2251TLE PRODUCT SPECIFICATION

Similar documents
200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION

ECO N DATE DESCRIPTION OF CHANGE CHG

S TEM PRODUCT SPECIFICATION

ECO N DATE DESCRIPTION OF CHANGE CHG

Barrier. ED /07/09 Release to production R.P. A ECO N DATE DESCRIPTION OF CHANGE CHG By ISSUE TITLE TC842B1007 AE PRODUCT SPECIFICATION

FlameGard 5 UV/IR HART

Consultant Specification AGILE Wireless Fire Detection System

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

The supplier and installer of the system should be approved by the local civil defence authority.

RS485 Integrators Guide

The new detector from Rafiki

Multi-Point Peripherals

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Analogue Detectors. Series 200 plus

TrueAlarm Smoke Detectors

OVEN INDUSTRIES, INC.

Installer Manual KNX Touchscreen Thermostat

FAAST LT SET-UP AND TROUBLESHOOTING GUIDE. CONTENTS Introduction...1 Wiring up a FAAST LT unit...1. Setting the Fan speed...7

TrueAlarm Analog Sensing

FlameGard 5 MSIR HART

Guidance Note. Fire Alarm Detector Applications and Documentation of the Selection

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

FIRERAY 5000 range USER GUIDE

Ethernet General Purpose

TrueAlarm ES Analog Sensing

RMS-I-DE-01 Smoke Detector

LaserFOCUS VLF-250 Engineering Specification

Conventional Detectors

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

General Purpose IO Technical Manual

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

COCB_ Circuit Breaker (2 state inputs/ 2 control inputs)

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

Installation and Operation Manual

200i/KN2, KN4 Firmware Revision Sheet

Basic Vehicle Fire Protection Manual

Open-area Smoke Imaging Detection (OSID)

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

PARAGON PLUS USER INSTRUCTIONS USER INSTRUCTIONS J?>5 J?>5 J?>5 J?>5 J?>5 J?>5 B??=

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

ZONE PANEL KIT INSTALLATION MANUAL COMMUNICATING ZONE PANEL KIT - (S1-TCZCB01A) ZONE PANEL WITH ZONING TOUCH SCREEN FIRMWARE

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Fire & Security Products. Siemens Building Technologies Group

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION

Description (Data Point Name) Unit Size

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

TrueAlarm Analog Sensing

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

ALK-V PHOTOELECTRIC SMOKE SENSOR

Evolution Analogue Addressable Fire System

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Multi-Point Peripherals

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

E3M-V. Mark Sensor. Applications

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

OH110, OP110, HI110 Automatic fire detectors

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

SACE PR021/K SIGNALLING UNIT

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

Security System. User Guide for the LED Command Center

Cerberus FIT conventional system

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Smoke Alarm User s Manual

IDS816 User Manual H Issued January 2009

Advanced DIGITAL Wired PIR Motion Detector

For Raychem ACS-30 Controls Systems

Conventional Fire Alarm System 2014 V1.2

How K-Patents DD-23 System is Built to Conform to BLRBAC Recommendations

Version 1.03 January-2002 USER S MANUAL

LUFKIN WELL MANAGER MODBUS MAP

Carbon Monoxide Transmitter

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Database for CTS6000 MODBUS

RESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize)

ID2000. operating manual

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Laser Technology Smoke Detector

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

SOLO Single Loop Addressable Fire Control Panel

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Pre-programmed room controller with communication

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Quick Installation Manual LED 99-Zone Autodial Wireless Alarm System

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Touchpad Exit Controller Administration Guide

Contents. Glossary

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Transcription:

DESRIPTION: This product is a multi-criteria sensor incorporating 3 separate sensing elements. An IR photo diode for measuring ambient IR light levels (welding probability as well as signatures from flame), a photo electric sensing chamber for measuring smoke products of combustion and two thermistors on opposite sides of the sensor to monitor for heat. It is mechanically and electrically compatible with the existing 500 Series intelligent system, and works correctly when installed in a 200/500 Series system. The same product can be factory programmed to work in an Enhanced protocol system as well. Please refer to the Reference Table below for details regarding 500 Series, Advanced and Enhanced protocol. The product in its 500 series compatibility mode operates in a similar way to the multicriteria photo/thermal sensor regarding its decision levels. It can be factory programmed to use the same type code as the photo/thermal or a different type code, depending on the requirements of the customer. While maintaining backward compatibility, the Advanced protocol provides expanded capabilities, including bi-directional digital communication, the possibility to address up to 159 sensors, interrupt feature, group polling format for fast response to alarm conditions and improved power delivery. The tens digits go from 0 to 15 and the units from 0 to 9. The decimal address corresponding to each code switch knob address configuration can be calculated by multiplying the tens by ten and adding the units to the result. The remote output and internal LED can be controlled separately either by 500 Series (see Separate operation of remote output paragraph) or advanced protocol commands. ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 1:28

