Installation Instructions for W2H Series Signals

Similar documents
Flex-Tone Explosionproof Electronic Signals ETH655 & ETH855 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Installation

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

Installation and Operation of the Catalog Number 5541M-Y6 Millennium System Master

MODELS 304GC, 304GCX, 314GC, and 314GCX

MODELS ASHP, ASHH, ASUP, and ASUH

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

INSTRUCTION MANUAL (ATEX / IECEx)

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

July 14, 1999 DF C-100.

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Alarm Tone Generator Model AG17

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Power Supply Display Module PSDM. Installation and Operation Manual

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

INSTRUCTION & SERVICE MANUAL

SP-1000X. Panic Device Power Controller Installation Guide. Rev

SP40S-D. Kingfisher Company, inc. Features: Description:

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07

INSTRUCTION & SERVICE MANUAL

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

SECTION AUTOMATIC TRANSFER SWITCHES

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

Public Safety DAS Annunciator Panel

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

M O D E L S FIREGARD BV EXTENDED PERFORMANCE RELEASE DEVICE

RELEASE DEVICE CONTROLS

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

Installation & Operations Manual

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Ramsey Motion Monitoring Systems

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

MANUAL RESET ALARM RELEASE BOX

FAN POWERED VAV TERMINALS

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

MODEL B2 INSTALLATION MANUAL

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

Dual Column Dehydrating Breather Manual

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

Booster Power Supply Manual

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Figure 1. Figure 2. See notes 1 and 2 below.

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

Model 5100A, 5200A, and 5100ALBV Owner s Manual

Cold Door 2 LED Retrofit Kit Lighting System

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Beacon 800 Gas Monitor Operator s Manual

INSTRUCTION MANUAL (ATEX)

standards: standards:

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

SAFEPATH SP40/2 D10 D35 AMP P/N P/N Installation, Testing, TONE SW Operation, and W4 Maintenance D54 SHORT

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

PO Box 827 Hawley, MN (218) Fax (218)

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

Addressable Detectors & Bases

Informer100 Speaker Models I-IP100AC and I-IP100DC

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Thermal Stability Systems

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Transcription:

Installation Instructions for W2H Series Signals IF1513 A Description and Operation DIMENSIONS W2H A 8 7/8" (225 mm) B 8 1/4" (210 mm) C 13" (330 mm) Figure 1. Speaker/Amplifier Dimensions The W2H signaling device is a heavy-duty, tone-selectable, stand alone, indoor/outdoor audible signaling device intended for industrial applications where high audible output and microcomputer reliability are required. Both the W2H620-4T and W2H840-4T series are UL and cul listed as audible signal Appliances for use in the following hazardous locations. The W2H operates from local power. It accommodates up to four normally-open contacts on its inputs. The tone that sounds in response to an active input is determined by setting miniature programming switches inside the unit. Figure 13 has switch settings for setting tones. Four tones may be programmed into the unit at any time. These tones operate on a pyramid-type priority system. Electrical Specifications Input Board Main Power Catalog Current (A) Number Voltage Current Voltage Standby Tone On Standard Volume W2H840-4T 24V DC 6 ma 24V DC 0.10 0.74 24V AC 50/60 Hz 0.10 1.3 W2H620-4T 24V DC 6 ma 125V DC* 0.10 0.21 250V DC* 0.02 0.10 120V AC 50/60 Hz 0.10 0.32 240V AC 50/60 Hz 0.10 0.20 Installation The W2H signaling devices may be mounted to any flat surface or may be used as a freestanding unit mounted to a rigid pipe. The W2H must be installed in accordance with the latest edition of the National Electrical Code or other regulations applicable to the country and locality of installation and by a trained and qualified electrician. For W2H840-4T 24V AC power must be transformer isolated from mains or line power. le the circuit is energized. CAUTION NOTE: Any kind of service or maintenance performed while During unit installation, is energized care must will void be taken the warranty. so that components on the printed rinted circuit circuit board board are are not not damaged. damaged. Catalog Hazardous Temp. Number Locations Code W2H840-4T Class I, Div. 2, Groups A, B, C, D T4 (135C) W2H620-4T Class II, Div. 2, Groups F, G T5 (100C) Class III, Div. 1 and 2 The tone programmed on SW1 overrides the tones programmed on SW2, SW3, and SW4. The tone on SW2 overrides the tones programmed on SW3 and SW4. Likewise, the tone on SW3 overrides the tone programmed on SW4. The tone programmed on SW4 has the lowest priority and cannot override any other programmed tone. Speaker direction and the output level are easily adjustable. Mechanical Specifications Weight... 9 Pounds (4.1 kg) Hazardous Locations, UL Standard UL1604 Ambient Temp.... +41F to +104F (+5C to +40C) Non-Hazardous Locations Variable Ambient Temp.... -40F to +151F (-40C to +66C) Hazardous Locations and Variable Ambient Conditions apply only where UL listings are accepted. To prevent fire, shock and component damage, NO work, including circuit board removal, should be performed while the circuit is energized. NOTE: Any kind of service or maintenance performed while unit is energized will void the warranty. 1. Mount signaling device as shown in Figure 2. a. Flat Surface Mounting. Secure unit to mounting surface using the (4) mounting holes in the mounting plate on the rear of the box. Use the #10 x 3" (76 mm) wood screws (furnished loose) or other hardware (not supplied) suitable for the mounting surface. b. Rigid Pipe Mounting. Loosen the (4) cover screws from the signal box and lift off signal box cover. NOTE: Cover screws are captive. Do not remove from cover. Remove the center knockout in lower wall of box and mount box to a 1/2" (12.7 mm) conduit pipe using suitable connector. P/N 3101170 ISSUE 1 2003

