Instruction Manual Model Backup Switch, 1 for 8

Similar documents
STATUS ALARM ALARM HISTORY POWER HISTORY RESET

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

IF-L/RF Protection Switch

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Instruction Manual Model L2 RF Switch

STATUS ALARM HISTORY ALARM RESET

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Added password for IP setup page : Password must be in IP format!

ACCURATE ELECTRONICS INC

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

6502B RF Distribution

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

21-light Remote Annunciator. Owner s Manual

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

Fratech Multipath-IP

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

USER'S MANUAL. Real Time Color Quad Processor. High Resolution, Broadcast Quality. Playback Zoom Function. RS232 Remote Control

RTD TEMPERATURE SENSING SYSTEM

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

USER MANUAL FOR OPERATING SYSTEM

Beacon 800 Gas Monitor Operator s Manual

Alarm Tone Generator Model AG17

Model AD C AD RS-422 Distributor

SCAN200E USER S MANUAL

Installation Manual COPYRIGHT NOTICE

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

FUSE PANEL. Technical Practice N N/L33 10/10 GMT Front Access NEBS Level 3 Certified

ERD97P21-U Receiver. Installation/ Operation Manual C939M-D (7/00)

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Metasys Integrator Compu-Aire Application

FUSE PANEL. Technical Practice N N/0803 5/5 GMT Front Access NEBS Level 3 Certified

Isolated Thermocouple Module

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Mark 25 Ultrapure Water Conductivity Analyzer

OPERATING MANUAL. EchoThermJ DIGITAL HOT PLATE MODEL HP30 AND HP30A. DOCUMENT NUMBER HP30-03 Revised 10 December 2011

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Metasys Integrator TITUS Application

CZ-6A Six Zone Interface Module

User manual. KNXgal. version

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Analog Input Module IC670ALG630

HRX Technical Manual. Version 1.2

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

TC Channel Serial-over-T1/E1 Multiplexer. User Manual MNL

GPS Evaluation Kit EVA1037/1080

PTE0705 Electric Fence Monitor

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

ModBus DE-1 INSTALLATION AND USER MANUAL

Model 4001 Series Single Channel Controller

GAS MONITOR Model Model

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Beacon 410A Gas Monitor Operator s Manual

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. DIGITAL CHILLING INCUBATOR MODELS MD5-600, MD5-602, AND MD5-604

P2267 NETWORK INTERFACE

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Global Water Instrumentation, Inc.

Metasys Integrator Cleaver-Brooks Application

Installation Instructions for the

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

ME 3011C / Alarm Indication / Quick Reference Guide

T3/E3 Fiber Optic Line Drivers

SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual

SyringeHeater.com. Syringe Heater. Thermo-Kinetic Heat Clamping. Model: HEATER-KIT-1LG HEATER-KIT-5SP

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

STRONG International FP-350 Operation and Installation Manual

SC-6 Six Supervised Control Module

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Smart Series TAS-05-11, TAS-05-12

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

Installation and Operations Manual

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

TC CH. 600Ω Analog & Dry Contact over T1/E1 Multiplexer. User Manual MNL

ECO N DATE DESCRIPTION OF CHANGE CHG

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

wireless. web-based. worthy of the name RACO.

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

The Protec driver connects to the Protec Fire Detection range of digital addressable fire control panels. Available for Commander and ObSys.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Transcription:

Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE 1 2 3 4 5 6 7 8 BU P P P P P P P P 2 A M A A A A A A M PROTECTION STATUS MENU EXECUTE Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. Printed in USA. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com

INSTRUCTION MANUAL MODEL 2582-282 Switch TABLE OF CONTENTS PAGE Warranty 2 1.0 General 3 1.1 Equipment Description 3 1.2 Technical Characteristics 5 1.3 Monitor & Control Interface 6 2.0 Installation 10 2.1 Mechanical 10 2.2 Rear I/O s 11 2.3 Front Panel Controls, Indicators 12 2.4 Operation 13 2.5 Menu Settings 14 3.0 Environmental Use Information 18 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc. s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc. s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com 2582-282 Manual_Rev.0 Page 2 12/19/11