The Advanced protocol defines two modes of communication, designated Direct Poll and Group Poll: these two modes communicate either with one device at a time or simultaneously with a group of devices. This protocol contains a rapid alarm or fault detection feature which enables any device to signal the control panel when the device detects an alarm or fault condition. The alarm/fault condition represents a condition in the device which has been defined to require attention from the panel. This signal can be generated by any device where an alarm or fault condition occurs. This feature is disabled by default, but can be enabled by special commands. The external EEPROM can be read or written to by means of advanced protocol commands. Not all of the bytes are read and/or write accessible through the 200 series Advanced protocol (refer to EEPROM contents table). Four bytes in the EEPROM are used as a serial number, which can be read at panel start-up to detect double addresses. The digital units corresponding to PW4 and PW6 PW9 are multiples of 16 microseconds, i.e. 800 s corresponds to 50 digital units, or 2400 s to 150 digital units (for a device with 300 s time base). The detector includes a new (compared to mask 4 photo/thermal sensors) drift compensation algorithm in the photoelectric chamber to last longer without cleaning. When drift compensation has reached its limit (Drift Limit) a unique signal is generated in PW4 signifying this state. Until this value is reached, the PW4 value will increase steadily from the nominal initial value towards the drift alarm value, so that the user can readily see the status of the photo chamber. The unprocessed raw photo chamber value can be available in PW6 (see fig.4) corresponding to the data range shown in the Drift ompensation onstants table, without the internal processing. The same data can be read by the panel through appropriate advanced protocol commands. ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 2:28

Magnet test generates an alarm (level 5 or level 6) unless the device determines it is incapable of alarming (photo, thermistor, IR fault). The device will then enter an algorithm bypass mode for the next 10 minutes: all delays/filters on the optical processing are temporarily removed. At this time the processing of the signal is limited so that canned smoke can easily and quickly cause an alarm signal, enabling easier verification of the multicriteria sensor s operation. After 10 minutes the device returns to its normal operation. There is a provision for determining whether an alarm is due to heat (Level 6). This allows the control panel to ignore smoke alarms during periods of time while still offering some level of detection. In 500 series protocol, a unique sequence of control commands is required to enable this option in the detector. To enable Level 6, the control panel needs to communicate to the device once with control bits 10 and 12 set to 00 followed by a single communication with control bits 10 and 12 set to 01, respectively. In 500 series protocol, once enabled, Level 6 can be disabled by repeating the above sequence. When enabled, PW2 will be three times PW1 for a single communication. When disabled, PW2 will be four times PW1 for a single communication. The status of the thermal alarm provision will be stored in EEPROM therefore the panel will not need to reconfigure the device after power loss. Enabling this function will also enable a second maintenance alert level when the photoelectric sensor s drift compensation has reached 80% of its limit. In this case a unique signal will be given in PW4/sub-address 0. When Level 6 is enabled the magnet test alarm level is level 6. In 200 series advanced protocol, level 6 and 80% drift alert are enabled by factory default. In 500 series protocol, the sensor can provide the panel with the highest instantaneous value of the two thermistors. This is given by PW7 according to the following formula: PW7 = (T + 87) x 8 (see Figure 5), where T is the highest temperature (elsius degrees) of the thermistors and units are microseconds. For example at 25, PW7 is about 896 s. This feature is factory programmable only. In 200 series advanced, the two thermistor values are available in subaddress 2 and 3. The temperature of the environment can be quite different from the temperature detected by the thermistors, due to thermal lag. ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 3:28

