Zoning:CS FLU: LI/CS 4,709.21 SF 21,120 SF 24.5' HT Proposed Usable Open Space (120 SF) 4,774 SF 4,014.01 SF 15.5' HT 4,655.61 SF 15.5' HT Proposed Bike Rack RAMP Proposed 3" Concrete Ballard BUILDING 2 7,240.02 SF BUILDING 1 3,500 SF / Zoning: CS FLU: LI/CS 14,408 SF 13,275.13 SF BUILDING 2 7,240.02 SF BUILDING 1 3,500 SF / Zoning: RS-2 FLU: LI/CS Zoning: RS-2 FLU: LI/CS Detail Site Plan of Expansion on Sheet 2 & 3 Vacuum Truck Area (10'x45') P 2-in FM P 2-in FM FLU: LI/CS Zoning:CS Site Data: Total Area: Impervious Area: Total Building Footprint: Vehicular Use Area: Pervious Area: Landscape Area: Existing Zoning: 203,750 sf 156,999 sf 76,815.98 sf 80,183.02 sf Future Land Use Designation: Existing Use: Building Data Gross Floor Area: Storage Area: Office: 4.67 ac. 3.60 ac. 1.76 ac. 1.84 ac. 46,751 sf 1.07 ac. 46,751 sf 1.07 ac. CS LI/CS Storage Facility 106,735.98 s.f. Maximum Height: 35' Proposed Height: 35' Building Coverage: 38 % Vehicular Use Area: 39 % Landscape Area: 23 % Building Setback Requirements Front (South west): Rear (North east): Side (North west): Side (South east): Parking Requirements Total Parking: Existing Parking: Expansion Phase 2 Parking: Handicap Parking Provided: 105,935.98 sf 800 sf Required Provided 10' 24.33' 21.41' 16 Spaces 12 Spaces 4 Spaces 2 Spaces 100% 77% 23% 701 E Ocean Blvd., Stuart, Florida 34994 100 Avenue A Suite 2A, Fort Pierce, Florida 34950 827 North Thornton Avenue, Orlando, Florida 32803 Key / Location: PROJECT SITE Project Team: Client & Property Owner: Land Planner / Landscape Architect: Engineer: Surveyor: (772) 220-2100, Fax (772) 223-0220 (772) 467-1301, Fax (772) 467-1303 (407) 898-9521, Fax (407) 898-9768 N.T.S. American Personal Storage 1849 SW South Macedo Blvd Port St. Lucie, FL 34984 Lucido & Associates 701 E Ocean Boulevard Stuart, FL 34994 Engineering Design & Construction 1934 Tucker Court Fort Pierce, FL 34950 Bloomster Surveying, Inc. 641 NE Spencer St Jensen Beach, FL 34957 18' 5' Zoning:RS-4 FLU: RL 2' 9.5' Sidewalk Wheel Stop 4-1/8" 48-1/8" 36" (8) 3/8" x 1-1/2" SOLID STEEL SUPPORTS 21-7/8" General Notes: - All landscape areas abutting vehicular use areas shall be curbed or protected by curb stops. - All building, parking and access areas shall document compliance with the requirements of the American Disabilities Act prior to the issuance of a building permit. - Proposed light poles shall be shielded to minimize excess glare to adjacent residential areas and roadways. - Soil erosion and sediment control devices shall be in place prior to the comencement of construction activities. - Landscaping shall be in accordance with the requirements of chapter 154 of the landscape code of the City of Port St. Lucie. - No landscaping other than grasses shall be located within 10' of a City utility line or appurtenance. All other utilities shall be a minimum of 5' horizontal separation from City utility mains for parallel installations and a minimum 18" below City mains. (All measurements ae take from outside to outside.) - No landscaping shall be placed in a manner that would create conflicts with the intended operation and maintenance of any existing utility. - This application is not vested for any municipal fees. All fees are calculated at time of payment. This includes specifically impact fees, upland preserve fees and any administrative review fees for City Departments. No fees are vested based on date of City Council approval. - Signs are not part of this review and shall be permitted separately from this application. (See Chapter 155 (Sign Code) City of Port St Lucie Land Development Regulations and Section III of the Architectural Designs Standards.) -Public art requirement will be due at time of building