Table 1. Programming Logic Controller (PLC) Compatibility: PLC output to meet following product input parameters. See Figures 10 and 12 Operating voltage Max. off state Continuous on current Surge (inrush/duration) Cat. No. (Volts*) leakage current (ma) (ma) (Amps/milliseconds) W2H840-4T 24V DC only 2 740 8/4 W2H620-4T 120V 60 Hz 5 380 2.82/4 Input Board Circuit 24V DC 2 6 -- Input Board Circuit 120V 60 Hz 5 13 -- 2. Install wires through a knockout hole in the bottom of the box from a raceway that is, with its connections to the 1/2" (12.7 mm) conduit knockout hole, approved for the same degree of protection and enclosure type needed by the application. Use the provided plastic tie-wrap, on the barrier to the electronics, to separate incoming power leads from signal and tone initiating leads, per NEC (Figure 3). To prevent fire and shock, wire the signaling device only as described in this installation instruction. 3. Wire as follows referring to Figure 3. If Edwards Signal Actuator catalog number 5538-4 is used to manually initiate tones, connect its four normally-open switches to the Tone Generator as shown on instructions provided with the Signal Actuator unit. a. Connect green and yellow striped earth-ground wires to earth-ground. b. Select the appropriate method of wiring to the input board from Figures 5-9 for models with 24V input boards and Figures 10-12 for models with 120V input board. Connect the Adaptatone as shown. c. Connect incoming power to wire leads using a butt splice or other method listed, certified, or otherwise approved by local authorities. Leads are both black for -AQ and -N5 models and are black for line and white for neutral for -Y6 models. d. Optional. Connect external 24V DC battery (not supplied) in series with separate diode assembly part 2600010 (supplied) to TB1 terminals 3 and 4 on the main board as shown in Figure 4 and marked on the diode assembly. NOTE: Terminal Block TB1 can be unplugged from the main board to complete wiring as shown in Figure 5. 4. Refer to Figures 12 and 13 and select desired tones. Set miniature programming switches on the input board. For input connected to IN1, set on SW1; IN2, set on SW2; IN3, set on SW3, and IN4, set on SW4, in order of priority desired. S HIGH VOLTAGE is present when product is energized. High volume may cause harm to personnel in close proximity. 5. Adjust volume level, if desired, by turning potentiometer located on the main board (Figure 12). (4) #10 x 3" (76 mm) screws or other hardware suitable for the mounting surface To ensure integrity of the enclosure: Ensure the cover gasket, part number P-007549-0069, is adhered into groove at cover perimeter before replacing the signal box cover. Ensure that the (4) collar gaskets, part number P-041930-0362, are in place on each cover screw before securing the signal box cover. When securing cover, start screws by hand, making sure they are threaded into tapped holes in housing bosses before securing with a screwdriver. Torque signal box cover screws to a minimum of 20 in-lbs. This ensures the required tight fit. 6. Tightly secure the signal box cover using (4) retained cover screws. 7. Torque signal box cover screws to a minimum of 20 inlbs. Retighten nut and turn speaker slightly clockwise until locked into place. To ensure integrity of the Adaptatone assembly when adjusting the speaker direction, make sure threads in the enclosure remain fully engaged and do not turn speaker more than 360 degrees from the original factory installed position. Speaker Large star nut to adjust speaker direction Signal Box Figure 2. Mounting (4) Cover screws (4) Collar gaskets Raceway and connections (not supplied) to 1/2" (12.7 mm) knockout hole Page 2