The sensor provides an ambient IR level proportional output on PW9/sub-address 4 (see Fig.7). The sensor has wide light dynamic capability thanks to an Automatic Gain ontrol circuit which is suitable for most environment/light levels. Direct sun light ( such as mirror reflection) or strong IR light sources directed towards the detectors might saturate the IR sensor. There is a value in PW4/sub-address 0 to indicate a light saturation condition. A fault will also be indicated after the predetermined time indicated in the specification. The transmission of PW6, PW7, and PW9 is determined by a setting in EEPROM. If the relevant bit is set, then all 3 PWs can be sent, if the bit is not set, then none of these PWs are sent. ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 4:28

SENSITIVITY AND NUISANE IMMUNITY The product provides 6 levels of sensitivity, which are categorized as below: Level 1 1%/ft of smoke. No delays from processed photo output. Level 2 2%/ft of smoke. No delays from processed photo output. Level 3 3%/ft of smoke. Time elapsed from smoke detection is within 1 30. Level 4 3%/ft of smoke. Time elapsed from smoke detection is between 1 30 and 3 00. Level 5 3%/ft of smoke. Time elapsed from smoke detection is greater than 3 00. Level 6 Heat only alarm. If the heat level on either thermistor exceeds 60 or rate of rise limits. Note: the delay counter starts when the smoke level exceeds approximately 0.75%/ft. The panel threshold should be chosen according to the specific environment: ULTRA-LEAN environments can use Level 1 ALERT LEAN environments can use Levels 2-3 ALARM MODERATE environments can use Level 4 ALARM HARSH environments can use Level 5-6 ALARM ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 5:28

When advanced protocol is used an application suitable for different harsh environments may be selected according to the following application table: Application Environment description Possible nuisance Problem Suggested Panel Advanced application download effect number threshold ALARM 0 Hotel bedroom near shower Steam and rate of rise in heat from opening bathroom door causing alarm. Detector installed close to Level 4 removes heat enhancement so delays applied before alarm and reduces thermal ROR alarm slightly. bathroom door. 0 Boiler rooms Dust and rate of rise heat causing false alarms. Level 4 removes heat enhancement so delays applied before alarm and reduces thermal ROR slightly Student dormitories, smoke from small appliance cooking Level 5 raises smoke threshold to medium 1 smoking hotel rooms or cigarette/etc. 2 Insect alarms Photo sensor only alarm. Level 5 raises smoke threshold to maximum 2 ondensation in attics (and other normally unheated spaces e.g. pump houses, service intake rooms etc) Photo sensor only alarm. Level 5 2 Heavy manufacturing Alarm from photo sensor due to dust/dirt. This application may include welding. 2 Strobes in industrial areas Alarm from photo sensor due to light dazzling and may include welding. Level 5 Level 4 raises smoke threshold to maximum raises smoke threshold to maximum raises smoke threshold to maximum 3 Dusty environments and Settled dust turbulence in the chamber before drift alarm reached 3 AHU rooms & lift motor rooms Synthetic smoke in 4 Discotheques and dazzling lights from strobes Photo sensor only alarm. Level 5 Alarm form photo sensor due to dust burst. Photo sensor alarm. an compromise drift compensation. May also include smoking cigarettes. Level 5 Level 5 raises smoke threshold to medium raises smoke threshold to medium raises smoke threshold to maximum ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 6:28

4 Bar Areas Alarm from photo sensor due to steam from glass washers and cigarette smoke. 4 Smoking area Alarm from photo due to 5 ar parks and loading bay with trucks having upward exhaust pipes or poor operating engines. Includes traffic build-up in cities. 5 Kitchens including industrial, canteens, and retirement homes. 6 Paint shops and repair shops cigarettes/etc. Alarm from photo and rate of rise heat sensors. Alarm from photo from burning foods and rate of rise sensors due to opening oven doors or turning ON burners. Alarm from photo and rate of rise sensors. This application may include welding and vehicles running inside building. 255 Vacuum cleaning Dust causing photo sensor only alarm. Level 5 Level 5 Level 5 Level 5 Level 5 Level 4 raises smoke threshold to maximum raises smoke threshold to maximum removes heat enhancement, changes thermal to fixed, and raises smoke to maximum removes heat enhancement, changes thermal to fixed, and raises smoke to maximum reduces heat enhancement in half and raises smoke threshold to maximum Default configuration: no effect ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 7:28

