SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

Similar documents
AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

A. This Section includes air-handling units with coils for indoor installations.

SECTION AIR HANDLING UNIT

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

1.1 This section applies to air handling units for HVAC Systems.

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION AIR DUCT ACCESSORIES

University of Delaware

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

Construction Standards Page

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION FAN COIL UNITS

SECTION AIR DOORS

AIR HANDLER SPECIFICATION

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Modular Supply Make-Up Air Unit

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

SECTION AIR COILS

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

B. Unit shall be shipped as a single package unless the unit is too large to fit on a standard tractor-trailer.

SECTION AIR COILS

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

15900 HVAC INSTRUMENTATION AND CONTROLS

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

DIVISION 15 MECHANICAL

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

CxA to Answer this Section

SECTION HEATING TERMINAL UNITS

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

SECTION CONVECTION HEATING AND COOLING UNITS

Centeral Station Air Handling Unit

SECTION DUCTWORK

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

SECTION STEAM CONDENSATE PUMPS

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

SECTION CUSTOM FAN WALL AIR HANDLING UNITS

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

SECTION ROOFTOP REPLACEMENT AIR UNITS

A. Codes and Standards that are Standard at the University:

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

SECTION PLUMBING EQUIPMENT

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Chilled Water DOAS Fan Powered Terminal Units

Indirect Gas-Fired Make-Up Air

Modular Heating & Ventilating Unit Model IGX-HV

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise T-Series AHU Full Spec. Prepared by: Phone Number: Prepared for: Acceptable Manufacturers

Design and Construction Standards SECTION PLUMBING EQUIPMENT

SECTION HUMIDITY CONTROL EQUIPMENT

3.0 Factory packaged or modular constructed AHUs, when approved for use, shall conform to the following criteria:

ENGINEERING & SERVICE

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Submittal Data Performance Data Electrical Data

SECTION FIRE PUMP AND CONTROLS

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties.

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

A. Section includes factory-packaged units capable of supplying up to 100 percent outdoor air and providing cooling and heating.

SECTION COMPRESSED-AIR EQUIPMENT FOR LABORATORY FACILITIES

Union County Vocational - Technical Schools Scotch Plains, New Jersey

City of Duluth Festival Center 04/25

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR- HANDLING UNITS

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

C. Samples for Initial Selection: For units with factory-applied color finishes.

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Contents INDEX. TDM Series Indirect Fired Heaters

SECTION CENTRAL HVAC EQUIPMENT

TYPICAL CPA SPECIFICATIONS

Transcription:

SECTION 15855 AIR HANDLING UNITS WITH COILS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Central Station Air Handling Units. B. Related Sections: 1.02 REFERENCES 1. Section 15010 - Basic Mechanical Requirements. 2. Section 15050 - Basic Mechanical Materials and Methods. 3. Section 15240 - Mechanical Sound and Vibration Control. 4. Section 15790 - Air Coils. 5. Section 15885 - Air Cleaning. 6. Section 15990 - Testing, Adjusting and Balancing. 7. Section 09900 - Painting A. Air Conditioning and Refrigeration Institute (ARI). B. National Fire Protection Association (NFPA). C. Underwriter's Laboratories, Inc. (UL). D. National Electrical Manufacturer's Association (NEMA). E. National Electric Code (NEC). F. American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE). G. American National Standards Institute (ANSI). 1.03 SYSTEM DESCRIPTION A. Design Requirements: 1. General: MAY 2012 UCB STANDARDS 15855-1

