INSTALLATION GUIDE. soft duomatik evoline

Similar documents
INSTALLATION GUIDE. soft duomatik evoline

INSTALLATION GUIDE. soft monomatik hotwater

DUPLEX COMPACT. 11. CONNECTIONS (1/2",3/4, 1") BRINE VALVE 5. (floater)

1. BYPASS 7. WATER OUTLET 2. VALVE HOUSING 8. BLENDING REGULATOR 3. RESIN TANK 9. HARDNESS REGULATOR 4. SALT BIN 10.

1. BYPASS 7. WATER OUTLET 2. VALVE HOUSING 8. BLENDING REGULATOR 3. RESIN TANK 9. HARDNESS REGULATOR CONTAINER FOR 4.

Cabinet Non-Electric Water Softener

NOT EVERYTHING IN LIFE IS COMPLICATED.

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

BEFORE USING THE DISHWASHER/CONNECTIONS

O P E R A T I N G M A N U A L

What to expect from your water softener

Owner's Manual. WS Series. Water Softener

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

SHOWER SOFTENER-CEASA 1

GRANT-DILLING-HARRIS INC. WATER SOFTENER THEORY OF OPERATION

user manual Dishwasher ESL 46510

User manual. Dishwasher ZDTS102. Downloaded from manuals search engine

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

2020c WATER SOFTENER INSTALLATION INSTRUCTIONS. visit

FLECK 5600 WATER SOFTENER INSTALLATION

OptiSoft Softeners Simple Install Steps 1-17

HX-30/40 and HX-30/40 S Glass and Dishwashers

INSTALLATION AND QUICK COMMISSIONING INSTRUCTIONS EWC WARM WATER TIME CLOCK WATER SOFTENERS

Water Softener. Operating Manual

Glass and Dishwashers AMX / AUX Series

FAVORIT34502VIO. EN User Manual

This material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected.

FAVORIT VI DISHWASHER USER MANUAL

GETTING STARTED? EASY.

User manual. Dishwasher ZDI12001

GETTING STARTED? EASY.

Coffee Machine Zia series

Owner s Manual / 5600 Econominder

User manual. Dishwasher ZDT15002

Water Softener Installation Guide Effective for all Softeners from our Range

CER-1 & CER-2 Installation & Testing Instructions

FAVORIT DISHWASHER USER MANUAL

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL

Glass and Dishwashers AMX / AUX Series

Operating Manual. Reverse Osmosis Water Purifier. MELAdem 55

Commandomatic Ezysoft WATER SOFTENER SYSTEM

User Manual. Dishwasher IDSH604W

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

FAVORIT VI EN DISHWASHER USER MANUAL.

Green Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

MODEL 7000 SUCTION UNIT

PUROTAP easy. Installation Function Operation Service. fast efficient safe. Demineralised heating water perfect for every system

FAVORIT 55200VI EN DISHWASHER USER MANUAL

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

7800 Neutralizer Installation & Start-Up Guide

Installation, Operation, and Maintenance Manual. Waterlogix Metered Residential Water Softener

1850 Series TRIPLE TREAT Operation Manual

PUROTAP leader. Installation Function Operation Service. Demineralised heating water perfect for every system

Installation Instructions / Warranty

ESL 5201LO EN DISHWASHER USER MANUAL

Coffee Machine Zia series

GETTING STARTED? EASY.

ESL5205LO. EN Dishwasher User Manual

User manual. Dishwasher ZDT12041FA

Coffee Machine Siro Touch 600 series

FSS62800P. User Manual Dishwasher USER MANUAL

Get usage advice, brochures, trouble shooter, service information: Register your product for better service:

6700 Valve Downflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #51431 Rev.

CONTENTS. Page. Contents. Introduction, features and benefits. PART ONE Overview of the water softening process 4-5

User manual. Dishwasher ZDI12010XA

GETTING STARTED? EASY.

5700-E Sediment Filter Installation & Start-Up Guide

FAVORIT 34502VI0. EN User manual

User Manual Dishwasher FAVORIT 56302MO FAVORIT 56302WO

SERVICE MANUAL. WS-55 Hobart Compact Water Softeners Installation Instructions - NOTICE - WS-55

User manual. Dishwasher ZDF14001WA ZDF14001KA ZDF14001SA

~-ti-=t"- MODELS. !'..,.~-_ ~ _,, -:~.. l- l.. -l > _ {.- ~ t "',, j ~ t. t- -,l-~ -+ _ "'l.,.._

Installation Instructions / Warranty

Installation Instructions. Instructions de montage. Instrucciones de instalación HC