SEPARATE OPERATION OF REMOTE OUTPUT This feature is enabled by a global command to a non-existent address 253. With this global command, if all control bits are set to 0, then the detector accepts the command and redefines the action of the control bits on its normal polls, so that the LED and remote output can be separately controlled. If the control bits are all 1, then the device reverts to the standard LED control method. For only the next poll afterwards to any device that has seen and accepted this global command, PW2 will be 6xPW1 indicating that the remote output and LED are able to be separately controlled. When set to the standard LED control method, PW2 remains at 1xPW1. After the remote output on command is first given, during the same poll, PW2 is 5xPW1. The priority of each of the different PWs where applicable and where they might be given simultaneously or in such a way to be contradictory are as follows: Highest 3xPW1-4xPW1-5xPW1-6xPW1-2xPW1-1xPW1 Lowest The status of the redefinition is lost when the device is powered off. On power up reset, the device goes to the standard LED control method. All three control bits (10, 11 and 12) are used for controlling the LEDs when they are in the separately controllable state. The generation of PW5 on sensors is normally controlled by control bit 11, but in this mode, PW5 is always transmitted during the PW5 window. The possible combinations of control sequence are as follows: B10 B11 B12 LED Remote Remote Test output 0 0 0 ON ON# ON 0 0 1 ON ON# No hange 0 1 0 ON OFF@ ON 0 1 1 ON OFF@ No hange 1 0 0 OFF ON# No hange 1 0 1 BLINK ON# OFF 1 1 0 OFF OFF@ No hange 1 1 1 BLINK BLINK OFF This change of state requires two consecutive polls. @ This change of state requires two consecutive polls of remote output off # This change of state requires two consecutive polls of remote output on ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 8:28

VISIBILITY OF DRIFT OMPENSATION The multicriteria sensor provides the ability to last longer without cleaning by means of a drift compensation algorithm, which is based on the average photo chamber level compared with the current photo chamber level. In clean air, PW4/sub-address 0 reflects the drift compensation status, with 800 s for 0%, and 1200 s for 100%. The equivalent drift compensation range is in the 1.5 %/ft range. This means that the PW4/subaddress 0 value rises according to the amount of long-term chamber contamination until either the 80% drift level is reached, if this feature is enabled or until the 100% drift level is reached. While the detector is operating within the drift compensation range, its sensitivity to smoke is maintained. hanges in smoke level are not seen unless they are greater than the drift limit, ensuring that PW4/sub-address 0 values within the drift compensation range can never occur due to smoke. When the detector has reached or exceeded the 100% drift compensation range, the sensitivity to smoke will increase steadily as the chamber becomes more contaminated. TERMINAL LAYOUT Refer to Intelligent Base Product Spec. S00-003-XX ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 9:28

OMMUNIATION SPEIFIATIONS SPEIFIATION TYP MIN MAX UNIT OMMENTS ms Data Bit High Voltage Range (1) 5.0 4.5 5.5 V Recommended Panel Design Range Data Bit Low Voltage Range (1) 0 0.5 V Recommended Panel Design Range Bit Interval high Time (24V) 250 2000 s Bits 1-13: See Figure 1 Bit Interval low Time (0V, 5V) 250 2000 s Bits 1-13: See Figure 1 Software Reset Time 2750 2500 3000 s Minimum time to reset device (Figure 1) EEPROM write extended software reset time 1) All specifications refer to conditions at the detector head 4500 s Advanced protocol only (see Figure 2) 250 ms Advanced protocol only (see Figure 2) ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 10:28

ELETRIAL SPEIFIATIONS SPEIFIATION TYP MIN MAX UNITS OMMENTS ommunication Line Supply Range 24 15 32 V D Panel Voltage Output Driver urrent (I f ) 58 40 70 ma See Figure 3 Initial Output Driver urrent (I o ) 160 85 260 ma See Figure 3 Output Driver Transition Time 55 30 170 s See Figure 3 Standby urrent @ 24VD Supply 200 A No ommunication Standby urrent @ 24VD Supply 300 A ommunication with LED blink enabled, once every 5s Standby urrent @ 24VD Supply 250 ua Group poll with LED blink enabled, once every 0.1s LED urrent @ 24VD Supply 7 ma ontinuous Operation urrent Supply Voltage to Guarantee LED on 16.5 V Initial Power Up Time 3 s Reset Time 4 6 s @24V, led off, no comm. Power Up urrent @ 24VD Supply 400 ua Added, for 3s max (due to EEPROM read) Remote Output Voltage @ 24VD Supply 22.5 V Remote Output urrent @ 24VD Supply 10.8 ma PW4 Stabilization Time 2 s Entering/Exiting Test Mode Sensor Update Frequency 5 4 6 s Photo chamber sampling time ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 11:28

