared Thermometer. Users Manual

62 MAX/62 MAX + Infrared Thermometer

64 Max IR Thermometer

64 Max IR Thermometer

Infrared Thermometer

Infrared Thermometer. Getting Started

700G Series. Pressure Gauge. Safety Information

Users Manual. Air Velocity Meter

3R, 3G 5R, 5G Point Laser Levels

Precision Infrared Thermometer. Users Manual

Users Manual. Visit us at

6R, 6G 180R, 180G. Users Manual. Point and Line Lasers. Line Laser Levels

562/563. Infrared Thermometers

Users Manual. Infrared Thermometer

Precision Infrared Thermometer. Users Manual

Dual Laser InfraRed (IR) Thermometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer

IRT2 Dual Laser IR Thermometer - User Guide

R2310. Infrared Thermometer. Instruction Manual

Dual Laser InfraRed (IR) Thermometer

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

C0-210 Carbon Monoxide Probe

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

I/R Thermometer Gun 12:1

Mobile solutions for extreme tasks. Ex-MX2

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual PCE-889 pyrometer

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

CONGRATULATIONS. on your purchase of a Viridian Reactor, the most advanced sighting device available. Technology on your new Reactor

KM300 Carbon Monoxide Detection System Installation Manual

NON-TOUCH THERMOMETER User Manual

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

HXL. Operating instructions

Visit us at testo 835 Infrared and contact thermometer

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

100 Ft. LASER DISTANCE METER

Digital Heat Block User Manual

Kinsa Smart Ear ThermometerTM Instructions For Use

Corning LSE Digital Dry Bath Heater

3M Benchtop Air Ionizer 963E. User s Guide

No Touch Door Release Exit Sensor ACA-NTEB

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

Vanguard. Toxic & combustible gas detector

Operation Manual Vortex mixer unitexer 1

Supplement. Title: 365 Users Supplement Issue: 8 Part Number: Issue Date: 7/16 Print Date: August 2010 Page Count: 6 Revision/Date:

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

Corning LSE 6L Digital Water Bath

User Manual. Non-contact Infrared Thermometer.

IFS Fiber Module Installation & Operation Instructions

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Customers must fill in and mail the warranty card in order to activate the warranty.

CA876 INFRARED K-THERMOMETER WITH LASER ENGLISH. User Manual. Auto OFF

Operator s Manual. IP-100 Immersion Probe Cooler

Polar H7 Heart Rate Sensor. User Manual

IFS Fiber Module Installation & Operation Instructions

PIR Sensor. User s Guide

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

2031A Quick Stick User s Guide

Reacti-Therm I and III Heating Modules

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Document No

Model 1916-C/-R Hand-held Optical Power Meter

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

OWNERS MANUAL OPERATION GUIDE

u Do not use the appliance if any part is damaged or defective. u Do not short battery terminals. u Do not charge batteries.

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

INSTRUCTION MANUAL P Heating and 1 Cooling

Series: MBC1-TC Mini Benchtop Temperature Controller

Installation, Operation & Service Manual

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

IFS Fiber Module Installation & Operation Instructions

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

CLETEF-786. Infrared Thermometer Instruction Manual

MD-MINI Dry Bath. Instruction Manual

User s Guide for the SunDanzer BFRV55

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

HIn3550 Magnetic Field Monitor User's Manual

Installation Manual February Opticom Infrared System. Model 575 Confirmation Light Kit

IMpORTANT SAFETy INSTRUcTIONS

Standard SPECIFICATIONS FEATURES APPLICATIONS

Transcription:

MT4 MAX/MT4 MAX + Infrared Thermometer Users Manual PN 4326561 August 2013 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands 11/99

Table of Contents Title Introduction... 1 How to Contact Fluke... 1 Safety Information... 2 Maintenance... 6 How to Change the Battery... 6 How to Clean the Product... 6 Specifications... 7 Standards and Agency Approval... 9 Nominal Surface Emissivity... 10 The Product... 11 Page i

MT4 MAX/MT4 MAX + Users Manual ii

Introduction The Fluke MT4 MAX and MT4 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of infrared energy radiated by the target s surface. Warning Read all safety information before you use the Product. How to Contact Fluke To contact Fluke, call one of the following telephone numbers: Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 China Mainland: +86-400-810-3435 Japan: +81-03-6714-3114 Singapore: +65-6799-5566 Anywhere in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. 1

MT4 MAX/MT4 MAX + Users Manual To register your product, visit http://register.fluke.com. To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. Table 1 tells you about symbols used on the Product and in this manual. 2 Warning To prevent possible electrical shock, fire, or personal injury: Read all safety Information before you use the Product. Do not use the Product if it operates incorrectly. Use the Product only as specified, or the protection supplied by the Product can be compromised. Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.

