Wall Controller & Thermostat

Similar documents
OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

OWNER S MANUAL. Evaporative Cooler. (English) (EA, EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

REMOTE CONTROL FAN SPEED ECONOMY BATTERY LOW. owner s manual

Safety / Kit Components 1

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM)

Spectrolink Comfort Control. Home Owner's Manual Heating

HOME OWNER S MANUAL. Spectrolink Comfort Control - Heating

OWNER S MANUAL. CPL Evaporative Cooler. (English) (CPL) ILL1456-A

Spectrolink Comfort Controller. Home Owner's Manual Heating. baby, outside. Come home to ECOST R

PRODUCT GUIDE. Seeley International Americas 1002 S 56 Ave Suite 101 Phoenix AZ Phone Fax Web Seeleyinternational.

OWNER S. m a n u a l C P L S E R I E S

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English)

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

ST9400A User Guide. Features

Owner s Manual. Part Number 33CS250-RC

INSTALLATION MANUAL. TBA Evaporative Cooler. (English) (TBA) ILL1456-A

OWNER S MANUAL. Part Number P RF

INSTALLATION MANUAL TBA Evaporative Cooler

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

SCC1 GROZONE CLIMATE CONTROLLER The Simple One Series...

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English) ILL1672-A

Elegance. SMT-700 User manual. Ver

Digital Programmable

Brivis Touch Controller. Installer Manual

1F90-71 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat

Remote Control Operation Manual Split Type Air Conditioner

1F90W-51 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat WHITE-RODGERS

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

Product Manual SZ1009

99 F PREHEAT. C d. Topside Controls for Spas with Three Pumps

SAT-3 Room Temperature Controller

Operating Functions Temperature Parameters

Version 1.03 January-2002 USER S MANUAL

User instructions DHP-AT

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

1F97-51 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 7-Day Programmable Electronic Digital Thermostat

Using the. Ducted Gas Central Heating Dual Cycle Refrigerated Air Conditioning Ducted Evaporative Air Conditioning. with your.

OWNER S MANUAL LCQ / LCS / LCQI / BMQ / CPQ TBQ / TBS / TBQI / TBSI Evaporative Cooler

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats

Smart Temp. Model

DYGIZONE GJD910 Lighting Controller & Enunciator

User Guide Y9420H Sundial RF 2 Pack 2

7-Day Electronic Timer Model CDN Operating Instructions

DAY/TIME Button: Selects hour, minute and day setting.

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

CONTROLS INSTRUCTIONS MANUAL ENGLISH

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Installation, Start-Up, and Operating Instructions

DAY/TIME Button: Selects hour, minute and day setting.

HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP INTERVAL DECREASE

OWNER S & INSTALLATION MANUAL RPCQ / RPC Evaporative Cooler

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

Instruction FH-CWP Thermostat

Installation guide. iheat thermostat. TB7100A1000 MultiPRO TM multispeed and multipurpose thermostat

USER GUIDE VOGUE MAX SYSTEM

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

OWNER S MANUAL Venstar Inc. 08/07

NetworX NX-8V2. LED Keypad User Manual

2200 and 2200L ALARM CONTROL SYSTEMS

Installing and operating your Cabinet Cooling System, with Digital Thermostat

Installing and operating your Enclosed Cabinet Cooling System and digital thermostat

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

IFT-RC400 IntelliFire Touch Remote Control

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

INSTALLATION MANUAL. CPL CPS LCB BM Evaporative Cooler. (English) (CPL CPS LCB BM) (Original English Instructions) ILL1456-A

U ser's Guide PC6010

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

User Manual for the. ACCS-1 Digital 7 Day Programmable Thermostat with Zone Control

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

USER'S OPERATING INSTRUCTIONS

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

INSTRUCTIONS MANUAL CONTROLS. Description Power Rating Remarks Steamer. Description Power Rating Remarks Control

HEAT PUMP PROGRAMMABLE THERMOSTAT

Important safety instructions

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

OWNER S MANUAL Venstar Inc. 08/07

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

Service Manual Models: 1.0, 1.3, and 1.5

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

CR2003 ROBERTS. 3 band Auto set PLL Synthesised Clock Radio. Sound for Generations. Please read this manual before use

OPERATING INSTRUCTIONS. G214 Software - Version 4

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

ENGLISH REMOTE CONTROL MANUAL

ETN-24-HC21-PROG Econo-Vent

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

ELECTRONIC AIR CONDITIONING CONTROL

SETTING UP GUIDE. This Handbook is for the Installer. You must read these instructions prior to installing and commissioning the Credanet system.