DRIFT OMPENSATION ONSTANTS (PW1 = 300us) lean Air Value 480 Drift Limit 1120 80% Drift Limit (if function enabled) 992 Note: These constants are unprocessed raw chamber values available only from PW6/sub-address 1 when this feature is factory enabled. All the limits are microseconds. ENVIRONMENTAL SPEIFIATIONS SPEIFIATION TYP MIN MAX UNITS OMMENTS Humidity 15 90 % RH Temperature -30 60 Limits imposed from wax melting Air Velocity Pressure SENSITIVITY SPEIFIATIONS SPEIFIATION PRINT REFERENE. Range OMMENTS Smoke limits S61-179-XX Photo Static temperature limits S61-105-XX Thermal TYPIAL MEASURABLE RANGE SPEIFIATION RANGE UNITS OMMENTS IR limits 0-450 uw/cm² Irradiance on IR sensor ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 12:28

WAVEFORM MEANINGS 3 BIT DEFINITIONS SENSOR PW DEFINITIONS BIT 1 SENSOR/MODULE SELET PW1 REFERENE BITS 2 5 HIGH ADDRESS ODE SWITH BITS PW2 REMOTE TEST STATUS BITS 6 9 LOW ADDRESS ODE SWITH BITS PW3 MANUFATURER ODE BITS 10 12 ONTROL BITS PW4 SENSITIVITY BIT 13 EVEN PARITY BIT PW5 TYPE IDENTIFIATION PW6 PW7 RAW HAMBER VALUE (IF ENABLED) HIGHEST TEMPERATURE VALUE (IF ENABLED) PW8 SET TO 0 3) See Figure 1 PW9 RAW IR SENSOR VALUE (IF ENABLED) PW LIMITS (PW1 = 300 s) ABSOLUTE LIMITS (due to environmental/aging effects) MIN TYP MAX PW1 285 300 315 PW2 285 300 315 PW2 (RemoteTest) 570 600 630 PW2 (Level 6 enabled) 855 900 945 PW2 (Level 6 disabled) 1140 1200 1260 ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 13:28

PW2(Separate remote output control disabled) 1425 1500 1575 PW2(Separate remote output control enabled) 1710 1800 1890 PW3 (OEM code 570 600 630 PW4 (Normal, clean) 760 800 840 PW4 (Low hamber Trouble / Thermistor trouble/ir self test failure/freeze alert ) 140 150 160 PW4 (Maintenance Urgent / Drift Limit) 285 300 315 PW4 (Maintenance Alert: 80% drift limit OR continuous IR saturation condition) 425 450 475 PW4 (IR light saturation condition) 665 700 735 PW4 99% drift (80% drift limit disabled) 1140 1200 1260 PW4 (Alarm 1) 1%/ft no delays- 1330 1400 1470 PW4 (Alarm 2) 2%/ft no delays. 1710 1800 1890 PW4 (Alarm 3) 3 %/ft no delays. 2090 2200 2310 PW4 (Alarm 4) 3%/ft with 1.5 min delay. 2470 2600 2730 PW4 (Alarm 5) 3%/ft with 3 min delay. 2850 3000 3150 PW4 (Alarm 6 Heat / Magnet Test) * 3230 3400 3570 PW4 (Remote Test / Magnet Test) 2850 3000 3150 PW5 (Type ID) 1995 2100 2205 PW6 (Raw photo sensor value) 370 480 610 PW7 (Heat levels) @ 25-900 - ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 14:28

PW9 (IR level) 0-4920 * If level 6 is enabled If extended PWs are enabled. Note: All the limits are microseconds REFERENE TABLE DRAWING NO. S61-491-000 S61-432-000 S61-431-000 S00-003-xx 200 SERIES ADVANED PROTOOL DESIGN GUIDE 500 SERIES PROTOOL DESIGN GUIDE ENHANED PROTOOL DESIGN GUIDE INTEIGENT BASE PRODUT SPEIFIATION ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 15:28

