LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Similar documents
LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Operating Manual RCM420

LINETRAXX RCMS460-D/-L RCMS490-D/-L

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

RCMA423. Residual current monitor for monitoring AC-, DC- and pulsed DC currents in TN- and TT systems Software-Version: D330 V1.0x.

CMD420 / CMD421 Series

RCMA423-DM1C Residual current monitor

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Insulation fault evaluator EDS460-DG

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

1.7. Insulation fault evaluators EDS460/490 EDS461/491

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Operating Manual VMD420

Manual CME420. Multi-functional current relay, AC, overcurrent/undercurrent/ window discriminator function CME420_D00034_02_M_XXEN/05.

VME420 Voltage and frequency monitor

VME421H Voltage and frequency monitor

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Bender GmbH & Co. KG. All rights reserved. Reprinting only with permission of the publisher. Subject to change! Photos: Bender archives

Remote alarm indicator and test combination MK2430

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

LINETRAXX RCMS150. Residual current monitor type B with integrated measuring current transformers for earthed AC/DC systems (TN and TT systems)

TM800. Remote alarm indicator and operator panels

IT system floor-standing distribution

ISOMETER IRDH265 IRDH365

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

BENDER A-ISOMETER IRDH265 IRDH365

Operating Manual TR600

Line Isolation Monitor (LIM) LIM2000plus

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

T M LIM2010. Line Isolation Monitor (LIM) Technical Bulletin NAE /

Operating Manual MS220KA and MSR220KA

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

MK Series. Remote Indicators For Line Isolation Monitors and Fault Location. Technical Bulletin NAE /

Project planning (original) EN. Functional safety. Inverter i550-cabinet kw

Process Alarm Module RTA 421

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Parameterisable compact fault annunciator with permanent display

SCHMIDT LED Measured Value Display MD Instructions for Use

Product overview. Alarm indicator, operator and display panels

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Operation and use. Functions and characteristics

Operating Manual MSF220V(VU)

PolyGard 2-channel Gas Controller MGC-03

Universal fault annunciator for panel mounting

Multi-Gas-Controller MGC2

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Soft Starter Centrifugal Pump Soft Starter Series

REA 105 Arc Protection Module. Operator s Manual

Instructions for the fan motor control system with integrated wiring terminals SILVER C

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

AO Annunciator Module

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

DOCUMENTATION IPS640

DOCUMENTATION IPS640

CONTROL DEVICE SLIDETRONIC HD

T M. User Manual LIM2010. Line Isolation Monitor

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

ISIS SAFETY SYSTEM Installation guide

Operating Manual MS220DA

Oxygen (O2) Single-Point Gas Detection System

A-ISOMETER IRDH575. Operating Manual

INSTALLATION & USER MANUAL

ISOMETER IRDH375 IRDH375B

Radio fire warning panel SRC 3000

EasyTronic III MANUAL SERVICE

Monitoring Devices 11/1

Dräger PointGard 2100 Detection of toxic gases and vapours

LC1350 Level Controller

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Ordering Key. Dielectric strength

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

DICTATOR Hold-Open Systems for Hazardous Areas

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

RSGD. Three phase AC motor soft starter. Benefits. Description

DTA. Motor thermistor relay. Benefits. Description

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Transcription:

LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016

LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems Product description The AC/DC sensitive residual current monitor RCMA420 is designed for monitoring earthed power supply systems (TN and TT systems) where smooth DC fault currents or residual currents continuously greater than zero may occur. These are in particular loads containing six-pulse rectifiers or one way rectifiers with smoothing, such as converters, battery chargers, construction site equipment with frequency-controlled drives. Currents in single conductors can be monitored too. The prewarning stage (50 100 % of the set response value I Δn2) allow to distinguish between prewarning and alarm. Since the values are measured with measuring current transformers, the device is nearly independent of the load current and the nominal voltage of the system. LINETRAXX RCMA420 Device features AC/DC sensitive residual current monitor Type B acc. to IEC 62020 and IEC/TR 60755 r.m.s. value measurement (AC+DC) Two separately adjustable response values 10 500 ma Frequency range 0 2000 Hz Start-up delay, response delay and delay on release Digital measured value display via LC display Measured value memory for operating value CT connection monitoring LEDs: Power On, Alarm 1, Alarm 2 Internal/external test/reset button Two separate alarm relays (one changeover contact each) N/O or N/C operation and fault memory selectable Continuous self monitoring Multi-functional LC display Password protection for device settings Sealable transparent cover Two-module enclosure (36 mm) RoHS compliant Push-wire terminal (two terminals per connection) Applications AC/DC sensitive residual current monitoring in earthed two, three or four conductor systems (TN and TT systems) Monitoring of variable-speed drives, UPS systems, construction site equipment, printing machines, battery systems, laboratory equipment, wood working machines, MF welding systems, furniture industry, medical electrical equipment, etc. AC/DC sensitive current monitoring of, in the normal case, de-energised single conductors (e.g. N and PE conductors) Function Once the supply voltage U S is applied, the start-up delay is activated. Measured values changing during this time do not influence the switching state of the alarm relays. Residual current measurement takes place via an external measuring current transformer of the W20AB W60AB series. The currently measured value is shown on the LC display. In this way any changes, for example when circuits are connected to the system, can be recognised easily. If the measured value exceeds the set response values, the response delays t on1/2 begin. Once the response delay ton1/2 has elapsed, the K1/K2 alarm relays switch and the alarm LEDs AL1/AL2 light up. If the current falls below the release value (response value plus hysteresis), the release delay t off. When toff has elapsed, the alarm relays return to their initial position and the alarm LEDs AL1/AL2 go out. If the fault memory is activated, the alarm relays remain in the alarm state and the LEDs light until the reset button is pressed or until the supply voltage is interrupted. The device function can be tested using the test button. Parameters are assigned to the device via the LCD and the control buttons on the front panel; this function can be password-protected. Connection monitoring The function of the device and the CT connections are continuously monitored. In the event of a fault, the alarm relays K1/K2 switch without delay, the alarm LEDs AL1/AL2/ON flash. On removal of the fault, the alarm relays return to their initial position either automatically or by pressing the reset button. Approvals 2 RCMA420_D00059_01_D_XXEN/06.2016

Residual current monitor LINETRAXX RCMA420 Operating and display elements 1 2 3 Wiring diagram U S 4 2 1 5 1 - Power On LED ON (green); lights when supply voltage is applied and flashes in the event of system fault alarm respectively in the event of CT malfunction. 2 - Alarm LED AL1 (yellow), prewarning; lights when the set response value I Δn1 is exceeded or flashes in the event of system fault alarm respectively in the event of CT malfunction 3 - Alarm LED AL2 (yellow), alarm; lights when the set response value I Δn2 is exceeded or flashes in the event of system fault alarm respectively in the event of CT malfunction. 4 - Multi-functional LC display 6 7 5 - Test button T : to call up the self test. Arrow up button: parameter change, to move up in the menu 6 - Reset button R : to delete saved alarms. Arrow down button: parameter change, to move down in the menu 7 - MENU button: to call up the menu system. Enter button: to confirm parameter change. ESC button: press the button > 1.5 seconds. 5 1 - Supply voltage US see ordering information, 6 A fuse recommended 2 - Connector for the external W20AB W60AB series measuring current transformer 3 - Alarm relay K1 : I Δn1 (prewarning) 4 - Alarm relay K2 : alarm I Δn2 (alarm) 5 - Combined test and reset button T/R short-time pressing (< 1.5 s) = RESET long-time pressing (> 1.5 s) = TEST 3 4 Do not route the PE conductor through the measuring current transformer! RCMA420_D00059_01_D_XXEN/06.2016 3

Residual current monitor LINETRAXX RCMA420 Connection of measuring current transformers Dimension diagram XM420 I( n ) 500 ma I( n ) > 500 ma Dimensions in mm Open the front plate cover in direction of arrow! Screw mounting Note: The upper mounting clip must be ordered separately (see ordering information). 93 107 Ordering information Supply voltage 1) US AC DC Type Art. No. 16 72 V, 42 460 Hz 9.6 94 V RCMA420-D-1 B74043001 70 300 V, 42 460 Hz 70 300 V RCMA420-D-2 B74043002 Device version with screw terminals on request. 1) Absolute values Accessories Type designation Mounting clip for screw mounting (1 piece per device) Art. No. B98060008 Suitable system components Type designation Measuring current transformers Internal diameter (mm) Type Art. No ø 20 W20AB B98080008 ø 35 W35AB B98080016 ø 60 W60AB B98080026 Connection to the RCMA420 residual current monitor using the WX- connecting cable. Colour coding for WX : k = yellow, l = green, -12 V = black, GND = brown, +12 V = red, Test (T) = orange Type designation Length/m Type Art. No Connection cable measuring current transformer 1 WX-100 B98080503 2,5 WX-250 B98080504 5 WX-500 B98080505 10 WX-1000 B98080511 4 RCMA420_D00059_01_D_XXEN/06.2016