permit application for phase 2. -Handicapped parking improvement, bike rack, and public open space will be implemented with phase 2. Architect: Patrick M Pillot Architect, Inc. 1267 2nd St Sarasota, FL 34236 American Personal Storage City of Port St. Lucie, FL Site Plan P#16-121 16' 6' 9.5' 2' Overhang 18' 4" White Double Stripe Sidewalk Type 'D' Curb 18' 18' 2-3/8" O.D. TUBULAR STEEL 14-1/4" 19-1/2"CENTER-TO-CENTER Legal Description: LOTS 4-14, 17-25, BLOCK 626, PORT ST. LUCIE SECTION THIRTEEN, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 13, PAGE(S) 4, 4A THROUGH 4M, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. Wellfield Protection: It has been confirmed the project is not within the zone of protection per the City's wellfield protection ordinance. Date By Description 07.20.16 TJ Initial Submittal 10.05.16 TJ Resubmittal 11.16.16 TJ Resubmittal 03.03.17 TJ Response to Comments 03.10.17 TJ Response to Comments 4" White Double Stripe 9.5' Drainage: This project includes the expansion of the existing detention area currently serving the previous phases of the project. The detention area expansion will be sized to accommodate the proposed new building and driveway. The expansion of the detention area will be built in phase 1 of the project. NORTH SCALE: 1" = 40' 8' Ht. 0 20' 40' 80' REG. # 1018 Thomas P. Lucido Designer Manager Project Number Municipal Number Computer File TRJ Sheet SDG 15-170 --- 15-170 American Personal Storage-Final SitePlan C
Site Data: Total Area: Impervious Area: Vehicular Use Area: Pervious Area: Landscape Area: Existing Zoning: 23,958 sf 16,157 sf 16,157 sf Future Land Use Designation: Existing Use: 0.55 ac. 0.37 ac..37 ac. 7,801 sf 0.18 ac. 7,801 sf 0.18 ac. CS LI/CS Vacant 100% 67% 33% 701 E Ocean Blvd., Stuart, Florida 34994 100 Avenue A Suite 2A, Fort Pierce, Florida 34950 827 North Thornton Avenue, Orlando, Florida 32803 Key / Location: (772) 220-2100, Fax (772) 223-0220 (772) 467-1301, Fax (772) 467-1303 (407) 898-9521, Fax (407) 898-9768 13,275.13 SF Zoning: RS-2 FLU: LI/CS 6' Existing Fence (Proposed to be screened/opaque) Zoning: RS-2 FLU: LI/CS General Notes: - All landscape areas abutting vehicular use areas shall be curbed or protected by curb stops. - All building, parking and access areas shall document compliance with the requirements of the American Disabilities Act prior to the issuance of a building permit. - Proposed light poles shall be shielded to minimize excess glare to adjacent residential areas and roadways. - Soil erosion and sediment control devices shall be in place prior to the commencement of construction activities. - Landscaping shall be in accordance with the requirements of chapter 154 of the landscape code of the City of Port St. Lucie. - No landscaping other than grasses shall be located within 10' of a City utility line or appurtenance. All other utilities shall be a minimum of 5' horizontal separation from City utility mains for parallel installations and a minimum 18" below City mains. (All measurements are take from outside to outside.) - No landscaping shall be placed in a manner that would create conflicts with the intended operation and maintenance of any existing utility. - This application is not vested for any municipal fees. All fees are calculated at time of payment. This includes specifically impact fees, upland preserve fees and any administrative review fees for City Departments. No fees are vested based on date of City Council approval. - Signs are not part of this review and shall be permitted separately from this application. (See Chapter 155 (Sign Code) City of Port St Lucie Land Development Regulations and Section III of the Architectural Designs Standards.) -Public art requirement