ALARM TEST FEATURES APPLIABLE TEST METHODS OMMENTS Test Magnet Panel Remote Test Aerosol Heat Gun MEHANIAL SPEIFIATIONS SPEIFIATION TYP MIN MAX UNITS OMMENTS Wire Gauge for Screw Terminals Refer to intelligent base product spec. S00-003-XX Maximum Terminal Screw Torque Refer to intelligent base product spec. S00-003-XX Height 60 mm when used with a B501 base Length or Diameter 102 mm Weight 124 g ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 16:28

FIG. 1 - SERIAL OMMUNIATION WAVEFORM WITH QUANTITIES DEFINED Bit high Bit low Supply voltage 1 2 3 4 5 6 7 8 9 10 11 12 13 Data bit high Data bit low PW1 PW2 PW3 PW4 PW5 Bit interval Software Reset Time FIG. 2 - SERIAL OMMUNIATION WAVEFORM ADVANED PROTOOL 24V 5V 0V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 A H 3 A H 2 A H 1 A H 0 A L 3 A L 2 A L 1 A L 0 G 7 G 6 G 5 G 4 G 3 G 2 G 1 G 0 P A P E / A K A L A R M S/W Reset M 7 M 6 M 5 M 4 M 3 M 2 M 1 M 0 P A P E R R S/W Reset D B 7 D B 6 D B 5 D B 4 D B 3 D B 2 D B 1 D B 0 P A P E R R S/W Reset M/S 1111.1100 / 1111.1011 Group ode/address Even Parity ommand DB7 to PA will be held at 5V if devices are to respond Note: in group polling the parity error bit is not used in this version of product firmware ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 17:28

Io (ma) If (ma) I (ma) t (µs) Transition Time FIG. 3-50 ma OUTPUT DRIVER SIGNAING WAVEFORM FOR URRENT SINK ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 18:28

PW6 VS Light Transmission 200 180 160 140 120 100 usx16 min typ max 80 60 40 20 0 100 98 96 94 92 90 88 86 84 82 LT FIG. 4 - UNPROESSED PHOTO SENSOR VALUES ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 19:28

PWT=(T+87)X8 PW7(us) 1500 1400 1300 1200 1100 1000 900 800 700 600 500-20 -10 0 10 20 30 40 50 60 70 80 T( ) min typ max Fig. 5 - UNPROESSED THERMAL VALUE VS TEMPERATURE ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 20:28

Typical PW9 VS Irradiance us 5500 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0 0 100 200 300 400 500 600 Ie [uw/cm²] Ie typ Ie min Ie max Fig.6 UNPROESSED IR VALUES VS IRRADIANE [uw/cm²] ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 21:28

EEPROM ONTENTS INFORMATION LOATION READ FATORY PROGRAMMED VALUE Photo drift limit 10 Read 35 Photo factory clear air 12 Read Depends on calibration....... Firmware Revision 18 Read Revision number OEM Manufacturer ID 19 Read Depends on OEM Type ID 20 Read 32....... hecksum 31 Depends on EEPROM contents Photo current average 32 Read Depends on calibration Environment application number 38 Read/Write 255 LED control group code 41 Read/Write 0 Remote output control group code 42 Read/Write 0 Remote Test group code 43 Read/Write 0 Thermal alarm group code 44 Read/Write 0 Alarm Latch Limit 1 (Processed sensor value) 49 Read/Write 255 Alarm Latch Limit 2 (Processed sensor value) 50 Read/Write 255 Alarm Latch Limit 3 (Processed sensor value) 51 Read/Write 255 Alarm Latch Limit 4 (Processed sensor value) 52 Read/Write 255 Fault latch limit 1 (Processed sensor value) 53 Read/Write 255 Fault latch limit 2 (Processed sensor value) 54 Read/Write 255 Fault latch limit 3 (Processed sensor value) 55 Read/Write 255 Fault latch limit 4 (Processed sensor value) 56 Read/Write 255 Alarm Latch Limit 1 (Sensing element photo) 57 Read/Write 255 Alarm Latch Limit 2 (Sensing element photo) 58 Read/Write 255 Alarm Latch Limit 3 (Sensing element photo) 59 Read/Write 255 Alarm Latch Limit 4 (Sensing element photo) 60 Read/Write 255 ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 22:28