GROWMAX WATER Perfect Water for Plants and Gardens

Table of Contents Thank you 2 Accessories 2 Installation 2 Tapping your first mini keg 3 Operation 9 Cleaning 9 Important safeguards 10 Limited

Oahu Showerspa Model #1035 Owner's Manual

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

Propane Flame Projector Safety instructions and operating manual

User manual. Dishwasher ZDT15010FA

Whirlpool Switzerland, Bauknecht AG, Industriestrasse 36, 5600 Lenzburg,

Refrigerator. Installation Guide. Free Standing Appliance

User Manual. Dishwasher ZDM17301SA ZDM17301WA

User Manual Dishwasher FAVORIT 66602VI0P

Installation instructions

Water Softener VSOFT 15. Fitting and operating instructions. Changes of technical details are reserved. VSOFT / BWT UK Limited F R E E H O M E

Fleck 2510 Softener Installation & Start Up Guide

FSS52610Z. User Manual Dishwasher USER MANUAL

INDUSTRIAL GLASS AND DISHWASHER USERS MANUAL - -

INSTALLATION INSTRUCTIONS

ESF5202LOW. EN Dishwasher User Manual

PS12 12 day Autotimer water softener

Fully Automatic Water Softeners

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual

GETTING STARTED? EASY.

Plumbline 2000 Series Metered Softeners Owners Manual Water Softener Models

CWS Plus Sediment Filter Installation & Start Up Guide

Transcription:

INSTALLATION GUIDE soft duomatik evoline Before introduction of the softener the installation guide has to be read carefully. For any disturbances cause by disregarding the instructions evo-water doesn t accept liability. evo-water GmbH Schulstraße 9 72535 Heroldstatt Tel.: +49 7389/906680 Fax : +49 7389/9066820 www.evo-water.com info@evo-water.com

Safety instructions: 1. Before installation the softener: Please refer to the corresponding installation and operation instructions in this manual. 2. Please refer to the local installation regulations and the general directives, in particular DIN 1988 and EN1717, also the valid accident prevention regulations. 3. With not designated use and improper service the manufacturer is released from any liability. 4. Before the installation please check the statics of the walls, covers and grounds for loading capacity. According to place of action a backflow must be installed corresponding to local regulation before the arrangement. For the protection of the central tax valves from rust, sand etc. a suitable mudflap or fine filter should be inserted before the arrangement. The filter pad of the fine filters should be exchanged according to DINAR / DVGW at a distance of 6 months or after soiling. Please ensure that no water damages are caused (e.g., by ground expiry). The manufacturer is not liable for water damages. The food water of the arrangement must correspond to the information of the German drinking water order. The room temperature must be at least 7 C and may not cross 50 C. 5. Changes in the system may not be made without consultation and approval with evo-water ohg, for damages no other guarantee is taken over. 6. The system serves exclusively for the removing of undesirable mineral substances which retreat as a scale. It serves as a pure system protection.

1. Parts: 1. BYPASS 8. BLENDING REGULATOR 2. VALVE HOUSING 9. HARDNESS REGULATOR 3. RESIN TANK 10. TO BRINE VALVE 4. CONTAINER FOR DEVICE AND SALT 11. CONNECTIONS (1/2",3/4, 1") 5. BRINE VALVE (float) 12. TO DRAIN 6. WATER INLET 13. COMMUNICATION TUBES 7. WATER OUTLET 14. TUBES TO BRINE VALVE

2. Precautions: Make sure you have all necessary tools on hand before you begin with the installation. Follow all local legal regulations. Read this manual carefully. If you have any questions or remarks, please contact your evo-water supplier. Check incoming pressure: minimum 1 bar (dynamic), maximum 8 bar (static) (15 PSI 116 PSI). If necessary reduce incoming pressure. Do not install the evo-water softener close to a heating source (environment temperature must be below 40 C). Protect softener and drain (12) against frost. Make sure you have the latest installation manual at hand. Check with your evo-water supplier. 3. Installation: 3.1 Close main valve and make sure pressure is released from piping. This can be done by opening at least one tap. 3.2 Connect the two units by means of the provided Y-pieces. You can find them in the salt compartment. The Y-piece with the filter inside, needs to be mounted at the inlet of the valve. (= bottom connection) The other must be mounted at the other connection. First connect the Y-piece to one unit and afterwards to the other unit. Secure them with the provided clips (4 pieces). You don t need to take the units out of the container to do this.

