M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Similar documents
For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

RG7D 1-Stage Heat Series

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

G6RC Series TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

TECHNICAL SPECIFICATIONS

RE9X Series Downflow, Upflow Electric Furnaces

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

E3EH-xxx-H Series E3EB-xxx-H Series

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Comfort, Quality and Efficiency.

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Multi-Position Gas Furnaces

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Ruud Acheiver Series Upflow Gas Furnaces

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

MULTI POSITION GAS FURNACE

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Ruud Achiever Series Multi position Gas Furnaces

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

Rheem Classic Series Multi-position Gas Furnaces

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

Ruud Achiever Plus Series Multi-position Gas Furnaces

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

MERIT SERIES Downflow

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Rheem Classic Plus Series Multi position Gas Furnaces

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

MULTI POSITION GAS FURNACE

Downflow/Horizontal Right Induced Draft Gas Furnace

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

HIGH-EFFICIENCY FURNACES

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing

80% A.F.U.E. DOWNFLOW GAS FURNACES

13 GEP A L P - 1 A

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Energy Saving. Space Saving.

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Residential/Commercial Gas Condensing Tankless Models

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

Upflow/Horizontal Condensing, Gas-Fired Furnace

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

GAS FURNACES. Visit taxcredit for complete details.

Multi-Position Gas Furnaces

GMS9/GCS9 SERIES 93% AFUE

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

8+* Bulletin No November 1997

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Transcription:

TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially designed for Modular Housing. It may be installed in a utility room, or enclosed in a closet. CSA design certified for use in the United States and Canada. FEATURES and BENEFITS 100% fired and tested: All units and each component (both mechanical and electrical) are tested on the manufacturing line. Clean and quiet operation: Due to the unique design of in-shot burners, location of inducer and use of insulation. Fixed 30 second blower delay: At burner start-up assures a warm outlet air temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds). Fixed 30-second post purge: Increases life of heat exchanger. Dependable, hot surface ignitor: Innovative application of an appliance type ignitor with a 20-year history of reliability. Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life. Stainless steel secondary heat exchanger: Assures a long life. Fixed cooling cycle blower-off delay (TDR): Increases cooling performance when matched with a NORDYNE coil. Sealed combustion approved for direct vent furnace, category IV venting system: May be vertically or horizontally vented using a two-pipe system for maximum flexibility in installation. Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. 40VA transformer included. LP convertible: Simple burner orifice and gas valve regulator change for ease of convertibility. Diagnostic light flashes identify limit failure, pressure switch failure and improper ground and polarization: for easy troubleshooting. 3 amp fuse protection against low voltage shorts: Protects transformer and control board. Low voltage terminal board: For easy field wiring. Easy open pawl latch: Secures the door firmly for transit, yet allows easy removal for access. Appliance quality door: Protects against rust and other corrosion. Baked enamel finish allows for easy cleaning. Fully insulated cabinet: Insures minimized heat loss and quiet operation. BW Models BWT Models Note: The M3RL will fit in the same footprint and uses the same duct connector as the M1 funaces. The design of the M3RL allows for direct substitution in place of the M1 series furnaces.

1.000 12.000 MARKS FOR DRILLING LOCATION (2) 1.000 21.000 12.000 SIDE WALL REAR WALL ALT. FUEL LINE HOLES KNOCKOUTS (4) 4.466 CL FUEL LINE HOLE 10" C L FLOOR OPENING 23-1/4" 5.550 Top Return Knockouts (AW & BW Models) Alcove 18-1/2 12.00 4.466 24 x 16 FILTER TOP FILTER BRACKET 1.000 12.000 1.000 9.830 18-1/2 SIDE FILTER BRACKET MARKS FOR DRILLING LOCATION (2) 21.000 Side Return Knockouts Top Return Filter Top Return Opening (BWT Models) 2

