Heavy Duty Transformer. Low Voltage Circuit Breaker. Visit us at For the latest technical information,

Similar documents
G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

ML 1 93 UH 070 x P 36 B

MERIT SERIES Up Flow / Horizontal

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

MERIT SERIES Downflow

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

MERIT SERIES Upflow / Horizontal

ELITE SERIES Downflow - High Efficiency Blower Motor

ML 1 80 UH 070 X E 36 B

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal

MERIT SERIES Downflow

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

ELITE SERIES Upflow / Horizontal - Two-Stage Heat

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17.

MERIT SERIES Upflow / Horizontal

AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE

8+* Bulletin No November 1997

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MERIT SERIES Downflow

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

13 GEP A L P - 1 A

GSR21Q PULSE21 SERIES

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

RGE 13 A T - 1 A

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

G34M Bulletin #69/ August 2003

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

AFUE 95% Heating Input 50,000 to 200,000 Btuh

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

G32V. Service Literature G32V SERIES UNITS

GHR32Q/V SERIES UNITS

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

MERIT SERIES Up Flow / Horizontal

EL195UH WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. EL195UH SERIES UNITS

TECHNICAL SPECIFICATIONS

RG7D 1-Stage Heat Series

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

Corp L12 Revised G24M SERIES UNITS

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Wt. Lbs Model Number (BTUH) Hz

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Cooling Capacity CFM range

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

U n i t H e at e r s

GHR26. Service Literature GHR26 SERIES UNITS DOWN FLOW POSITION HORIZONTAL POSITION

TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

TECHNICAL SPECIFICATIONS

TSTAT0101SC Recommended (order separately)

Cooling Capacity CFM in. w.c. (125 Pa)

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

TECHNICAL SPECIFICATIONS

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

TSTAT0201CW Recommended (sold separately)

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

CB X 32 mv

F8AUH Gas Furnaces Up-Flow/Horizontal

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Transcription:

ENGINEERING DT Duralok Plus luminized Steel Heat Exchanger Pressure es Factory installed Field Wiring Make Up Box can be installed on either side Tool Less Entry Sight Glass Terminals for ccessory Connections (powered air cleaners and humidifiers) SureLight Patented Hot Surface Ignition System Two Stage / Variable Speed Blower Control Board with Diagnostic LED s DVE LENNOX SIGNTURE COLLECTION Multi Position Variable Speed Blower Direct Vent/Non Direct Vent Two Stage Heat FUE up to 94.6% Input 66,000 to 132,000 Btuh Nominal dd on Cooling 2 to 5 tons Heavy Duty Transformer Gas and electrical connections from either side of cabinet Variable Speed Slide Out Blower luminized Steel Inshot Burners Two Stage Combustion ir Inducer Combination Two Stage Gas Control Valve GS FURNCES G61MPV Bulletin No. 210390 ugust 2003 Low Voltage Circuit Breaker MODEL NUMBER IDENTIFICTION Unit Type G = Gas Furnace Series 61 = Two Stage 90% FUE FETURES Configuration MP = Multi Position Blower V = Variable Speed Blower Motor Nominal dd On Cooling Capacity 36 = 1 3 tons (3.5 10.6 kw) 60 = 4 5 tons (14.0 17.6 kw) G 61 MP V 36 B 070 1 Evaporator coils with the same letter designation will physically match the furnace. CONTENTS Blower Data............................... Pages 13 17 Dimensions................................ Pages 8 13 Exhaust Pipe Venting Table...................... Page 4 Features.................................... Pages 1 3 Filter ir Resistance............................. Page 7 High ltitude Information......................... Page 4 Installation Clearances........................... Page 7 Model Number Identification...................... Page 1 Optional ccessories......................... Pages 3 4 Specifications................................ Pages 5 6 Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Nominal Gas Heat Input 070 = 66,000 Btuh (19.3 kw) 090 = 88,000 Btuh (25.8 kw) 110 = 110,000 Btuh (32.2 kw) 1 135 = 132,000 Btuh (38.7 kw) Cabinet Width B = 17 1/2 in. (445 mm) C = 21 in. (533 mm) D = 24 1/2 in. (622 mm) WRRNTY Duralok Plus luminized Steel Heat Exchanger Limited lifetime warranty in residential applications (twenty year transferrable), twenty year limited warranty in non residential applications. SureLight ignition control module Five year limited warranty in residential applications, one year limited warranty in non residential applications. ll other covered components Five year limited warranty in residential applications, one year limited warranty in non residential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. NOTE Due to Lennox ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2003 Lennox Industries Inc.