INFORMATION LOATION READ FATORY PROGRAMMED VALUE Fault latch limit 1 (Sensing element photo) 61 Read/Write 255 Fault latch limit 2 (Sensing element photo) 62 Read/Write 255 Fault latch limit 3 (Sensing element photo) 63 Read/Write 255 Fault latch limit 4 (Sensing element photo) 64 Read/Write 255 Alarm Latch Limit 1 (Sensing element thermal #1) 65 Read/Write 255 Alarm Latch Limit 2 (Sensing element thermal #1) 66 Read/Write 255 Alarm Latch Limit 3 (Sensing element thermal #1) 67 Read/Write 255 Alarm Latch Limit 4 (Sensing element thermal #1) 68 Read/Write 255 Fault latch limit 1 (Sensing element thermal #1) 69 Read/Write 255 Fault latch limit 2 (Sensing element thermal #1) 70 Read/Write 255 Fault latch limit 3 (Sensing element thermal #1) 71 Read/Write 255 Fault latch limit 4 (Sensing element thermal #1) 72 Read/Write 255 Alarm Latch Limit 1 (Sensing element thermal #2) 73 Read/Write 255 Alarm Latch Limit 2 (Sensing element thermal #2) 74 Read/Write 255 Alarm Latch Limit 3 (Sensing element thermal #2) 75 Read/Write 255 Alarm Latch Limit 4 (Sensing element thermal #2) 76 Read/Write 255 Fault latch limit 1 (Sensing element thermal #2) 77 Read/Write 255 Fault latch limit 2 (Sensing element thermal #2) 78 Read/Write 255 Fault latch limit 3 (Sensing element thermal #2) 79 Read/Write 255 Fault latch limit 4 (Sensing element thermal #2) 80 Read/Write 255 Alarm Latch Limit 1 (Sensing element IR) 81 Read/Write 255 Alarm Latch Limit 2 (Sensing element IR) 82 Read/Write 255 Alarm Latch Limit 3 (Sensing element IR) 83 Read/Write 255 Alarm Latch Limit 4 (Sensing element IR) 84 Read/Write 255 Fault latch limit 1 (Sensing element IR) 85 Read/Write 255 Fault latch limit 2 (Sensing element IR) 86 Read/Write 255 Fault latch limit 3 (Sensing element IR) 87 Read/Write 255 ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 23:28

INFORMATION LOATION READ FATORY PROGRAMMED VALUE Fault latch limit 4 (Sensing element IR) 88 Read/Write 255 User data byte 1 97 Read/Write 0 User data byte 2 98 Read/Write 0 User data byte 3 99 Read/Write 0 User data byte 4 100 Read/Write 0 User date byte 5 101 Read/Write 0 ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 24:28

SUB-ADDRESS LOATIONS PROESSED SENSOR VALUES VALUE MEANING DIRETION VALUE TYP 0 Processed value Input Low hamber Trouble / Thermistor trouble/ir self test failure/freeze alert 9 1 Photo sensor Input Maintenance Urgent / Drift Limit 19 2 Thermal 1 Input Maintenance Alert: 80% drift limit OR continuous IR saturation condition 28 3 Thermal 2 Input IR light saturation condition 44 4 IR Input Normal, clean 50 129 LED control Output 99% of drift range 75 130 Remote output control Output Alarm 1 1%/ft 87 131 Remote Test Output Alarm 2 2%/ft 112 132 Thermal alarm Output Alarm 3 3%/ft 137 Alarm 4 3%/ft delay 162 Remote Test / Magnet Test 187 Alarm 5 3%/ft delay 187 Alarm 6 Heat (FT or ROR) 212 Maximum smoke value 212 Internal Fault 254 Power up special value 255 ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 25:28

DIRET AND GROUP POING OMMANDS OMMAND FUNTION DATA/DIRETION DATA SUBADDRESS ID DESRIPTION 1 Set Outputs 1 byte/panel to device (2x) 0 129 Turn alarm LED Off 1 129 Pulse alarm LED on communication (Blinking) 2 129 Turn alarm LED On 3 129 Intermittent alarm LED on 4 129 Pulse Green LED on communication (Blinking) 5 129 Turn Green LED On 6 129 Intermittent Green LED On (where Green LED fitted) 0 130 Turn remote output Off 1 130 Pulse remote output on communication (Blinking) 2 130 Turn remote output On 3 130 Intermittent remote output on 0 131 Turn Remote Test Off 2 131 Turn Remote Test On 0 132 No heat alarms 1 132 Enable rate of rise alarm 2 132 Enable fixed temperature alarm 3 132 Enable rate of rise and fixed temperature alarm 2 Read Output Status 1 byte/device to panel 0 129 Alarm LED Off 1 129 Alarm LED pulsing on communication (Blinking) 2 129 Alarm LED On 3 129 Intermittent alarm LED on ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 26:28