3.3 Check if all communication tubes are connected correctly. See picture below: the two quick-release couplings marked with a green dot should be connected by a communication tube (Ø4mm); the same should be done for the two couplings marked with a blue dot. 3.4 C u t w a t e r supply in order to install direct connections to the evo-water Softener or to install the evo-water Bypass (recommended). Follow the arrows on both Bypass and softener for water inlet and outlet. Pay attention that the inlet filter doesn t fall out. 3.4.1 o p e n m a i n with evo-water bypass with direct connections The evo-water Bypass has a ¾ connection. The direct connections on the water softener are available in ½, ¾ and 1.

Caution: before installing the softener, set the Bypass in bypass mode, not in service. 3.4.2 Connect both drain outlets (#12) to a local drain by means of the provided 13mm flexible drain pipe. (through a free flow off) In order to guarantee that the device will keep on functioning perfectly in the future, this drain pipe is spirally reinforced to avoid later blocking and/or kinks. It is possible that both drains are connected with each other through a Y-piece. In this case, connect the Y- piece to the local drain. Please protect the drain against frost and heat (min. temp. 5 C, max. temp. 40 C). When another drain pipe is used, the guarantee on the unit is expired. CAUTION: For the installation of the flexible drain hose to the fixed piping, please follow local legislation. maximum height and distance of flexible drain hose

3.5 Make sure to install the supplied overflow tap. First, pierce a hole (Ø21mm) in the side wall of the container. For the positions of the hole, there are two markings at the back of the container. They are situated around 15cm from the top of the container. (see figure below) Once the hole has been drilled, mount the overflow tap and secure it with the supplied nut. After drilling, remove all bits of plastic that have fallen into the container. A separate instruction leaflet with detailed information has been added to the device. You should also install the D.O.D. (Delta Open Drain), otherwise there is no guarantee. This part provides for the mandatory interruption, according to the European standard EN1717. If the D.O.D. is not connected to the drain pipe, the warranty of the appliance expires. The part with the two connectors and the transparent part are snapped together. So, when these parts pull out, you can just snap both parts. 1. Anschluβstück 1 für Spiralverstärkte Ablaufschlauch Ø13mm. 2. Anschluβstück 2 für Spiralverstärkte Ablaufschlauch Ø13mm. 3. Anschluss für Klebemoffe Ø40. 4. Anschluss für Abwasserleitung Ø40.

Connect the spiral Reinforced drain hose of the unit with one of the two connections on the D.O.D.. Slide the hose as far as possible onto the connection piece. Connect the spiral reinforcement drain hose to the other connector. Slide this hose as far as possible to the connector. This is only possible if the discharge hose of the overflow from the salt container is higher than the connection to the D.O.D. When the part with the connections for the discharge hose has detached itself from the transparent part, reassemble it. If they are snapped into each other, both parts can still rotate relative to each other. So you can still adjust the alignment of the connectors. If the two parts are detached from each other, you can glue them together.

Glue the complete D.O.D. In a drain pipe Ø40 or an adhesive socket Ø40. Make sure that the connections are horizontal and that both parts are well assembled.

3.6 Check if the brine valve is mounted correctly. This brine valve is mounted in the brine tube and it must sit all the way at the bottom, with the right side up. (see figure below) In order to check this, you need to remove the cover from the brine tube. 3.7 Verify if the brine valve is connected to the softener in the right way. The black tube Ø4mm comes from the brine valve, through the hole in the brine pipe and is then connected with the small T-piece. This T-piece connects the two pieces of brine tube that come from both units. Make sure that all tubes are fitted in the connections as far as possible. Check if there are no kinks in the tube and that the tube is not squeezed together. Pay attention: Watch carefully that you don t squeeze the tube when opening or closing the tilt drawer for the salt.

4. Settings: 4.1 Hardness regulator: =part number 9 on the illustration on page 2 Measure the hardness of incoming water by means of a hardness test kit (not supplied by evo-water). evowater uses ppm settings of CaCO 3. (10 ppm CaCO 3 = 1 fh) (1 dh = 1,78 fh) Adjust the hardness regulator to the measured value. This requires a hex key number 5. Remark: always set regulator on both units to the same setting.