FETURES PPLICTIONS Input capacities of 66,000, 88,000, 110,000, and 132,000 Btuh (19.3, 25.8, 32.2, and 38.7 kw). Energy efficiency (FUE) up of 94.6% in all four installation configurations. Compact cabinet for up flow, down flow, horizontal left or horizontal right applications without any internal modifications to the unit. Lennox add-on evaporator coils, high efficiency air cleaners and humidifiers can easily be added to furnace. Shipped factory assembled with all controls installed and wired. Each unit factory test operated to ensure proper operation. PPROVLS Units certified by CS International and ratings are certified by GM. Units tested and rated according to US DOE test procedures and FTC labeling regulations. Blower data from unit tests conducted in Lennox Laboratory air test chamber. pproved by the California Energy Commission and meet California Seasonal Efficiency requirements and California Nitrogen Oxides (NOx) Standards. ENERGY STR certified units are designed to use less energy, help save money on utility bills, and help protect the environment. ISO 9001 Registered Manufacturing Quality System. HETING SYSTEM Lennox Duralok Plus Heat Exchanger ssembly Lennox developed heat exchanger assembly consists of primary heat exchanger and secondary condenser coil assembly. Main 3-pass crimped seam design clamshell type heat exchanger. Constructed of heavy gauge, aluminized steel. Designed for normal expansion and contraction with maximum efficiency and minimum resistance to airflow. Secondary heat exchanger condenser coil constructed of aluminum fins fitted to stainless steel tubes. Coil is factory tested for leaks. Condensate drain header box assembly located on front of coil. Compact size of complete heat exchanger assembly permits low overall design of furnace cabinet. ll components mounted in a heavy gauge steel frame. Heat exchanger assembly has been laboratory life cycle tested. Lennox Designed Header Box Header box on end of condenser coil collects flue condensate for disposal through condensate collars. Hose connects the header box drains to the condensate collars. The condensate collars are located on each side of the cabinet for easy field installation of condensate drain trap. Only one collar is used, the remainder stay plugged. Condensate drain trap is included with the unit for field installation. Lennox Designed Flue Condensate Trap ssembly Condensate trap assembly is mounted outside the conditioned air stream. ssembly can be mounted on either side of cabinet in up flow and down flow applications. ssembly is mounted on the bottom of the cabinet in horizontal applications. See Installation Instructions. Connection can be made with field provided 1/2 in. PVC pipe, 3/4 in. PVC coupling, or 1 1/4 in. OD x 1 in. ID vinyl tubing with hose clamp. Easy to clean and winterize. Inshot Burners luminized steel inshot burners provide efficient, trouble free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Burner assembly is removable from the unit as a single component for ease of service. Two Stage Gas Control Valve 24 volt redundant combination two stage gas control valve combines manual shut off valve (On Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. Flame Rollout Manual reset switches are factory installed on burner box. provides protection from abnormal operating conditions. SureLight Hot Surface Ignitor Tough, reliable, long life, trouble free performance. Tungsten heater element sandwiched between two plates of silicon nitride. Cemented to steatite block for protection against current leakage. Ignition leads constructed of nickel plated copper enclosed in high temperature Teflon insulation for dependable operation. No electrical noise. Combustion ir Inducer PSC, heavy duty blower prepurges heat exchanger and safely vents flue products. Pressure switches prove blower operation before allowing gas valve to open. Operates only during heating cycle. Limit Control utomatic reset, primary and secondary limits are accurately located. Primary limit factory installed on vestibule panel on all units, secondary limit factory installed on blower housing. BLOWER Variable Speed Direct Drive Blower Each blower assembly statically and dynamically balanced. Change in blower speed is easily accomplished by simple DIP switch change on SureLight Integrated Furnace Two Stage / Variable Speed Blower Control. See Blower Performance tables. Blower assembly easily removed for servicing Variable Speed Blower Motor Variable speed motor maintains specified air volume from 0 though 0.80 in. w.g. (0 through 200 Pa) static range. Motor is controlled by SureLight Integrated Furnace Two Stage / Variable Speed Blower Control. Motor is resiliently mounted. When furnaces are used with Harmony Zone Control System, blower motor operates from predetermined minimum maximum air volumes to satisfy zone requirements. COIL MTCH UP ll furnaces exactly match C33 and CX34 cased up flow evaporator coils and CH33 horizontal evaporator coils with same letter designation in model number. No adaptor required. Engaging holes furnished on cabinet for alignment. C33 uncased coils match furnaces without any overhang but require an optional adaptor base or field fabricated transition to match furnace opening. See C33 coil bulletin for additional information. ll furnaces exactly match CR26 cased, down flow evaporator coils with adaptor rails, furnished with coil. FILTER (NOT FURNISHED) Filter and provisions for external mounting must be field provided. G61MPV / Page 2

FETURES CONTROLS SureLight Integrated Two Stage / Variable Speed Blower Control Solid state board contains all necessary controls and relays to operate furnace. Combustion air inducer is controlled by board. Prior to ignition, a low speed pre purge cycle for 15 seconds is initiated. fter the main burners are turned off, a post purge cycle for 5 seconds is run. daptive technology of ignition control board continuously monitors and adjusts the ignitor power to operate at minimum ignitor temperature required for ignition, prolonging ignitor life. Electronic flame sensor assures safe and reliable operation. Should flame fail to ignite, flame sensor will initiate 4 re attempts at ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Jumper settings for single or two stage thermostat operation. Two selectable 2nd stage recognition times (10 and 15 minutes) are available on the board when the furnace is used with a single stage thermostat. When used with a two stage thermostat, furnace will only initiate second stage operation with a second stage thermostat demand. Two LED s indicate heating status and aid in troubleshooting. Two accessory terminals furnished for additional power supply requirements for 120 volt (less than 1 amp) power humidifiers and electronic air cleaners. Control interfaces variable speed motor with thermostat and optional CCB1 humidity control. Two blower speeds second stage heat and second stage cool (with four air volume selections for each) are selected by DIP switches on board. Heat speed can be adjusted to optimize discharge temperature. Cool speed can be adjusted to correct optional cooling capacity. See Blower Performance tables. First stage blower speed is a percentage of second stage speed. The DJUST switch (DIP) allows normal (NORM), 10% higher (+ plus) or 10% lower ( minus) motor speed selection within HET and COOL speeds selected for fine tuning air volume. DELY switch (DIP) allows one of four de humidification profiles during cooling mode. Profile Motor runs at 50% for 30 seconds, then at 82% for 7 1/2 minutes, then at 100% (if needed) until demand is satisfied. Once demand is met, motor runs at 50% for 30 seconds, then ramps down to stop. Profile B Motor runs at 82% for 7 1/2 minutes and then at 100% (if needed) until demand is satisfied. Once demand is met,motor ramps down to stop. Profile C Motor runs at 100% until demand is satisfied. Once demand is met, motor runs at 100% for 60 seconds, then ramps down to stop. Profile D Motor runs at 100% until demand is satisfied. Once demand is met, motor ramps down to stop. OPTIONL CCESSORIES MUST BE ORDERED EXTR Down Flow dditive Base Required for heating only units installed on combustible floors. Not required in add-on cooling applications. See Dimension Drawing. FILTERS ir Filter and Rack Kit for Horizontal Return ir (End) pplications Washable or vacuum cleanable polyurethane frame type filter and external end return air rack available for field installation. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. See dimension drawing. ir Filter and Rack Kit for Side Return ir pplications (Not for use with RB Return ir Base) Washable or vacuum cleanable polyurethane frame type filter In heat mode, blower on time is fixed at 45 seconds, blower off time is adjustable from 60, 90, 120 and 180 seconds (factory setting 90 seconds). Control has four status lights (CFM, ON/OFF, HTG BLOWER, HI/LOW) to assist in servicing. For air conditioning applications, blower on time is 2 seconds following thermostat demand for cooling. Board controls evaporator humidity by controlling blower and compressor speed on two stage outdoor units when used with CCB1 humidity control or Lennox SignatureStat. Control is factory installed in the unit control box. 24 Volt Transformer Furnished and factory installed in control box. 40V transformer has circuit breaker wired in series. Field Wiring Make-up Box Furnished for line voltage wiring. Factory installed internally on left side of furnace. Box may be installed internally or externally on either side of furnace. CBINET Low profile, narrow width cabinet allows easy installation in up flow, down flow or horizontal applications. Heavy gauge, cold rolled steel construction. Pre painted cabinet finish. Flanges provided on supply air opening for ease of plenum connection or alignment with evaporator coil. Fully insulated cabinet with foil faced insulation on sides and back of heating compartment and mat faced insulation in blower compartment. Complete service access. Safety interlock switch automatically shuts off power to unit when blower compartment access door is removed. Gas piping and electrical inlets are provided in both sides of cabinet. Return ir Entry: For bottom return air entry, remove furnished bottom seal panel from cabinet. For side return air entry (up flow applications only), corners are marked on either side of cabinet for return air cut outs. See dimension drawings. NOTE 60C and 60D size units that require air volumes over 1800 cfm (850 L/s) must have one of the following: 1. Single side return air with transition, to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter, required to maintain proper air velocity. 2. Single side return air with optional RB Return ir Base. 3. Bottom return air. 4. Return air from both sides. 5. Bottom and one side return air. See Blower Performance Tables for additional information. and external side return air rack available for field installation. vailable in single and ten pack kits. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. Field installs on either side of unit cabinet. See dimension drawing. EZ Filter Base for Bottom Return ir pplications Hinged door with thumbscrew for easy filter access. Uses standard size filters (field provided). RB RETURN BSE For 60C and 60D models with air volumes over 1800 cfm (850 L/s) in up flow applications when only one side return is required. Cabinet is pre painted steel to match the furnace. See Dimension Drawing. G61MPV / Page 3