a. Factory-fabricated and factory-tested air handling units consisting of combinations of sections of fan, coils, pre-heat, filters, plenums, dampers and mixing box as required for project design conditions. b. Equipment shall be of adequate size to handle air quantities and static pressure efficiently in accordance with design. c. Unit performance shall be certified in accordance with ARI Standard 430 for central station air handling units. d. Provide adequate clearances for servicing or removal of motors, drives, bearings, coils, filters and dampers. e. Medium and high velocity draw-through and built-up systems shall have transitions to achieve velocity energy recovery. f. Specify P-traps for condensate drains. g. Specify full NEMA rating of electrical components. h. Specify maximum sound levels at the discharge, return and from casing. 2. Variable Volume: a. Select discharge dampers (forward curved fans only), variable inlet vanes or variable speed drive control to best suit design conditions of air flows and static pressure in harmony with budget and energy conservation requirements for project. 3. Casings: a. Specify access doors that are easily openable for inspection and access to internal parts. b. Specify access door handles to be safety latch type. Thumb screws are not acceptable. c. Specify stainless-steel drain pans for cooling coils and humidifiers to be extensive enough to catch condensate leaving coil at highest catalogued face velocity. Bottom shall be designed to slope to drain to minimize standing water. d. Condensate lines from drain pan must have deep traps to prevent either draw or blow through conditions. Specify proper depth dimension. e. Specify lights with wire guards in accessible sections, factory wired to one switch mounted on casing exterior. Switch shall have pilot light in handle. MAY 2012 UCB STANDARDS 15855-2

f. Downstream of evap. or humidifier sections, specify marine lights with sealed wire-and-glass. g. Specify viewports in evap-pad, filter, fan, damper and humidifier sections. h. Specify insulation to meet NFPA-90A flame spread and smoke generation requirements. i. Specify double-wall construction, with perforated panels in fan section(s). 4. Fan Section: a. See UCB Standards 15010-1.05 for special submittal and construction standards b. The use of a two-fan wheel housing assembly in a common section can be a cause for shaft flexing due to length, and should be evaluated before specifying. c. Fans selected for operation above 6 inches static pressure must be approved by the University. d. Original drive sheaves shall be changed when required by balancing. e. Specify solid steel fan shafts. f. Specify self-aligning, pillow block regreasable ball type fan bearings for an average, L10 life of 200,000 hours at design operating conditions, per ANSI Code B3.15. g. Specify externally accessible fittings for lubrication. h. Fan motors shall be in accordance with "Motors" paragraph in Section 15050 - Basic Mechanical Materials and Methods. 5. Vibration Isolation: (Only if required after consultation with the University) a. Specify entire fan, motor and drive assembly to be internally spring mounted at the factory, together with fan discharge flexible connection and thrust restraint springs. b. Internal factory selected and installed vibration isolation is preferred over an alternate design requiring external field installed deflection springs, pipe and duct flexible connections, thrust restraint springs and spring type pipe hangers on all pipes direct connected to the unit per Section 15240\-\Mechanical Sound and Vibration Control. MAY 2012 UCB STANDARDS 15855-3

6. Coil Sections: a. Provide for removal of coils and space coils to allow for cleaning them without removal. b. Specify differential pressure gage across coils. c. All other coils shall be in accordance with Section 15790 - Air Coils. d. Steam coils shall not exceed 6 feet in width. 7. Damper Sections: a. Bronze or nylon bearings. b. Blades mechanically secured to control rods. c. Blades with neoprene gaskets to seal against entire stop. d. Leakage rate not to exceed 2 percent of air quantity at 2000 fpm velocity through damper and 4 inch w.g. pressure difference. 8. Filter Section: a. Capable of accepting standard 2 inch thick pre-filters and a combination of 4 inch by 24 inch and 24 inch extended-surface retained-media filters. Provide the filters in accordance with Section 15885 - Air Cleaning. b. Provide hinged access doors on both sides for filter replacement. c. Required upstream of all coils, including heat recovery. 9. Casing Section Lengths: a. Indicate minimum lengths for access to filters, coils and dampers. 10. Mixing Boxes: a. Provide equal sized flanged openings capable of handling full air flow. 11. Zone Damper Sections: a. In general, multi-zone type units penalize energy conservation and should be avoided where conditioned air in cold deck is mixed with heated air. 12. Spray Coil Assemblies: MAY 2012 UCB STANDARDS 15855-4