4.2 Blending regulator: = part number 8 on the illustration on page 2 With the blending regulator, you can determine the outgoing hardness. Depending on the desired residual hardness, set outgoing hardness with a hex key number 5. The setting is proportional, i.e. 1/10 1/5 1/ of total incoming hardness. Remark: always set regulator on both units to the same setting. 5. Start up: 5.1 Leave Bypass in bypass mode, open main valve and flush for several minutes in order to avoid impurities from entering the softener. When you do not use a Bypass, open the main valve slowly as described in 5.4. 5.2 Fill salt container with salt in the provided space. Do not put salt tablets in the compartment where the softener is installed. Use only specific salt tablets that are suitable for softeners. 5.3 Add water in the salt container until the water level is approx. 10cm 4 high. (the float on the brine valve must be afloat)

5.4 Turn the bypass slowly to service mode. Open the main valve when you do not use a Bypass. 5.5 Open a tap behind the softener so a flow runs through it. Some air may flow from the tap; this comes from the softener. This will happen only once; at start-up. Once only water flows from the tap, and no more air, close the tap. 5.6 Perform a manual regeneration. 5.6.1 Choose one of both units to perform a manual regeneration. Use a hex key number 5 to turn the program disk (PRG) manually. Turn PRG counter clockwise until it is in above position. When the arrow and the small line on the transparent cover reach the area marked by B

(brining), the regeneration will start. Immediately, the PRG will drop down a little (you will be able to see and hear this). R stands for refill (refilling the container with water at the end of the regeneration stage). To make sure the softener is in regeneration, there should be a small water flow to the drain, and the water level in the container should drop. 5.6.2 Let regeneration perform until it stops automatically. The estimated time is approx. 12 minutes. When regeneration has stopped, no more water flows to the drain. This is a clear indication that the regeneration stage is over. 5.6.3 Open a tap behind the softener for several minutes to allow residual water to be flushed from the tubing. 5.6.4 Check outgoing hardness with a hardness test kit (not supplied by evowater). Adjust blending if necessary. 5.7 Put the cover on to the container. Before you do this, make sure that the tilt drawer for the salt is closed. Do not forget to connect the overflow with a drain.

5.8 Refilling salt. To refill the container with salt, you don t need to remove the cover. Just pull the tilt drawer, so that it tilts out of the container. If you pull out the drawer far enough it will stay fixed in the open position. In this position you can easily refill the drawer with salt tablets. When you are done refilling the salt, just lift the cover a little bit and push the tilt drawer back in the container. If the drawer is back in its position, the cover fits back on the container. Pay attention: Watch carefully that you don t squeeze the tube when opening or closing the tilt drawer for the salt.

6. Cleaning The device (= outside): The device may only be cleaned with a damp cloth. The use of abrasives, cleaning agents and / or soaps is never allowed. The resin: The only authorized cleaning agent for the resin is Delta Clean. Use of liquid acids or bases will destroy the function of the resins and cause damage to the plastic. In the following, you will find step by step how to clean the resins with Delta Clean: Disconnect the black wire Ø4mm from the valve. To do this, press the black ring on the coupling and pull the cable out of the coupling. (See figure) Take another piece of black wire Ø4mm, insert one end into the coupling from the valve (as far as possible) and the other end into the bottle Delta Clean.

Use an Allen key # 5 to manually rotate the program disc (PRG). Turn the PRG dial counterclockwise until it is as indicated at the top right. When the arrow and the line come on the transparent lid in the region of the letter "B" (brining, i.e., saline), the regeneration is started. The disc drops slightly downwards at this moment (this is visual and acoustically recognizable) Now DeltaClean is absorbed by the bottle through the device. Allow the device to absorb 150 ml of DeltaClean. When this happens, remove the black Ø4mm cable from the unit and plug the black Ø4mm lead from the solenoid valve back into the coupling from the unit. The device will now complete a full regeneration. After the suction, zone with letter 'B' (= Brining, curing), the program disk continues to turn until the arrow is in the zone with letter 'R' (refill, replenish the tank after regeneration with water). Let the regeneration expire until it is automatically terminated. The estimated duration is approximately 12 minutes. Repeat the procedure for the other valve. Open a tap behind the softener and rinse for several minutes to drain the remaining hard water from the piping.

REMARKS: It is recommended that a water softener is installed by a professional. Although the softener is probably the easiest and safest softener on the market, it is imperative that all necessary precautions are taken and local legislation is followed. This installation guide is written to help the professional installer keeping in mind that this person has essential knowledge about hydraulic softeners and domestic plumbing. Proper working of the softener will be determined by proper installation. An annual control of your Softener will guarantee optimal functioning and a long operating life. The EVO-WATER GmbH is proud of its achievement in having provided in what we believe to be the best softener available today. Moreover, we are proud to have you as a customer. We will do our utmost to deserve your trust. evo-water GmbH Schulstraße 9, 72535 Heroldstatt Tel.: +49 7389/906680 Fax : +49 7389/9066820 info@evo-water.com www.evo-water.com