OPTIONL CCESSORIES MUST BE ORDERED EXTR TERMINTION KITS Facilitates installation of combustion air intake pipe and flue exhaust pipe. Refer to venting table in this bulletin to determine pipe size needed and proper termination kit required. See Specifications table and dimension drawings. Termination Kit Concentric Direct Vent pplications Only 1 1/2, 2, or 3 inch (38, 51, or 76 mm) kit contains concentric termination assembly, mounting clamp, roof flashing, reducer bushing and 45 degree elbow. Kit requires single hole penetration of roof or wall for installation. CS certified. Termination Kit Roof Direct or Non Direct Vent 2 or 3 inch (51 or 76 mm) kit contains two neoprene rubber roof flashings. Termination Kits Wall ssembly Close Couple Direct Vent pplications Only 2 or 3 inch (51 or 76 mm) kit consists of close-couple, side-byside PVC piping with galvanized steel wall cover plate for sealing and isolating piping penetration of the wall. Piping spacing and length is sized for proper wall installations. CS certified. Close Couple WTK Direct Vent pplications Only 2 or 3 inch (51 or 76 mm) kit contains one insulated faceplate, one insulated exhaust pipe, elbow and fittings. Wall Ring Direct or Non Direct Vent 2 inch (51 mm) kit contains 2 stainless steel outside seal caps, 2 galvanized steel inside seal caps, 4 seal rings for the caps and 18 inch (457 mm) insulation sleeve for sealing and isolating intake and exhaust piping penetration of wall. Maintain a maximum of 6 inches (152 mm) between the inlet and outlet openings in the installation of the pipes. Condensate Drain Heat Cable Kits Self-limiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. vailable in 6, 24 or 50 ft. (1.8, 7.3, or 15.2 m) lengths. Heat Cable Tape: 66 ft. (20 m) length, 1/2 in. (13 mm) wide fiberglass. 60 ft. (18 m) length, 2 in. (51 mm) wide aluminum foil. HIGH LTITUDE KITS High ltitude Orifice Kit Natural Gas Only Required for all natural gas models for proper unit operation at altitudes of 7501 to 10,000 feet (2286 to 3048 m). High ltitude Pressure Kit Required on certain units for proper unit operation on installations above 4,500 ft. (1372 m). Order two per unit. EXHUST PIPE VENTING TBLE Gas Conversion Kits LPG/Propane Conversion Kit Required for field changeover from natural gas to LPG/Propane. Natural Gas Conversion Kit Required for field changeover from LPG/Propane to natural gas. Horizontal Support Frame Kit Provides support of unit in horizontal applications. Consists of (2) 1 x 1-1/2 x 32-5/8 in. (25 x 38 x 829 mm) and (2) 1 x 3 x 53-7/8 in. (25 x 76 x 1368 mm) painted, heavy gauge cold rolled steel support channels with assembly and suspending holes. Bolts and nuts furnished for field assembly. Suspending rods must be field provided. Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. SignatureStat Home Comfort Controller Combination temperature and humidity control in cooling mode. 2 Heat/2 Cool uto changeover Easy to use, menu driven thermostat with a back lit, dot matrix LCD screen. Remote outdoor sensor (furnished) allows the thermostat to display outdoor temperature and adjust indoor dewpoint temperature for precision humidity control in cooling mode. See the SignatureStat Engineering Handbook bulletin in the Controls section for more information. HIGH LTITUDE INFORMTION Pressure regulator adjustment may be required depending on altitude. See below for proper pressure regulator setting. Manifold Pressure (Outlet) in. w.g. (kpa) Fuel ltitude ft. (m) High Fire Low Fire Natural 0 4500 (0 1372) 3.5 (0.87) 1.7 (0.42) 3 LPG Propane 4501 7500 (1373 2286) 2 3.5 (0.87) 1.7 (0.42) 7501 10,000 (2287 3048) 1, 2 3.5 (0.87) 1.7 (0.42) 0 4500 (0 1372) 10.0 (2.49) 4.9 (1.22) 4501 7500 (1373 2286) 2 10.0 (2.49) 4.9 (1.22) 7501 10,000 (2287 3048) 2 10.0 (2.49) 4.9 (1.22) 1 High ltitude Orifice Kit required, see Specifications table for order number. 2 High ltitude Pressure Kits required for 070, 110, 135 models, see Specifications table for order number. 3 LPG/Propane conversion kit required, see Specifications table for order number. Maximum Equivalent Vent Length Model No. G61MPV 36B 070 G61MPV 36C 090 1 G61MPV 60C 110 G61MPV 60D 135 ltitude G61MPV 60C 090 0 4,500 ft. 2 in. diameter 55 ft. (16.8 m) 25 ft. (7.6 m) 15 ft. (4.6 m) not allowed (0 1372 m) 3 in. diameter 70 ft. (21.3 m) 70 ft. (21.3 m) 70 ft. (21.3 m) 3 55 ft. (16.8 m) 4,501 10,000 ft. 2 in. diameter 55 ft. (16.8 m) 25 ft. (7.6 m) 15 ft. (4.6 m) not allowed (1372 3048 m) 3 in. diameter 70 ft. (21.3 m) 70 ft. (21.3 m) 70 ft. (21.3 m) 2, 3 40 ft. (12.2 m) NOTE Minimum Equivalent Vent Pipe length is 15 feet (4.6 m). 1 110 models installed in up flow or down flow applications must have the supplied 90 street ell installed directly into the unit flue collar. The street ell must be included in the elbow count. 2 Must have 3 in. to 2 in. reducing elbow (supplied) installed directly into the flue collar when installed in up flow or down flow configurations. Reducing ell must NOT be included in elbow count. 3 90 elbows must be limited to 3 in. sweep elbows. VENTING NOTES One 90 elbow is equivalent to 5 feet (1.5 m) of straight vent pipe. Two 45 elbows are equal to one 90 elbow. One 45 elbow is equivalent to 2.5 feet (762 mm) of straight vent pipe. One foot (305 mm) length of 2 in. (51 mm) diameter pipe is equivalent to 8 feet (2.4 m) of 3 in. (76 mm) diameter pipe. Wall and roof termination (non concentric) exhaust pipe must terminate with reducer to improve exhaust velocity away from intake piping. 070 2 or 3 in. terminate with 1 1/2 in. pipe 090 and 110 2 in. no change required 090 and 110 3 in. terminate with 2 in. pipe 135 3 in. terminate with 2 in. pipe G61MPV / Page 4