8. To adjust speaker direction, loosen large star nut (Figure 2) and turn speaker to the approximate desired position. 9. Regardless of speaker direction adjustment, it is important that the star nut be tightened wrench tight to ensure the speaker position is maintained securely To ensure integrity of the horn assembly, prior to completion of installation, make sure threads in the enclosure are fully engaged and ensure that the star nut is wrench tight. 10. Verify operability. Maintenance and Test est Factory wired to speaker. To prevent fire, shock and component damage, NO work, including circuit board removal, should be performed while the circuit is energized. NOTE: Any kind of service or maintenance performed while unit is energized will void the warranty. Examine the unit semi-annually for accumulation of dirt. Clean if necessary. The Adaptatone should be tested annually or as required by the authority having jurisdiction to ensure continuous service. High volume may cause harm to personnel in close proximity. Power and earth-ground leads--black and white or black for power; yellow striped green for earth-ground. Plastic tie-wrap (provided)-- use to separate power leads from signal and tone initiating leads Figure 3. Wiring the W2H Signal/Tone initiating leads to be connected to Input Board Main Board 1 2 3 4 Terminal Block TB-1 (-) Wiring is factory installed to internal power supply (+) 2 4 1 3 TB1 (-) (+) Diode Assembly 2600010 To optional 24V DC Battery Backup Figure 4. Wiring to Tone Generator Terminal Blocks Page 3

ON INPUT BOARD ON INPUT BOARD K4 K4 K3 K3 K2 K2 K1 K1 Figure 5. Installing with Multiple Dry Relay Contacts to 24V Input Board Method 1 (Refer to Applications Engineering for compatibility with earlier versions of Adaptatone) Figure 6. Installing with Multiple Dry Relay Contacts Method 2, 24V Input Board ON INPUT BOARD CUSTOMER CIRCUIT (5V DC to 24V DC +/- 1%) FROM CUSTOMER CIRCUIT Figure 7. Installing with an Open Collector Transistor, 24V Input Board W2H840-4T, W2H620-4T Figure 8. Connecting to a "B" version Adaptatone, 24V Input Board (Maximum 5 W2H versions) Input Board PLC VDC 1 +24V DC (EXTERNAL POWER SOURCE) OUT 0 OUT 1 OUT 2 OUT 3 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 DC COM Figure 9. Connecting 24V Input Board to a PLC, See Table 1. 24 Volt Input Board Wiring Methods Page 4

ON INPUT BOARD K4 K3 K2 K1 LINE NEUTRAL 120V AC Figure 10. Installing with Multiple Dry Contacts, 120V Input Board ON INPUT BOARD PLC VAC 1 L1 120V AC (AC-HOT) OUT 0 OUT 1 OUT 2 OUT 3 VAC 2 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 TO PLC AC COM Figure 11 Connecting from a PLC to Input Board, 120V Input Board, See Table 1 Page 5 120 Volt Input Board Wiring Methods

INPUT BOARD N +VSGND IN4 SW1 SW2 SW3 SW4 PROGRAMMING SWITCHES (ON OTHER SIDE) PROCESSOR BOARD IN1 IN2IN3 MAIN BOARD POTENTIOMETER FOR VOLUME ADJUSTMENT Figure 12. PC Board Locations Page 6