Residual current monitor LINETRAXX RCMA420 Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 RCMA420-D-1: Rated insulation voltage Rated impulse voltage/pollution degree Overvoltage category RCMA420-D-2: Rated insulation voltage Rated impulse voltage/pollution degree Overvoltage category Supply voltage 100 V 2,5 kv/3 III 250 V 4 kv/3 III RCMA420-D-1: Supply voltage range U S AC 24 60 V/DC 24 78 V Operating range U S AC 16 72 V/DC 9.6 94 V Frequency range U S DC, 42 460 Hz RCMA420-D-2: Supply voltage range U S AC/DC 100 250 V Operating range U S AC/DC 70 300 V Frequency range U S 42 460 Hz Protective separation (reinforced insulation) between (A1, A2) - (k/l, T/R) - (11, 12, 14) - (21, 22, 24) Voltage test according to IEC 61010-1 2.21 kv Power consumption 6,5 VA Measuring circuit External measuring current transformer W20AB, W35AB(P), W60AB(P) series Rated insulation voltage (measuring current transformer) 800 V Operating characteristic acc. to IEC 62020 and IEC/TR 60755 Type B Frequency range 0 2000 Hz Measuring range AC 0 1.5 A Measuring range DC 0 600 ma Relative uncertainty for f 2 Hz or 16 Hz 0-35 % Relative uncertainty for f >2 <16 Hz -35 +100 % Operating uncertainty 0 35% Response values Rated residual operating current I Δn1 (prewarning, AL1) 50 100 % x IΔn2, (50 %)* Rated residual operating current I Δn2 (Alarm, AL2) 10 500 ma (30 ma)* Hysteresis 10 25 % (15%)* Specified times Starting delay t Response delay t on2 (alarm) Response delay t on1 (prewarning) Delay on release t off Operating time t ae at I Δn = 1 x I Δn1/2 Operating time t ae at I Δn = 5 x I Δn1/2 Response time t an Recovery time t b Displays, memory Display range, measured value AC Display range, measured value DC Error of indication Measured-value memory for alarm value Password Fault memory alarm relay 0 10 s (0.5 s)* 0 10 s (0 s)* 0 10 s (1 s)* 0 99 s (1 s)* 180 ms 30 ms t an = t ae + t on1/2 300 ms 0 1.5 A 0 600 ma ±17.5 %/± 2 digit data record measured values off/0 999 (off)* on/off (on)* Inputs/outputs Cable length for external test/reset button Cable lengths for measuring current transformers Connection WX or alternatively: single wire 6 x 0.75 mm² Switching elements 0 10 m 1 m/2.5 m/5 m/10 m 0 10 m Number of switching elements 2 x 1 changeover contact Operating principle N/C operation/n/o operation (N/C operation)* Electrical service life under rated operating conditions 10000 switching operations Contact data acc. to IEC 60947-5-1 Utilization category AC-13 AC-14 DC-12 DC-12 DC-12 Rated operational voltage 230 V 230 V 24 V 110 V 220 V Rated operational voltage UL 200 V 200 V 24 V 110 V 200 V Rated operational current 5 A 3 A 1 A 0.2 A 0.1 A Minimum contact load 1 ma at AC/DC 10 V Environment/EMC EMC IEC 62020 Operating temperature -25 +55 ºC Classification of climatic conditions IEC 60721 Stationary use (IEC 60721-3-3) 3K5 (except condensation and formation of ice) Transportation (IEC 60721-3-2) 2K3 (except condensation and formation of ice) Storage (IEC 60721-3-1) 1K4 (except condensation and formation of ice) Classification of mechanical conditions acc. to IEC 60721: Stationary use (IEC 60721-3-3) 3M4 Transportation (IEC 60721-3-2) 2M2 Storage (IEC 60721-3-1) 1M3 Connection For UL applications: use 60 C/70 C copper conductors only Connection type Connection properties: Rigid Flexible without ferrules Flexible with ferrules Stripping length Opening force Test opening, diameter Other push-wire terminals 0.2 2.5 mm² (AWG 24 14) 0.75 2.5 mm² (AWG 19 14) 0.2 1.5 mm² (AWG 24 16) 10 mm 50 N 2.1 mm Operating mode continuous operation Position of normal use display-oriented Degree of protection, internal components (IEC 60529) IP30 Degree of protection, terminals (IEC 60529) IP20 Enclosure material polycarbonate Flammability class UL94V-0 DIN rail mounting acc. to IEC 60715 Screw fixing 2 x M4 with mounting clip Documentation number D00059 Weight 150 g ( )* = factory setting RCMA420_D00059_01_D_XXEN/06.2016 5

Bender GmbH & Co. KG P.O. Box 1161 35301 Gruenberg Germany Londorfer Strasse 65 35305 Gruenberg Germany Tel.: +49 6401 807-0 Fax: +49 6401 807-259 E-Mail: info@bender.de www.bender.de BENDER Group RCMA420_D00059_01_D_XXEN / 06.2016 / pdf / Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the version that was valid at the time of printing.