SPECIFICTIONS Gas Heating Performance Model No. G61MPV 36B 070 G61MPV 36C 090 High Fire Input Btuh (kw) 66,000 (19.3) 88,000 (25.8) Output Btuh (kw) 61,000 (17.9) 79,000 (23.1) Temperature rise range F ( C) 45 75 (25 42) 70 100 (39 56) Low Fire Input Btuh (kw) 45,000 (13.2) 60,000 (17.6) Output Btuh (kw) 43,000 (12.6) 57,000 (16.7) Temperature rise range F ( C) 25 55 (14 31) 35 65 (19 36) 1 FUE 94.1% 94.3% California Seasonal Efficiency 89.6% 91.2% High static (CS) in. w.g. (Pa) 0.8 0.8 Connections 2 Intake Pipe (PVC) 2 2 in. 2 Exhaust Pipe (PVC) 2 2 Indoor Blower Condensate Drain Trap (PVC pipe) i.d. 1/2 1/2 with field supplied (PVC coupling) o.d. 3/4 3/4 hose with hose clamp i.d. x o.d. 1 1/4 x 1 1 1/4 x 1 Gas pipe size IPS 1/2 1/2 Wheel nominal diameter x width in. (mm) 10 x 8 (254 x 203) 10 x 10 (254 x 254) Motor output hp (W) 1/2 (373) 1/2 (373) Tons (kw) of add-on cooling 2 3.5 (7 12.3) 2 3.5 (7 12.3) Shipping Data lbs. (kg) 1 package 151 (68) 170 (77) Electrical characteristics OPTIONL CCESSORIES MUST BE ORDERED EXTR 3, 4 ir Filter and Rack Kit Size of filter Horizontal (end) 87L96 18 x 25 x 1 in. (457 x 635 x 25 mm) Condensate Drain Heat Cable Side Return 120 volts 60 hertz 1 phase (less than 12 amps) 87L97 20 x 25 x 1 in. (508 x 635 x 25 mm) Single 44J22 or Ten Pack 66K63 16 x 25 x 1 in. (406 x 635 x 25 mm) 6 ft. (1.8 m) 26K68 26K68 24 ft. (7.3 m) 26K69 26K69 50 ft. (15.2 m) 26K70 26K70 Heat Cable Tape Fiberglass 1/2 in. (38 mm) x 66 ft. (20 m) 39G04 39G04 luminum foil 2 in. (25 mm) x 60 ft. (18 m) 39G03 39G03 4 EZ Filter Base Catalog Number Ship. Weight lbs. (kg) 73P56 7 (3) 73P57 8 (4) Dimensions H x W x D in. (mm) 4 x 17 5/8 x 28 5/8 (102 x 448 x 727) Size of field provided filter in. (mm) 16 x 25 x 1 (406 x 635 x 25) 4 x 21 5/8 x 28 5/8 (102 x 549 x 727) 20 x 25 x 1 (508 x 635 x 25) Down Flow dditive Base 11M60 11M61 5 High ltitude Orifice Kit Natural Gas 59M16 59M16 5 High ltitude Pressure Kit Order two each 56M23 Horizontal Support Frame Kit Ship. Weight lbs. (kg) 56J18 18 (8) 56J18 18 (8) LPG/Propane Kit 0 7500 ft. (0 2286 m) 59M13 59M13 7501 10,000 ft. (2286 3048 m) 59M14 59M14 6 LPG/Propane to Natural Gas Kit 59M87 59M87 SignatureStat Home Comfort Controller 51M27 51M27 7 Termination Concentric 1 1/2 inch (38 mm) 60G77 Kits 2 inch (51 mm) 33K97 Direct Vent pplications Only 3 inch (76 mm) 60L46 Wall Close Couple 2 inch (51 mm) 22G44 3 inch (76 mm) 44J40 44J40 Close Couple WTK 2 inch (51 mm) 30G28 7, 8 Termination Roof 2 inch (51 mm) 15F75 15F75 Kits Direct Vent or 3 inch (76 mm) 44J41 44J41 Non Direct Vent Wall Wall Ring Kit 2 inch (51 mm) 15F74 15F74 NOTE Filters and provisions for mounting are not furnished and must be field provided. 1 nnual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. 2 Determine from venting tables proper exhaust pipe size and termination kit required. 3 Cleanable polyurethane frame type filter. 4 Not for use with RB Return ir Base or with 60C and 60D size units with air flow requirements of 1800 cfm (850 L/s) or greater. See Blower Performance tables for additional information. 5 Required for proper operation at altitudes from 7501 to 10,000 ft. (2286 to 3048 m). 6 For applications from 7501 to 10,000 ft. (2286 to 3048 m), a High ltitude Orifice Kit will need to be ordered separately. 7 See Installation Instructions for specific venting information. 8 Kits contain enough parts for two, non direct vent installations. G61MPV / Page 5