will be due at time of building permit application for phase 2. PROJECT SITE Project Team: N.T.S. 14,408 SF BUILDING 2 7,240.02 SF Existing Retention BUILDING 1 3,500 SF / Existing APS Site 13.61' On Site Access Existing Pump Slab 8' Proposed opaque Fence (8' Ht. from FFE) 20'U.E. Existing Fence (to be removed) 10' Proposed Opaque Fence (8' Ht. from FFE) Outdoor Storage Expansion (Shellrock Stabilized Surface 14,358.37 SF) 12' U.E. 161.33' Existing FPL Pole Light Proposed Detention 3,286 SF(13.9%) Existing FPL Pole Light 89' 10' 101.49' SE Voltair Terrace FLU: LI/CS Zoning:CS Drainage Note: THIS PROJECTS INCLUDES THE EXPANSION OF THE EXISTING DETENTION AREA CURRENTLY SERVING THE PREVIOUS PHASES OF THE PROJECT. THE DETENTION AREA EXPANSION WILL BE SIZED TO ACCOMMODATE THE PROPOSED NEW BUILDING AND DRIVEWAY.THE STABILIZED AREA WILL BE SLOPED TO DRAIN TO THE RETENTION AREA FOR PHASE 1. Legal Description: LOTS 4-14, 17-25, BLOCK 626, PORT ST. LUCIE SECTION THIRTEEN, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 13, PAGE(S) 4, 4A THROUGH 4M, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. Existing Fence On Site Proposed 8' Opaque Fence Client & Property Owner: Land Planner / Landscape Architect: Engineer: Surveyor: Architect: American Personal Storage 1849 SW South Macedo Blvd Port St. Lucie, FL 34984 Lucido & Associates 701 E Ocean Boulevard Stuart, FL 34994 Engineering Design & Construction 1934 Tucker Court Fort Pierce, FL 34950 Bloomster Surveying, Inc. 641 NE Spencer St Jensen Beach, FL 34957 Patrick M Pillot Architect, Inc. 1267 2nd St Sarasota, FL 34236 American Personal Storage City of Port St. Lucie, FL Site Plan Phase 1 P#16-121 Date By Description 07.20.16 TJ Initial Submittal 10.05.16 TJ Resubmittal 11.16.16 TJ Resubmittal 03.03.17 TJ Response to Comments 03.10.17 TJ Response to Comments SW South Macedo Blvd NORTH SCALE: 1" = 20' 0 10' 20' 40' REG. # 1018 Thomas P. Lucido Designer Manager Project Number Municipal Number Computer File TRJ Sheet SDG 15-170 --- 15-170 American Personal Storage-Final SitePlan C
Site Data: Zoning: RS-2 FLU: LI/CS Zoning: RS-2 FLU: LI/CS Proposed Connection to Existing 3" LPM Existing 16" Water Main Total Area: Impervious Area: Building Footprint: Vehicular Use Area: Pervious Area: Landscape Area: Existing Zoning: 23,958 sf 16,155 sf 9,680 sf 6,477 sf Future Land Use Designation: Existing Use: Building Data Gross Floor Area: 0.55 ac. 0.37 ac..22 ac..15 ac. 7,803 sf 0.18 ac. 7,803 sf 0.18 ac. CS LI/CS Vacant 29,040 s.f. Maximum Height: 35' Proposed Roof Height: 34' 8" Overall Proposed Height (includes parapet): 38' Building Coverage: 40% Vehicular Use Area: 27% Landscape Area: 33% 100% 67% 33% Building Setback Requirements 701 E Ocean Blvd., Stuart, Florida 34994 100 Avenue A Suite 2A, Fort Pierce, Florida 34950 827 North Thornton Avenue, Orlando, Florida 32803 Key / Location: PROJECT SITE (772) 220-2100, Fax (772) 223-0220 (772) 467-1301, Fax (772) 467-1303 (407) 898-9521, Fax (407) 898-9768 Required Provided 14,408 SF 13,275.13 SF BUILDING 2 7,240.02 SF Existing Retention BUILDING 1 3,500 SF / Existing APS Site 13.61' 6' Existing Fence (Proposed to be screened/opaque) On Site Access Existing Pump Slab 8' Proposed opaque Fence (8' Ht. from FFE) 20'U.E. Existing Fence 1 (to be removed) 10' 30' 9.50' 8' Proposed Opaque Wall (Concrete) 18' Storage Expansion 3 Story 29,040 SF (9,680 SF/ Floor) (268 Bays) 21.00 FFE 161.33' Existing FPL Pole Light 60.00' 40' 2 3 4 12' U.E. Proposed Detention 3,286 SF(13.9%) INSTALL CULVERT WITH MES., LENGTH, SIZE, MATERIAL, & ELEVATIONS TO BE PROVIDED BY THE CITY OF PORT ST. LUCIE PUBLIC WORKS DEPARTMENT Existing FPL Pole Light Emergency Access Only (Opaque Gate) Vacuum Truck Area (10'x45') 