MODEL 2582-282 Switch, 1 for 8 1.0 General 1.1 Equipment Description The 2582-282 1 for 8 Switch with Backup Controller provides Auto or Manual backup protection for up to 8 converters by relay switching IF and RF signals from one backup unit to any of 8 on-line units. The controller in the 2582-282 monitors alarms and settings of the on-line units and sets the backup unit to the parameters of the unit being backed up prior to backing it up. The 2582-282 works with standard Cross Up or Downconverters by polling their monitor and control ports on a periodic basis. A defective unit s inputs and outputs are switched from the failed unit to the backup when a failure occurs either automatically or manually. On-line, Off-line and not used modes can be programmed for each converter. Alarms are contact closures to ground. Status of the 2582-282 is reported via a serial data stream (Ethernet, Optional) and a contact closure to ground on alarm. All user settings of the switch are stored in nonvolatile ROM and on power up the 2582-282 polls all units. Manual Select is controlled by the multi-function switches on the front panel. LEDs indicate alarm and switch conditions. The unit is powered by two 100-240 ±10% VAC redundant power supplies, and housed in a 2RU chassis. MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE 1 2 3 4 5 6 7 8 BU P P P P P P P P 2 A M A A A A A A M PROTECTION STATUS MENU EXECUTE FRONT PANEL J10 SWITCH M&C GND CH1 J61 CH2 J62 CH3 CH4 CH5 CH6 CH7 CH8 BU J63 J64 J65 J66 J67 J68 J69 AC A AC B RF J21 J31 J22 J32 J23 J33 J24 J34 J25 J35 J26 J36 J27 J37 J28 J38 J29 J39 J1 J11 J2 J12 J3 J13 J4 J14 J5 J15 J6 J16 J7 J17 J8 J18 J9 J19 IF CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT REAR PANEL FIGURE 1.1 Model 2582-282 Front and Rear Panels 2582-282 Manual_Rev.0 Page 3 12/19/11

FIGURE 1.2 Model 2582-282 Switch Block Diagram 2582-282 Manual_Rev.0 Page 4 12/19/11

1.2 Technical Characteristics TABLE 1.0 2582-282 Switch Specifications* IF/L-Band Switch Characteristics Impedance/Return Loss 50 Ω / > 12 db Return Loss Type Relay Isolation > 55 db, DC to 1.5 GHz > 50 db, to 2.2 GHz; Switch time 100 milliseconds Insertion Loss 1.5 db, to 1.5 GHz; 2.0 db, to 2.2 GHz Configuration 1 for 8, no termination RF/L-Band Switch Characteristics Impedance/Return Loss 50 Ω / > 12 db Return Loss Type Relay Isolation > 55 db, DC to 1.5 GHz > 50 db, to 2.2 GHz; Switch time 100 milliseconds Insertion Loss 1.5 db, to 1.5 GHz; 2.0 db, to 2.2 GHz Configuration 1 for 8, no termination Controls, Indicators Manual Selection Push-button switches Remote Selection RS 232C (Optional RS 422/485 Option Q; Ethernet Option W8) Power Green LEDs Alarms Red LEDs Online Green LEDs Offline Yellow LEDs Other RF Connectors IF/L-Band Connectors Alarm/Remote Conn s Size Power SMA (female) BNC (female) DB9 (female) 19 inch, 2RU Standard Chassis X 16.0 D 100-240 ±10% VAC, Redundant Power Supplies *+10 C to +40 C; Specifications subject to change without notice 2582-282 Manual_Rev.0 Page 5 12/19/11

1.3 Monitor and Control Interface A) Remote serial interface Protocol: RS-232C/422/485, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. Connectors: Rear panel, DB-9 female SWITCH Pinouts (RS-232C/422/485) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed CH1,CH2,CH3,CH4,CH5,CH6,CH7,CH8, BU Pinouts Pin Function 1 Tx- 2 Tx+ (RS-232C) 3 Rx+ (RS-232C) 4 Rx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed 2582-282 Manual_Rev.0 Page 6 12/19/11