SPECIFICTIONS Gas Heating Performance Model No. G61MPV 60C 090 G61MPV 60C 110 G61MPV 60D 135 High Fire Input Btuh (kw) 88,000 (25.8) 110,000 (32.2) 132,000 (38.7) Output Btuh (kw) 82,000 (24.0) 99,000 (29.0) 122,000 (35.7) Temperature rise range F ( C) 40 70 (22 39) 50 80 (28 44) 65 95 (36 53) Low Fire Input Btuh (kw) 60,000 (17.6) 75,000 (22.0) 90,000 (26.4) Output Btuh (kw) 55,000 (16.1) 72,000 (21.1) 87,000 (25.5) Temperature rise range F ( C) 20 50 (11 28) 30 60 (17 33) 40 70 (22 39) 1 FUE 94.6% 94.3% 94.6% California Seasonal Efficiency 89.0% 90.1% 91.3% High static (CS) in. w.g. (Pa) 0.8 0.8 0.8 Connections 2 Intake Pipe (PVC) 2 2 3 in. 2 Exhaust Pipe (PVC) 2 2 3 Indoor Blower Condensate Drain Trap (PVC pipe) i.d. 1/2 1/2 1/2 with field supplied (PVC coupling) o.d. 3/4 3/4 3/4 hose with hose clamp i.d. x o.d. 1 1/4 x 1 1 1/4 x 1 1 1/4 x 1 Gas pipe size IPS 1/2 1/2 1/2 Wheel nominal diameter x width in. (mm) 11 1/2 x 10 (292 x 229) 11 1/2 x 10 (292 x 229) 11 1/2 x 10 (292 x 229) Motor output hp (W) 1 (746) 1 (746) 1 (746) Tons (kw) of add-on cooling 3.5 5 (12.3 17.5) 3.5 5 (12.3 17.5) 3.5 5 (12.3 17.5) Shipping Data lbs. (kg) 1 package 180 (82) 188 (85) 207 (94) Electrical characteristics OPTIONL CCESSORIES MUST BE ORDERED EXTR 3, 4 ir Filter and Rack Kit Size of filter Horizontal (end) 87L97 20 x 25 x 1 in. (508 x 635 x 25 mm) Condensate Drain Heat Cable Side Return 120 volts 60 hertz 1 phase (less than 12 amps) 87L97 20 x 25 x 1 in. (508 x 635 x 25 mm) 87L98 25 x 25 x 1 in. (635 x 635 x 25 mm) Single 44J22 or Ten Pack (66K63) 16 x 25 x 1 in. (406 x 635 x 25 mm) 6 ft. (1.8 m) 26K68 26K68 26K68 24 ft. (7.3 m) 26K69 26K69 26K69 50 ft. (15.2 m) 26K70 26K70 26K70 Heat Cable Tape Fiberglass 1/2 in. (38 mm) x 66 ft. (20 m) 39G04 39G04 39G04 luminum foil 2 in. (25 mm) x 60 ft. (18 m) 39G03 39G03 39G03 4 EZ Filter Base Catalog Number Shipping Weight 73P57 8 (4) 73P58 10 lbs. (5 kg) 73P58 10 lbs. (5 kg) Dimensions H x W x D in. (mm) 4 x 21 5/8 x 28 5/8 (102 x 549 x 727) Size of field provided filter in. (mm) 20 x 25 x 1 (508 x 635 x 25) 4 x 24 5/8 x 28 5/8 (102 x 625 x 727) 24 x 24 x 1 (610 x 610 x 25) 4 x 24 5/8 x 28 5/8 (102 x 625 x 727) 24 x 24 x 1 (610 x 610 x 25) Down Flow dditive Base 11M61 11M61 11M62 5 High ltitude Orifice Kit Natural Gas Only 59M16 59M16 59M16 6 High ltitude Pressure Kit Order two each 56M23 56M93 Horizontal Support Frame Kit Ship. Weight lbs. (kg) 56J18 18 (8) 56J18 18 (8) 56J18 18 (8) LPG/Propane Kit 0 7500 ft. (0 2286 m) 59M13 59M13 59M13 7501 10,000ft. (2286 3048m) 59M14 59M14 59M14 7 LPG/Propane to Natural Gas Kit 59M87 59M87 59M87 RB Return ir Base RB60C (12M71) RB60C (12M71) RB60D (12M72) SignatureStat Home Comfort Controller 51M27 51M27 51M27 8 Termination Kits Concentric 2 inch (51 mm) 33K97 33K97 Direct Vent pplications 3 inch (76 mm) 60L46 60L46 60L46 Only Wall Close Couple 3 inch (76 mm) 44J40 44J40 44J40 8, 9 Termination Kits Roof 2 inch (51 mm) 15F75 15F75 Direct Vent or Non 3 inch (76 mm) 44J41 44J41 44J41 Direct Vent Wall Ring Kit 2 inch (51 mm) 15F74 15F74 10 15F74 NOTE Filters and provisions for mounting are not furnished and must be field provided. 1 nnual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. 2 Determine from venting tables proper exhaust pipe size and termination kit required. 3 Cleanable polyurethane frame type filter. 4 Not for use with RB Return ir Base or with 60C and 60D size units with air flow requirements of 1800 cfm (850 L/s) or greater. See Blower Performance tables for additional information. 5 Required for proper operation at altitudes from 7501 to 10,000 ft. (2286 to 3048 m). 6 Required for proper operation at altitudes from 4501 to 10,000 ft. (1370 to 3048 m). 7 For applications from 7501 to 10,000 ft. (2286 to 3048 m), a High ltitude Orifice Kit will need to be ordered separately. 8 See Installation Instructions for specific venting information. 9 Kits contain enough parts for two, non direct vent installations. 10 Non direct vent applications only. G61MPV / Page 6

FILTER RESISTNCE For 1 Inch (25 mm) Cleanable Filter (Field Provided) cfm L/s in. w.g. Pa 0 0 0.00 0 200 95 0.01 0 400 190 0.03 5 600 285 0.04 10 800 380 0.06 15 1000 470 0.09 20 1200 565 0.12 30 1400 660 0.15 35 1600 755 0.19 45 1800 850 0.23 55 2000 945 0.27 65 2200 1040 0.33 80 2400 1130 0.38 95 2600 1225 0.44 110 INSTLLTION CLERNCES Sides Rear Top/Plenum Front Front (service/alcove) Floor 1 0 inches (0 mm) 0 inches (0 mm) 1 inch (25 mm) 0 inches (0 mm) 24 inches (610 mm) 2 Combustible NOTE ir for combustion and supply air ventilation must conform to the methods outlined in merican National Standard (NSI-Z223.1) National Fuel Gas Code or National Standard of Canada CN/CG-149.1, & CN/CG-149.2 Installation Code for Gas Burning ppliances". NOTE In the U.S. flue sizing must conform to the methods outlined in current GM/.G.. venting tables, merican National Standard (NSI-Z223.1) National Fuel Gas Code or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CN/ CG-149.1 and.2. 1 llow proper clearances to accommodate condensate trap and vent pipe installation. 2 Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring. INSTLLTION CONFIGURTIONS VENT PIPING UP FLOW FLOW DOWN FLOW HORIZONTL RIGHT VENT PIPING HET EXCHNGER BLOWER BLOWER HET EXCHNGER FLOW VENT PIPING CONDENSTE DRIN HORIZONTL LEFT CONDENSTE DRIN BLOWER HET EXCHNGER VENT PIPING FLOW CONDENSTE DRIN FLOW HET EXCHNGER BLOWER NOTE On up flow and down flow configurations, the vent piping and condensate drain can be moved to the other side of the unit. Vent piping and drain must be installed on the same side of the unit with each other. On horizontal installations the drain must be located at the bottom and the vent piping at the top. CONDENSTE DRIN G61MPV / Page 7