FEATURES High Efficiency Downflow 90+ Gas Furnace Downflow Furnace 1 Door Assembly - Louvered (AW & BW Models) Door Assembly - Non Louvered (BWT Models) 2 Filter Inside Door (AW & BW Models) 2 3 Blower Assembly 4 Control Board 5 Pressure Switch 6 Flame Rollout Switch 7 J Trap Hard Tube 8 Low Voltage Transformer 9 In Line Drain Assembly 10 Junction Box 11 Vent Safety Switch 12 Ignitor Assembly 13 Burner View Port 14 Main Limit Switch 15 Coil Cabinet Assembly (BW & BWT Models) 16 Flame Sensor (On Burner Box) 17 Gas Valve 18 Switch, On/Off 19 Blower, Inducer 20 Orifice (In Burner Box) 21 Aux. Limit 22 Burner Box 1 3 21 18 4 5 19 6 22 7 17 8 9 10 11 16 12 13 14 SPECIFICATIONS M3RL MODEL NUMBERS: -060A -080A Input-Btuh (a) 60,000 80,000 Heating Capacity - Btuh 54,000 72,000 AFUE 90.0 90.0 Blower D x W 10 x 10 10 x 10 Fuse or Breakage Size 15 Amps 15 Amps Heat Anticipator Setting 0.5 0.5 Manifold Pressure Nat. Gas 3.5" WC 3.5" WC LP Gas 10" WC 10" WC Motor H.P. -Speed -Type 1/2-4 -PSC 1/2-4 -PSC Motor FLA 7.9 7.9 Maximum Ext. SP - In. W.C. 0.5 0.5 Temperature Rise Range - F 35-65 35-65 15 STANDARD EQUIPMENT Direct vent; draft inducer; pressure switch; redundant main gas control; hot-surface ignition; timed ON/OFF blower controls (TDR); 40VA transformer for air conditioner application; limit controls; direct drive motor; all models can be converted to use LP (propane) gas. Furnace Model Shipping Weight (lbs) M3RL 060A AW 150 M3RL 060A BW* 170 M3RL 080A AW 155 M3RL 080A BW* 175 *May include suffix - T Shipping Weights Note: All models are 115V, 60 Hz. Gas Connections are 1/2" N.P.T. AFUE = Annual Fuel Utilization Efficiency (a) Ratings to 4,000 ft. Over 4,000 ft. reduce 4% for each 1,000 ft. above sea level. 3

DIMENSIONS 21-11/32 COMBUSTION AIR INTAKE 17-13/16 EXHAUST VENT 19-7/8 1-1/2 3-17/32 COMBUSTION AIR INTAKE 1-11/16 EXHAUST VENT 24-5/8 SIDE RETURN KNOCKOUTS 18-1/2 SIDE RETURN KNOCKOUTS 18-1/2 21-17/32 21-29/32 7/8 Diameter 28-15/32 56-1/16 (W/O Coil Box) (W/ Coil Box) 75-1/4 23-7/16 20-9/32 21-15/16 3-17/32 1-19/32 3-17/32 1-19/32 4-11/16 4-11/16 Cooling Coil Box 19-3/16 20-1/16 24-3/4 BLOWER PERFORMANCE Furnace Model No. Furnace Input Btuh Furnace Output Btuh Temp. Rise @.3"WC F CLOSET ALCOVE ALL MODELS Inches Inches Front 1* 1* Back 0 0 Sides 0 0 Vent 0 0 Top 6 6 Duct (Plenum) w/ Coil Box 0 0 w/o Coil Box 1/4 1/4 (within 3 feet) *Note: For 1" clearance, use a fully louvered door with at least 400 square inches of free airflow area. Motor HP M3RL-060 60,000 54,000 35-65 1/2 M3RL-080 80,000 72,000 35-65 1/2 Minimum Clearances External Static Pressure ( Inches Water Column) Recommended Motor 0.1 0.2 0.3 0.4 0.5 A/C Speed CFM CFM CFM CFM CFM Ton High* 1660 1599 1544 1474 1410 4 Med-High 1512 1467 1416 1363 1304 3 Med-Low 1340 1304 1261 1217 1158 2.-1/2 Low** 1176 1142 1108 1025 966 2 High* 1660 1599 1544 1474 1410 4 Med-High 1512 1467 1416 1363 1304 3 Med-Low** 1340 1304 1261 1217 1158 2.-1/2 Low 1176 1142 1108 1025 966 2 Note: Data is for Operation with Filter. * Factory Wired Cooling Tap ** Factory Wired Heating Tap 4