OMMAND FUNTION DATA/DIRETION DATA SUBADDRESS ID DESRIPTION 2 Read Output Status (continued) 1 byte/device to panel 4 129 Green LED pulsing on communication (Blinking) 5 129 Green LED On 6 129 Intermittent Green LED On 129 (where Green LED not fitted) 0 130 Remote output Off 1 130 Remote output pulsing on communication (Blinking) 2 130 Remote output On 3 130 Intermittent remote output on 0 131 Remote Test Off 2 131 Remote Test On 0 132 No heat alarms 1 132 Rate of rise alarm enabled 2 132 Fixed temperature alarm enabled 3 132 Enable rate of rise and fixed temperature alarm 3 Load Group ode 1 byte/panel to device (2x) 0 255 129-132 (output) Set by panel, EEPROM value on Power On Reset 4 Reset Alarm Latch 1 byte/panel to device 0 255 0-5 Reset Interrupt Latch. A 1 in the relevant bit position determines which interrupt to reset. 5 Read Group ode 1 byte/device to panel (Default = 0) 0 255 129-132 (output) Transmit Group ode to Panel 8 Read Alarm/Fault Latch ondition Units 9 Read Alarm/Fault Latch ondition Tens 1 byte/panel to device 10 bits/device to panel 0 15 0 1023 NO Units with an interrupt corresponding to the tens address sink current in bits 0-9 (300 s defines fault, 600 s defines alarm) 2 bytes/device to panel 0 255 NO All units with an interrupt sink current in the relevant bit equal to their tens address within the relevant response byte (300 s ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 27:28

OMMAND FUNTION DATA/DIRETION DATA SUBADDRESS ID DESRIPTION defines fault, 600 s defines alarm) 10 Read Presence ondition 1 byte/panel to device 10 bits/device to panel 0 15 0 1023 NO All installed units with the corresponding tens address sink current in bits 0-9 in the relevant bit position. Note that on power on, there is no current sink until the Reset Power On command has been issued or this command is received 5 times 11 Write Alarm Latch Register 2 bytes/panel to device 0 255 0-5 onfigure Alarm Latch Register (00 off, 01 = high, 02 = low, 03 = high/low) 12 Read Alarm Latch Register 2 bytes/device to panel 0 255 0-5 Transmit Alarm Latch Register to Panel (Default = 0) 13 Read Sensor value 1 byte/device to panel 0 255 0-5 Transmit Sensing Element Raw Value. Note that on power on, the processed value is 255 until the Reset Power On command has been issued. 14 Read Multiple Device Input value 15 Read Address using Serial Number 16 Read Serial Number using Address 17 Disable Answer using Serial Number 18 Read EEPROM Data 3 bytes/panel to device N bytes/device to panel 19 Write EEPROM Data 3 bytes/panel to device N bytes/panel to device 5 bytes/device to panel 0 255 NO Transmit subsequently the processed and raw sensor values. Note that on power on, the processed value is 255 until the Reset Power On command has been issued. 4 bytes/panel to device $00.00.00.00 $FF.FF.FF.FF NO Transmit Address of factory programmed Serial Number 1 byte/device to panel 0 159 1 byte/panel to device 0 159 NO Transmit factory programmed Serial Number for device 4 bytes/device to panel $00.00.00.00 $FF.FF.FF.FF addressed. 4 bytes/panel to device $00.00.00.00 $FF.FF.FF.FF NO Disable any answer of factory programmed Serial Number, to Read Serial Number using Address command. Location: 0 65534 Length: 1 128 Data: 0 255 Location: 0 65534 Length: 1 128 Data: 0 255 NO NO Transmit contents of specified EEPROM locations Rewrite specified EEPROM locations by transmitted bytes in sequence starting at first location specified. 21 Reset Power On no data NO lear special value 255 given at power up 22 Read/Write EEPROM Result 1 byte/device to panel 0 1 NO Transmit result of last Read/Write EEPROM Data command 23 Reset Device no data NO Re-Write whole EEPROM to default values and initialize RAM variables ED2971.X +/-.XX +/-.XXX +/- HOLES +/- ANGLES +/- DO NOT 28:28