B) Status Requests Table 1.1 lists the status requests for the 2582-282 and briefly describes them. TABLE 1.1 2582-282 Status Requests Command Syntax * Description Command Status {aas1} Returns {aas1bcdefghijklmnopqrstuvwxyzabc} where: b = BACK-UP Status 0 = Normal, no channel backed up 1-8 = number of the channel currently backed up c = CH1 Status -- 0=PROTECTED, 1=UNPROTECTED, 2=UNUSED d = CH1 Mode -- 0=AUTO, 1=MANUAL, 2=REMOTE e = CH2 Status -- 0=PROTECTED, 1=UNPROTECTED, 2=UNUSED f = CH2 Mode -- 0=AUTO, 1=MANUAL, 2=REMOTE g = CH3 Status -- 0=PROTECTED, 1=UNPROTECTED, 2=UNUSED h = CH3 Mode -- 0=AUTO, 1=MANUAL, 2=REMOTE i = CH4 Status -- 0=PROTECTED, 1=UNPROTECTED, 2=UNUSED j = CH4 Mode -- 0=AUTO, 1=MANUAL, 2=REMOTE k = CH5 Status -- 0=AUTO, 1=MANUAL, 2=REMOTE, 2=unused l = CH5 Mode -- 0=AUTO, 1=MANUAL, 2=REMOTE m = CH6 Status -- 0=PROTECTED, 1=UNPROTECTED, 2=UNUSED n = CH6 Mode -- 0=AUTO, 1=MANUAL, 2=REMOTE o = CH7 Status -- 0=PROTECTED, 1=UNPROTECTED, 2=UNUSED p = CH7 Mode -- 0=AUTO, 1=MANUAL, 2=REMOTE q = CH8 Status -- 0=PROTECTED, 1=UNPROTECTED, 2=UNUSED r = CH8 Mode -- 0=AUTO, 1=MANUAL, 2=REMOTE s = CH1 Alarm -- 0 = normal, 1= alarm t = CH2 Alarm -- 0 = normal, 1 = alarm u = CH3 Alarm -- 0 = normal, 1 = alarm v = CH4 Alarm -- 0 = normal, 1 = alarm w = CH5 Alarm -- 0 = normal, 1 = alarm x = CH6 Alarm -- 0 = normal, 1 = alarm y = CH7 Alarm -- 0 = normal, 1 = alarm z = CH8 Alarm -- 0 = normal, 1 = alarm A = BACK-UP Alarm -- 0 = normal, 1 = alarm B = Power Supply A Alarm -- 0 = normal, 1 = alarm C = Power Supply B Alarm -- 0 = normal, 1 = alarm Min. Auto Switching Status {aasm} Returns {aasmb} where: b = Minimum Auto Switching mode status 0 = Normal, Min. Auto Switching OFF 1 = Min. Auto Switching ON Hold Status {aash} Returns {aashbc} where: b = Number of the channel currently backed up (0 if no channel is being backed up) C = Hold state -- 0 = not on hold; 1 = on hold * PLEASE NOTE: The Address (aa) should only be used when RS-485 is selected. 2582-282 Manual_Rev.0 Page 7 12/19/11

C) Commands Table 1.2 lists the commands for the 2582-282 and briefly describes them. After a command is sent the 2582-282 sends a return > indicating the command has been received and executed. If the command has an error (e.g., invalid value), the > character will not be returned. General Command Format - The general command format is {aacnd...}, where: { = start byte aa = address of unit (only used if in RS-485 mode) C = 1 character, either C (command) or S (status) N = 1-digit command or status number, 1 through 9 D = 1 character or more of data (depends on command) } = stop byte * PLEASE NOTE: The Address (aa) should only be used when RS-485 is selected. Table 1.2 2582-282 Commands Command Syntax* Description Set CH1 Status and Mode {aac1xy} where: x = 0; CH1 Protected x = 1; CH1 Unprotected x = 2; CH1 Unused y = 0; set CH1 to AUTO mode y = 1; switch BACK-UP to CH1 Set CH2 Status and Mode {aac2xy} where: x = 0; CH2 Protected x = 1; CH2 Unprotected x = 2; CH2 Unused y = 0; set CH2 to AUTO mode y = 1; switch BACK-UP to CH2 Set CH3 Status and Mode {aac3xy} where: x = 0; CH3 Protected x = 1; CH3 Unprotected x = 2; CH3 Unused y = 0; set CH3 to AUTO mode y = 1; switch BACK-UP to CH3 Set CH4 Status and Mode {aac4xy} where: x = 0; CH4 Protected x = 1; CH4 Unprotected x = 2; CH4 Unused y = 0; set CH4 to AUTO mode y = 1; switch BACK-UP to CH4 (Continued on page 9...) 2582-282 Manual_Rev.0 Page 8 12/19/11