20' x 20' 8' Proposed opaque Fence (8' Ht. from FFE) P.O.S. Utility Easement (Grinder Station) 10' U.E. P.O.S. Lift Station 10' U.E. 10' U.E. 101.49' Existing 2" Force Main SE Voltair Terrace Existing 2" Force Main P 2-in FM P 2-in FM Proposed 2" Force Main FLU: LI/CS Zoning:CS Proposed 2" Force Main Proposed 2" Tee, Gate valve & Check Valve Front: Rear: Side (adjacent to R/W): Side (interior to existing building): Parking Requirements Parking Required: Parking Provided: 10' Existing Fence On Site Proposed 8' Opaque Fence 40' 13.61' 3 Spaces 4 Spaces General Notes: - All landscape areas abutting vehicular use areas shall be curbed or protected by curb stops. - All building, parking and access areas shall document compliance with the requirements of the American Disabilities Act prior to the issuance of a building permit. - Proposed light poles shall be shielded to minimize excess glare to adjacent residential areas and roadways. - Soil erosion and sediment control devices shall be in place prior to the commencement of construction activities. - Landscaping shall be in accordance with the requirements of chapter 154 of the landscape code of the City of Port St. Lucie. - No landscaping other than grasses shall be located within 10' of a City utility line or appurtenance. All other utilities shall be a minimum of 5' horizontal separation from City utility mains for parallel installations and a minimum 18" below City mains. (All measurements are take from outside to outside.) - No landscaping shall be placed in a manner that would create conflicts with the intended operation and maintenance of any existing utility. - This application is not vested for any municipal fees. All fees are calculated at time of payment. This includes specifically impact fees, upland preserve fees and any administrative review fees for City Departments. No fees are vested based on date of City Council approval. - Signs are not part of this review and shall be permitted separately from this application. (See Chapter 155 (Sign Code) City of Port St Lucie Land Development Regulations and Section III of the Architectural Designs Standards.) -Public art requirement will be due at time of building permit application for phase 2. -Handicapped parking improvement, bike rack, and public open space will be implemented with phase 2. Drainage Note: THIS PROJECTS INCLUDES THE EXPANSION OF THE EXISTING DETENTION AREA CURRENTLY SERVING THE PREVIOUS PHASES OF THE PROJECT. THE DETENTION AREA EXPANSION WILL BE SIZED TO ACCOMMODATE THE PROPOSED NEW BUILDING AND DRIVEWAY. Legal Description: LOTS 4-14, 17-25, BLOCK 626, PORT ST. LUCIE SECTION THIRTEEN, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 13, PAGE(S) 4, 4A THROUGH 4M, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. Project Team: Client & Property Owner: Land Planner / Landscape Architect: Engineer: Surveyor: Architect: American Personal Storage City of Port St. Lucie, FL Site Plan Phase 2 P#16-121 N.T.S. American Personal Storage 1849 SW South Macedo Blvd Port St. Lucie, FL 34984 Lucido & Associates 701 E Ocean Boulevard Stuart, FL 34994 Engineering Design & Construction 1934 Tucker Court Fort Pierce, FL 34950 Bloomster Surveying, Inc. 641 NE Spencer St Jensen Beach, FL 34957 Patrick M Pillot Architect, Inc. 1267 2nd St Sarasota, FL 34236 Date By Description 07.20.16 TJ Initial Submittal 10.05.16 TJ Resubmittal 11.16.16 TJ Resubmittal 03.03.17 TJ Response to Comments 03.10.17 TJ Response to Comments SW South Macedo Blvd Existing 16" Water Main 8' Ht. NORTH SCALE: 1" = 20' 0 10' 20' 40' REG. # 1018 Thomas P. Lucido Designer Manager Project Number Municipal Number Computer File TRJ Sheet SDG 15-170 --- 15-170 American Personal Storage-Final SitePlan C