534I, 650, 739I, 1200, 1300, 1500, MF28I

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Transcription:

Wall Controller & Thermostat Thank you for purchasing a Genuine component from Seeley International. This Wall Controller has been engineered and manufactured to the highest standard to maximise the performance of your cooling system. During this time Preparing to Start will flash on the display. ILL2419-A CTROLLER SETTINGS Wall Controllers can operate in manual or automatic mode. Manual mode Manual mode will allow you to change settings for operating the cooler, such as altering fan speeds, pump control and manual drain control. Auto mode Auto mode will allow thermostatic control to set temperature targets/operating settings. It has the capability of programming /OFF delay times, enabling the cooler to automatically start up or shut down after a specified period of hours. At all times the Wall Controller will monitor the cooler for faults and report them to the controller s screen for your reference. ILL1122-A Manual Mode With the wall control switched, press the button until MAN is shown on the display. You may then press the button to switch between COOL and VENT (where fresh air is being delivered but not cooled). Once COOL or VENT has been selected, the wall control will maintain a constant fan speed. This is indicated by the bar graph shown on the display. To increase or decrease the fan speed required, press either the or button. Auto Mode To select the mode press the until is shown on the display. button CTROLLER OPERATI Preparing to Start Whenever you select mode or COOL in MANUAL mode, the cooler will take a few minutes to start as it fills with water and saturates the cooling pads. The time will be decreased if the tank is full or the cooler has only recently been turned OFF. ILL1124-A In mode the cooler will remember the last setting used. To change the setting use the and buttons. Don t alter the setting however, until the room temperature has stabilised.

CTROLLER OPERATI cont. Delayed Start or Stop The cooler can be programmed to start at a specific time or stop at a specific time. The delayed start time can only be programmed when the cooler is OFF. To program the cooler to start in a certain amount of hours use the following sequence: Programming In Manual Mode (1)... Press the button. (2)... Press the button until MAN is displayed on the screen. (3)... Press the or button until the desired fan speed is displayed by the bars in the middle of the screen. The delayed stop time can only be programmed once the cooler is. This is ideal if you are going to bed but don t want to turn the cooler off straight away. To program the delayed time in which you want the cooler to stop use the following sequence: (1)...Select the button and the stops in time will start flashing. Use the and buttons to select the desired off time. (2)...Press again. ILL1118-A (4)... Press the button to set either COOL or VENT. (5)... Press the button and the starts in time will start flashing. Use the and buttons to select the desired time. (6)... Press again. Programming In Auto Mode (1)... Press the button. (2)... Press the button until is displayed. (3)... Press the button and the starts in time will start flashing. Use the or button to select the hour. (4)... Press again. ILL1117-B ILL1119-B Drain Mode (Cooler switched OFF) If fitted with a Water Management system, pressing the and buttons at the same time for 2 seconds will open the drain valve and empty the water in the tank. The wall control will display dr on the screen. Changing the Water Management method for the control To enter Parameter mode, the following process must be carried out within 4 minutes of power being applied to the cooler. If unsure of time since the last power, remove power to the cooler (Isolator Switch or Circuit Breaker) for a minimum of 6 seconds so the mode can be entered. 1. While wall control is OFF, push and hold for minimum three (3) seconds. After three (3) seconds while still holding button press the button. (If button is pressed before three (3) seconds, nothing will be on the display. If button, is continued to be held subsequent presses of button will allow access). 2. When parameter mode has been entered, screen will display A1 - (Water Salinity Control Method) and Param. 3. To view parameter number set in wall control press momentarily. Figure A# on screen will change to number set, and Param will change to value.

CTROLLER OPERATI cont. 4. To alter the value of selected parameter press or. Numbers will change to show different values the parameter can be set to. Water Manager = 0 Timed Drain (CPQ/BMQ Upgrade Kits) = 1 Non-Drain Valve salinity control (bleed etc) = 2 5. To store the value, press. Screen will go blank momentarily as wall control stores parameter change, and returns screen to A# and Param. 6. To exit parameter mode or escape from an alteration without storing a change press button instead of button. Remember, once step 5 has been carried out, new parameter change is permanent until again altered. 7. If no buttons are pushed on wall control, after 3 minutes screen will reset to OFF state. Procedure to enter parameter mode must be re-initiated. For models where water management probes and drain valve are fitted, the drain frequency is typically managed by salinity control. There should be no need for adjustment. However if you do wish to change from salinity control to a set interval timed drain, follow these programming steps. While the thermostat is OFF, hold down for at least 3 seconds and then press while still pressing. The setting A1 will be displayed, release both buttons and then press. A number will now be displayed. Press or until the number displayed corresponds to the desired setting; 0 = Salinity Control 1 = Timed Drain. Press to complete the adjustment. Exit the programming mode by pressing. Wall Control Displays Service If on initial Installation of a Cooler, or after the wall control has been changed, the word SERVICE appears on the Wall control screen and the unit does not respond to the pushing of any buttons even though the backlighting responds. This is easily rectified and means that communication needs to be established between the Wall control and the electronic controller inside the Cooler. To establish communications simply push and hold the DOWN button until the word SERVICE disappears from the screen and the temperature appears. This may take up to 10 seconds. Once communications has been established the unit can be operated.if by pushing the on/off button a number appears, see Service Mode Notifications. ILL2122-B Service Mode Notifications When a fault has been recognised by the wall control the word Service and a Number flashes on the screen. ILL1121-B Please write this number down, then push the button to turn the cooler back on. If after a short time Service is again shown on the display, turn the wall control OFF and check if the flashing number is the same. If it is the same check the Cooler Control Box LED Indicators section for possible problems. However, we do recommend that any checks be carried out by an authorised dealer or service agent.