Table 1.2 2582-282 Commands (continued from page 8) Command Syntax* Description Set CH5 Status and Mode {aac5xy} where: x = 0; CH5 Protected x = 1; CH5 Unprotected x = 2; CH5 Unused y = 0; set CH5 to AUTO mode y = 1; switch BACK-UP to CH5 Set CH6 Status and Mode {aac6xy} where: x = 0; CH6 Protected x = 1; CH6 Unprotected x = 2; CH6 Unused y = 0; set CH6 to AUTO mode y = 1; switch BACK-UP to CH6 Set CH7 Status and Mode {aac7xy} where: x = 0; CH7 Protected x = 1; CH7 Unprotected x = 2; CH7 Unused y = 0; set CH7 to AUTO mode y = 1; switch BACK-UP to CH7 Set CH8 Status and Mode {aac8xy} where: x = 0; CH8 Protected x = 1; CH8 Unprotected x = 2; CH8 Unused y = 0; set CH8 to AUTO mode y = 1; switch BACK-UP to CH8 Set Min. Auto Switching Mode {aacmx} where: x = 0; Minimum Auto Switching DISABLED x = 1; Minimum Auto Switching ENABLED Restore Switch Position {aachx} where: x = 0; Remove the 'hold' after the switch position changed in Minimum Auto Switching mode All external units (backup and channels 1 thru 8) can be controlled remotely via the 2582 switch. Converters to be controlled must be in remote mode. Simply enter a prefix of *0,*1,*2,*3,*4,*5,*6,*7,*8 for units where *0 is the backup, 1, 2, 3, 4, 5, 6, 7, 8, respectively, before entering the corresponding unit s status request or command. For example, to send a status command of S1 to converter #1 you would enter {aa*1s1}, where the address, aa, would only be necessary if the 2582 were in RS-485 mode. Any returned status will also be prefixed with a *0,*1,*2,*3,*4,*5,*6,*7,*8. 2582-282 Manual_Rev.0 Page 9 12/19/11

2.0 Installation 2.1 Mechanical The 2582-282 consists of one IF or L-Band Switching PCB, one Controller PCB, and one interface PCB housed in a 2 RU (3 1/2 inch high) by 16 inch deep chassis. Two redundant switching, ± 12, +24, +5 VDC power supplies provide power for the assembly. The 2582-282 can be secured to a rack using the 4 holes on the front panel. Figure 2.0 shows how the 2582-282 is assembled. Interface PCB on Top IF Switch PCB on Bottom POWER SUPPLY 2 Interconnect Cables POWER SUPPLY 1 Controller PCB FIGURE 2.0 2582-282 Mechanical Assembly 2582-282 Manual_Rev.0 Page 10 12/19/11

2.2 Rear Panel Input/Output Signals Figure 2.1 shows the input and output connectors on the rear panel. SWITCH M&C Monitor and controls for the 2582 switch. CH1 to CH8 MONITOR - J62 - J69 Monitors for an alarm from Unit #1 to Unit #8. BU MONITOR Monitors for an alarm from Back-Up unit. J10 SWITCH M&C GND CH1 J61 CH2 J62 CH3 CH4 CH5 CH6 CH7 CH8 BU J63 J64 J65 J66 J67 J68 J69 AC A AC B RF J21 J31 J22 J32 J23 J33 J24 J34 J25 J35 J26 J36 J27 J37 J28 J38 J29 J39 J1 J11 J2 J12 J3 J13 J4 J14 J5 J15 J6 J16 J7 J17 J8 J18 J9 J19 IF CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT CONV IN/OUT AC A, AC B - POWER IN AC inputs for redundant switching power supplies. 100-240 ±10% VAC, 47-60 Hz. RF SIGNALS -J21-J29 & J31-J39 Signals to/from Unit #1 to #8 and the Backup Unit CONV goes to the up/down converter IN/OUT is the input to or the output from the converter. SMA (female) 50Ω. IF 2 SIGNALS J1-J9 & J11-J19 Signals to/from Unit #1 to #8 and the Backup Unit CONV goes to the up/down converter IN/OUT is the input to or the output from the converter. BNC (female) 50Ω. FIGURE 2.1 2582-282 Rear Panel I/Oʼs TABLE 2.1 SWITCH Pinouts (RS-232C/422/485) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed *Remote Serial Interface Interface: DB-9 Male Protocol: RS-232C/422/485, 9600 baud rate, no parity, 8 data bits, 1 start bit, 1 stop bit. TABLE 2.2 CH1,CH2,CH3,CH4,BU Pinouts Pin Function 1 Tx- 2 Tx+ (RS-232C) 3 Rx+ (RS-232C) 4 Rx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed 2582-282 Manual_Rev.0 Page 11 12/19/11