DIMENSIONS INCHES (MM) UP FLOW POSITION SHOWN 1 NOTE 60C and 60D size units that require air volumes over 1800 cfm (850 L/s) must have one of the following: a. Single side return air with transition, to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) air filter. Required to maintain proper air velocity. b. Single side return air with optional RB Return ir Base c. Bottom return air. d. Return air from both sides. e. Bottom and one side return air. SUPPLY OPENING See Blower Performance Tables for additional information. 2 Optional External Side Return ir Filter Kit (Up Flow Only) is not for use with the optional RB Return ir Base. 2 OPTIONL EXTERNL SIDE RETURN FILTER KIT B 9/16 (14) 5 1/2 (140) 6 1/2 (165) 23-3/4 (603) 25 (635) TOP VIEW 28 1/2 (724) 19 7/16 (378) 9/16 (14) 2 OPTIONL EXTERNL SIDE RETURN FILTER KIT 40 (1016) 11 5/8 (295) Right 9 3/4 (248) Left 6 1/2 (165) 4 1/8 (103) 4 7/8 (124) Right 2 1/4 (57) Left 6 3/4 (171) 2 1/2 (64) 3 1/8 (79) COMBUSTION INTKE EXHUST OUTLET GS PIPING INLET CONDENSTE TRP CONNECTION ELECTRICL INLET FLOW 14 3/4 (375) 16 (406) 18-3/4 (476) 4 (102) 23 (584) 1 OPTIONL RETURN CUTOUT Up Flow Only 14 (356) 1 15/16 (49) 3/4 (19) C 3/4 (19) 1 Bottom Return ir Opening FRONT VIEW 5/8 (16) 4 1/4 (108) 23 1/2 (597) 1 Bottom Return ir Opening SIDE VIEW Model No. B C in. mm in. mm in. mm G61MPV 36B 070 17 1/2 446 16 3/8 416 16 406 G61MPV 36C 090 G61MPV 60C 090 21 533 19 7/8 454 19 1/2 495 G61MPV 60C 110 G61MPV 60D 135 24 1/2 622 23 3/8 546 23 584 G61MPV / Page 8

DIMENSIONS INCHES (MM) FURNCE/COIL COMBINTIONS UP FLOW POSITION DOWN FLOW POSITION 40 (1016) B HORIZONTL B 40 (1016) B 40 (1016) Up Flow Uncased Model No. B in. mm in. mm C33 24B 2 13 7/8 352 53 7/8 1368 C33 30B 2 17 3/4 451 57 3/4 1467 C33 48B 2 22 1/8 562 62 1/8 1578 C33 36B 2 21 7/8 556 61 7/8 1572 C33 36C 2 21 1/4 540 61 1/4 1556 C33 38B 2 22 559 62 1575 C33 42B 2 21 7/8 556 61 7/8 1572 C33 44C 2, C33 48C 2 21 1/2 546 61 1/2 1562 C33 50/60C 2, C33 60D 2 24 3/4 629 64 3/4 1645 C33 62D 2 28 3/4 730 68 3/4 1746 Up Flow Cased C33 24B 2F, CX34 18/24B 6F 16 1/2 419 56 1/2 1435 C33 30B 2F, CX34 30B 6F 20 1/2 521 60 1/2 1537 C33 36B 2F, C33 36C 2F, C33 38B 2F, C33 42B 2F, C33 44C 2F, C33 48B 2F, C33 48C 2F, CX34 36B 6F, CX34 36C 6F, CX34 38B 6F, CX34 42B 6F, CX34 44/48C 6F, CX34 44/48B 6F 24 1/2 622 64 1/2 1638 C33 50/60C 2F, CX34 50/60C 6F 27 1/2 699 67 1/2 1715 C33 60D 2F, CX34 60D 6F 25 1/2 648 65 1/2 1664 C33 62D 2F, CX34 62D 6F 29 1/2 749 69 1/2 1765 Model No. B in. mm in. mm Horizontal Cased CH33 36B 2F 26 1/2 673 66 1/2 1689 CH33 36C 2F 26 1/2 673 66 1/2 1689 CH33 42B 2F 26 1/2 673 66 1/2 1689 CH33 44/48B 2F 31 1/2 800 71 1/2 1816 CH33 48C 2F 26 1/2 673 66 1/2 1689 CH33 50/60C 2F 31 1/2 800 71 1/2 1816 CH33 60D 2F 26 1/2 673 66 1/2 1689 CH33 62D 2F 31 1/2 800 71 1/2 1816 Down Flow Cased CR26 18N F 12 3/4 324 52 3/4 1340 CR26 30N F 12 3/4 324 52 3/4 1340 CR26 36N F 15 3/8 391 55 3/8 1407 CR26 36W F 15 3/8 391 55 3/8 1407 CR26 48N F 19 1/8 486 59 1/8 1502 CR26 48W F 19 1/8 486 59 1/8 1502 CR26 60N F 22 7/8 581 62 7/8 1597 CR26 60W F 22 7/8 581 62 7/8 1597 G61MPV / Page 9

OPTIONL CCESSORY DIMENSIONS INCHES (MM) RB RETURN BSE (Up Flow pplications Only) For use with 60C and 60D size furnaces only FLOW 3 1/4 (83) OPTIONL RETURN BSE SIDE RETURN OPENINGS 4 (102) 1 23 Overall (584) *Unit Opening 1 Base Opening 14 (356) 1 18 1/2 (470) Overall 21 (533) RB60C 7/8 (22) 20 1/2 (521) 27 5/8 (702) 24 1/2 (622) RB60D FRONT VIEW SIDE VIEW 1 NOTE Both return air openings must be covered by a single plenum. Overall opening dimensions: 23 (584) W X 18 1/2 (470) H. Optional Side Return ir Filter Kits are not for use with RB Return ir Base. DOWN-FLOW DDITIVE FLOOR BSE 3/4 (19) 1-1/2 (38) DOWN FLOW FURNCE 1-1/2 (38) SUPPLY OPENING 19-13/16 (503) B 1-1/2 (38) 27-1/4 (692) 21-13/16 (554) Front Of Furnace 1-1/2 (38) DOWN-FLOW DDITIVE FLOOR BSE TOP VIEW SIDE VIEW FLOOR OPENING 22 (559) C Model No. B C in. mm in. mm in. mm G61MPV 36B 070 19 9/16 497 16 9/16 421 18 3/4 476 G61MPV 36C 090 G61MPV 60C 090 G61MPV 60C 110 23 1/16 586 20 1/16 510 22 1/4 565 G61MPV 60D 135 26 9/16 675 23 9/16 598 25 3/4 654 G61MPV / Page 10