REMOTE THERMOSTAT CTROL REMOTE CTROL The clock can be set to either 12 or 24 hours. If the clock is set to 12 hours make sure that the AM/PM displayed on the screen is correct. AM/ PM will change with adjustment of the hour. ILL1104-A ILL239-A Horizon Remote Control - Setting the Address Code Within 4 minutes after turning on the mains power at the electronics module. The Breezair electronics module will automatically recognise the Horizon remote control connection, provided the address code has been correctly set. This is simply achieved by fitting the batteries into the remote control The screen will stay blank for 5 seconds then display Id. The address code will take a few seconds to set, then the remote control can be turned on. If communication cannot be achieved, the power to the cooler will need to be turned off, and the batteries need to be removed from the remote control. Wait until the screen goes completely blank, then repeat the above procedure. Setting the Clock Set the clock on the remote control before proceeding with any other programming. The clock can only be set with the remote control switched OFF. Hold the button down for over 2 seconds, until the hour flashes. Use the and buttons to change the hour. To change minutes, press the button again. Change the minutes using the and buttons. To lock in the time setting, and enter the OFF state, press the button. The display will stop flashing. Turning on the Cooler The remote control is switched on and off using the button. The memory will store and use the settings from when the cooler was last used. Once the remote control is on, you can choose between MANUAL, and modes by pressing the button. Manual Mode With the remote control, press the button until MANUAL is shown in the top left corner of the display. MANUAL FAN SPEED VENT ILL1109-A COOL ILL1108-A The button is used to select VENT (where fresh air is being delivered without being cooled) or COOL. Once either COOL or VENT has been selected, the remote control will maintain a constant fan speed. This is indicated by the bar graph in the centre of the display. To decrease or increase the fan speed required, press either the or buttons.

REMOTE THERMOSTAT CTROL Auto Mode The remote control contains a thermostat. In mode the cooler is controlled automatically, based on your pre-selected comfort level. The cooler will adjust the fan speed, switch between COOL and VENT and turn itself off. However, the sequence and regularity at which these settings change will differ with each operation of the cooler. As the remote control senses room conditions, the comfort control settings will be influenced by heat from direct sunlight or electrical appliances. Likewise placing the remote control in cupboards or drawers or under cooling vents will affect the cooler s operation. To set the mode press the button until is displayed. FAN SPEED ILL1105-A Ten levels of comfort are available with the remote control. While in mode pressing the and buttons will adjust the level of required comfort. The display will show your selection by indicating a level between 1 and 10. WARMER or COOLER will be displayed on the screen as settings are changed. Auto Timer Mode mode can be selected by using the button. Once the mode is selected the cooler will only operate during the programmed time period. Programming the timer must be performed before can be activated. This can be done while in any mode, even when it is OFF. There are 7 steps involved in setting the. NOTE: After pressing the button the display will revert back to the previous setting if no buttons are pressed within 4 seconds. To program the timer use the following sequence: (1) Setting the time - hour Begin by pressing the button. The hour displayed will start flashing and the word will appear on the screen. Then use the and buttons to change the hour value. ILL1112-A (2) Setting the time - minute Press the button. The minutes displayed will start flashing and the word will appear on the screen. Then use the and buttons to change the minute setting. ILL1113-A (3) Setting the OFF time - hour Press the button. The hour displayed will start flashing and OFF will be displayed. Then use the and buttons to change the hour. OFF ILL1114-A (4) Setting the OFF time - minute Press the button. The minutes displayed will start flashing and the word OFF will appear. Then use the and buttons to change the minute setting.