2.3 Front Panel Controls and Indicators Figure 2.2 shows the front panel controls and indicators. ALARM LED Illuminates red if the switch malfunctions ALARM STATUS LEDs Red LEDs remains on if the respective unit is alarmed. Red LED blinks if the respective unit is not alarmed but the switch cannot communicate to it via M&C. Back-Up LEDs Green LED for BU indicates a unit is being backed up. S1 - MENU/EXECUTE BUTTON Press this to get into Program Mode and to execute any changes. S2 - VERT. TOGGLE Vertical toggle switch that controls values in the Menu items when in program mode. Does not function in the normal display mode. MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE 1 2 3 4 5 6 7 8 BU P P P P P P P P 2 A M A A A A A A M PROTECTION STATUS MENU EXECUTE POWER LEDs Green LEDs indicate DC voltage from each power supply. ONLINE/OFFLINE LEDs Green LEDs for CH1 to CH8 indicate they are online. Yellow LEDs for CH1 to CH8 indicate they are offline. LCD DISPLAY Display shows if CH1 to CH8 are protected or not, what mode CH1to CH8 are in (AUTO, MANUAL, REMOTE), and which channel is being backed up (if any). S3 - HORIZ. TOGGLE Horizontal toggle switch that controls which values are being adjusted. Does not function in the normal display mode. FIGURE 2.2 2582-282 Front Panel Controls and Indicators 2582-282 Manual_Rev.0 Page 12 12/19/11

2.4 Installation / Operation 2.4.1 Installing and Operating the 2582-282, Switch Section. 1. Connect Converters (CH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8, BU) to respective channels on the 2582 (Figure 2.1). 2. Connect Alarm/Control cables from Converters to respective monitors on the 2582 (Figure 2.1). 3. Connect two 100-240 ± 10% VAC, 47-63 Hz power cords to AC A and AC B on the back panel (Figure 2.1). 4. Set which unit(s) you wish to protect and the mode for each unit (See Section 2.5 Menu Settings). 5. Be sure PSA & PSB (green, DC Power) are on and the red alarm LED is off (Figure 2.2). 6. AC Fuses - The fuses are 5 mm X 20 mm, 2 amp slow blow (Type T) and are inserted in the far slot in the drawer below the AC inputs as shown in Figure 2.3. There is a spare fuse in the near slot. If a fuse continues to open, the corresponding power supply is most likely defective. FUSE DRAWER SPARE FUSE AC Fuse - 2 amp slow blow (Type T), 5 mm X 20 mm ~ INPUT 100-240± 10%VAC 47-63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100-240 V~ FIGURE 2.3 Fuse Location and Spare Fuse 2582-282 Manual_Rev.0 Page 13 12/19/11