Not acceptable. 13. Direct Evaporative Cooling Section: a. Evaporative-cooling section shall be downstream of all coils. b. Specify stainless steel sumps and housings (i.e., all surfaces subjected to continuous wetting). Sump shall extend 6 upstream of face of media to avoid splashing out of the sump under low airflow conditions. c. Specify stainless-steel fasteners and brackets within, as well as dielectric gaskets between housing and rest of AHU. d. Pump shall be stainless steel with low-water pump cut-off switch in other than residential-type evaporative-cooling systems. Specify a means to disconnect the pump within the unit and an external J- box. e. Specify quick-fill valve within the unit, upstream of the fill float valve. The quick-fill shall have a ball valve with stainless-steel ball, stem and handle, and a brass male hose connection. The discharge of the float valve shall be above the level of the overflow drain. On design drawing, specify P-trap for sump drain. f. Specify copper water-distribution header with flushing valve(s) at each end. Valve shall be full-port with stainless-steel ball, stem and handle and a brass male hose connection. Header supply shall have a flow-control valve with locking handle. Provision for water bleed-off is necessary only if sump automatic drain-down is not used. g. Specify automatic controls to schedule daily drying-out of evaporative media and weekly sump drain-down. In exterior applications, specify automatic drain-down to avoid freezing. h. Specify Glasdek media. Celdek is not acceptable. 14. Indirect Evaporative Cooling a. Is encouraged, either where direct evaporative cooling is being designed or in conjunction with backup/complementary "mechanical air-chilling" coil. b. Chilled water from an absorption chilled-water source may be considered an indirect-cooling coil equivalent when used in conjunction with direct evaporative cooling, and chilled water temperature is controlled by supply air temperature. 15. Humidifiers: MAY 2012 UCB STANDARDS 15855-5

1.04 QUALITY ASSURANCE a. When required, specify steam grid type to inject steam into air stream. Do not use steam from Central Plant. A. Manufacturer's Qualifications: Firms regularly engaged in manufacture of packaged air handling units with characteristics, sizes, and capacities required, whose products have been in satisfactory use in similar service for not less than 5 years. B. Codes and Standards: Comply with the following: PART 2 - PRODUCTS 1. ARI Compliance: Test and rate air handling units in accordance with ARI 430 "Standard for Central-Station Air Handling Units", display certification symbol on units of certified models. 2. NFPA Compliance: Provide air handling unit internal insulation having flame spread rating not over 25 and smoke developed rating no higher than 50; and complying with NFPA 90A "Standard for the Installation of Air Conditioning and Ventilating Systems". 3. UL and NEMA Compliance: Provide electrical components required as part of air handling units, which have been listed and labeled by UL and comply with NEMA Standards. 4. NEC Compliance: Comply with National Electrical Code (NFPA 70) as applicable to installation and electrical connections of ancillary electrical components of air handling units. 5. ASHRAE Compliance: Construct and install refrigerant coils in accordance with ASHRAE 15 "Safety Code for Mechanical Refrigeration. 6. ASHRAE-compliant and UL-approved filters. 2.01 MANUFACTURERS: (Specify only those units with similar quality.) Aerosonics Alliance Annexair ClimateCraft Dunham-Bush Energy Labs Engineered Air Governair Haakon Mammoth McQuay Pace Scott-Springfield Team Air MAY 2012 UCB STANDARDS 15855-6

Temtrol Trane York PART 3 - EXECUTION 3.01 APPLICATION/INSTALLATION A. In general, for project specifications, remove "Design Requirements" subparagraph A in Part 1, paragraph 1.03 "System Description" of this Design Guide and use list to expand on specific project applications in Part 2 - Products and specific installation requirements in this Part 3 for each unit specified. B. Specify that AHU s shall be started only when authorized by UCB staff. END OF SECTION 15855 MAY 2012 UCB STANDARDS 15855-7