REMOTE THERMOSTAT CTROL (4) Setting the OFF time - minute cont. (5) Setting the comfort level Press the button and the comfort level number (1 to 10) displayed will start flashing. Then use the and buttons to change this setting. (6) Setting ECOMY To select economy press the is displayed on the screen. (7) Activating Now that you have programmed the settings for they will be stored in the remote control s memory until you change them. Press the button until is displayed on the screen. Your cooler will now only operate during the programmed time period. NOTE: To change any settings when the remote control is switched off, the button needs to be pressed and released within 1 second. To change settings when the remote control is turned on press the button until the desired number is flashing. OFF ILL2416-A ILL1116-A button so that it Economy Mode Selecting the ECOMY mode limits the maximum available cooling or ventilation and reduces the power used by up to 20%. The ECOMY function can be used in either or MANUAL modes. To select this mode press the button so that ECOMY appears on the display. MANUAL FAN SPEED Pre-cool Mode Your remote control is designed to allow for the saturation of the cooler s cooling pads before the fan is switched on. This function, referred to as PRE-COOL mode, is enabled at DIP switch 4. Once it is enabled the cooler, when first switched on, will operate as follows: (1)... If the tank is empty the drain system will be closed. The tank will then be filled. (2)... After 60 seconds of the tank filling with water, the pump will turn on and saturate the filter pads. (3)... After the pump has been running for 3 minutes the fan will start. During this operation the word PRE-COOL will be displayed on the remote control s screen. COOL PM ECOMY ILL1125-A Drain Mode Pressing the button opens the drain valve in the cooler and empties the water in the tank. This will leave the tank clean and dry and turn the cooler off. DRAIN TANK ILL1107-A If the cooler has not been used for 3 days or 3 hours, depending on the DIP switch setting, the tank will automatically be drained to ensure the system remains clean.

REMOTE THERMOSTAT CTROL Pre-cool Mode cont. MANUAL FAN SPEED PRE-COOL COOL NOTE: PRE-COOL mode will not be activated if VENT is selected on the remote control or the cooler is used again shortly after having been turned off. PM ECOMY ILL1142-A Dip Switches WARNING: Once communication between remote and control box has been established, do not alter DIP switches 1 to 8 in the top row and 7 & 8 in the bottom row as the cooler will cease to work. There are 2 rows of DIP switches located under the battery cover on the remote control. COOLER CTROL BOX LED INDICATORS The top LED is tri-colour and can glow green, red or amber. The bottom LED is red only. If the top LED is double flashing green, everything is ok, this is normal operation. Tri-colour Red OFF 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 EXAMPLE LY ILL217-H Direct Drive coolers ILL2417-A Definition of DIP switch positions (first 6 in bottom row only) are as follows: 1. Reserved for later use. 2. OFF, 24 hour clock,, 12 hour clock. 3. OFF, 1100 / 1500W motor,, 500 / 550 / 750W motor. 4. OFF, no pre-cool,, pre-cool. 5. OFF, drains 3 days after power off., drains 3 hours after power off. (Only for coolers fitted with Solenoid, Probes and Drain Valve). 6. OFF, drains every 65 minutes of operation,, activates water salinity circuit (WATERMANAGER). (Only for coolers fitted with Solenoid, Probes and Drain Valve). Axial Coolers Tri-colour Red ILL2418-A

COOLER CTROL BOX LED INDICATORS cont. The Tricolour (top) LED acts as a general diagnostic indicator, and will function as follows: Green double flash every 2 seconds: The control is running normally. If it does not glow at all, then there is either no power to the electronics module (check isolating switch, circuit breaker, plug and socket connection in the roof space), or a failure has occured. Amber for 1 second (Horizon remote controls only): The Electronics Module has received a command at an incorrect ID address. (See the Horizon remote control - setting address code section above, to re establish the code) Red Flashing: one or more of the following faults is present: 1 Red Flash: Fault Code #1 Communication Failure. 2 Red Flashes: Fault Code #2 Failure to Detect Water at Probes. (Only for coolers fitted with Solenoid, Probes and Drain Valve). 4 Red Flashes: Fault Code #4 Failure to Clear Probes during drain. (Only for coolers fitted with Solenoid, Probes and Drain Valve). 7 Red Flashes: Fault Code #7 - Incorrect Supply Frequency. The Red (bottom) LED indicates the status of the WaterManager measurement circuit and will function as follows: 1 Flash: The WaterManager is operating and the measured salinity is at the set point. 2 Flashes: The WaterManager is operating and the measured salinity is above the set point. 3 Flashes: The Salinity Control Method = Drain every 65 minutes. 4 Flashes: Incorrect Salinity Control Method selected. Continuously On: The probes are open circuit, or measured salinity is less than 20us/cm (the water is very pure, ie; has very little salt content). Please note All service and maintenance work should be carried out by suitably trained and licensed personnel. For your local service agent visit and click on the get support tab. Warranty Service Australia 1-300-650-644 It is the policy of Seeley International to introduce continual product improvement. Accordingly, specifications are subject to change without notice.