2.5 Menu Settings 2.5.1 Functions - This section describes operation of the front panel controls. There are three operator switches, the LCD display and alarm indicator LEDs. All functions for the equipment are controlled by these components. The functions are (see Figure 2.4): Power Up Normal Display Menu 1 Menu 2 Menu 3 Menu 4 Menu 5 Menu 6 Menu 7 Menu 8 Menu 9 Menu 10 Menu 11 Menu 12 Set CH1 Protected/Unprotected/Unused and Set CH1 Mode (MANUAL overrides REMOTE which overrides AUTO) Set CH2 Protected/Unprotected/Unused and Set CH2 Mode (MANUAL overrides REMOTE which overrides AUTO) Set CH3 Protected/Unprotected/Unused and Set CH3 Mode (MANUAL overrides REMOTE which overrides AUTO) Set CH4 Protected/Unprotected/Unused and Set CH4 Mode (MANUAL overrides REMOTE which overrides AUTO) Set CH5 Protected/Unprotected/Unused and Set CH5 Mode (MANUAL overrides REMOTE which overrides AUTO) Set CH6 Protected/Unprotected/Unused and Set CH6 Mode (MANUAL overrides REMOTE which overrides AUTO) Set CH7 Protected/Unprotected/Unused and Set CH7 Mode (MANUAL overrides REMOTE which overrides AUTO) Set CH8 Protected/Unprotected/Unused and Set CH8 Mode (MANUAL overrides REMOTE which overrides AUTO) Set Remote interface Set RS-485 address Set Minimum Auto Switching Mode ON and OFF Restore Switch Position in Minimum Auto Switching mode Save Menu When R is selected or when get to the end Alarm indications appear on the LEDs (see figure 2.2). All program changes must start with the operation of the Menu/Execute switch and must also end with the operation of the Menu/Execute switch verified by the Save Settings? Menu. If this sequence is not followed, none of the changes will take effect. 2582-282 Manual_Rev.0 Page 14 12/19/11

2.5.2. Power On Settings NOTE: The last status of a unit is retained even when power is removed. When power is restored, the unit will return to it's previous settings. When power is first applied, the LCD display goes through six steps: 1. All alarm, offline & online LEDs are turned on. If any one does not come on, there is a hardware fault that should be fixed. 2. The LCD goes black to show all segments are functioning. 3. The model number and software version will be displayed. 1 2 3 4 5 6 7 8 BU PROT MODE 2582-282 Rev. 5.00 PROTECTION STATUS 4. Green LEDs are lit in succession, 1 thru 8 and backup. This is the initial scan for all channel settings. 5. All alarm, offline & online LEDs are set by the control program to reflect the current states of the attached units. 6. The present protection state and mode of each channel/unit are shown. 1 2 3 4 5 6 7 8 BU PROT MODE P P P P P P P P 2 A A A A A A A A M PROTECTION STATUS The unit is now operational and ready for any changes the operator may desire. 2.5.3 Control Switches 1. Menu/Execute - Any change to the programming of the unit must be initiated by pressing the Menu/Execute switch and completed by pressing the Menu/Execute switch. 2. Horizontal Switch - This switch is mounted so its movement is horizontal and moves the cursor left or right. 3. Vertical Switch - This switch is mounted so its movement is vertical, and changes settings in each menu. 2.5.4 Alarm Indications An alarm condition will occur if the corresponding unit s local oscillator phase lock loop (PLL) comes out of lock (when connected properly). 2582-282 Manual_Rev.0 Page 15 12/19/11

FIGURE 2.4 2582-282 Menu Display and Sequences Power Up Normal Display PROT MODE PROT MODE ON POWER UP 2582-282 REV 5.00 NORMAL DISPLAY 1 2 3 4 5 6 7 8 BU P A P A P A P A P A P A P A P A PROTECTION STATUS A PUSHING MENU/EXECUTE SEQUENCE Menu 1 Set CH1 protection & mode = = = = CH1 = = = = Protected Auto R Menu 2 Set CH2 protection & mode = = = = CH2 = = = = Protected Auto R Menu 3 Set CH3 protection & mode = = = = CH3 = = = = Protected Auto Menu 4 Set CH4 protection & mode = = = = CH4 = = = = Protected Auto R Menu 5 Set CH5 protection & mode = = = = CH5 = = = = Protected Auto R Menu 6 Set CH6 protection & mode = = = = CH6 = = = = Protected Auto R Menu 7 Set CH7 protection & mode = = = = CH7 = = = = Protected Auto R Menu 8 Set CH8 protection & mode = = = = CH8 = = = = Protected Auto R Menu 9 Set Remote mode Remote Interface RS232 R Menu 10 Set RS-485 Address RS485 Address = 00 R Menu 11 Set Minimum Auto Switching Minimum Auto Switching OFF R Save? When R is selected from any above menu or at the end. SAVE SETTINGS? Y N 2582-282 Manual_Rev.0 Page 16 12/19/11