Infrared Thermometer Safety Information See emissivity information for actual temperatures. Reflective objects result in lower than actual temperature measurements. These objects pose a burn hazard. Do not look directly into the laser with optical tools (for example, binoculars, telescopes, microscopes). Optical tools can focus the laser and be dangerous to the eye. Do not look into the laser. Do not point laser directly at persons or animals or indirectly off reflective surfaces. Replace the batteries when the low battery indicator shows to prevent incorrect measurements. Do not use the Product around explosive gas, vapor, or in damp or wet environments. Use the Product only as specified or hazardous laser radiation exposure can occur. Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 C. If the batteries are not removed, battery leakage can damage the Product. Repair the Product before use if the batteries leak. 3

MT4 MAX/MT4 MAX + Users Manual Be sure that the battery polarity is correct to prevent battery leakage. Have an approved technician repair the Product. Carefully read all instructions. 4

Infrared Thermometer Safety Information Table 1. Symbols Symbol Meaning Symbol Meaning Risk of danger. Important information. See Manual. Conforms to relevant North American Safety Standards. Warning. Laser. Conforms to European Union directives. Battery Conforms to relevant Australian standards. Conforms to China Metrology Certification. This product complies with the WEEE Directive (2002/96/EC) marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as category 9 "Monitoring and Control Instrumentation product. Do not dispose of this product as unsorted municipal waste. Go to Fluke s website for recycling information. 5

MT4 MAX/MT4 MAX + Users Manual Maintenance Warning To prevent possible electrical shock, fire, or personal injury, have an approved technician repair the Product. Caution To avoid damage to the Product, do not leave the thermometer on or near objects of high temperature. How to Change the Battery To install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure 16. How to Clean the Product Use soap and water on a damp sponge or soft cloth to clean the Product case. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water. See Figure 17. 6

Infrared Thermometer Specifications Specifications MT4 MAX MT4 MAX + Temperature Range -30 C to 350 C (-22 F to 662 F) -30 C to 400 C (-22 F to 752 F) Accuracy (Calibration geometry with ambient temperature 23 C ±2 C) 0 C: ±2.0 C or ±2.0 % of reading, whichever is greater ( 32 F: ±4.0 F or ±2.0 % of reading, whichever is greater) -10 C to <0 C: ±2.0 C ( 14 F to <32 F: ±4.0 F) < -10 C: ±3.0 C (<14 F: ±6.0 F) 0 C: ±1.5 C or ±1.5 % of reading, whichever is greater ( 32 F: ±3.0 F or ±1.5 % of reading, whichever is greater) -10 C to <0 C: ±2.0 C ( 14 F to <32 F: ±4.0 F) < -10 C: ±3 C (<14 F: ±6.0 F) Response Time (95 %) <500 ms (95 % of reading) <500 ms (95 % of reading) Spectral Response 8 μm to 14 μm Emissivity 0.10 to 1.00 7

MT4 MAX/MT4 MAX + Users Manual Optical Resolution Display Resolution Repeatability (% of reading) Power Battery Life Weight Size Operating Temperature Storage Temperature Operating Humidity Operating Altitude Storage Altitude Drop Test 8:1 (calculated at 90 % energy) 0.1 C (0.2 F) ±1.0 % of reading or ±1.0 C (±2.0 F), whichever is greater 1 AA IEC LR06 Battery 10:1 (calculated at 90 % energy) ±0.8 % of reading or ±1.0 C (±2.0 F), whichever is greater 12 hours with laser and backlight on 220 g (7.76 oz) (156 x 80 x 50) mm (6.14 x 3.15 x 2) inches 0 C to 50 C (32 F to 122 F) -20 C to +60 C (-4 F to 140 F), (without battery) 10 % to 90 % RH non-condensing @ 30 C (86 F) 2000 meters 12,000 meters 1 m 8

Standards and Agency Approval Infrared Thermometer Standards and Agency Approval Ingress Protection Rating... IP40 per IEC 60529 Vibration and Shock... IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms Compliance... EN/IEC 61010-1 Laser Safety... FDA and EN 60825-1 Class II Electromagnetic Compatibility... 61326-1 EN 61326-2 Implement Standard... Q/SXAV37 9

MT4 MAX/MT4 MAX + Users Manual Nominal Surface Emissivity Material Value Material Value Default**** 0.95 Glass (plate) 0.85 Aluminum* 0.30 Iron* 0.70 Asbestos 0.95 Lead* 0.50 Asphalt 0.95 Oil 0.94 Brass* 0.50 Paint 0.93 Ceramic 0.95 Plastic** 0.95 Concrete 0.95 Rubber 0.95 Copper* 0.60 Sand 0.90 Food - Frozen 0.90 Steel* 0.80 Food - Hot 0.93 Water 0.93 Wood *** 0.94 * Oxidized ** Opaque, over 20 mils *** Natural **** Factory Setting 10

Infrared Thermometer The Product The Product 1 2 hdi01.eps 11

MT4 MAX/MT4 MAX + Users Manual 3 4 / 5 5 6 Max/Min/Avg/Diff hdi14.eps 12

Infrared Thermometer The Product 7 10 min OFF hdi16.eps 13

MT4 MAX/MT4 MAX + Users Manual 8 9 10 30 Min 12 11 0 ºC 32 ºF 9 6 3 22 ºC 72 ºF 125 F hdi15.eps 14

Infrared Thermometer The Product 12 13 40 mm @ 300 mm 75 mm @ 600 mm 120 mm @ 900 mm 38 mm @ 300 mm 60 mm @ 600 mm 100 mm @ 900 mm S S 1.6" @ 12" 3" @ 24" 4.7" @ 36" 1.5" @ 12" 2.4" @ 24" 4" @ 36" D D MT4 MAX D:S = 8:1 MT4 MAX + D:S = 10:1 hmp08.eps 15

MT4 MAX/MT4 MAX + Users Manual 14 70 21 hdi03.eps 16

Infrared Thermometer The Product 15 75 225 75 hdi04.eps 17

MT4 MAX/MT4 MAX + Users Manual 16 17 hdi13.eps 18