OPTIONL CCESSORY DIMENSIONS INCHES (MM) HORIZONTL FILTER KIT 24 3/4 (629) 5/8 (16) 1-1/4 (32) B RETURN OPENING 5/8 (16) FLOW Catalog Number B inch mm inch mm 87L96 18 457 16 3/4 425 87L97 21 533 18 3/4 476 87L98 25 635 23 3/4 603 5/8 (16) 5/8 (16) 23 1/2 (597) SIDE VIEW FILTER (Furnished) FRONT VIEW CONCENTRIC WLL TERMINTION PPLICTIONS CONCENTRIC ROOF TERMINTION PPLICTIONS EXHUST OUTSIDE WLL 10-1/2 (267) INTKE EXHUST 12 (305) Minimum bove verage Snow ccumulation FLSHING INTKE INTKE GRDE 12 (305) Minimum bove Grade CLMP SHEET METL STRP (Clamp and sheet metal strap must be field installed to support the weight of the termination kit.) 60G77 1 1/2 inch (38 mm) 33K97 2 inch (51 mm) See Installation Instructions for specific usage. 60L46 3 inch (76 mm) See Installation Instructions for specific usage. 2 x 1-1/2 in. (51 x 38 mm) 60G77 3 x 2 in. (76 x 51 mm) 33K97 REDUCER BUSHING (Furnished) 37 (940) INTKE 46 3/4 (1187) 6 1/2 (165) 3 (76) 4 1/2 (114) ELBOW (Furnished) CLMP (Furnished) INTKE TERMINTION SSEMBLY (Furnished) EXHUST ELBOW (Field Supplied) TERMINTION SSEMBLY (Furnished) INTKE EXHUST G61MPV / Page 11

OPTIONL CCESSORY DIMENSIONS INCHES (MM) WLL SSEMBLY TERMINTION KIT RING KIT 15F74 2 inch (51 mm) See Installation Instructions for specific usage. DIRECT VENT PPLICTION NOTE 12 in. (305 mm) minimum height above average snow accumulation. NON DIRECT VENT PPLICTION NOTE EXHUST PIPE SHOWN Kit Contains Enough Parts For Two Installations NOTE 12 in. (305 mm) minimum height above average snow accumulation. 12 in. (305 mm) maximum without support 12 in. (305 mm) maximum without support 8 in. (203 mm) minimum 6 in. (152 mm) maximum 12 (305) DIRECT VENT PPLICTIONS WLL TERMINTION KITS (CLOSE-COUPLE) 22G44 2 inch (51 mm) 44J40 3 inch (76 mm) See Installation Instructions for specific usage. If Intake and Exhaust Pipe is less than 12 in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. EXHUST INTKE EXHUST INSULTION (Not Furnished) INTKE 5 (127) 5-1/2 (140) GRDE ÉÉÉÉÉÉÉÉÉÉÉÉ 12 (305) 2 (51) 12 (305) 12 (305) Minimum BOVE GRDE GRDE ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ G61MPV / Page 12

OPTIONL CCESSORY DIMENSIONS INCHES (MM) 12 (305) DIRECT VENT PPLICTIONS WTK WLL SSEMBLY TERMINTION KIT WITH FIELD FBRICTION BOVE GRDE EXTENDED CLERNCE 30G28 2 inch (51 mm) See Installation Instructions for specific usage. If Intake and Exhaust Pipe is less than 12 in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. EXHUST INTKE 5 (127) 5-1/2 (140) EXHUST GRDE INSULTION (Not Furnished) INTKE 8 (203) Minimum 12 (305) 12 (305) Maximum GRDE Minimum BOVE GRDE BLOWER DT G61MPV 36B 070 PERFORMNCE 0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range DJUST" Second Stage HET" Speed 1 1 2 3 4 1 2 3 1 4 + 915 430 1315 620 1320 620 1370 645 1055 495 1225 580 1315 620 1435 675 1 NORM 830 390 960 455 1190 560 1240 585 935 440 1095 515 1185 560 1300 615 735 345 845 400 1050 495 1085 510 835 395 960 455 1050 495 1145 540 First Stage HET" Speed DJUST" + 825 390 965 455 1195 565 1245 585 690 325 770 365 820 386 890 420 1 NORM 755 355 865 410 1070 505 1115 525 635 300 715 335 750 355 810 380 695 325 780 370 935 440 985 465 600 285 645 305 680 320 725 340 G61MPV 36C 090 PERFORMNCE 0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range DJUST" Second Stage HET" Speed 1 1 2 3 4 1 2 3 1 4 + N/ N/ 1015 480 1235 580 1290 610 1010 475 1150 540 1230 580 1355 640 1 NORM N/ N/ 925 435 1120 530 1170 550 920 435 1045 495 1120 530 1230 580 N/ N/ 830 390 1010 475 1055 495 825 390 940 445 1010 475 1110 525 DJUST" First Stage HET" Speed + N/ N/ 945 445 1130 535 1175 555 765 360 845 400 895 420 940 445 1 NORM N/ N/ 860 405 1030 485 1070 505 695 325 770 365 810 380 855 405 N/ N/ 770 365 925 435 960 455 625 295 695 325 730 345 770 360 1 Factory default jumper setting. The effect of static pressure is included in air volumes shown. First stage HET is approximately 91% of the same second stage HET speed position. First stage COOL (two stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position minimum 500 cfm (235 L/s). Lennox Harmony zone control applications Minimum blower heating speed is approximately 75% of the second stage HET speed position and the minimum blower cooling speed is approximately 45% of the second stage COOL speed position. G61MPV / Page 13

BLOWER DT G61MPV 60C 090 PERFORMNCE 0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range Bottom Return ir, Return ir from Both Sides or Return ir from Bottom and One Side. DJUST" Second Stage HET" Speed + 1480 700 1685 795 1870 880 2075 980 1580 745 1715 810 1925 910 2155 1015 1 NORM 1345 635 1525 720 1725 815 1890 890 1445 680 1560 735 1750 825 1955 920 1195 565 1355 640 1515 715 1695 800 1270 600 1380 650 1570 740 1760 830 DJUST" First Stage HET" Speed + 1360 640 1520 715 1705 805 1900 895 1100 520 1180 555 1340 630 1520 715 1 NORM 1220 575 1395 660 1560 735 1720 810 1000 470 1070 505 1210 570 1360 640 1100 520 1240 585 1410 665 1535 725 885 415 965 455 1090 515 1210 570 Single Side Return ir ir volumes in bold require field fabricated transition to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity across the filter. DJUST" Second Stage HET" Speed + 1440 680 1630 770 1810 855 2015 950 1585 745 1665 785 1870 880 2100 990 1 NORM 1315 620 1490 705 1675 790 1845 870 1400 660 1565 740 1715 810 1920 905 1170 550 1315 620 1525 720 1650 780 1245 585 1345 635 1600 755 1710 805 DJUST" First Stage HET" Speed + 1315 620 1555 735 1740 820 1850 875 1090 515 1155 545 1315 620 1480 700 1 NORM 1200 565 1360 640 1565 740 1755 830 990 465 1055 495 1185 560 1370 645 1080 510 1205 570 1360 640 1575 745 870 410 935 440 1070 505 1195 565 Side Return ir with Optional RB Return ir Base DJUST" Second Stage HET" Speed + 1455 685 1640 775 1865 880 2070 975 1565 740 1675 790 1915 905 2135 1005 1 NORM 1320 620 1490 705 1695 800 1880 885 1420 670 1520 715 1740 820 1940 915 1190 560 1340 630 1530 720 1690 795 1280 605 1370 645 1570 740 1745 825 DJUST" First Stage HET" Speed + 1325 625 1510 710 1695 800 1870 880 1085 510 1165 550 1310 620 1465 690 1 NORM 1205 570 1375 650 1540 725 1700 800 985 465 1060 500 1190 560 1335 630 1085 510 1235 580 1385 655 1530 720 890 420 955 450 1070 505 1200 565 1 Factory default jumper setting. The effect of static pressure is included in air volumes shown. First stage HET is approximately 91% of the same second stage HET speed position. First stage COOL (two stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position minimum 500 cfm (235 L/s). Lennox Harmony zone control applications Minimum blower heating speed is approximately 75% of the second stage HET speed position and the minimum blower cooling speed is approximately 45% of the second stage COOL speed position. N/ HET" speed, position 1 cannot be used with this model. G61MPV / Page 14