2.5.5 Minimum Auto Switching Mode Enabling and Disabling The Minimum Auto Switching mode is enabled and disabled via a front panel menu. The Minimum Auto Switching mode can also be enabled and disabled via the following M&C command: {CMx} Where x=1 to enable and x=0 to disable. The status of the 2582-282 Minimum Auto Switching mode setting can be queried by sending the following command: {SM} Which returns {SMx} where x=1 if enabled and x=0 if disabled. Operation In the Minimum Auto Switching mode the switch will remain in a backup state after an alarm event - even if the alarm event that caused the unit to switch has been cleared. The main display will show an H (hold) under the BU MODE after an alarm causes the switch to change states while in the Minimum Auto Switching mode. The unit can be restored to the normal state via a front panel restore command or an M&C restore command. The front panel Restore Switch menu appears after the Minimum Auto Switching mode ON/OFF menu only if the Minimum Auto Switching mode is on. The backup can also be released from its hold state via the following M&C command: {CHx} Where x = 0 to restore. NOTE: The switch will automatically restore - as soon as the alarm event that caused the unit to switch has been cleared - IF the Minimum Auto Switching mode is disabled either via the front panel setting or by the M&C command. 2582-282 Manual_Rev.0 Page 17 12/19/11

2.5.6 Switch Actions in Response to Various Conditions General Operation Description If one of channels 1 thru 8 is alarmed, the 2582 automatically switches the RF signals from that unit to the backup unit. I.e., the alarmed unit is now offline and the backup unit is now online operating in place of the alarmed unit. If more than one unit is alarmed, only the highest priority unit is backed up. The priority is based on the channel number where 1 is the highest priority and 8 is the lowest. However, if a unit s settings have never been successfully obtained by the 2582 since being powered up, then the 2582 does not have settings with which to program the backup unit for that channel. Therefore, if the 2582 does not have settings for an alarmed unit, that alarmed unit cannot be backed up. Any one of the following conditions will prevent an alarmed unit from being automatically backed up. a) The 2582 never successfully obtained settings from the unit. b) The unit s protection setting is not PROTECTED. c) The unit s mode setting is not AUTO. d) The backup unit is alarmed. e) A unit of higher priority is already being backed up. f) Some other unit is being forcefully backed up via MANUAL or REMOTE. g) Minimum auto switching is on and is holding another channel in backup until released. Specifics The following describes specific conditions in more detail, the response of the 2582 and any changes to the display or LEDs to indicate the stated condition. 1. Channel i is alarmed. Highest priority unit is backed up. Channel i has higher priority than channel j if i < j. Remaining units are online, even if alarmed. 2. Failure to obtain settings from unit i at power up. Red LED i blinks. Unit i can not be backed up since there are no settings with which to program the BU unit. 3. Failure to detect unit i s communication after power up. In firmware, unit i is declared not connected. Red LED i blinks. No other corrective action is taken. If alarmed & the highest priority channel, unit i will be backed up using the latest settings successfully obtained from the unit. (continued...) 2582-282 Manual_Rev.0 Page 18 12/19/11

4. Failure to successfully send settings to unit i when switching i back online from being backed up. No corrective action is taken. If preempted by a higher-priority unit needing to be backed up, unit i is switched online anyway. If alarmed & the highest priority channel, unit i will be backed up using the latest settings successfully obtained from the unit. 5. Backup unit is alarmed. No unit can be backed up. Any channel being backed up is switched back online at the time the BU unit alarms. 6. Channel i is set for UNUSED. X appears on the display under the channel number for both Prot. & Mode. Unit is not considered for backing up. LEDs for that unit are all turned off. 2582-282 Manual_Rev.0 Page 19 12/19/11

3.0 Environmental Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. C. Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. D. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between units may be required. E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring. Appropriate consideration of equipment name plate rating should be used when addressing this concern. F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch (use of power strips). G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 2582-282 Manual_Rev.0 Page 20 12/19/11

CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com Printed in USA 2582-282 Manual_Rev.0 Page 21 12/19/11