ACCESSORIES Description Part Number Automatic Cavity Damper 901083 "VEE" Box Adapters (10") - 5 / carton 901985 Duct Connector 10" x 6" - 6 / carton 902926 "VEE" Box Adapters (12") - 5 / carton 902149 Single Wide Fitting Kit (12") Double Wide Fitting Kit (12") 911468A 911469A Single Wide Fitting Kit (14") 914957 Double Wide Fitting Kit (14") 914956 Y-Fitting (12") 911470 Y-Fitting (14") 917195 A/C Coil Box 911969A Side Return Air Kit 904003 Top Return Air Kit 904015 Sloped Roof VentilAire III Kit 914098 Sloped Roof VentilAire IV Kit 914229 Soffit VentilAire Kit 917201 Concentric Vent Termination Kit (for horizontal and vertical venting) 904953 Horizontal Exterior Vent Mounting Kit 3"PVC 902375 Neutralizer Kit - All Models 902377 ACCESSORY VENT KITS Vent Kits Part Number Soffit Air Inlet (for VentilAire III only) 917201 Air Tube Kit M (high capacity M Series gas/oil furnaces) 914118 VentilAire III - Sloped 3/12 914098 VentilAire IV - Sloped 3/12 914229 Duct Connectors Part Number 11.25 x 13.50 x 0.88 12 / carton 901987A 11.25 x 13.50 x 2.00 12 / carton 901988A 11.25 x 13.50 x 4.25 6 / carton 901989A 11.25 x 13.50 x 6.25 6 / carton 901990A 11.25 x 13.50 x 8.25 4 / carton 901991A 11.25 x 13.50 x 10.25 3 / carton 901992A 11.25 x 13.50 x 12.25 3 / carton 901993A 11.25 x 13.50 x 6.25 24 / carton 902681A 5

IDENTIFICATION CODE Application M-Modular Home Furnace Series Comfort Model RL - Condensing Downflow M 3 R L - 060 A - A W Heating Capacity Input, BTUH (000 ) Return Air Configuration Blank - Front T - Top Door Color W - White Cabinet Dimensions A - 56" x 19-3/4" x 23-3/4 B - w/coil Cavity, 76" x 19-3/4" x 23-3/4" Electrical Code A - 1PH, 60 Hz, 120 VAC VENTING All models are approved for both vertical and horizontal direct (2 pipe) venting applications. See Vent Table below for specified sizes and allowable lengths. VENT TABLE APPLICATION PVC,CPVC or ABS SCH. 40 Pipe Size DIRECT VENT, DUAL PIPE LENGTH (ft.) with 1 long radius elbows on each pipe.* Inlet/Outlet 3" 3" Model M3RL 060 50 50 Model M3RC 080 50 50 *NOTES 1. Subtract 3.5 ft. for each additional 3" 90 degree elbow. 2. Two 45 degree elbows are equivalent to one 90 degree elbow. 3. One short radius elbow is equivalent to two long radius elbows 4. Do not include termination elbows in calculation of vent length 5. This table is applicable for elevations from sea level to 4,000 ft. For higher elevations decreasevent pipe lengths by 8% per 1000 ft. of altitude. 6. Only the above pipe materials are approved for use with these condensing furnaces. 6

7

GENERAL TERMS OF LIMITED WARRANTY For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the NORDYNE warranty department for a copy. 307B-0811 (Replaces 307B-0111) 8000 Phoenix Parkway O'Fallon, MO 63368-3827 Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (08/2011)