Blower Data G61MPV 60C 110 PERFORMNCE 0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range Bottom Return ir, Return ir from Both Sides or Return ir from Bottom and One Side. DJUST" Second Stage HET" Speed + 1520 715 1705 805 1895 895 2105 995 1610 760 1725 815 1940 915 2170 1025 1 NORM 1365 645 1545 730 1735 820 1895 895 1460 690 1575 745 1765 830 1970 930 1225 580 1390 655 1570 740 1730 815 1300 615 1400 660 1600 755 1770 835 DJUST" First Stage HET" Speed + 1380 650 1575 745 1755 830 1945 915 1090 515 1165 550 1320 620 1490 705 1 NORM 1240 585 1435 915 1605 755 1780 840 990 465 1060 500 1200 565 1355 640 1115 525 1250 590 1425 670 1590 750 890 420 955 450 1080 510 1220 575 Single Side Return ir ir volumes in bold require field fabricated transition to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity across the filter. DJUST" Second Stage HET" Speed + 1475 695 1650 780 1805 850 1995 940 1575 745 1690 795 1880 885 2110 995 1 NORM 1335 630 1510 710 1695 800 1830 865 1420 670 1535 725 1715 810 1910 900 1170 550 1330 625 1490 7605 1630 770 1270 600 1365 645 1575 745 1735 820 DJUST" First Stage HET" Speed + 1345 635 1510 710 1665 785 1845 870 1060 500 1135 535 1300 615 1420 670 1 NORM 1210 70 1400 660 1565 740 1710 805 965 455 1030 485 1180 555 1290 610 1085 510 1230 580 1405 665 1535 725 870 410 930 440 1060 500 1160 545 Side Return ir with Optional RB Return ir Base DJUST" Second Stage HET" Speed + 1460 670 1650 780 1835 865 2050 965 1560 735 1660 785 1905 900 2125 1000 1 NORM 1330 625 1510 710 1675 790 1855 875 1420 670 1510 710 1730 815 1930 910 1175 555 1335 630 1495 705 1655 780 1275 600 1360 640 1555 735 1740 820 DJUST" First Stage HET" Speed + 1340 630 1530 720 1700 800 1875 885 1080 510 1165 550 1315 620 1475 695 1 NORM 1205 570 1380 650 1550 730 1705 805 980 460 1055 495 1195 565 1340 630 1095 515 1215 575 1380 650 1525 720 885 415 950 450 1080 510 1205 570 1 Factory default jumper setting. The effect of static pressure is included in air volumes shown. First stage HET is approximately 91% of the same second stage HET speed position. First stage COOL (two stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position minimum 500 cfm (235 L/s). Lennox Harmony zone control applications Minimum blower heating speed is approximately 75% of the second stage HET speed position and the minimum blower cooling speed is approximately 45% of the second stage COOL speed position. G61MPV / Page 15

BLOWER DT G61MPV 60D 135 PERFORMNCE 0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range Bottom Return ir, Return ir from Both Sides or Return ir from Bottom and One Side. DJUST" Second Stage HET" Speed + 1485 700 1690 795 1905 900 2105 995 1585 745 1725 815 1955 920 2185 1030 1 NORM 1345 635 1535 725 1735 820 1915 905 1435 675 1570 740 1780 840 1990 940 N/ N/ 1370 645 1560 735 1720 810 1290 610 1405 665 1600 755 1780 840 DJUST" First Stage HET" Speed + 1340 630 1525 720 1730 815 1925 910 1095 515 1180 555 1335 630 1495 705 1 NORM 1215 575 1380 650 1570 740 1750 825 995 470 1075 505 1205 570 1345 635 N/ N/ 1235 580 1410 665 1575 745 890 420 960 455 1085 510 1205 570 Single Side Return ir ir volumes in bold require field fabricated transition to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity across the filter. DJUST" Second Stage HET" Speed + 1420 670 1585 745 1780 840 1965 925 1515 715 1610 760 1825 860 2040 960 1 NORM 1290 610 1440 680 1615 760 1785 840 1380 650 1465 690 1660 785 1855 875 N/ N/ 1295 610 1455 685 1605 755 1240 585 1315 620 1495 705 1670 790 DJUST" First Stage HET" Speed + 1285 605 1460 690 1645 775 1810 855 1045 495 1130 535 1275 600 1400 660 1 NORM 1170 550 1325 625 1495 705 1645 775 950 450 1030 485 1155 545 1270 600 N/ N/ 1195 565 1345 635 1480 700 855 405 925 435 1040 490 1145 540 Side Return ir with Optional RB Return ir Base DJUST" Second Stage HET" Speed + 1440 680 1600 755 1800 850 1980 935 1540 725 1640 775 1850 875 2075 980 1 NORM 1305 615 1455 685 1635 770 1800 850 1400 660 1490 705 1685 795 1890 890 N/ N/ 1310 620 1470 695 1620 765 1260 595 1340 630 1515 715 1700 800 DJUST" First Stage HET" Speed + 1315 620 1490 705 1665 785 1835 865 1070 505 1155 545 1300 615 1425 670 1 NORM 1195 565 1355 640 1515 715 1670 790 975 460 1050 495 1180 555 1295 610 N/ N/ 1220 575 1365 645 1505 710 875 410 945 445 1065 500 1170 550 1 Factory default jumper setting. The effect of static pressure and is included in air volumes shown. First stage HET is approximately 91% of the same second stage HET speed position. First stage COOL (two stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position minimum 500 cfm (235 L/s). Lennox Harmony zone control applications Minimum blower heating speed is approximately 75% of the second stage HET speed position and the minimum blower cooling speed is approximately 45% of the second stage COOL speed position. N/ HET" speed, position 1 with MINUS" adjust cannot be used with this model. G61MPV / Page 16