Figure 13. Tone Programming Switch Tone Description 1 2 3 4 5 HEX No Tone 00 Ding-Dong Percussive pairs of 700 and 570 Hz tones, each damped to zero 01 Warble 575 and 770 Hz alternately, 87 ms each 02 Siren 600-1250 Hz up and down sweep in 8 seconds and repeat 03 Stutter Percussive 470 Hz, 83 ms on, 109 ms off 04 Slow Whoop 600-1250 Hz upward sweep in 4 seconds and repeat 05 Beep 470 Hz, 0.55 seconds on, 0.55 seconds off 06 Chime 1 700 Hz percussive repeat at 1 Hz 07 Fast Whoop 600-1250 Hz upward sweep in 1 second and repeat 08 Hi/Lo 780 to 600 Hz alternately, 0.52 seconds each 09 Rapid Siren 600-1250 Hz up and down sweep in 0.25 seconds and repeat 0A Yeow 1250-600 Hz downward sweep in 1.6 seconds and repeat 0B Horn 470 Hz continuous 0C Air Horn 370 Hz continuous 0D Dual Tone 450-500 Hz, 0.4 to 0.5 second cycle 0E Chime 2 575 Hz percussive repeat at 1 Hz 0F Westminster Two measures, 411 Hz, 520 Hz, 407 Hz, 312 Hz 10 Three Blind Mice Four measures, 787 Hz, 714 Hz, 625 Hz, 952 Hz, 333 Hz 11 Phasor 416-625 Hz up and down sweep in 13 ms and repeat 12 Telephone 570 and 770 Hz alternately, 50 ms each for 1.2s, 1.5s delay and repeat 13 Staircase 440-2000 Hz up and down steps, 750 ms delay and repeat 14 3 Tone Alert 463, 641 and 896 Hz, 200 ms each, 1 second delay and repeat 15 Presignal Chime 470 Hz percussive repeat at 1.5 Hz, followed by Message 1 16 Message 1 Field recorded voice message 17 Message 2 Field recorded voice message 18 Message 3 Field recorded voice message 19 Message 4 Field recorded voice message 1A NFPA Whoop Three 422-775 Hz upward sweeps, 850 ms each, 1s delay and repeat 1B 3 Pulse Horn 470 Hz, 3 0.5 second pulses separated by 0.5 seconds followed 1C by a 1.5 second delay and repeat--for Evacuation Use Only 3 Pulse Air Horn 370 Hz, 3 0.5 second pulses separated by 0.5 seconds followed 1D by a 1.5 second delay and repeat--for Evacuation Use Only 3 Pulse Dual Tone 450-500 Hz, 0.4 to 0.5 second cycle, 3 0.5 second pulses separated 1E by 0.5 seconds followed by a 1.5 second delay and repeat--for Evacuation Use Only 3 Pulse Chime 2 575 Hz, 3 0.5 second pulses separated by 0.5 seconds followed 1F by a 1.5 second delay and repeat--for Evacuation Use Only CAUTION The use of evacuation signals on this product, that is not specifically Listed for Fire Alarm Use, is subject to the approval of the Authority Having Jurisdiction. Page 7

P/N 3101170 OFFSET SPEC INSTALLATION INSTRUCTIONS FOR CATALOG SERIES W2H840-4T, W2H620-4T ADAPTATONE. (2) 11" X 17" SHEET PRINTED BOTH SIDES. SADDLE STITCHED IN 2 PLACES, COLLATED AND FOLDED IN HALF. MATERIAL: STANDARD WHITE OFFSET STOCK CHARACTERS: TO BE BLACK ON WHITE BACK- GROUND NOTE: MECHANICALS HAVE ALREADY BEEN REDUCED TO ACTUAL SIZE. RETURN MECHANICAL TO: TECHNICAL WRITING EDWARDS SIGNALING 90 FIELDSTONE COURT CHESHIRE, CT 06410 ECN: 06-C1796 FILE: 3101170 ISSUE: 01 APPROVED: AA P/N 3101170 FOLD DETAIL REFERENCE ONLY